954 resultados para ION SELECTIVE ELECTRODE


Relevância:

100.00% 100.00%

Publicador:

Resumo:

In this study, the aim was to measure the concentration of fluoride ions in dental alginates and the quantity released from alginate molds immersed in milliQ water, 0.1N hydrochloric acid and artificial saliva. Two separate lots of each of seven brands of alginate commercially available in Brazil were analyzed: Avagel, Deguprint, Hydrogum, Orthoprint, Jeltrate, Jeltrate Plus and Jeltrate Chromatic. Fluoride was measured in each sample by direct potentiometry, using the combined fluoride-ion selective electrode. The brands with the highest fluoride concentrations were Hydrogum (7052.87 μg/g), Jeltrate Plus (6519.68 μg/g) and Orthoprint (6218.18 μg/g). Only in Hydrogum and Jeltrate were different fluoride concentrations found in lots one and two. The various materials showed differences in the amount of fluoride released from the molds into the immersion medium, the mean concentration being highest in Hydrogum and Orthoprint, in all three media. The immersion medium also influenced the release of fluoride, which was lower in saliva than in water and highest in acid. Considering that the concentrations of fluoride found in the alginates tested were high and that various sources of exposure to fluoride exist, there is a need for constant monitoring of alginates intended for dental use.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This study evaluated the surface microhardness and fluoride release of 5 restorative materials - Ketac-Fil Plus, Vitremer, Fuji II LC, Freedom and Fluorofil - in two storage media: distilled/deionized water and a pH-cycling (pH 4.6). Twelve specimens of each material, were fabricated and the initial surface microhardness (ISM) was determined in a Shimadzu HMV-2000 microhardness tester (static load Knoop). The specimens were submitted to 6- or 18-h cycles in the tested media. The solutions were refreshed at the end of each cycle. All solutions were stored for further analysis. After 15-day storage, the final surface microhardness (FSM) and fluoride release were measured. Fluoride dose was measured with a fluoride-specific electrode (Orion 9609-BN) and digital ion analyzer (Orion 720 A). The variables ISM, FSM and fluoride release were analyzed statistically by analysis of variance and Tukey's test (p<0.05). There was significant difference in FSM between the storage media for Vitremer (pH 4.6 = 40.2 ± 1.5; water = 42.6 ± 1.4), Ketac-Fil Plus (pH 4.6 = 73.4 ± 2.7; water = 58.2 ± 1.3) and Fluorofil (pH 4.6 = 44.3 ± 1.8; water = 38.4 ± 1.0). Ketac-Fil Plus (9.9 ± 18.0) and Fluorofil (4.4 ± 1.3) presented higher fluoride release in water, whereas Vitremer (7.4 ± 7.1), Fuji II LC (5.7 ± 4.7) and Freedom (2.1 ± 1.7) had higher fluoride release at pH 4.6. Microhardness and fluoride release of the tested restorative materials varied according to the storage medium.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This investigation was carried out within São Paulo State, Brazil, and involved the sampling of well-known mineral bottled waters for performing a comparative hydrochemical study and of a spring occurring at Corumbataí city, in order to evaluate its suitability for bottling. Several methods were utilized for acquiring the hydrochemical data like the methyl orange end-point titration, potentiometry, ion selective electrode, colorimetry, flame photometry and inductively-coupled plasma spectrometry. The results obtained for the analyzed samples were compared with the guideline values established by the National Commission of Rules and Standards for Food of the Brazilian Health Ministry published in 1976. The Brazilian Code for Mineral Waters that was established by Register 7841 published on 8 August 1945 was also taken into account for verifying if the spring waters are mineralized. The hydrochemical data allowed identify some constituents impoverishing the water quality, thus, implying on its nonutilization for commercial purposes (bottling). In one specific case, the spring water only can become appropriate for human consumption after previous chemical treatment. © 201 WIT Press.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objetivo: O presente trabalho, dividido em três estudos, teve como objetivo geral identificar e quantificar a liberação de componentes e avaliar a citotoxicidade e a biocompatibilidade de cimentos de ionômero de vidro (CIVs). Método: Para o estudo 1, extratos dos CIVs Vitrebond (VB), Fuji Lining LC (FL), Vitremer (VM), Fuji II LC (FII), Ketac Fil Plus (KF) e Ketac Molar Easymix (KM) foram obtidos pela imersão de corpos-de-prova em meio de cultura celular (DMEM). Esses extratos (n=9 por grupo) foram analisados por eletrodo específico quanto à presença de flúor e por espectrometria de absorção atômica quanto à presença de alumínio e zinco. HEMA e iodobenzeno foram identificados por CG/EM (n=6). Para o estudo 2, células MDPC-23 foram colocadas em contato com os extratos dos CIVs por 24 horas. Em seguida, foram avaliadas a atividade da desidrogenase succínica (SDH) (n=8), a produção de proteína total (PT) (n=8), a atividade da fosfatase alcalina (FAL) (n=8) e a morfologia celular (n=2). Para o estudo 3, tubos de polietileno (n=24 por grupo) foram preenchidos com os CIVs e implantados no tecido subcutâneo de 42 ratos. Como grupo controle foi utilizada a guta-percha. Após 7 ou 15 dias de pós-operatório, metade dos espécimes de cada grupo e período (n=6) foi preparada para análise histológica, e os demais (n=6) para análise da expressão de genes que codificam para IL-1? e TNF-?. Resultados: Os extratos de todos os CIVs apresentaram uma concentração de flúor significativamente maior do que o meio de cultura DMEM (controle), tendo o VB liberado maior quantidade, estatisticamente significante, do que os demais CIVs. O VB foi, também, o único material que liberou quantidades relativamente altas de alumínio e de zinco. O HEMA foi identificado nos extratos de todos os CIVs modificados por resina (VB, FL, VM e FII), e o iodobenzeno... (Resumo completo, clicar acesso eletrônico abaixo)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This study aimed to evaluate saliva and plaque as indicators of intraoral fluoride (F) levels after the use of conventional and high-fluoride dentifrices.Subjects were randomly assigned to brush their teeth with conventional (1000 ppm F), high-fluoride (5000 ppm F), and placebo dentifrices (fluoride free) for 10 days, following a double-blind, crossover protocol. Saliva and plaque samples were collected on the morning of the 5(th) and 10th days, respectively at 1 and 12 h after brushing, and analyzed with an ion-selective electrode after HMDS-facilitated diffusion. Data were analyzed by two-way repeated measures ANOVA, Tukey's test and Spearman's correlation coefficient (p < 0.05).Plaque and salivary F levels were significantly increased after the use of conventional and high-fluoride dentifrices when compared to values obtained for placebo, except plaque 12 h after the use of conventional dentifrice. A positive and significant correlation was found between fluoride concentrations in plaque and saliva for both times of sample collection.Both indicators assessed were able to detect significant differences among treatments and between times after brushing. The use of a high-fluoride dentifrice is able to significantly increase intraoral fluoride levels throughout the day, being therefore a useful therapy for patients at high caries risk.A dentifrice with high fluoride concentration could be regarded as a useful therapy of F delivery for high caries-risk patients, since intraoral F levels were sustained throughout most of the day after using this formulation.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

INTRODUCTION Cardiac myocytes utilize three high-capacity Na transport processes whose precise function can determine myocyte fate and the triggering of arrhythmias in pathological settings. We present recent results on the regulation of all three transporters that may be important for an understanding of cardiac function during ischemia/reperfusion episodes. METHODS AND RESULTS Refined ion selective electrode (ISE) techniques and giant patch methods were used to analyze the function of cardiac Na/K pumps, Na/Ca exchange (NCX1), and Na/H exchange (NHE1) in excised cardiac patches and intact myocytes. To consider results cohesively, simulations were developed that account for electroneutrality of the cytoplasm, ion homeostasis, water homeostasis (i.e., cell volume), and cytoplasmic pH. The Na/K pump determines the average life-time of Na ions (3-10 minutes) as well as K ions (>30 minutes) in the cytoplasm. The long time course of K homeostasis can determine the time course of myocyte volume changes after ion homeostasis is perturbed. In excised patches, cardiac Na/K pumps turn on slowly (-30 seconds) with millimolar ATP dependence, when activated for the first time. In steady state, however, pumps are fully active with <0.2 mM ATP and are nearly unaffected by high ADP (2 mM) and Pi (10 mM) concentrations as may occur in ischemia. NCX1s appear to operate with slippage that contributes to background Na influx and inward current in heart. Thus, myocyte Na levels may be regulated by the inactivation reactions of the exchanger which are both Na- and proton-dependent. NHE1 also undergo strong Na-dependent inactivation, whereby a brief rise of cytoplasmic Na can cause inactivation that persists for many minutes after cytoplasmic Na is removed. This mechanism is blocked by pertussis toxin, suggesting involvement of a Na-dependent G-protein. Given that maximal NCX1- and NHE1-mediated ion fluxes are much greater than maximal Na/K pump-mediated Na extrusion in myocytes, the Na-dependent inactivation mechanisms of NCX1 and NHE1 may be important determinants of cardiac Na homeostasis. CONCLUSIONS Na/K pumps appear to be optimized to continue operation when energy reserves are compromised. Both NCX1 and NHE1 activities are regulated by accumulation of cytoplasmic Na. These principles may importantly control cardiac cytoplasmic Na and promote myocyte survival during ischemia/reperfusion episodes by preventing Ca overload.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Para la cuantificación de nitratos hay numerosas técnicas y no existe entre los analistas unanimidad en la selección de la más adecuada. Por tal motivo, se compararon cuatro métodos para la determinación de nitratos en muestras vegetales con el fin de evaluar la correlación entre los mismos y establecer pautas para su utilización. Se utilizaron 690 muestras de lechuga (Lactuca sativa L. var. capitata), pertenecientes a los tipos arrepollado y mantecoso, recolectadas a lo largo de un año en el Mercado Cooperativo de Guaymallén (Mendoza, Argentina). Según los tenores de nitratos encontrados en la población estudiada se efectuó un sub-muestreo aleatorio estratificado proporcional para lograr un número de muestras que representaran la variabilidad del total de la población. Se utilizaron cuatro métodos para la determinación de nitratos: 1. destilación por arrastre con vapor, considerado como método de referencia 2. colorimetría por nitración con ácido salicílico 3. colorimetría modificada 4. potenciometría con electrodo selectivo Se probaron diferentes modelos de regresión entre el método de referencia y los otros tres, siendo el lineal el que mejor se ajustó en todos los casos. Los métodos estudiados tuvieron comportamiento semejante. La mayor correlación (r2 = 93 %) se observó entre la destilación por arrastre con vapor y la potenciometría; no obstante, los restantes también presentaron alta correlación. Consecuentemente, la elección del procedimiento analítico dependerá principalmente del número de muestras a analizar, del tiempo requerido por el análisis y del costo del mismo.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The selective manipulation of mitochondrial DNA (mtDNA) replication and expression within mammalian cells has proven difficult. One promising approach is to use peptide nucleic acid (PNA) oligomers, nucleic acid analogues that bind selectively to complementary DNA or RNA sequences inhibiting replication and translation. However, the potential of PNAs is restricted by the difficulties of delivering them to mitochondria within cells. To overcome this problem we conjugated a PNA 11mer to a lipophilic phosphonium cation. Such cations are taken up by mitochondria through the lipid bilayer driven by the membrane potential across the inner membrane. As anticipated, phosphonium–PNA (ph–PNA) conjugates of 3.4–4 kDa were imported into both isolated mitochondria and mitochondria within human cells in culture. This was confirmed by using an ion-selective electrode to measure uptake of the ph–PNA conjugates; by cell fractionation in conjunction with immunoblotting; by confocal microscopy; by immunogold-electron microscopy; and by crosslinking ph–PNA conjugates to mitochondrial matrix proteins. In all cases dissipating the mitochondrial membrane potential with an uncoupler prevented ph–PNA uptake. The ph–PNA conjugate selectively inhibited the in vitro replication of DNA containing the A8344G point mutation that causes the human mtDNA disease ‘myoclonic epilepsy and ragged red fibres’ (MERRF) but not the wild-type sequence that differs at a single nucleotide position. Therefore these modified PNA oligomers retain their selective binding to DNA and the lipophilic cation delivers them to mitochondria within cells. When MERRF cells were incubated with the ph–PNA conjugate the ratio of MERRF to wild-type mtDNA was unaffected, even though the ph–PNA content of the mitochondria was sufficient to inhibit MERRF mtDNA replication in a cell-free system. This unexpected finding suggests that nucleic acid derivatives cannot bind their complementary sequences during mtDNA replication. In summary, we have developed a new strategy for targeting PNA oligomers to mitochondria and used it to determine the effects of PNA on mutated mtDNA replication in cells. This work presents new approaches for the manipulation of mtDNA replication and expression, and will assist in the development of therapies for mtDNA diseases.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Analysis methods for electrochemical etching baths consisting of various concentrations of hydrofluoric acid (HF) and an additional organic surface wetting agent are presented. These electrolytes are used for the formation of meso- and macroporous silicon. Monitoring the etching bath composition requires at least one method each for the determination of the HF concentration and the organic content of the bath. However, it is a precondition that the analysis equipment withstands the aggressive HF. Titration and a fluoride ion-selective electrode are used for the determination of the HF and a cuvette test method for the analysis of the organic content, respectively. The most suitable analysis method is identified depending on the components in the electrolyte with the focus on capability of resistance against the aggressive HF.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A flow injection analysis (FIA) system comprising a tartrate- (TAT) selective electrode has been developed for determination of tartaric acid in wines. Several electrodes constructed for this purpose had a PVC membrane with a complex of quaternary ammonium and TAT as anion exchanger, a phenol derivative as additive, and a more or less polar mediator solvent. Characterization of the electrodes showed behavior was best for membranes with o-nitrophenyl octyl ether as solvent. On injection of 500 μL into a phosphate buffer carrier (pH = 3.1; ionic strength 10–2 mol/L) flowing at 3 mL/min, the slope was 58.06 ± 0.6 with a lower limit of linear range of 5.0 × 10–4 mol/L TAT and R2 = 0.9989. The interference of several species, e.g. chloride, bromide, iodide, nitrate, gallic acid, tannin, sucrose, glucose, fructose, acetate, and citrate, was evaluated in terms of potentiometric selectivity coefficients. The Hofmeister series was followed for inorganic species and the most interfering organic ion was citrate. When red and white wines were analyzed and the results compared with those from an independent method they were found to be accurate, with relative standard deviations below 5.0%.