944 resultados para INTRAVASCULAR ULTRASOUND (IVUS)


Relevância:

80.00% 80.00%

Publicador:

Resumo:

The aim of this experimental study is to evaluate the feasibility and the outcome of total endovascular stent implantation in the aortic arch. Indications for this operation-technique would be acute or chronic dissection of the aortic arch (non-A-non-B dissection) or type B dissection with retrograde extension. Four pigs were canulated via the distal abdominal aorta and a retrograde placement of a Djumbodis arch stent (4-9 cm) was controlled by using intravascular ultrasound and intracardiac ultrasound by the inferior cava vein and under radioscopic control. Cerebral perfusion, by using a flow meter placed on one prepared carotid artery, were controlled before, immediate post-procedural (<1 min), and in the early follow-up after aortic arch stent implantation. During the implantation process, especially during balloon inflation and deflation, mean carotid perfusion decreases slightly. A reactive increase of carotid perfusion after stent placements indicates transitory cerebral hypo-perfusion. Non-covered aortic arch stent implantation is technically feasible and could be a potential treatment option in otherwise inoperable arch dissections. The time required for balloon inflation and deflation causes an important risk of cerebral ischemia. The latter can be reduced by transaxillary perfusion.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Différentes méthodes ayant pour objectif une utilisation optimale d'antennes radio-fréquences spécialisées en imagerie par résonance magnétique sont développées et validées. Dans un premier temps, il est démontré qu'une méthode alternative de combinaison des signaux provenant des différents canaux de réception d'un réseau d'antennes mène à une réduction significative du biais causé par la présence de bruit dans des images de diffusion, en comparaison avec la méthode de la somme-des-carrés généralement utilisée. Cette réduction du biais engendré par le bruit permet une amélioration de l'exactitude de l'estimation de différents paramètres de diffusion et de diffusion tensorielle. De plus, il est démontré que cette méthode peut être utilisée conjointement avec une acquisition régulière sans accélération, mais également en présence d'imagerie parallèle. Dans une seconde perspective, les bénéfices engendrés par l'utilisation d'une antenne d'imagerie intravasculaire sont étudiés. Suite à une étude sur fantôme, il est démontré que l'imagerie par résonance magnétique intravasculaire offre le potentiel d'améliorer significativement l'exactitude géométrique lors de mesures morphologiques vasculaires, en comparaison avec les résultats obtenus avec des antennes de surface classiques. Il est illustré qu'une exactitude géométrique comparable à celle obtenue grâce à une sonde ultrasonique intravasculaire peut être atteinte. De plus, plusieurs protocoles basés sur une acquisition de type balanced steady-state free-precession sont comparés dans le but de mettre en évidence différentes relations entre les paramètres utilisés et l'exactitude géométrique obtenue. En particulier, des dépendances entre la taille du vaisseau, le rapport signal-sur-bruit à la paroi vasculaire, la résolution spatiale et l'exactitude géométrique atteinte sont mises en évidence. Dans une même optique, il est illustré que l'utilisation d'une antenne intravasculaire permet une amélioration notable de la visualisation de la lumière d'une endoprothèse vasculaire. Lorsque utilisée conjointement avec une séquence de type balanced steady-state free-precession utilisant un angle de basculement spécialement sélectionné, l'imagerie par résonance magnétique intravasculaire permet d'éliminer complètement les limitations normalement engendrées par l'effet de blindage radio-fréquence de l'endoprothèse.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Introducción: Las enfermedades cardiovasculares son la causa de muerte más frecuente en el mundo desarrollado, la mayoría de éstas se relacionan con alteraciones de las arterias coronarias, sin embargo un subgrupo de pacientes presentan como causa de isquemia cardiaca alteraciones estructurales. Material y métodos: Estudio Descriptivo. Se utilizó la base de datos recolectada en un servicio de hemodinamia de Bogotá durante dos años. Se aplicaron criterios de inclusión y exclusión y se determinaron cuatro grupos etáreos, a todos los pacientes se les practicó cateterismo cardiaco diagnóstico. Las variables analizadas fueron: diagnóstico de referencia, antecedentes y resultados del cateterismo incluyendo presencia de anomalías estructurales como las valvulopatias, el origen anómalo de las coronarias y los puentes miocárdicos. Para el análisis descriptivo se utilizó reporte de prevalencias y para el análisis de asociaciones se utilizaron tablas de contingencia y el estadístico de prueba Chi cuadrado, no se realizó análisis multivariado debido a que no se encontraron asociaciones estadísticamente significativas. Resultados: La edad promedio de los pacientes fue de 62 años (DS= 10,5), la representación del género masculino fue del 61,7%, la prevalencia de angina estable fue del 61,6%, los 3 antecedentes más prevalentes fueron: hipertensión arterial (41,4%), la hiperlipidemia (19,1%) y la Diabetes Mellitus (17,7%). La prevalencia de las alteraciones estructurales en la población de estudio de manera general fue del 12,9%, y su distribución por tipo fue: 1,4% para puentes miocárdicos, 0,7% para origen anómalo de las arterias coronarias y 10,8% de enfermedad valvular. Conclusiones: Se encontró una asociación entre los antecedentes médicos y la presencia de valvulopatias cardiacas. Se evidenció que el género no tiene relación con la presencia de alteraciones cardíacas a pesar de la mayor participación de hombres en la población de estudio. Las limitantes de este estudio se relacionaron con el tamaño de muestra, debido a la baja prevalencia de las anomalías estructurales medidas.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Introducción: La disminución de flujo en los vasos coronarios sin presencia de oclusión, es conocido como fenómeno de no reflujo, se observa después de la reperfusión, su presentación oscila entre el 5% y el 50% dependiendo de la población y de los criterios diagnósticos, dicho suceso es de mal pronóstico, aumenta el riesgo de morir en los primeros 30 días posterior a la angioplastia (RR 2,1 p 0,038), y se relaciona con falla cardiaca y arritmias, por eso al identificar los factores a los cuales se asocia, se podrán implementar terapias preventivas. Metodología: Estudio de casos y controles pareado por médico que valoró el evento, para garantizar que no existieron variaciones inter observador, con una razón 1:4 (18:72), realizado para identificar factores asociados a la presencia de no reflujo en pacientes llevados a angioplastia, entre noviembre de 2010 y mayo de 2014, en la Clínica San Rafael de Bogotá, D.C. Resultados: La frecuencia del no reflujo fue del 2.89%. El Infarto Agudo de Miocardio con elevación del ST (IAMCEST) fue la única variable que mostró una asociación estadísticamente significativa con este suceso, valor de p 0,002, OR 8,7, IC 95% (2,0 – 36,7). Discusión: El fenómeno de no reflujo en esta población se comportó de manera similar a lo descrito en la literatura, siendo el IAMCEST un factor fuertemente asociado.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Background Current recommendations for antithrombotic therapy after drug-eluting stent (DES) implantation include prolonged dual antiplatelet therapy (DAPT) with aspirin and clopidogrel >= 12 months. However, the impact of such a regimen for all patients receiving any DES system remains unclear based on scientific evidence available to date. Also, several other shortcomings have been identified with prolonged DAPT, including bleeding complications, compliance, and cost. The second-generation Endeavor zotarolimus-eluting stent (E-ZES) has demonstrated efficacy and safety, despite short duration DAPT (3 months) in the majority of studies. Still, the safety and clinical impact of short-term DAPT with E-ZES in the real world is yet to be determined. Methods The OPTIMIZE trial is a large, prospective, multicenter, randomized (1: 1) non-inferiority clinical evaluation of short-term (3 months) vs long-term (12-months) DAPT in patients undergoing E-ZES implantation in daily clinical practice. Overall, 3,120 patients were enrolled at 33 clinical sites in Brazil. The primary composite endpoint is death (any cause), myocardial infarction, cerebral vascular accident, and major bleeding at 12-month clinical follow-up post-index procedure. Conclusions The OPTIMIZE clinical trial will determine the clinical implications of DAPT duration with the second generation E-ZES in real-world patients undergoing percutaneous coronary intervention. (Am Heart J 2012;164:810-816.e3.)

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Semi-quantitative stenosis assessment by coronary CT angiography only modestly predicts stress-induced myocardial perfusion abnormalities. The performance of quantitative CT angiography (QCTA) for identifying patients with myocardial perfusion defects remains unclear. CorE-64 is a multicenter, international study to assess the accuracy of 64-slice QCTA for detecting a parts per thousand yen50% coronary arterial stenoses by quantitative coronary angiography (QCA). Patients referred for cardiac catheterization with suspected or known coronary artery disease were enrolled. Area under the receiver-operating-characteristic curve (AUC) was used to evaluate the diagnostic accuracy of the most severe coronary artery stenosis in a subset of 63 patients assessed by QCTA and QCA for detecting myocardial perfusion abnormalities on exercise or pharmacologic stress SPECT. Diagnostic accuracy of QCTA for identifying patients with myocardial perfusion abnormalities by SPECT revealed an AUC of 0.71, compared to 0.72 by QCA (P = .75). AUC did not improve after excluding studies with fixed myocardial perfusion abnormalities and total coronary arterial occlusions. Optimal stenosis threshold for QCTA was 43% yielding a sensitivity of 0.81 and specificity of 0.50, respectively, compared to 0.75 and 0.69 by QCA at a threshold of 59%. Sensitivity and specificity of QCTA to identify patients with both obstructive lesions and myocardial perfusion defects were 0.94 and 0.77, respectively. Coronary artery stenosis assessment by QCTA or QCA only modestly predicts the presence and the absence of myocardial perfusion abnormalities by SPECT. Confounding variables affecting the relationship between coronary anatomy and myocardial perfusion likely account for some of the observed discrepancies between coronary angiography and SPECT results.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Purpose: The pathophysiology of acute coronary syndromes (ACS) after noncardiac surgery is not established yet. Thrombosis over a vulnerable plaque or decreased oxygen supply secondary to anemia or hypotension may be involved. The purpose of this study was to investigate the pathophysiology of ACS complicating noncardiac surgery. Methods: Clinical and angiographic data were prospectively recorded into a database for 120 consecutive patients that had an ACS after noncardiac surgery (PACS), for 120 patients with spontaneous ACS (SACS), and 240 patients with stable coronary artery disease (CAD). Coronary lesions with obstructions greater than 50% were classified based on two criteria: Ambrose's classification and complex morphology. The presence of Ambrose's type II or complex lesions were compared between the three groups. Results: We analyzed 1470 lesions in 480 patients. In PACS group, 45% of patients had Ambrose's type II lesions vs. 56.7% in SACS group and 16.4% in stable CAD group (P < 0.001). Both PACS and SACS patients had more complex lesions than patients in stable CAD group (56.7% vs. 79.2% vs. 31.8%, respectively; P < 0.001). Overall, the independent predictors of plaque rupture were being in the group PACS (P < 0.001, OR 2.86; CI, 1.82-4.52 for complex lesions and P < 0.001, OR 3.43; CI, 2.1-5.6 for Ambrose's type II lesions) or SACS (P < 0.001, OR 8.71; CI, 5.15-14.73 for complex lesions and P < 0.001, OR 5.99; CI, 3.66-9.81 for Ambrose's type II lesions). Conclusions: Nearly 50% of patients with perioperative ACS have evidence of coronary plaque rupture, characterizing a type 1 myocardial infarction. (C) 2012 Elsevier Ireland Ltd. All rights reserved.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The aim of the Research of this Ph D Project is to improve the medical management after surgery for advanced heart failure, both after left ventricular assist devices (LVAD) implantation, and after heart transplantation in the long-term. Regarding heart transplantation (HTx), the Research Project is focused on diagnostics, classification, prevention and treatment of cardiac allograft vasculopathy (CAV), and on treatment of post-HTx cancers; the results are presented in the first part of this Thesis. In particular, the main aspect investigated are the prognostic role of information derived from coronary angiography, coronary tomography and intravascular ultrasound, and the different sensitivity of these techniques in predicting outcomes and in diagnosing CAV. Moreover, the role of mTOR inhibitors on CAV prevention or treatment is investigated, both alone and in combination with different anti-CMV prevention strategies, as well as the impact of mTOR inhibitors on clinical outcomes in the long term. Regarding LVAD, the main focus is on the role of transthoracic echocardiography in the management of patients with a continuous-flow, centrifugal, intrapericardial pump (HVAD, Heartware); this section is reported in the second part of this Thesis. The main aspects investigated are the use of echocardiography in patients with HVAD device and its interaction with the information derived from pump curves' analysis in predicting aortic valve opening status, a surrogate of the condition of support provided by the LVAD.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Incomplete endothelialization has been found to be associated with late stent thrombosis, a rare but devastating phenomenon, more frequent after drug-eluting stent implantation. Optical coherence tomography (OCT) has 10 times greater resolution than intravascular ultrasound and thus appears to be a valuable modality for the assessment of stent strut coverage. The LEADERS trial was a multi-centre, randomized comparison of a biolimus-eluting stent (BES) with biodegradable polymer with a sirolimus-eluting stent (SES) using a durable polymer. This study sought to evaluate tissue coverage and apposition of stents using OCT in a group of patients from the randomized LEADERS trial.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Coronary late stent thrombosis, a rare but devastating complication, remains an important concern in particular with the increasing use of drug-eluting stents. Notably, pathological studies have indicated that the proportion of uncovered coronary stent struts represents the best morphometric predictor of late stent thrombosis. Intracoronary optical frequency domain imaging (OFDI), a novel second-generation optical coherence tomography (OCT)-derived imaging method, may allow rapid imaging for the detection of coronary stent strut coverage with a markedly higher precision when compared with intravascular ultrasound, due to a microscopic resolution (axial approximately 10-20 microm), and at a substantially increased speed of image acquisition when compared with first-generation time-domain OCT. However, a histological validation of coronary OFDI for the evaluation of stent strut coverage in vivo is urgently needed. Hence, the present study was designed to evaluate the capacity of coronary OFDI by electron (SEM) and light microscopy (LM) analysis to detect and evaluate stent strut coverage in a porcine model.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Background—Pathology studies on fatal cases of very late stent thrombosis have described incomplete neointimal coverage as common substrate, in some cases appearing at side-branch struts. Intravascular ultrasound studies have described the association between incomplete stent apposition (ISA) and stent thrombosis, but the mechanism explaining this association remains unclear. Whether the neointimal coverage of nonapposed side-branch and ISA struts is delayed with respect to well-apposed struts is unknown. Methods and Results—Optical coherence tomography studies from 178 stents implanted in 99 patients from 2 randomized trials were analyzed at 9 to 13 months of follow-up. The sample included 38 sirolimus-eluting, 33 biolimus-eluting, 57 everolimus-eluting, and 50 zotarolimus-eluting stents. Optical coherence tomography coverage of nonapposed side-branch and ISA struts was compared with well-apposed struts of the same stent by statistical pooled analysis with a random-effects model. A total of 34 120 struts were analyzed. The risk ratio of delayed coverage was 9.00 (95% confidence interval, 6.58 to 12.32) for nonapposed side-branch versus well-apposed struts, 9.10 (95% confidence interval, 7.34 to 11.28) for ISA versus well-apposed struts, and 1.73 (95% confidence interval, 1.34 to 2.23) for ISA versus nonapposed side-branch struts. Heterogeneity of the effect was observed in the comparison of ISA versus well-apposed struts (H=1.27; I2=38.40) but not in the other comparisons. Conclusions—Coverage of ISA and nonapposed side-branch struts is delayed with respect to well-apposed struts in drug-eluting stents, as assessed by optical coherence tomography.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

BACKGROUND: Stent thrombosis may occur late after drug-eluting stent (DES) implantation, and its cause remains unknown. The present study investigated differences of the stented segment between patients with and without very late stent thrombosis with the use of intravascular ultrasound. METHODS AND RESULTS: Since January 2004, patients presenting with very late stent thrombosis (> 1 year) after DES implantation underwent intravascular ultrasound. Findings in patients with very late stent thrombosis were compared with intravascular ultrasound routinely obtained 8 months after DES implantation in 144 control patients, who did not experience stent thrombosis for > or = 2 years. Very late stent thrombosis was encountered in 13 patients at a mean of 630+/-166 days after DES implantation. Compared with DES controls, patients with very late stent thrombosis had longer lesions (23.9+/-16.0 versus 13.3+/-7.9 mm; P<0.001) and stents (34.6+/-22.4 versus 18.6+/-9.5 mm; P<0.001), more stents per lesion (1.6+/-0.9 versus 1.1+/-0.4; P<0.001), and stent overlap (39% versus 8%; P<0.001). Vessel cross-sectional area was similar for the reference segment (cross-sectional area of the external elastic membrane: 18.9+/-6.9 versus 20.4+/-7.2 mm2; P=0.46) but significantly larger for the in-stent segment (28.6+/-11.9 versus 20.1+/-6.7 mm2; P=0.03) in very late stent thrombosis patients compared with DES controls. Incomplete stent apposition was more frequent (77% versus 12%; P<0.001) and maximal incomplete stent apposition area was larger (8.3+/-7.5 versus 4.0+/-3.8 mm2; P=0.03) in patients with very late stent thrombosis compared with controls. CONCLUSIONS: Incomplete stent apposition is highly prevalent in patients with very late stent thrombosis after DES implantation, suggesting a role in the pathogenesis of this adverse event.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

BACKGROUND: Coronary stents improve immediate and late results of balloon angioplasty by tacking up dissections and preventing wall recoil. These goals are achieved within weeks after angioplasty, but with current technology stents permanently remain in the artery, with many limitations including the need for long-term antiplatelet treatment to avoid thrombosis. We report a prospective multicentre clinical trial of coronary implantations of absorbable magnesium stents. METHODS: We enrolled 63 patients (44 men; mean age 61.3 [SD 9.5 years]) in eight centres with single de novo lesions in a native coronary artery in a multicentre, non-randomised prospective study. Follow-up included coronary angiography and intravascular ultrasound at 4 months and clinical assessment at 6 months and 12 months. The primary endpoint was cardiac death, non-fatal myocardial infarction, or clinically driven target lesion revascularisation at 4 months FINDINGS: 71 stents, 10-15 mm in length and 3.0-3.5 mm in diameter, were successfully implanted after pre-dilatation in 63 patients. Diameter stenosis was reduced from 61.5 (SD 13.1%) to 12.6 (5.6%) with an acute gain of 1.41 mm (0.46 mm) and in-stent late loss of 1.08 mm (0.49 mm). The ischaemia-driven target lesion revascularisation rate was 23.8% after 4 months, and the overall target lesion revascularisation rate was 45% after 1 year. No myocardial infarction, subacute or late thrombosis, or death occurred. Angiography at 4 months showed an increased diameter stenosis of 48.4 (17.0%). After serial intravascular ultrasound examinations, only small remnants of the original struts were visible, well embedded into the intima. Neointimal growth and negative remodelling were the main operating mechanisms of restenosis. INTERPRETATION: This study shows that biodegradable magnesium stents can achieve an immediate angiographic result similar to the result of other metal stents and can be safely degraded after 4 months. Modifications of stent characteristics with prolonged degradation and drug elution are currently in development.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

In industrial countries, cardiovascular diseases remain the primary cause of death. This review summarizes the role of percutaneous coronary interventions (PCI) in the treatment of coronary heart disease. Interventional therapy of coronary artery disease was initiated in 1977 with the introduction of balloon angioplasty by Andreas Grüntzig in Zurich. Technical progress since has been related to construction and materials of catheters, but also to digital processing of x-ray imaging. Additional methods - rotablation, atherectomy, laser, intravascular ultrasound, and most importantly stent implantation were developed. Only stents significantly changed the procedure. They are today an integral part of PCI.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The efficacy of everolimus with reduced cyclosporine in de novo heart transplant patients has been demonstrated convincingly in randomized studies. Moreover, everolimus-based immunosuppression in de novo heart transplant recipients has been shown in two randomized trials to reduce the increase in maximal intimal thickness based on intravascular ultrasound, indicating attenuation of cardiac allograft vasculopathy (CAV). Randomized trials of everolimus in de novo heart transplantation have also consistently shown reduced cytomegalovirus infection versus antimetabolite therapy. In maintenance heart transplantation, conversion from calcineurin inhibitors to everolimus has demonstrated a sustained improvement in renal function. In de novo patients, a renal benefit may only be achieved if there is an adequate reduction in exposure to calcineurin inhibitor therapy. Delayed introduction of everolimus may be appropriate in patients at high risk of wound healing complications, e.g. diabetic patients or patients with ventricular assist device. The current evidence base suggests that the most convincing reasons for use of everolimus from the time of heart transplantation are to slow the progression of CAV and to lower the risk of cytomegalovirus infection. A regimen of everolimus with reduced-exposure calcineurin inhibitor and steroids in de novo heart transplant patients represents a welcome addition to the therapeutic armamentarium.