953 resultados para Hydraulic machines
Resumo:
Culverts are among the most common hydraulic structures. Modern designs do not differ from ancient structures and are often characterised by significant afflux at design flows. A significant advance was the development of the Minimum Energy Loss (MEL) culverts in the late 1950s. The design technique allows a drastic reduction in upstream flooding associated with lower costs. The development and operational performances of this type of structure is presented. The successful operation of MEL culverts for more than 40 years is documented with first-hand records during and after floods. The experiences demonstrate the design soundness while highlighting the importance of the hydraulic expertise of the design engineers.
Resumo:
The biological reactions during the settling and decant periods of Sequencing Batch Reactors (SBRs) are generally ignored as they are not easily measured or described by modelling approaches. However, important processes are taking place, and in particular when the influent is fed into the bottom of the reactor at the same time (one of the main features of the UniFed process), the inclusion of these stages is crucial for accurate process predictions. Due to the vertical stratification of both liquid and solid components, a one-dimensional hydraulic model is combined with a modified ASM2d biological model to allow the prediction of settling velocity, sludge concentration, soluble components and biological processes during the non-mixed periods of the SBR. The model is calibrated on a full-scale UniFed SBR system with tracer breakthrough tests, depth profiles of particulate and soluble compounds and measurements of the key components during the mixed aerobic period. This model is then validated against results from an independent experimental period with considerably different operating parameters. In both cases, the model is able to accurately predict the stratification and most of the biological reactions occurring in the sludge blanket and the supernatant during the non-mixed periods. Together with a correct description of the mixed aerobic period, a good prediction of the overall SBR performance can be achieved.
Resumo:
The effects of various fallow management systems and cropping intensities on water infiltration were measured on an Alfisol at Ibadan in southwestern Nigeria. The objective was to determine the influence of the land use systems (a combination of crop-fallow sequences and intercropping types) on soil hydraulic properties obtained by disc permeameter and double-ring infiltration measurements. The experiment was established in 1989 as a split-plot design with four replications. The main plots were natural fallow, planted Pueraria phaseoloides and planted Leucaena leucocephala. The subplots were 1 year of maize/cassava intercrop followed by 3-year fallow (25% cropping intensity), or 2-year fallow (33% cropping intensity), or 1-year fallow (50% cropping intensity), or no fallow period (100% cropping intensity). Water infiltration rates and sorptivities were measured under saturated and unsaturated flow. Irrespective of land use, infiltration rates at the soil surface (121-324 cm h(-1)) were greater than those measured at 30 cm depth (55-144 cm h(-1)). This indicated that fewer large pores were present below 30 cm depth compared with 0-30 cm, depth. Despite some temporal variation, sorptivities with the highest mean value of 93.5 cm h(-1/2) increased as the cropping intensity decreased, suggesting a more continuous macropore system under less intensive land use systems. This was most likely due to continuous biopores created by perennial vegetation under long fallow systems. Intercropped maize and cassava yields also increased as cropping intensity decreased. The weak relationship between crop yields and hydraulic conductivity/infiltration rates suggests that the rates were not limiting.
Hydraulic conductivity in response to exchangeable sodium percentage and solution salt concentration
Resumo:
Hydraulic conductivity is determined in laboratory assays to estimate the flow of water in saturated soils. However, the results of this analysis, when using distilled or deionized water, may not correspond to field conditions in soils with high concentrations of soluble salts. This study therefore set out to determine the hydraulic conductivity in laboratory conditions using solutions of different electrical conductivities in six soils representative of the State of Pernambuco, with the exchangeable sodium percentage adjusted in the range of 5-30%. The results showed an increase in hydraulic conductivity with both decreasing exchangeable sodium percentage and increasing electrical conductivity in the solution. The response to the treatments was more pronounced in soils with higher proportion of more active clays. Determination of hydraulic conductivity in laboratory is routinely performed with deionized or distilled water. However, in salt affected soils, these determinations should be carried out using solutions of electrical conductivity different from 0 dS m-1, with values close to those determined in the saturation extracts.
Computational evaluation of hydraulic system behaviour with entrapped air under rapid pressurization
Resumo:
The pressurization of hydraulic systems containing entrapped air is considered a critical condition for the infrastructure's security due to transient pressure variations often occurred. The objective of the present study is the computational evaluation of trends observed in variation of maximum surge pressure resulting from rapid pressurizations. The comparison of the results with those obtained in previous studies is also undertaken. A brief state of art in this domain is presented. This research work is applied to an experimental system having entrapped air in the top of a vertical pipe section. The evaluation is developed through the elastic model based on the method of characteristics, considering a moving liquid boundary, with the results being compared with those achieved with the rigid liquid column model.
Computational evaluation of hydraulic system behaviour with entrapped air under rapid pressurization
Resumo:
The pressurization of hydraulic systems containing entrapped air is considered a critical condition for the infrastructure's security due to transient pressure variations often occurred. The objective of the present study is the computational evaluation of trends observed in variation of maximum surge pressure resulting from rapid pressurizations. The comparison of the results with those obtained in previous studies is also undertaken. A brief state of art in this domain is presented. This research work is applied to an experimental system having entrapped air in the top of a vertical pipe section. The evaluation is developed through the elastic model based on the method of characteristics, considering a moving liquid boundary, with the results being compared with those achieved with the rigid liquid column model.
Resumo:
A Mundotêxtil foi fundada em 1975 tendo iniciado a sua actividade na área comercial de produtos têxteis. Actualmente é o maior produtor nacional de atoalhados de felpo e emprega 575 colaboradores. Como resultado do seu crescimento e sobretudo da actividade de tingimento de fio e felpo, as necessidades de água são consideráveis e o volume de efluentes gerados nos processos industriais é cada vez maior a empresa avançou com a construção de uma estação de tratamento por lamas activadas, colocando-a em funcionamento em Setembro de 2004. Inicialmente surgiram dificuldades para a remoção da cor e da concentração da Carência Química de Oxigénio (CQO) de modo a cumprir os limites máximos de emissão permitidos nas normas de descarga no rio Ave e no Decreto-Lei nº 236/98, de 1 de Agosto. Com a descarga de parte dos efluentes no SIDVA e a utilização de um coagulante adicionado ao reactor o tratamento passou a apresentar melhores resultados. O intuito deste trabalho é o de apresentar soluções de modo a optimizar o funcionamento do tratamento biológico da Mundotêxtil. A optimização pode começar na concepção dos produtos, pode incidir no processo de fabrico para além de poder ser efectuada no seio da estação de tratamento biológico. Foi efectuado um estudo do tratamento biológico por lamas activadas no Laboratório de Tecnologia Química Profª Doutora Lída de Vasconcelos, laboratório tecnológico do Instituto Superior de Engenharia do Porto (ISEP) que decorreu nos meses de Maio, Junho e Julho de 2010. O estudo laboratorial foi efectuado para três situações distintas: 1) tratamento do efluente bruto sem qualquer tipo de pré-tratamento (ensaios 1 a 3); 2) tratamento do efluente bruto submetido a pré-tratamento com coagulante Ambifloc BIO MD (ensaios 4 e 5) e 3) tratamento com adição de fungos ao tanque de arejamento (ensaio 6). Foram utilizadas duas instalações de tratamento alimentadas a partir do mesmo tanque de alimentação. Os dois sistemas eram idênticos, diferiram nos caudais de alimentação de efluente que foram alterados ao longo do estudo. O efluente a tratar foi fornecido pela empresa Mundotêxtil, sendo recolhido por diversas vezes ao longo dos ensaios. Este efluente foi retirado após o pré-tratamento da empresa, ou seja este efluente é o mesmo que alimenta o tratamento biológico da Mundotêxtil. Devido a este facto o efluente usado no estudo laboratorial teve uma variabilidade no período em que decorreu o estudo, nomeadamente em termos de concentração de CQO e cor. A relação entre a Carência Bioquímica (CBO5) e a CQO situouse entre 0,47 e 0,63 o que traduz que está dentro dos valores típicos para um efluente têxtil. Os melhores resultados globais de remoção de CQO foram obtidos no ensaio 5 e estiveram compreendidos entre 73,2% e 77,5% para o ensaio 5.1 e entre 62,9 e 73,2% para o ensaio 5.2. Neste ensaio foi utilizado o coagulante. Todos os valores de concentração de CQO obtidos nos efluentes dos decantadores para os ensaios 2, 5 e 6 são inferiores aos valores limite de descarga definidos nas normas de descarga no rio Ave e o Decreto-Lei 236/98. Os valores de concentração de Sólidos Suspensos Totais (SST), pH, fósforo, CBO5 e cor nos decantadores cumpriram os limites de descarga definidos nas normas de descarga no rio Ave e no Decreto-Lei nº 236/98 em todos os ensaios. Os parâmetros cinéticos obtidos para os ensaios com descorante são os que melhor se ajustam ao projecto de uma instalação de tratamento biológico por lamas activadas do efluente da Mundotêxtil. Os valores obtidos, após ajuste, são os seguintes: k=0,015 L/(mgSSV*d); Sn=12 mg/L; a=0,7982 kgO2/kgCBO5; b=0,0233 [kgO2/(kgSSV*d); y=0,2253 kgSSV/kgCBO5; kd=0,0036 kgSSV/(kgSSV*d. Com base nos parâmetros cinéticos obtiveram-se os seguintes resultados para o projecto de uma estação de tratamento biológico por lamas activadas: · Tempo de retenção hidráulica no reactor de 1,79 d, · Volume do reactor igual a 3643 m3 · Consumo de oxigénio no reactor de 604 kg/d · Razão de recirculação igual a 0,8 · Volume total do decantador secundário igual a 540 m3 · Diâmetro do decantador secundário igual a 15 m A quantidade de oxigénio necessário é baixa e o valor mais adequado deverá ser da ordem de 1200 kg/d. Também foi efectuada uma análise aos produtos químicos consumidos pela empresa na área das tinturarias com a finalidade de identificar as substâncias com uma maior influência potencial no funcionamento da Estação de Tratamento Biológico. O encolante CB, Cera Têxtil P Líquida, Perfemina P-12, Meropan DPE-P, Meropan BRE-P, Indimina STS e Benzym TEC são os produtos químicos que têm uma influência potencial mais significativa na qualidade dos efluentes. Devido ao facto das temperaturas do efluente alimentado ao tratamento biológico da Mundotêxtil oscilarem entre 35 ºC e 43ºC efectuou-se um estudo às necessidades de água quente das tinturarias e por outro lado à capacidade de aquecimento dos efluentes disponíveis. Actualmente a racionalização dos consumos de água é cada vez mais premente, por isso também é apresentado neste trabalho um estudo para a substituição das máquinas convencionais das tinturarias com uma relação de banho 1:10 por máquinas de banho curto (1:6,5). Verifica-se a redução de consumos de 40% de água, 52% de energia eléctrica, 35% de produtos químicos, 51% das necessidades de vapor e por consequência um aumento da produtividade. A empresa pode reduzir os consumos de água em cerca de 280.000 m3/ano. A utilização do pré-tratamento com o coagulante permitirá baixar a concentração da CQO e reduzir a cor à entrada do reactor tratamento biológico. Deste modo é possível manter um tratamento eficiente à saída do tratamento biológico nas situações de descarga de cores carregadas e carga orgânica elevada. Com este conjunto de soluções, quer sejam aplicadas na totalidade ou não, a empresa Mundotêxtil pode enfrentar o futuro com mais confiança podendo estar preparada para fazer face à escassez de água e custos cada vez maiores da energia. Por outro lado pode tratar os seus efluentes a custos menores. A substituição das máquinas de tingimento por máquinas com relação de banho mais baixa (banho curto) implica investimentos elevados mas estes investimentos são necessários não só por motivos ambientais mas também devido à grande competitividade dos mercados.
Resumo:
In a “perfect” drinking water system, the water quality for the consumers should be the same as the quality of the water leaving the treatment plant. However, some variability along the system can lead to a decrease in water quality (such as discolouration) which is usually reflected in the number of the customer complaints. This change may be related to the amount of sediment in the distribution network, leading to an increase in turbidity at the water supply. Since there is no such thing as a perfect drinking water system, the behaviour of particles in a drinking water network needs a suitable approach in order to understand how it works. Moreover, the combination of measurements, such as turbidity patterns and the Resuspension Potential Method (RPM) aid in the prevention of discoloured water complaints and intervention in the treatment upgrade or the network cleaning. Besides sediments there is also bacterial regrowth in the network, which is related to the water quality and distribution network characteristics. In a theoretical drinking water system higher velocities, temperature and shorter residences times lead to wider bacterial growth. In this study we observe velocity and residence steady-states and bacterial does not seem to be related to either. It can be concluded that adequate measurements of RPM, customer complaints and bacterial concentrations allow a wider knowledge on particle behaviour in drinking water systems.
Resumo:
Trabalho Final de Mestrado para obtenção do grau de Mestre em Engenharia Mecânica
Resumo:
Video poker machines, a former symbol of fraud and gambling in Brazil, are now being converted into computer-based educational tools for Brazilian public primary schools and also for governmental and non-governmental institutions dealing with communities of poverty and social exclusion, in an attempt to reduce poverty risks (decrease money spent on gambling) and promote social inclusion (increase access and motivation to education). Thousands of illegal gambling machines are seized by federal authorities, in Brazil, every year, and usually destroyed at the end of the criminal apprehension process. This paper describes a project developed by the University of Southern Santa Catarina, Brazil, responsible for the conversion process of gambling machines, and the social inclusion opportunities derived from it. All project members worked on a volunteer basis, seeking to promote social inclusion of Brazilian young boys and girls, namely through digital inclusion. So far, the project has been able to convert over 200 gambling machines and install them in over 40 public primary schools, thus directly benefiting more than 12,000 schoolchildren. The initial motivation behind this project was technology based, however the different options arising from the conversion process of the gambling machines have also motivated a rather innovative and unique experience in allowing schoolchildren and young people with special (educational) needs to access to computer-based pedagogical applications. The availability of these converted machines also helps to place Information and Communication Technologies (ICT) in the very daily educational environment of these children and youngsters, thus serving social and cultural inclusion aspects, by establishing a dialogue with the community and their technological expectations, and also directly contributing to their digital literacy.
Resumo:
Hydraulic systems are dynamically susceptible in the presence of entrapped air pockets, leading to amplified transient reactions. In order to model the dynamic action of an entrapped air pocket in a confined system, a heuristic mathematical formulation based on a conceptual analogy to a mechanical spring-damper system is proposed. The formulation is based on the polytropic relationship of an ideal gas and includes an additional term, which encompasses the combined damping effects associated with the thermodynamic deviations from the theoretical transformation, as well as those arising from the transient vorticity developed in both fluid domains (air and water). These effects represent the key factors that account for flow energy dissipation and pressure damping. Model validation was completed via numerical simulation of experimental measurements.
Resumo:
Hydraulic binders play a vital role in the economic and social development because they are essential components of concrete, the most widely used construction material. Nowadays, Portland cement is the most predominantly used hydraulic binder due to its properties and widespread availability. Cement manufacture consumes large amount of non-renewable raw materials and energy, and it is a carbon-intensive process. Many efforts are, therefore, being undertaken towards the developing “greener” hydraulic binders. Concomitantly, binders must also correspond to market demand in terms of performance and aesthetic as well as fulfill mandatory regulations. In order to pursue these goals, different approaches have been followed including the improvement of the cement manufacturing process, production of blended cements, and testing innovative hydraulic binders with a different chemistry. This chapter presents a brief history of hydraulic binder’s discovery and use as well as the environmental and economic context of cement industry. It, then, describes the chemistry and properties of currently most used hydraulic binders—common cements and hydraulic limes—and that of the more promising binders for future applications, namely special Portland cements, aluminous cements, calcium sulfoaluminate cements, and alkali-activated cements.
Resumo:
Energy systems worldwide are complex and challenging environments. Multi-agent based simulation platforms are increasing at a high rate, as they show to be a good option to study many issues related to these systems, as well as the involved players at act in this domain. In this scope the authors’ research group has developed a multi-agent system: MASCEM (Multi- Agent System for Competitive Electricity Markets), which simulates the electricity markets environment. MASCEM is integrated with ALBidS (Adaptive Learning Strategic Bidding System) that works as a decision support system for market players. The ALBidS system allows MASCEM market negotiating players to take the best possible advantages from the market context. This paper presents the application of a Support Vector Machines (SVM) based approach to provide decision support to electricity market players. This strategy is tested and validated by being included in ALBidS and then compared with the application of an Artificial Neural Network, originating promising results. The proposed approach is tested and validated using real electricity markets data from MIBEL - Iberian market operator.