933 resultados para Horizontal condominiums


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The pursuit-evasion problem of two aircraft in a horizontal plane is modelled as a zerosum differential game with capture time as payoff. The aircraft are modelled as point masses with thrust and bank angle controls. The games of kind and degree for this differential game are solved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The planform structure of turbulent free convection over a heated horizontal surface has been visualized and analyzed for different boundary conditions at the top and for different aspect ratios, for flux Rayleigh numbers ranging from 10 exp 8 - 10 exp 10. The different boundary conditions correspond to Rayleigh-Benard convection, open convection with evaporation at the top and with an imposed external flow on the heated boundary. Without the external flow the planform is one randomly oriented line plume. At large Ra, these line plumes seem to align along the diagonal, persumably due to a large-scale flow along as visualized in the side view. When the external flow is imposed, the line plumes clearly align in the direction of external flow. Flow visualization reveals that at these Ra, the shear tends to break the plumes which otherwise would reach the opposite boundary. (Author)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study investigates the free convection and plumes dynamics over horizontal surfaces with parallel V-grooves. The convection is studied in a tank of water with the bottom surface being a smooth or grooved surface and the top of the water surface exposed to ambient. Two groove heights were used-10 mm and 3 mm-and the experiment was done with two values of aspect ratio-2.9 and 1.8 (aspect ratio is the width of the fluid layer/height of fluid layer). Heat flux at the bottom surface was from electrical heating. Beyond a certain critical temperature difference, enhanced heat transfer is obtained on the grooved surface compared to a smooth surface. Nusselt numbers are evaluated for both smooth and grooved surfaces and correlated using modified Rayleigh numbers. Visualization shows that the enhanced heat transport in the rough cavities cannot be ascribed to the increase in the contact area; rather, it must be the local dynamics of the thermal boundary layer.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Moist stratified turbulence is studied in a two-dimensional Boussinesq system influenced by condensation and evaporation. The problem is set in a periodic domain and employs simple evaporation and condensation schemes, wherein both the processes push parcels towards saturation. Numerical simulations demonstrate the emergence of a moist turbulent state consisting of ordered structures with a clear power-law type spectral scaling from initially spatially uncorrelated conditions. An asymptotic analysis in the limit of rapid condensation and strong stratification shows that, for initial conditions with enough water substance to saturate the domain, the equations support a straightforward state of moist balance characterized by a hydrostatic, saturated, vertically sheared horizontal flow (VSHF). For such initial conditions, by means of long time numerical simulations, the emergence of moist balance is verified. Specifically, starting from uncorrelated data, subsequent to the development of a moist turbulent state, the system experiences a rather abrupt transition to a regime which is close to saturation and dominated by a strong VSHF. On the other hand, initial conditions which do not have enough water substance to saturate the domain, do not attain moist balance. Rather, the system is observed to remain in a turbulent state and oscillates about moist balance. Even though balance is not achieved with these general initial conditions, the time scale of oscillation about moist balance is much larger than the imposed time scale of condensation and evaporation, thus indicating a distinct dominant slow component in the moist stratified two-dimensional turbulent system. (C) 2012 American Institute of Physics. [http://dx.doi.org/10.1063/1.3694805]

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The present paper discusses the flow visualization for turbulent free convection in a tank of water with the bottom surface being a smooth or a grooved surface and the top of the water surface exposed to ambient. The grooved surface is of parallel 90 degrees V-grooves with groove height of 10 mm and groove width of 20 mm. The experiment is carried out with aspect ratio (AR) of 2.9 and Rayleigh number (Ra) in the range, 1.3 x 10(7) - 4 x 10(7). Here AR is the aspect ratio (= width of fluid layer/height of fluid layer). Heat flux at the bottom surface is from electrical heating. From the pH-dye visualization, interesting flow structures are observed and these structures are analyzed with the help of plumes dynamics and temperature variations with time. (C) 2011 Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The horizontal pullout capacity of a group of two vertical strip plate anchors, placed along the same vertical plane, in a fully cohesive soil has been computed by using the lower bound finite element limit analysis. The effect of spacing between the plate anchors on the magnitude of total group failure load (P-uT) has been evaluated. An increase of soil cohesion with depth has also been incorporated in the analysis. For a weightless medium, the total pullout resistance of the group becomes maximum corresponding to a certain optimum spacing between the anchor plates which has been found to vary generally between 0.5B and B; where B is the width of the anchor plate. As compared to a single plate anchor, the increase in the pullout resistance for a group of two anchors becomes greater at a higher embedment ratio. The effect of soil unit weight has also been analyzed. It is noted that the interference effect on the pullout resistance increases further with an increase in the unit weight of soil mass.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The horizontal pullout capacity of a group of two vertical strip anchors placed along the same vertical plane in sand has been determined by using the upper bound finite elements limit analysis. The variation of the efficiency factor (xi (gamma) ) with changes in clear spacing (S) between the anchors has been established to evaluate the total group failure load for different values of (i) embedment ratio (H/B), (ii) soil internal friction angle (phi), and (iii) anchor-soil interface friction angle (delta). The total group failure load, for a given H/B, becomes always maximum corresponding to a certain optimal spacing (S-opt). The value of S-opt/B was found to lie in a range of 0.5-1.4. The maximum magnitude of xi (gamma) increases generally with increases in H/B, phi and delta.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The vertical uplift resistance of two closely spaced horizontal strip plate anchors has been investigated by using lower and upper bound theorems of the limit analysis in combination with finite elements and linear optimization. The interference effect on uplift resistance of the two anchors is evaluated in terms of a nondimensional efficiency factor (eta(c)). The variation of eta(c) with changes in the clear spacing (S) between the two anchors has been established for different combinations of embedment ratio (H/B) and angle of internal friction of the soil (phi). An interference of the anchors leads to a continuous reduction in uplift resistance with a decrease in spacing between the anchors. The uplift resistance becomes a minimum when the two anchors are placed next to each other without any gap. The critical spacing (S-cr) between the two anchors required to eliminate the interference effect increases with an increase in the values of both H/B and phi. The value of S-cr was found to lie approximately in the range 0.65B-1.5B with H/B = 1 and 11B-14B with H/B = 7 for phi varying from 0 degrees to 30 degrees.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

With an application of the upper bound finite element limit analysis, the vertical pullout capacity of a group of two horizontal strip plate anchors, with the common vertical axis and placed in a cohesive-frictional soil, has been computed. The variation of the uplift factors Fc, Fq and Fy, due to the contributions of soil cohesion, surcharge pressure and unit weight, respectively, has been evaluated for different combinations of S/B and H/B. As compared to single isolated anchor, the group of two anchors generates significantly greater magnitude of Fc for Φ ≤ 20° especially with greater values of H/B and under fully bonded anchor-soil interface condition. The factor Fc attains almost the maximum value when the upper anchor plate is placed midway between ground surface and the lower anchor plate. The factors Fq and Fy, on the other hand, for a group of two anchors are found to remain almost equal to that of a single isolated anchor as long as the levels of the lower plate in the group and the single isolated anchor are kept the same.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Three-dimensional natural convection in a horizontal channel with an array of discrete flush-mounted heaters on one of its vertical walls is numerically studied. Effects of thermal conductivities of substrate and heaters and convection on outer sides of the channel walls on heat transfer are examined. The substrate affects heat transfer in a wider range of thermal conductivities than do the heaters. At lower heater thermal conductivities a higher heat portion is transferred by direct convection from the heaters to the adjacent coolant. However, higher substrate conductivity is associated with higher heat portion transferred through the substrate. The innermost heater column is found to become the hottest heater column due to the lower coolant accessibility. The heat transfer in the channel is strongly influenced by convection on the outer sides of the channel walls. Correlations are presented for dimensionless temperature maximum and average Nusselt number.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The vertical uplift resistance of two interfering rigid strip plate anchors embedded horizontally at the same level in clay has been examined. The lower and upper bound theorems of the limit analysis in combination with finite-elements and linear optimization have been employed to compute the failure load in a bound form. The analysis is meant for an undrained condition and it incorporates the increase of cohesion with depth. For different clear spacing (S) between the anchors, the magnitude of the efficiency factor (eta c gamma) resulting from the combined components of soil cohesion (c) and soil unit weight (gamma), has been computed for different values of embedment ratio (H/B), the rate of linear increase of cohesion with depth (m) and normalized unit weight (gamma H/c). The magnitude of eta c gamma has been found to reduce continuously with a decrease in the spacing between the anchors, and the uplift resistance becomes minimum for S/B=0. It has been noted that the critical spacing between the anchors required to eliminate the interference effect increases continuously with (1) an increase in H/B, and (2) a decrease in m.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We investigated the site response characteristics of Kachchh rift basin over the meizoseismal area of the 2001, Mw 7.6, Bhuj (NW India) earthquake using the spectral ratio of the horizontal and vertical components of ambient vibrations. Using the available knowledge on the regional geology of Kachchh and well documented ground responses from the earthquake, we evaluated the H/V curves pattern across sediment filled valleys and uplifted areas generally characterized by weathered sandstones. Although our HIV curves showed a largely fuzzy nature, we found that the hierarchical clustering method was useful for comparing large numbers of response curves and identifying the areas with similar responses. Broad and plateau shaped peaks of a cluster of curves within the valley region suggests the possibility of basin effects within valley. Fundamental resonance frequencies (f(0)) are found in the narrow range of 0.1-2.3 Hz and their spatial distribution demarcated the uplifted regions from the valleys. In contrary, low HIV peak amplitudes (A(0) = 2-4) were observed on the uplifted areas and varying values (2-9) were found within valleys. Compared to the amplification factors, the liquefaction indices (kg) were able to effectively indicate the areas which experienced severe liquefaction. The amplification ranges obtained in the current study were found to be comparable to those obtained from earthquake data for a limited number of seismic stations located on uplifted areas; however the values on the valley region may not reflect their true amplification potential due to basin effects. Our study highlights the practical usefulness as well as limitations of the HIV method to study complex geological settings as Kachchh. (C) 2014 Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The Electrical Resistance Tomography (ERT) technique possesses great potential in monitoring widely exiting industrial two/multi-phase flow. For vertical pipe flow and inclined pipe flow, some application studies with exciting results have been reported, but there is rarely a paper regarding the application of ERT to horizontal gas/liquid pipe flow. This paper addresses this issue and proposes a smart method, Liquid Level Detection method, to conventional ERT system. The enhanced ERT system using the new method can monitor horizontal pipe flow effectively and its application is no longer restricted by the flow conditions. Some experimental results from monitoring an air/water slug pipe flow are presented.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Centrifuge experiments are carried out to investigate the responses of suction bucket foundations under horizontal dynamic loading. The effects of loading amplitude, the size of the bucket and the structural weight on the dynamic responses are investigated. It is shown that, when the loading amplitude is over a critical value, the sand at the upper part around the bucket softens or even liquefies. The liquefactio...