867 resultados para Hip joint


Relevância:

70.00% 70.00%

Publicador:

Resumo:

OBJECTIVE: To compare the existence of radiographic abnormalities in two groups of patients, those with and without hip pain. METHODS: A total 222 patients were evaluated between March 2007 and April 2009; 122 complained of groin pain, and 100 had no symptoms. The individuals in both groups underwent radiographic examinations of the hip using the following views: anteroposterior, Lequesne false profile, Dunn, Dunn 45º, and Ducroquet. RESULTS: A total of 1110 radiographs were evaluated. Female patients were prevalent in both groups (52% symptomatic, 58% asymptomatic). There were statistically significant differences between the groups in age (p<0.0001), weight (p = 0.002) and BMI (p = 0.006). The positive findings in the group with groin pain consisted of the presence of a bump on the femoral head in the anteroposterior view (p<0.0001) or in the Dunn 45º view (p = 0.008). The difference in the a angle in the anteroposterior, Dunn, Dunn 45º, and Ducroquet views for all of the cases studied was p,0.0001. The joint space measurement differed significantly between groups in the Lequesne view (p = 0.007). The Lequesne anteversion angle (ρ) and the femoral offset measurement also differed significantly (p = 0.005 and p = 0.0001, respectively). CONCLUSIONS: We conclude that the best views for diagnosing a femoroacetabular impingement are the anteroposterior pelvic orthostatic, the Dunn 45º, and the Ducroquet views. The following findings correlated with hip pain: a decrease in the femoral offset, an increase in the α angle, an increase in the Lequesne ρ angle, a decrease in the CE angle of Wiberg, a thinner articular space and the presence of a bump on the femoral head-neck transition.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Background. The surgical treatment of dysfunctional hips is a severe condition for the patient and a costly therapy for the public health. Hip resurfacing techniques seem to hold the promise of various advantages over traditional THR, with particular attention to young and active patients. Although the lesson provided in the past by many branches of engineering is that success in designing competitive products can be achieved only by predicting the possible scenario of failure, to date the understanding of the implant quality is poorly pre-clinically addressed. Thus revision is the only delayed and reliable end point for assessment. The aim of the present work was to model the musculoskeletal system so as to develop a protocol for predicting failure of hip resurfacing prosthesis. Methods. Preliminary studies validated the technique for the generation of subject specific finite element (FE) models of long bones from Computed Thomography data. The proposed protocol consisted in the numerical analysis of the prosthesis biomechanics by deterministic and statistic studies so as to assess the risk of biomechanical failure on the different operative conditions the implant might face in a population of interest during various activities of daily living. Physiological conditions were defined including the variability of the anatomy, bone densitometry, surgery uncertainties and published boundary conditions at the hip. The protocol was tested by analysing a successful design on the market and a new prototype of a resurfacing prosthesis. Results. The intrinsic accuracy of models on bone stress predictions (RMSE < 10%) was aligned to the current state of the art in this field. The accuracy of prediction on the bone-prosthesis contact mechanics was also excellent (< 0.001 mm). The sensitivity of models prediction to uncertainties on modelling parameter was found below 8.4%. The analysis of the successful design resulted in a very good agreement with published retrospective studies. The geometry optimisation of the new prototype lead to a final design with a low risk of failure. The statistical analysis confirmed the minimal risk of the optimised design over the entire population of interest. The performances of the optimised design showed a significant improvement with respect to the first prototype (+35%). Limitations. On the authors opinion the major limitation of this study is on boundary conditions. The muscular forces and the hip joint reaction were derived from the few data available in the literature, which can be considered significant but hardly representative of the entire variability of boundary conditions the implant might face over the patients population. This moved the focus of the research on modelling the musculoskeletal system; the ongoing activity is to develop subject-specific musculoskeletal models of the lower limb from medical images. Conclusions. The developed protocol was able to accurately predict known clinical outcomes when applied to a well-established device and, to support the design optimisation phase providing important information on critical characteristics of the patients when applied to a new prosthesis. The presented approach does have a relevant generality that would allow the extension of the protocol to a large set of orthopaedic scenarios with minor changes. Hence, a failure mode analysis criterion can be considered a suitable tool in developing new orthopaedic devices.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Nowadays the number of hip joints arthroplasty operations continues to increase because the elderly population is growing. Moreover, the global life expectancy is increasing and people adopt a more active way of life. For this reasons, the demand of implant revision operations is becoming more frequent. The operation procedure includes the surgical removal of the old implant and its substitution with a new one. Every time a new implant is inserted, it generates an alteration in the internal femur strain distribution, jeopardizing the remodeling process with the possibility of bone tissue loss. This is of major concern, particularly in the proximal Gruen zones, which are considered critical for implant stability and longevity. Today, different implant designs exist in the market; however there is not a clear understanding of which are the best implant design parameters to achieve mechanical optimal conditions. The aim of the study is to investigate the stress shielding effect generated by different implant design parameters on proximal femur, evaluating which ranges of those parameters lead to the most physiological conditions.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Traumatic posterior dislocation of the hip associated with a fracture of the posterior acetabular wall and of the neck of the femur is a rare injury. A 29-year-old man presented at a level 1 trauma centre with a locked posterior dislocation of the right hip, with fractures of the femoral neck and the posterior wall of the acetabulum after a bicycle accident. An attempted closed reduction had failed. This case report describes in detail the surgical management and the clinical and radiological outcome. Open reduction and fixation with preservation of the intact retinaculum was undertaken within five hours of injury with surgical dislocation of the hip and a trochanteric osteotomy. Two years after operation the function of the injured hip was good. Plain radiographs and MR scans showed early signs of osteoarthritis with some loss of joint space but no evidence of avascular necrosis. The patient had begun skiing and hiking again. The combination of fractures of the neck of the femur and of the posterior wall of the acetabulum hampers closed reduction of a posterior dislocation of the hip. Surgical dislocation of the hip with trochanteric flip osteotomy allows controlled open reduction of the fractures, with inspection of the hip joint and preservation of the vascular supply.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Osteoarthritis of the hip joint is caused by a combination of intrinsic factors and extrinsic factors. Different surgical techniques are being performed to delay or halt osteoarthritis. Success of salvage procedures of the hip depends on the existing cartilage and joint damage before surgery; the likelihood of therapy failure rises with advanced osteoarthritis. For imaging of intra-articular hip pathology, MR imaging represents the best technique because of its ability to directly visualize cartilage, superior soft tissue contrast, and the prospect of multidimensional imaging. This article gives an overview on the standard MR imaging techniques used for diagnosis of hip osteoarthritis and their implications for surgery.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Successful treatment of prosthetic hip joint infection (PI) means elimination of infection and restored hip function. However, functional outcome is rarely studied. We analyzed the outcome of the strict use of a treatment algorithm for PI.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Traumatic anterior dislocation of the hip joint is rare. Additional injuries to the hip due to dislocation are even more infrequent. Outcome is limited by osteoarthritic joint degeneration or the occurrence of avascular necrosis of the femoral head.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

To characterize the zonal distribution of three-dimensional (3D) T1 mapping in the hip joint of asymptomatic adult volunteers.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Background Leg length inequality (LLI) was identified as a problem of total hip arthroplasty soon after its introduction. Leg lengthening is the most common form of LLI. Possible consequences are limping, neuronal dysfunction and aseptic component loosening. LLI can result in an increased strain both on the contralateral hip joint and on the abductor muscles. We assessed the influence of leg lengthening and shortening on walking capacity, hip pain, limping and patient satisfaction at 2-year follow-up. Methods 478 cases with postoperative lengthening and 275 with shortening were identified, and matched with three controls each. Rigorous adjustment for potential differences in baseline patient characteristics was performed by propensity-score matching of covariates. The arbitrarily defined desired outcomes were a walking capacity >60 minutes, no hip pain, no limping, and excellent patient satisfaction. Differences in not achieving the desired outcomes between the groups were expressed as odds ratios. Results In the lengthened case group, the odds ratio for not being able to walk for an hour was 1.70 (95% CI 1.28-2.26) for cases compared to controls, and the odds ratio for having hip pain at follow-up was 1.13 (95% CI 0.78-1.64). The odds ratio for limping was 2.08 (95% CI 1.55-2.80). The odds ratio for not achieving excellent patient satisfaction was 1.67 (95% CI 1.23-2.28). In the shortening case group, the odds ratio for not being able to walk for an hour was 1.23 (95% CI 0.84-1.81), and the odds ratio for having hip pain at follow-up was 1.60 (95% CI 1.05-2.44). The odds ratio for limping for cases was 2.61 (95% CI 1.78-3.21). The odds ratio for not achieving excellent patient satisfaction was 2.15 (95% CI 1.44-3.21). Conclusions Walking capacity, limping and patient satisfaction were all significantly associated with leg lengthening, whereas pain alleviation was not. In contrast, hip pain, limping and patient satisfaction were all significantly associated with leg shortening, whereas walking capacity was not.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Placing portal incisions during arthroscopic hip surgery presents challenges for surgeons in terms of anatomic accessibility and patient safety. Based on key anatomic landmarks and portal placement information from recent literature, suggested portal incisions were determined. Guidance in the placement of the three most common portal incision locations (anterior, anterolateral, and posterolateral) for arthroscopic surgery; in addition to visual feedback on tool trajectory to the hip joint is provided in real time by a computer aided system for hip arthroscopy. By simplifying the portal placement process, one of the most challenging aspects of arthroscopic hip surgery, an increased use of this minimally invasive technique could be possible. In addition to portal information, improvements to an existing computer aided system for arthroscopic hip surgery, including a new hip model and redesigned mechanical tracking linkage, were completed.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

While beneficially decreasing the necessary incision size, arthroscopic hip surgery increases the surgical complexity due to loss of joint visibility. To ease such difficulty, a computer-aided mechanical navigation system was developed to present the location of the surgical tool relative to the patient¿s hip joint. A preliminary study reduced the position error of the tracking linkage with limited static testing trials. In this study, a correction method, including a rotational correction factor and a length correction function, was developed through more in-depth static testing. The developed correction method was then applied to additional static and dynamic testing trials to evaluate its effectiveness. For static testing, the position error decreased from an average of 0.384 inches to 0.153 inches, with an error reduction of 60.5%. Three parameters utilized to quantify error reduction of dynamic testing did not show consistent results. The vertex coordinates achieved 29.4% of error reduction, yet with large variation in the upper vertex. The triangular area error was reduced by 5.37%, however inconsistent among all five dynamic trials. Error of vertex angles increased, indicating a shape torsion using the developed correction method. While the established correction method effectively and consistently reduced position error in static testing, it did not present consistent results in dynamic trials. More dynamic paramters should be explored to quantify error reduction of dynamic testing, and more in-depth dynamic testing methodology should be conducted to further improve the accuracy of the computer-aided nagivation system.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Magnetic resonance imaging (MRI) is the most promising noninvasive modality for hip joint evaluation, but it has limitations in diagnosing cartilage lesion and acetabular labrum changes, especially in early stages. This is significant due to superior outcome results of surgery intervention in hip dysplasia or femoroacetabular impingement in patients not exceeding early degeneration. This emphasizes the need for accurate and reproducible methods in evaluating cartilage structure. In this article, we discuss the impact of the most recent technological advance in MRI, namely the advantage of 3-T imaging, on diagnostic imaging of the hip. Limitations of standard imaging techniques are shown with emphasis on femoroacetabular impingement. Clinical imaging examples and biochemical techniques are presented that need to be further evaluated.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Osteotomies of the proximal femur for hip joint conditions are normally done at the intertrochanteric or subtrochanteric level. Intra-articular osteotomies would be more direct and therefore allow a more powerful correction with no or very little undesired side correction. However, concerns about the risk of vascular damage and osteonecrosis of the femoral head have so far basically excluded this technique from practical use. Based on detailed knowledge of the vascular anatomy of the proximal femur, an approach to safely dislocate the femoral head has been described and successfully performed. Experience as well as further studies of femoral head perfusion allowed a substantial extension of this approach, with subperiosteal exposure of the circumference of the femoral neck with constant intraoperative control of the blood supply to the head. Using the extended retinacular soft-tissue flap, four surgical techniques (relative neck lengthening, subcapital realignment in slipped capital femoral epiphysis, true femoral neck osteotomy, and femoral head reduction osteotomy) evolved or became safer with respect to perfusion of the femoral head. The extended retinacular soft-tissue flap offers the technical and biologic possibility for a new class of intra articular procedures. Although meticulous execution of the surgical steps is important, the procedures have a high level of safety for femoral head perfusion.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

OBJECTIVE: Anatomic reduction and stable fixation by means of tissue- preserving surgical approaches. INDICATIONS Displaced acetabular fractures. Surgical hip dislocation approach with larger displacement of the posterior column in comparison to the anterior column, transtectal fractures, additional intraarticular fragments, marginal impaction. Stoppa approach with larger displacement of the anterior column in comparison to the posterior column. A combined approach might be necessary with difficult reduction. CONTRAINDICATIONS Fractures > 15 days (then ilioinguinal or extended iliofemoral approaches). Suprapubic catheters and abdominal problems (e.g., previous laparotomy due to visceral injuries) with Stoppa approach (then switch to classic ilioinguinal approach). SURGICAL TECHNIQUE: Surgical hip dislocation: lateral decubitus position. Straight lateral incision centered over the greater trochanter. Entering of the Gibson interval. Digastric trochanteric osteotomy with protection of the medial circumflex femoral artery. Opening of the interval between the piriformis and the gluteus minimus muscle. Z-shaped capsulotomy. Dislocation of the femoral head. Reduction and fixation of the posterior column with plate and screws. Fixation of the anterior column with a lag screw in direction of the superior pubic ramus. Stoppa approach: supine position. Incision according to Pfannenstiel. Longitudinal splitting of the anterior portion of the rectus sheet and the rectus abdominis muscle. Blunt dissection of the space of Retzius. Ligation of the corona mortis, if present. Blunt dissection of the quadrilateral plate and the anterior column. Reduction of the anterior column and fixation with a reconstruction plate. Fixation of the posterior column with lag screws. If necessary, the first window of the ilioinguinal approach can be used for reduction and fixation of the posterior column. POSTOPERATIVE MANAGEMENT: During hospital stay, intensive mobilization of the hip joint using a continuous passive motion machine with a maximum flexion of 90 degrees . No active abduction and passive adduction over the body's midline, if a surgical dislocation was performed. Maximum weight bearing 10-15 kg for 8 weeks. Then, first clinical and radiographic follow-up. Deep venous thrombosis prophylaxis for 8 weeks postoperatively. RESULTS: 17 patients with a mean follow-up of 3.2 years. Ten patients were operated via surgical hip dislocation, two patients with a Stoppa approach, and five using a combined or alternative approach. Anatomic reduction was achieved in ten of the twelve patients (83%) without primary total hip arthroplasty. Mean operation time 3.3 h for surgical hip dislocation and 4.2 h for the Stoppa approach. Complications comprised one delayed trochanteric union, one heterotopic ossification, and one loss of reduction. There were no cases of avascular necrosis. In two patients, a total hip arthroplasty was performed due to the development of secondary hip osteoarthritis.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Osteoarthritis (OA) of the hip joint stems from a combination of intrinsic factors, such as joint anatomy, and extrinsic factors, such as injuries, diseases, and load. Possible risk factors for OA are instability and impingement. Different surgical techniques, such as osteotomies of the pelvis and femur, surgical dislocation, and hip arthroscopy, are being performed to delay or halt OA. Success of salvage procedures of the hip depends on the existing cartilage and joint damage before surgery. The likelihood of therapy failure rises with advanced OA. For imaging of intra-articular hip pathology, MRI represents the best technique because it enables clinicians to directly visualize cartilage, it provides superior soft tissue contrast, and it offers the prospect of multidimensional imaging. However, opinions differ on the diagnostic efficacy of MRI and on the question of which MRI technique is most appropriate. This article gives an overview of the standard MRI techniques for diagnosis of hip OA and their implications for surgery.