945 resultados para Heat warning system


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Regular and systematic monitoring of drug markets provides the basis for evidence-based policy. In Australia, trends in ecstasy and related drug (ERD) markets have been monitored in selected jurisdictions since 2000 and nationally since 2003, by the Party Drugs Initiative (PDI). The PDI maximises the validity of conclusions by triangulating information from (a) interviews with regular ecstasy users (REU), (b) interviews with key experts and (c) indicator data. There is currently no other system in Australia for monitoring these markets systematically; however, the value of the PDI has been constrained by the quality of available data. Difficulties in recruiting and interviewing appropriate consumers (REU) and key experts have been experienced, but largely overcome. Limitations of available indicator data from both health and law enforcement continue to present challenges and there remains considerable scope for enhancing existing routine data collection systems, to facilitate monitoring of ERD markets. With an expanding market for ecstasy and related drugs in Australia, and in the context of indicator data that continue to be limited in scope and detail, there is a strong argument for the continued collection of annual, comparable data from a sentinel group of REU, such as those recruited for the PDI.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A study on heat pump thermodynamic characteristics has been made in the laboratory on a specially designed and instrumented air to water heat pump system. The design, using refrigerant R12, was based on the requirement to produce domestic hot water at a temperature of about 50 °C and was assembled in the laboratory. All the experimental data were fed to a microcomputer and stored on disk automatically from appropriate transducers via amplifier and 16 channel analogue to digital converters. The measurements taken were R12 pressures and temperatures, water and R12 mass flow rates, air speed, fan and compressor input powers, water and air inlet and outlet temperatures, wet and dry bulb temperatures. The time interval between the observations could be varied. The results showed, as expected, that the COP was higher at higher air inlet temperatures and at lower hot water output temperatures. The optimum air speed was found to be at a speed when the fan input power was about 4% of the condenser heat output. It was also found that the hot water can be produced at a temperature higher than the appropriate R12 condensing temperature corresponding to condensing pressure. This was achieved by condenser design to take advantage of discharge superheat and by further heating the water using heat recovery from the compressor. Of the input power to the compressor, typically about 85% was transferred to the refrigerant, 50 % by the compression work and 35% due to the heating of the refrigerant by the cylinder wall, and the remaining 15% (of the input power) was rejected to the cooling medium. The evaporator effectiveness was found to be about 75% and sensitive to the air speed. Using the data collected, a steady state computer model was developed. For given input conditions s air inlet temperature, air speed, the degree of suction superheat , water inlet and outlet temperatures; the model is capable of predicting the refrigerant cycle, compressor efficiency, evaporator effectiveness, condenser water flow rate and system Cop.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Faced with a future of rising energy costs there is a need for industry to manage energy more carefully in order to meet its economic objectives. A problem besetting the growth of energy conservation in the UK is that a large proportion of energy consumption is used in a low intensive manner in organisations where they would be responsibility for energy efficiency is spread over a large number of personnel who each see only small energy costs. In relation to this problem in the non-energy intensive industrial sector, an application of an energy management technique known as monitoring and targeting (M & T) has been installed at the Whetstone site of the General Electric Company Limited in an attempt to prove it as a means for motivating line management and personnel to save energy. The objective energy saving for which the M & T was devised is very specific. During early energy conservation work at the site there had been a change from continuous to intermittent heating but the maintenance of the strategy was receiving a poor level of commitment from line management and performance was some 5% - 10% less than expected. The M & T is concerned therefore with heat for space heating for which a heat metering system was required. Metering of the site high pressure hot water system posed technical difficulties and expenditure was also limited. This led to a ‘tin-house' design being installed for a price less than the commercial equivalent. The timespan of work to achieve an operational heat metering system was 3 years which meant that energy saving results from the scheme were not observed during the study. If successful the replication potential is the larger non energy intensive sites from which some 30 PT savings could be expected in the UK.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Institutions have implemented many campus interventions to address student persistence/retention, one of which is Early Warning Systems (EWS). However, few research studies show evidence of interventions that incorporate noncognitive factors/skills, and psychotherapy/psycho-educational processes in the EWS. A qualitative study (phenomenological interview and document analysis) of EWS at both a public and private 4-year Florida university was conducted to explore EWS through the eyes of the administrators of the ways administrators make sense of students' experiences and the services they provide and do not provide to assist students. Administrators' understanding of noncognitive factors and the executive skills subset and their contribution to retention and the executive skills development of at-risk students were also explored. Hossler and Bean's multiple retention lenses theory/paradigms and Perez's retention strategies were used to guide the study. Six administrators from each institution who oversee and/or assist with EWS for first time in college undergraduate students considered academically at-risk for attrition were interviewed. Among numerous findings, at Institution X: EWS was infrequently identified as a service, EWS training was not conducted, numerous cognitive and noncognitive issues/deficits were identified for students, and services/critical departments such as EWS did not work together to share students' information to benefit students. Assessment measures were used to identify students' issues/deficits; however, they were not used to assess, track, and monitor students' issues/deficits. Additionally, the institution's EWS did address students' executive skills function beyond time management and organizational skills, but did not address students' psychotherapy/psycho-educational processes. Among numerous findings, at Institution Y: EWS was frequently identified as a service, EWS training was not conducted, numerous cognitive and noncognitive issues/deficits were identified for students, and services/critical departments such as EWS worked together to share students' information to benefit students. Assessment measures were used to identify, track, and monitor students' issues/deficits; however, they were not used to assess students' issues/deficits. Additionally, the institution's EWS addressed students' executive skills function beyond time management and organizational skills, and psychotherapy/psycho-educational processes. Based on the findings, Perez's retention strategies were not utilized in EWS at Institution X, yet were collectively utilized in EWS at Institution Y, to achieve Hossler and Bean's retention paradigms. Future research could be designed to test the link between engaging in the specific promising activities identified in this research (one-to-one coaching, participation in student success workshops, academic contracts, and tutoring) and student success (e.g., higher GPA, retention). Further, because this research uncovered some concern with how to best handle students with physical and psychological disabilities, future research could link these same promising strategies for improving student performance for example among ADHD students or those with clinical depression.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The observation chart is for many health professionals (HPs) the primary source of objective information relating to the health of a patient. Information Systems (IS) research has demonstrated the positive impact of good interface design on decision making and it is logical that good observation chart design can positively impact healthcare decision making. Despite the potential for good observation chart design, there is a paucity of observation chart design literature, with the primary source of literature leveraging Human Computer Interaction (HCI) literature to design better charts. While this approach has been successful, this design approach introduces a gap between understanding of the tasks performed by HPs when using charts and the design features implemented in the chart. Good IS allow for the collection and manipulation of data so that it can be presented in a timely manner that support specific tasks. Good interface design should therefore consider the specific tasks being performed prior to designing the interface. This research adopts a Design Science Research (DSR) approach to formalise a framework of design principles that incorporates knowledge of the tasks performed by HPs when using observation charts and knowledge pertaining to visual representations of data and semiology of graphics. This research is presented in three phases, the initial two phases seek to discover and formalise design knowledge embedded in two situated observation charts: the paper-based NEWS chart developed by the Health Service Executive in Ireland and the electronically generated eNEWS chart developed by the Health Information Systems Research Centre in University College Cork. A comparative evaluation of each chart is also presented in the respective phases. Throughout each of these phases, tentative versions of a design framework for electronic vital sign observation charts are presented, with each subsequent iteration of the framework (versions Alpha, Beta, V0.1 and V1.0) representing a refinement of the design knowledge. The design framework will be named the framework for the Retrospective Evaluation of Vital Sign Information from Early Warning Systems (REVIEWS). Phase 3 of the research presents the deductive process for designing and implementing V0.1 of the framework, with evaluation of the instantiation allowing for the final iteration V1.0 of the framework. This study makes a number of contributions to academic research. First the research demonstrates that the cognitive tasks performed by nurses during clinical reasoning can be supported through good observation chart design. Secondly the research establishes the utility of electronic vital sign observation charts in terms of supporting the cognitive tasks performed by nurses during clinical reasoning. Third the framework for REVIEWS represents a comprehensive set of design principles which if applied to chart design will improve the usefulness of the chart in terms of supporting clinical reasoning. Fourth the electronic observation chart that emerges from this research is demonstrated to be significantly more useful than previously designed charts and represents a significant contribution to practice. Finally the research presents a research design that employs a combination of inductive and deductive design activities to iterate on the design of situated artefacts.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The internal combustion (IC) engines exploits only about 30% of the chemical energy ejected through combustion, whereas the remaining part is rejected by means of cooling system and exhausted gas. Nowadays, a major global concern is finding sustainable solutions for better fuel economy which in turn results in a decrease of carbon dioxide (CO2) emissions. The Waste Heat Recovery (WHR) is one of the most promising techniques to increase the overall efficiency of a vehicle system, allowing the recovery of the heat rejected by the exhaust and cooling systems. In this context, Organic Rankine Cycles (ORCs) are widely recognized as a potential technology to exploit the heat rejected by engines to produce electricity. The aim of the present paper is to investigate a WHR system, designed to collect both coolant and exhausted gas heats, coupled with an ORC cycle for vehicle applications. In particular, a coolant heat exchanger (CLT) allows the heat exchange between the water coolant and the ORC working fluid, whereas the exhausted gas heat is recovered by using a secondary circuit with diathermic oil. By using an in-house numerical model, a wide range of working conditions and ORC design parameters are investigated. In particular, the analyses are focused on the regenerator location inside the ORC circuits. Five organic fluids, working in both subcritical and supercritical conditions, have been selected in order to detect the most suitable configuration in terms of energy and exergy efficiencies.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Part 17: Risk Analysis

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Historically, domestic tasks such as preparing food and washing and drying clothes and dishes were done by hand. In a modern home many of these chores are taken care of by machines such as washing machines, dishwashers and tumble dryers. When the first such machines came on the market customers were happy that they worked at all! Today, the costs of electricity and customers’ environmental awareness are high, so features such as low electricity, water and detergent use strongly influence which household machine the customer will buy. One way to achieve lower electricity usage for the tumble dryer and the dishwasher is to add a heat pump system. The function of a heat pump system is to extract heat from a lower temperature source (heat source) and reject it to a higher temperature sink (heat sink) at a higher temperature level. Heat pump systems have been used for a long time in refrigerators and freezers, and that industry has driven the development of small, high quality, low price heat pump components. The low price of good quality heat pump components, along with an increased willingness to pay extra for lower electricity usage and environmental impact, make it possible to introduce heat pump systems in other household products. However, there is a high risk of failure with new features. A number of household manufacturers no longer exist because they introduced poorly implemented new features, which resulted in low quality and product performance. A manufacturer must predict whether the future value of a feature is high enough for the customer chain to pay for it. The challenge for the manufacturer is to develop and produce a high-performance heat pump feature in a household product with high quality, predict future willingness to pay for it, and launch it at the right moment in order to succeed. Tumble dryers with heat pump systems have been on the market since 2000. Paper I reports on the development of a transient simulation model of a commercial heat pump tumble dryer. The measured and simulated results were compared with good similarity. The influence of the size of the compressor and the condenser was investigated using the validated simulation model. The results from the simulation model show that increasing the cylinder volume of the compressor by 50% decreases the drying time by 14% without using more electricity.  Paper II is a concept study of adding a heat pump system to a dishwasher in order to decrease the total electricity usage. The dishwasher, dishware and water are heated by the condenser, and the evaporator absorbs the heat from a water tank. The majority of the heat transfer to the evaporator occurs when ice is generated in the water tank. An experimental setup and a transient simulation model of a heat pump dishwasher were developed. The simulation results show a 24% reduction in electricity use compared to a conventional dishwasher heated with an electric element. The simulation model was based on an experimental setup that was not optimised. During the study it became apparent that it is possible to decrease electricity usage even more with the next experimental setup.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background: This study attempted to develop health risk-based metrics for defining a heatwave in Brisbane, Australia. Methods: Poisson generalised additive model was performed to assess the impact of heatwaves on mortality and emergency hospital admissions (EHAs) in Brisbane. Results: In general, the higher the intensity and the longer the duration of a heatwave, the greater the health impacts. There was no apparent difference in EHAs risk during different periods of a warm season. However, there was a greater risk of mortality in the second half of a warm season than that in the first half. While elderly (>75 years)were particularly vulnerable to both the EHA and mortality effects of a heatwave, the risk for EHAs also significantly increased for two other age groups (0-64 years and 65-74 years) during severe heatwaves. Different patterns between cardiorespiratory mortality and EHAs were observed. Based on these findings, we propose the use of a teiered heat warning system based on the health risk of heatwave. Conclusions: Health risk-based metrics are a useful tool for the development of local heatwave definitions. thsi tool may have significant implications for the assessment of heatwave-related health consequences and development of heatwave response plans and implementation strategies.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In view of the growing global demand for energy and concern expressed for environmental degradation, a clean and "free" energy source, such as solar energy, has been receiving greater attention in recent years for various applications using different techniques. The Direct Expansion Solar Assisted Heat Pump (DX-SAHP) principle is one of the most promising techniques as it makes use of both solar and ambient energy. As the system has capability to function at low temperatures, it has the potential to operate at night in the tropics. The system utilizes multi-effect distillation (MED) principle for the conversion of seawater to fresh water. An experimental setup of the DX-SAHP desalination system has been built at the Department of Mechanical Engineering, National University of Singapore (NUS). This system uses two types of flat-plate solar collectors. One is called evaporator-collector, where no glazing is used, and the efficiency varies between 80 and 90%. The other type of collector is single-glazed, where the maximum efficiency is about 60%, and it is used for feed water heating. For the heat pump cycle, refrigerant R134a is used. The present study provides a comprehensive analyses and performance evaluation of this system under different operating and meteorological conditions of Singapore. The Coefficient of Performance (COP) of the heat pump system reached a maximum value of 10. For a single effect of desalination, the system shows a Performance Ratio (PR) of around 1.3.