897 resultados para HOUSE FLOORS
Resumo:
Current urban development in South East Queensland (SEQ) is impacted by a number of factors: growth and sprawl eroding subtropical character and identity; changing demographics and housing needs; lack of developable land; rising transport costs; diminishing fresh water supply; high energy consumption; and generic building designs which ignore local climate, landscape and lifestyle conditions. The Subtropical Row House project sought to research ‘best practice’ planning and design for contemporary and future needs for urban development in SEQ, and stimulate higher-density housing responses that achieve sustainable, low-energy and low water outcomes and support subtropical character and identity by developing a workable new typology for homes that the local market can adopt. The methodology was that of charrette, an established methodology in architecture and design. Four leading Queensland architectural firms were invited to form multidisciplinary creative teams. During the two-day charrette, the teams visited a selected greenfield site, defined the problems and issues, developed ideas and solutions, and benchmarked performance of designs using the Australian Green Building Council’s Pilot Green Star Multi-Unit residential tool. Each of the four resulting designs simultaneously express a positive relationship with climate and place by demonstrating: suitability for the subtropical climate; flexibility for a diversity of households; integrated building/site/vegetation strategies; market appeal to occupants and developers; affordability in operation; constructability by ‘domestic’ builders; and reduced energy, water and wastage. The project was awarded a Regional Commendation by the Australian Institute of Architects.
Resumo:
Sourcing appropriate funding for the provision of new urban infrastructure has been a policy dilemma for governments around the world for decades. This is particularly relevant in high growth areas where new services are required to support swelling populations. The Australian infrastructure funding policy dilemmas are reflective of similar matters in many countries, particularly the United States of America, where infrastructure cost recovery policies have been in place since the 1970’s. There is an extensive body of both theoretical and empirical literature from these countries that discusses the passing on (to home buyers) of these infrastructure charges, and the corresponding impact on housing prices. The theoretical evidence is consistent in its findings that infrastructure charges are passed on to home buyers by way of higher house prices. The empirical evidence is also consistent in its findings, with “overshifting” of these charges evident in all models since the 1980’s, i.e. $1 infrastructure charge results in greater than $1 increase in house prices. However, despite over a dozen separate studies over two decades in the US on this topic, no empirical works have been carried out in Australia to test if similar shifting or overshifting occurs here. The purpose of this research is to conduct a preliminary analysis of the more recent models used in these US empirical studies in order to identify the key study area selection criteria and success factors. The paper concludes that many of the study area selection criteria are implicit rather than explicit. By collecting data across the models, some implicit criteria become apparent, whilst others remain elusive. This data will inform future research on whether an existing model can be adopted or adapted for use in Australia.
Resumo:
The paper presents the results of a study conducted to investigate indoor air quality within residential dwellings in Lao PDR. Results from PM 10, CO, and NO2 measurements inside 167 dwellings in Lao PDR over a five month period (December 2005-April 2006) are discussed as a function of household characteristics and occupant activities. Extremely high PM10 and NO2 concentrations (12 h mean PM10 concentrations 1275 ± 98 μg m-3 and 1183 ± 99 μg m-3 in Vientiane and Bolikhamxay provinces, respectively; 12 h mean NO2 concentrations 1210 ± 94 μg m-3 and 561 ± 45 μg m-3 in Vientiane and Bolikhamxay, respectively) were measured within the dwellings. Correlations, ANOVA analysis (univariate and multivariate), and linear regression results suggest a substantial contribution from cookingandsmoking.The PM10 concentrations were significantly higher in houses without a chimney compared to houses in which cooking occurred on a stove with a chimney. However, no significant differences in pollutantconcentrations were observed as a function of cooking location. Furthermore, PM10 and NO2 concentrations were higher in houses in which smoking occurred, suggestive of a relationship between increased indoor concentrations and smoking (0.05 < p < 0.10). Resuspension of dust from soil floors was another significant source of PM10 inside the house (634 μg m-3, p < 0.05).
Resumo:
House dust is a heterogeneous matrix, which contains a number of biological materials and particulate matter gathered from several sources. It is the accumulation of a number of semi-volatile and non-volatile contaminants. The contaminants are trapped and preserved. Therefore, house dust can be viewed as an archive of both the indoor and outdoor air pollution. There is evidence to show that on average, people tend to stay indoors most of the time and this increases exposure to house dust. The aims of this investigation were to: " assess the levels of Polycyclic Aromatic Hydrocarbons (PAHs), elements and pesticides in the indoor environment of the Brisbane area; " identify and characterise the possible sources of elemental constituents (inorganic elements), PAHs and pesticides by means of Positive Matrix Factorisation (PMF); and " establish the correlations between the levels of indoor air pollutants (PAHs, elements and pesticides) with the external and internal characteristics or attributes of the buildings and indoor activities by means of multivariate data analysis techniques. The dust samples were collected during the period of 2005-2007 from homes located in different suburbs of Brisbane, Ipswich and Toowoomba, in South East Queensland, Australia. A vacuum cleaner fitted with a paper bag was used as a sampler for collecting the house dust. A survey questionnaire was filled by the house residents which contained information about the indoor and outdoor characteristics of their residences. House dust samples were analysed for three different pollutants: Pesticides, Elements and PAHs. The analyses were carried-out for samples of particle size less than 250 µm. The chemical analyses for both pesticides and PAHs were performed using a Gas Chromatography Mass Spectrometry (GC-MS), while elemental analysis was carried-out by using Inductively-Coupled Plasma-Mass Spectroscopy (ICP-MS). The data was subjected to multivariate data analysis techniques such as multi-criteria decision-making procedures, Preference Ranking Organisation Method for Enrichment Evaluations (PROMETHEE), coupled with Geometrical Analysis for Interactive Aid (GAIA) in order to rank the samples and to examine data display. This study showed that compared to the results from previous works, which were carried-out in Australia and overseas, the concentrations of pollutants in house dusts in Brisbane and the surrounding areas were relatively very high. The results of this work also showed significant correlations between some of the physical parameters (types of building material, floor level, distance from industrial areas and major road, and smoking) and the concentrations of pollutants. Types of building materials and the age of houses were found to be two of the primary factors that affect the concentrations of pesticides and elements in house dust. The concentrations of these two types of pollutant appear to be higher in old houses (timber houses) than in the brick ones. In contrast, the concentrations of PAHs were noticed to be higher in brick houses than in the timber ones. Other factors such as floor level, and distance from the main street and industrial area, also affected the concentrations of pollutants in the house dust samples. To apportion the sources and to understand mechanisms of pollutants, Positive Matrix Factorisation (PMF) receptor model was applied. The results showed that there were significant correlations between the degree of concentration of contaminants in house dust and the physical characteristics of houses, such as the age and the type of the house, the distance from the main road and industrial areas, and smoking. Sources of pollutants were identified. For PAHs, the sources were cooking activities, vehicle emissions, smoking, oil fumes, natural gas combustion and traces of diesel exhaust emissions; for pesticides the sources were application of pesticides for controlling termites in buildings and fences, treating indoor furniture and in gardens for controlling pests attacking horticultural and ornamental plants; for elements the sources were soil, cooking, smoking, paints, pesticides, combustion of motor fuels, residual fuel oil, motor vehicle emissions, wearing down of brake linings and industrial activities.
Resumo:
Just as telecommunications has played a key role in the global economy,1 high-speed broadband will have a significant role to play in the future of the digital economy. In particular high-speed broadband will have a role to play in the delivery of applications and services necessary for acquiring, and maintaining into the future Australia and Australians’ appropriate education level; community; health services, information provision and support; government services and engagement and participation by the public in the political process.
Resumo:
Poem
Resumo:
The Old Government House, a former residence of the Queen’s representatives in Brisbane, Australia, symbolises British cultural heritage of Colonial Queensland. Located on the campus of the Queensland University of Technology, it is one of the oldest surviving examples of a stately residence in Queensland. Built in 1860s, the Old Government House was originally intended as a temporary residence for the first governor of the newly independent colony of Queensland. However, it remained the vice-regal residence until 1909, serving eleven succeeding governors. Nearly seven decades later, it became the first building in Queensland to be protected under heritage legislation. Thus its importance, as an excellent exemplar that demonstrates the significance of cultural heritage, was established. The Old Government House has survived 150 years of restoration work, refurbishments, and additions. Through these years, it has served the people of Queensland in a multitude of roles. This paper aims to investigate the survival of heritage listed buildings through their adaptive re-use. Its focus will be on the adaptive reuse of the Old Government House through its refurbishments and additions over a period of 150 years. Through a qualitative research process this paper will endeavour to establish the significance of restoration work on the Old Government house; the new opportunities that has opened up as a result of the restoration work; the continued maintenance and management of the building through adaptive re-use; the economic benefits of restoration work; and its contribution to the on-going interest in the preservation of the Tangible Cultural Heritage.
Resumo:
22 mins documentary
Resumo:
Poem