979 resultados para HELICAL CT


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Malignancies of the biliary and pancreatic systems are associated with a poor prognosis. However, ampullary cancer carries a better prognosis and is often diagnosed when curative treatment is still possible. Accurate staging is important for the determination of the most appropriate treatment option. Objectives: (1) To determine the test performance characteristics of EUS and CT in loco-regional staging of ampullary neoplasms, and (2) to determine the impact of CT scan results on the test performance characteristics of EUS. Design and Setting: Prospective single-arm intervention study performed in 2 academic hospitals. Results and Main Outcome Measurements: Thirty-seven patients were screened and 33 staged with EUS and CT A total of 27 patients (13 men; mean age, 69.5 years; mean serum bilirubin level, 12.6 mg/dL) with locally advanced disease completed the protocol with EUS and CT and underwent surgical resection. Tumor classifications were as follows: 2 patients (7.4%), T1 tumors; 13 patients (48.1%), T2 tumors; and 12 patients (44.4%), T3 tumors, as per surgical pathology. Seventeen tumors (62.9%) were classified as NO and 10 (37.1%) as NI. The difference in proportion of correct tumor (74.1% vs 51.8%; P =.15, 95% CI, -0.06-0-50) and lymph node (81.4% vs; 55.5%; P =.07, 95% Cl, -0.01-0.53) staging by EUS and CT, respectively, was not statistically significantly different. However, the strength of tumor (kappa 0.51 vs 0.11) and nodal (kappa 0.59 vs 0.05) agreement with pathology was statistically significantly higher for EUS than for CT (P <.05). EUS was more sensitive and specific than CT for tumor and nodal staging, and the association of CT to EUS data did not improve the final test accuracy Limitation: Low number of T1 tumors. Conclusions: EUS is in accurate diagnostic test and exhibits a high level of agreement with surgical pathology. CT findings do not improve the test performance characteristics of EUS. Therefore, the evaluation for metastatic disease should not be compromised by CT protocols that aim to perform tumor and nodal staging. Further studies to determine the role of specialized CT protocols in patients with ampullary malignancies are needed. (Gastrointest Endosc 2009;70:290-6.)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background The development of products and services for health care systems is one of the most important phenomena to have occurred in the field of health care over the last 50 years. It generates significant commercial, medical and social results. Although much has been done to understand how health technologies are adopted and regulated in developed countries, little attention has been paid to the situation in low- and middle-income countries (LMICs). Here we examine the institutional environment in which decisions are made regarding the adoption of expensive medical devices into the Brazilian health care system. Methods We used a case study strategy to address our research question. The empirical work relied on in-depth interviews (N = 16) with representatives of a wide range of actors and stakeholders that participate in the process of diffusion of CT (computerized tomography) scanners in Brazil, including manufacturers, health care organizations, medical specialty societies, health insurance companies, regulatory agencies and the Ministry of Health. Results The adoption of CT scanners is not determined by health policy makers or third-party payers of public and private sectors. Instead, decisions are primarily made by administrators of individual hospitals and clinics, strongly influenced by both physicians and sales representatives of the medical industry who act as change agents. Because this process is not properly regulated by public authorities, health care organizations are free to decide whether, when and how they will adopt a particular technology. Conclusions Our study identifies problems in how health care systems in LMICs adopt new, expensive medical technologies, and suggests that a set of innovative approaches and policy instruments are needed in order to balance the institutional and professional desire to practise a modern and expensive medicine in a context of health inequalities and basic health needs.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objectives: The aim of this study was to determine the precision of the measurements of 2 craniometric anatomic points-glabella and anterior nasal spine-in order to verify their possibility as potential locations for placing implants aimed at nasal prostheses retention. Methods: Twenty-six dry human skulls were scanned in a high-resolution spiral tomography with 1-mm axial slice thickness and 1-mm interval reconstruction using a bone tissue filter. Images obtained were stored and transferred to an independent workstation containing e-film imaging software. The measurements (in the glabella and anterior nasal fossa) were made independently by 2 observers twice for each measurement. Data were submitted to statistical analysis (parametric t test). Results: The results demonstrated no statistically significant difference between interobserver and intraobserver measurements (P > .05). The standard error was found to be between 0.49 mm and 0.84 mrn for measurements in bone protocol, indicating a high /eve/ of precision. Conclusions: The measurements obtained in anterior nasal spine and glabella were considered precise and reproducible. Mean values of such measurements pointed to the possibility of implant placement in these regions, particularly in the anterior nasal spine.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Resistively loaded helical antennas, used in the normal mode and horizontally polarised, are modelled using the moment method above typical lossy ground. The distributed resistive loading was adjusted to maintain a two octave bandwidth. The centre frequency of 1 m dipoles was reduced from 250 MHz for the straight resistive wire to 50 MHz for a helix of pitch 2.5 cm and diameter 5 cm. The reduction in efficiency required to maintain the bandwidth for this helix was 12 dB. This agrees reasonably with the theory for small antennas in free space. The results were also verified by comparing measurements performed on a monopole resistively loaded helical antenna in a watertank with the numerical model used elsewhere.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A conserved helical peptide vaccine candidate from the M protein of group A streptococci, p145, has been described. Minimal epitopes within p145 have been defined and an epitope recognized by protective antibodies, but not by autoreactive T cells, has been identified. When administered to mice, p145 has low immunogenicity. Many boosts of peptide are required to achieve a high antibody titre (> 12 800). To attempt to overcome this low immunogenicity, lipid-core peptide technology was employed. Lipid-core peptides (LCP) consist of an oligomeric polylysine core, with multiple copies of the peptide of choice, conjugated to a series of lipoamino acids, which acts as an anchor for the antigen. Seven different LCP constructs based on the p145 peptide sequence were synthesized (LCP1-->LCP7) and the immunogenicity of the compounds examined. The most immunogenic constructs contained the longest alkyl side-chains. The number of lipoamino acids in the constructs affected the immunogenicity and spacing between the alkyl side-chains increased immunogenicity. An increase in immunogenicity (enzyme-linked immunosorbent assay (ELISA) titres) of up to 100-fold was demonstrated using this technology and some constructs without adjuvant were more immunogenic than p145 administered with complete Freund's adjuvant (CFA). The fine specificity of the induced antibody response differed for the different constructs but one construct, LCP4, induced antibodies of identical fine specificity to those found in endemic human serum. Opsonic activity of LCP4 antisera was more than double that of p145 antisera. These data show the potential for LCP technology to both enhance immunogenicity of complex peptides and to focus the immune response towards or away from critical epitopes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background and aims: Hip fracture is a devastating event in terms of outcome in the elderly, and the best predictor of hip fracture risk is hip bone density, usually measured by dual X-ray absorptiometry (DXA). However, bone density can also be ascertained from computerized tomography (CT) scans, and mid-thigh scans are frequently employed to assess the muscle and fat composition of the lower limb. Therefore, we examined if it was possible to predict hip bone density using mid-femoral bone density. Methods: Subjects were 803 ambulatory white and black women and men, aged 70-79 years, participating in the Health, Aging and Body Composition (Health ABC) Study. Bone mineral content (BMC, g) and volumetric bone mineral density (vBMD, mg/cm(3)) of the mid-femur were obtained by CT, whereas BMC and areal bone mineral density (aBMD, g/cm(2)) of the hip (femoral neck and trochanter) were derived from DXA. Results: In regression analyses stratified by race and sex, the coefficient of determination was low with mid-femoral BMC, explaining 6-27% of the variance in hip BMC, with a standard error of estimate (SEE) ranging from 16 to 22% of the mean. For mid-femur vBMD, the variance explained in hip aBMD was 2-17% with a SEE ranging from 15 to 18%. Adjusting aBMD to approximate volumetric density did not improve the relationships. In addition, the utility of fracture prediction was examined. Forty-eight subjects had one or more fractures (various sites) during a mean follow-up of 4.07 years. In logistic regression analysis, there was no association between mid-femoral vBMD and fracture (all fractures), whereas a 1 SD increase in hip BMD was associated with reduced odds for fracture of similar to60%. Conclusions: These results do not support the use of CT-derived mid-femoral vBMD or BMC to predict DXA-measured hip bone mineral status, irrespective of race or sex in older adults. Further, in contrast to femoral neck and trochanter BMD, mid-femur vBMD was not able to predict fracture (all fractures). (C) 2003, Editrice Kurtis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

One of the current frontiers in the clinical management of Pectus Excavatum (PE) patients is the prediction of the surgical outcome prior to the intervention. This can be done through computerized simulation of the Nuss procedure, which requires an anatomically correct representation of the costal cartilage. To this end, we take advantage of the costal cartilage tubular structure to detect it through multi-scale vesselness filtering. This information is then used in an interactive 2D initialization procedure which uses anatomical maximum intensity projections of 3D vesselness feature images to efficiently initialize the 3D segmentation process. We identify the cartilage tissue centerlines in these projected 2D images using a livewire approach. We finally refine the 3D cartilage surface through region-based sparse field level-sets. We have tested the proposed algorithm in 6 noncontrast CT datasets from PE patients. A good segmentation performance was found against reference manual contouring, with an average Dice coefficient of 0.75±0.04 and an average mean surface distance of 1.69±0.30mm. The proposed method requires roughly 1 minute for the interactive initialization step, which can positively contribute to an extended use of this tool in clinical practice, since current manual delineation of the costal cartilage can take up to an hour.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Os linfomas são tumores estabelecidos a nível do sistema linfático. Devido à sua heterogeneidade classificam-se como Linfoma Hodgkin (LH) e Linfoma não Hodgkin (LNH), apresentando diferente prognóstico e seguimento quimioterapêutico. Actualmente, a Photon Emission Tomography/Computed Tomography (PET/CT, do acrónimo inglês) é considerada “imagem” de excelência no estudo desta patologia. Neste contexto, é objectivo deste artigo verificar a utilidade da técnica PET/CT e correlacionar o valor de Standard Uptake Value (SUV), obtido pela PET, com o estadio histológico do linfoma e com a resposta ao tratamento quimioterapêutico. Metodologia - Analisaram-se retrospectivamente 356 estudos respeitantes a 231 pacientes, aos quais se realizou uma PET/CT para estadiamento, estudo de massa ou avaliação da resposta ao tratamento. Após a administração de uma actividade média de 18F-FDG de 288,6 MBq, foram adquiridas imagens numa PET/CT GE Discovery ST. Os resultados obtidos foram comparados com os dados clínicos dos pacientes. Resultados - Foram encontradas diferenças significativas entre a idade Vs tipo de linfoma. Não foram encontradas diferenças significativas entre: valor de SUVmáx ganglionar, lesões extra-ganglionares e seu valor de SUV relativamente ao tipo de linfoma. Comprovou-se a influência da PET/CT na alteração do estadio do linfoma e atitude terapêutica. Em última análise, obtiveram-se respectivamente os seguintes valores de sensibilidade, especificidade e exactidão: 98%, 79% e 88%. Conclusões - Os resultados obtidos permitem verificar a importância da imagem PET/CT no estadiamento, monitorização e alteração da atitude terapêutica dos LH e LNH.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introdução – O cancro de pulmão/traqueia e brônquios é a principal causa de morte por neoplasia na União Europeia. A técnica de duas aquisições de imagem em tempos diferentes no Positron Emission Tomography/Computed Tomography (PET/CT) tem sido referenciada em alguns artigos como uma mais-valia no diagnóstico do cancro do pulmão. O objectivo deste estudo consiste em avaliar a eficiência diagnóstica do PET/CT com a aquisição das duas imagens em tempos diferentes na caracterização do nódulo solitário pulmonar (NSP), tendo em conta a histologia e o tamanho do nódulo. Metodologia – Foram analisados 115 NSP, num total de 110 pacientes, dos quais 65 nódulos eram malignos. Adquiriram-se duas imagens, a primeira a um tempo médio de 52 minutos e a segunda a um tempo médio de 125 minutos após administração do 18F-2-fluoro-2-deoxi-D-glucose (18F-FDG). Para a análise das imagens obteve-se o standard uptake value máximo (SUVmax) e a percentagem de variação dos SUVmax (%variação). Resultados – A %variação apresenta valores de eficiência diagnóstica superiores à análise dos SUVmax em separado. Existem também diferenças significativas na histologia e no SUVmax, registando-se um aumento do SUVmax2 comparativamente ao SUVmax1 nas patologias malignas. Conclusão – A técnica da aquisição de duas imagens em tempos diferentes mostrou ser mais eficaz na caracterização do NSP do que a análise de apenas uma imagem.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Mestrado em Radiações Aplicadas às Tecnologias da Saúde. Área de especialização: Protecção Contra Radiações

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Mestrado em Medicina Nuclear - Área de especialização: Tomografia por Emissão de Positrões.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Monte Carlo (MC) dose calculation algorithms have been widely used to verify the accuracy of intensity-modulated radiotherapy (IMRT) dose distributions computed by conventional algorithms due to the ability to precisely account for the effects of tissue inhomogeneities and multileaf collimator characteristics. Both algorithms present, however, a particular difference in terms of dose calculation and report. Whereas dose from conventional methods is traditionally computed and reported as the water-equivalent dose (Dw), MC dose algorithms calculate and report dose to medium (Dm). In order to compare consistently both methods, the conversion of MC Dm into Dw is therefore necessary. This study aims to assess the effect of applying the conversion of MC-based Dm distributions to Dw for prostate IMRT plans generated for 6 MV photon beams. MC phantoms were created from the patient CT images using three different ramps to convert CT numbers into material and mass density: a conventional four material ramp (CTCREATE) and two simplified CT conversion ramps: (1) air and water with variable densities and (2) air and water with unit density. MC simulations were performed using the BEAMnrc code for the treatment head simulation and the DOSXYZnrc code for the patient dose calculation. The conversion of Dm to Dw by scaling with the stopping power ratios of water to medium was also performed in a post-MC calculation process. The comparison of MC dose distributions calculated in conventional and simplified (water with variable densities) phantoms showed that the effect of material composition on dose-volume histograms (DVH) was less than 1% for soft tissue and about 2.5% near and inside bone structures. The effect of material density on DVH was less than 1% for all tissues through the comparison of MC distributions performed in the two simplified phantoms considering water. Additionally, MC dose distributions were compared with the predictions from an Eclipse treatment planning system (TPS), which employed a pencil beam convolution (PBC) algorithm with Modified Batho Power Law heterogeneity correction. Eclipse PBC and MC calculations (conventional and simplified phantoms) agreed well (<1%) for soft tissues. For femoral heads, differences up to 3% were observed between the DVH for Eclipse PBC and MC calculated in conventional phantoms. The use of the CT conversion ramp of water with variable densities for MC simulations showed no dose discrepancies (0.5%) with the PBC algorithm. Moreover, converting Dm to Dw using mass stopping power ratios resulted in a significant shift (up to 6%) in the DVH for the femoral heads compared to the Eclipse PBC one. Our results show that, for prostate IMRT plans delivered with 6 MV photon beams, no conversion of MC dose from medium to water using stopping power ratio is needed. In contrast, MC dose calculations using water with variable density may be a simple way to solve the problem found using the dose conversion method based on the stopping power ratio.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Helically twisted fibers can be produced by electrospinning liquid-crystalline cellulose solutions. Fiber topographies are studied by atomic force microscopy, scanning electron microscopy (see figure) and polarized optical microscopy. The fibers have a nearly universal pitch-to-diameter ratio and comprise both right- and left-handed helices.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Mestrado em Medicina Nuclear - Ramo de especialização: Tomografia por Emissão de Positrões

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Radiotherapy is one of the therapeutics selected for localized prostate cancer, in cases where the tumour is confined to the prostate, penetrates the prostatic capsule or has reached the seminal vesicles (T1 to T3 stages). The radiation therapy can be administered through various modalities, being historically used the 3D conformal radiotherapy (3DCRT). Other modality of radiation administration is the intensity modulated radiotherapy (IMRT), that allows an increase of the total dose through modulation of the treatment beams, enabling a reduction in toxicity. One way to administer IMRT is through helical tomotherapy (TH). With this study we intent to analyze the advantages of helical tomotherapy when compared with 3DCRT, by evaluating the doses in the organs at risk (OAR) and planning target volumes (PTV).