977 resultados para HCV polymerase
Resumo:
Due to their spatial structure virus-like particles (VLPs) generally induce effective immune responses. VLPs derived from the small envelope protein (HBsAg-S) of hepatitis B virus (HBV) comprise the HBV vaccine. Modified HBsAs-S VLPs, carrying the immunodominant hypervariable region (HVR1) of the hepatitis C virus (HCV) envelope protein E2 within the exposed 'a'-determinant region (HBsAg/HVR1-VLPs), elicited HVR1-specific antibodies in mice. A high percentage of the human population is positive for anti-HBsAg antibodies (anti-HBs), either through vaccination or natural infection. We, therefore, determined if pre-existing anti-HBs could influence immunisation with modified VLPs. Mice were immunised with a commercial HBV vaccine, monitored to ensure an anti-HBs response, then immunised with HBsAg/HVR1-VLPs. The resulting anti-HVR1 antibody titre was similar in mice with or without pre-existing anti-HBs. This suggests that HBsAg/HVR1-VLPs induce a primary immune response to HVR1 in anti-HBs positive mice and, hence, they may be used successfully in individuals already immunised with the HBV vaccine. (C) 2003 Elsevier Science Ltd. All rights reserved.
Resumo:
Objective To develop and validate specific, sensitive and rapid diagnostic tests using RT-PCR for the detection of Ross River virus (RRV), Kunjin virus (KV) and Murray Valley encephalitis virus (MVEV) infections in horses. Methods Primer sets based on nucleotide sequence encoding the envelope glycoprotein E2 of RRV and on the nonstructural protein 5 (NS5) of KV and MVEV were designed and used in single round PCRs to test for the respective viruses in infected cell cultures and, in the case of RRV, in samples of horse blood and synovial fluid. Results The primer pairs designed for each of the three viruses amplified a product of expected size from prototype viruses that were grown in cell culture. The identity of each of the products was confirmed by nucleotide sequencing indicating that in the context used the RT-PCRs were specific. RRV was detected in serums from 8 horses for which there were clinical signs consistent with RRV infection such that an acute-phase serum sample was taken and submitted for RRV serology testing. The RRV RT-PCR was analytically sensitive in that it was estimated to detect as little as 50 TCID50 of RRV per mL of serum and was specific in that the primer pairs did not amplify other products from the 8 serum samples. The RRV primers also detected virus in three independent mosquito pools known to contain RRV by virus isolation in cell culture. Samples from horses suspected to be infected with KV and MVEV were not available. Conclusion Despite much anecdotal and serological evidence for infection of horses with RRV actual infection and associated clinical disease are infrequently confirmed. The availability of a specific and analytically sensitive RT-PCR for the detection of RRV provides additional opportunities to confirm the presence of this virus in clinical samples. The RTPCR primers for the diagnosis of KV and MVEV infections were shown to be specific for cell culture grown viruses but the further validation of these tests requires the availability of appropriate clinical samples from infected horses.
Resumo:
Objectivo do estudo - Avaliar o desempenho de dois testes rápidos, um para detecção do antigénio de superfície do vírus da Hepatite B (AgHBs) e outro para detecção de anticorpos contra o vírus da Hepatite C (anti-HCV).
Resumo:
OBJECTIVE: It is an accepted fact that confinement conditions increase the risk of some infections related to sexual and/or injecting drugs practices. Mathematical techniques were applied to estimate time-dependent incidence densities of HIV infection among inmates. METHODS: A total of 631 prisoners from a Brazilian prison with 4,900 inmates at that time were interviewed and their blood drawn. Risky behavior for HIV infection was analyzed, and serological tests for HIV, hepatitis C and syphilis were performed, intended as surrogates for parenteral and sexual HIV transmission, respectively. Mathematical techniques were used to estimate the incidence density ratio, as related to the time of imprisonment. RESULTS: Prevalence were: HIV -- 16%; HCV -- 34%; and syphilis -- 18%. The main risk behaviors related to HIV infection were HCV prevalence (OR=10.49) and the acknowledged use of injecting drugs (OR=3.36). Incidence density ratio derivation showed that the risk of acquiring HIV infection increases with the time of imprisonment, peaking around three years after incarceration. CONCLUSIONS: The correlation between HIV and HCV seroprevalence and the results of the mathematical analysis suggest that HIV transmission in this population is predominantly due to parenteral exposure by injecting drug, and that it increases with time of imprisonment.
Resumo:
Estudo transversal para verificar a prevalência de anticorpos contra hepatite em pacientes dialisados e fatores associados. Foi realizada revisão de prontuários de todos os pacientes dialisados (n=1.261) de Porto Alegre, RS, de agosto a dezembro de 2003. Os testes estatísticos aplicados foram o qui-quadrado e o teste de tendência linear. A medida de efeito foi a razão de prevalências. A análise de regressão logística múltipla foi realizada por regressão de Cox. A prevalência de anticorpos contra hepatite foi 29,1%, com prevalência maior entre pacientes atendidos em hemodiálise onde não havia separação dos soropositivos e existia reutilização do dialisador. Essa associação permaneceu mesmo após controle para fatores de confusão. Pacientes que receberam transfusão sangüínea tiveram acréscimo linear na prevalência de anticorpos. O tempo de diálise mostrou associação do tipo dose-resposta com os anticorpos contra hepatite.
Resumo:
OBJETIVO: Estimar a prevalência do vírus da hepatite C (HCV) e fatores de risco associados com a co-infecção em pessoas soropositivas para HIV. MÉTODOS: Estudo do tipo transversal, descritivo e analítico, com 343 portadores do HIV atendidos em um hospital universitário de Recife (PE), no período de março a dezembro de 2003. Os pacientes foram submetidos a um questionário padronizado sobre os fatores de risco. Nas amostras de soro foram pesquisados o anti-HCV pelo ELISA, o HCV-RNA por meio da RT-PCR e a identificação dos genótipos foi realizada no equipamento ABI377 (PE Biosystems®). As análises estatísticas utilizadas foram a univariada, a multivariada e a regressão logística múltipla. RESULTADOS: A prevalência encontrada para o HCV foi de 4,1% (14/343) pelo ELISA e de 3,2 % (11/343) quando utilizada a RT-PCR. Os genótipos mais freqüentes foram 1b (45%), 3 (33%) e 1a (22%). A faixa etária com maior proporção de co-infectados foi a de 30 a 39 anos, com predomínio do sexo masculino (64,3%). Após regressão logística múltipla, apenas a variável transfusão sangüínea permaneceu como fator de risco para o HCV (OR=4,28; IC 95%: 1,44;12,73). CONCLUSÕES: A prevalência da co-infecção HIV/HCV foi baixa, a transfusão sangüínea foi um fator de risco e o genótipo 1b do HCV foi o mais freqüente.
Resumo:
The detection of HBV-DNA in serum by molecular hybridization is the most sensitive and specific marker of replication and infectivity of hepatitis B virus and currently is proposed as a routine diagnostic technique in the follow-up of HBV - related diseases. Comparing different techniques already described, we found that direct spotting of serum samples on nitrocellulose membranes under vacuum filtration, followed by denaturing and neutralizing washes is more practical, simple, sensible and reproducible. DNA polymerase assay using phosphonoformic acid as specific viral inhibitor has shown 86.8% of concordance with HBV-DNA detection, and so, it is an useful alternative in the follow-up of hepatitis B chronic patients. We found 19.2% HBeAg positive samples with no other markers of viral replication and no anti-HBe positive sample had detectable HBV-DNA. Discordance between the 2 systems have been extensively described, and we confirm this for the first time in our country. Molecular biological techniques are essential to determine the replication status of chronic hepatitis B patients.
Resumo:
We study a mathematical model for the human immunodeficiency virus (HIV) and hepatites C virus (HCV) coinfection. The model predicts four distinct equilibria: the disease free, the HIV endemic, the HCV endemic, and the full endemic equilibria. The local and global stability of the disease free equilibrium was calculated for the full model and the HIV and HCV submodels. We present numerical simulations of the full model where the distinct equilibria can be observed. We show simulations of the qualitative changes of the dynamical behavior of the full model for variation of relevant parameters. From the results of the model, we infer possible measures that could be implemented in order to reduce the number of infected individuals.
Resumo:
Em 29833 doadores pesquisados encontramos prevalência de 1,52% para o HBsAg e de 11% para o anti-HBc. A co-positividade anti-HBc/anti-HBs em 2783 doadores HBsAg negativos/anti-HBc positivos foi de 81,9%. A prevalência para o HBsAg é baixa nos doadores de Campinas, enquanto o anti-HBc apresenta-se com prevalência elevada quando comparado a outros países. A pesquisa do anti-HCV, em doadores de sangue de Campinas, mostrou prevalência de 2,6% para este marcador, que é bem maior que as observadas nos EUA e Europa. Cerca de 36% dos doadores anti-HCV positivos são anti-HBc reagentes, permitindo inferir, que estas duas viroses acometem simultânea ou sequencialmente os doadores de sangue brasileiros.
Resumo:
Pesquisamos os anticorpos anti-HBc e anti-HCV em amostras de soros provenientes de 799 candidatos a doadores, que tiveram suas unidades de sangue ou derivados transfundidas a 111 receptores. O anti-HBc e o anti-HCV foram reagentes, em respectivamente 9 e 2,1% dos doadores testados. Observamos que entre os 111 receptores, 44 haviam recebido pelo menos uma unidade anti-HBc positiva e 67 haviam sido transfundidos somente com unidades anti-HBc negativas. Houve um risco 4,5 vezes maior de aquisição de hepatite por vírus C pelos receptores que receberam pelo menos uma unidade anti-HBc positiva Se a pesquisa do anti-HBc fosse realizada na triagem sorológica dos doadores de sangue, cerca de 56% dos casos de HVC nos receptores saiam evitados. A população de receptores que recebeu pelo menos uma unidade anti-HCV reagente, apresentou um risco 29 vezes maior de adquirir esta hepatite, quando comparada aos receptores transfundidos com todas as unidades anti-HCV negativas. A realização do teste para a pesquisa do anti-HCV na triagem dos doadores de sangue, preveniria 79% dos casos de HVC pós-transfusionais. Os candidatos a doadores brasileiros parecem ser acometidos simultânea ou sequencialmente, pelos vírus B e C das hepatites, pois, 44,4% dos doadores anti-HCV positivos, também foram anti-HBc positivos. A realização dos testes para as pesquisas dos anticorpos anti-HBc e anti-HCV, nas triagens hemoterápicas, está indicada para prevenir a transmissão de hepatites pós-transfusionais, em nosso meio.
Resumo:
Two groups of patients undergoing hemodialysis (HD) maintenance were evaluated for their antibody response to non-structural c100/3 protein and structural core protein of hepatitis C virus (HCV). Forty-six patients (Group 1) never presented liver abnormalities during HD treatment, while 52 patients (Group 2) had either current or prior liver enzyme elevations. Prevalence rates of 32.6% and 41.3% were found for anti-c100/3 and anti-HCV core antibodies, respectively, in patients with silent infections (Group 1). The rate of anti-c100/3 in patients of Group 2 was 71.15% and reached 86.5% for anti-HCV core antibodies. The recognition of anti-c100/3 and anti-core antibodies was significantly higher in Group 2 than in Group 1. A line immunoassay composed of structural and non-structural peptides was used as a confirmation assay. HBV infection, measured by the presence of anti-HBc antibodies, was observed in 39.8% of the patients. Six were HBsAg chronic carriers and 13 had naturally acquired anti-HBs antibodies. The duration of HD treatment was correlated with anti-HCV positivity. A high prevalence of 96.7% (Group 2) was found in patients who underwent more than 5 years of treatment. Our results suggest that anti-HCV core ELISA is more accurate for detecting HCV infection than anti-c100/3. Although the risk associated with the duration of HD treatment and blood transfusion was high, additional factors such as a significant non-transfusional spread of HCV seems to play a role as well. The identification of infective patients by more sensitive methods for HCV genome detection should help to control the transmission of HCV in the unit under study.
Resumo:
Detection of HBV-DNA by PCR was compared with other serological markers (HBsAg, HBeAg and anti-HBe) in a series of49 Chronic Hepatitis B patients, including 12 with a spontaneous clearance of HBsAg. None of these HBsAg negative cases were PCR positive, but 33/37 (89.2%) HBsAg positive cases were PCR positive (p < 0.0001). Among HBsAg positive samples, nine cases were HBeAg positive and anti-HBe negative, all of them PCR positive. Other 3 patients were HBeAg and anti-HBe positive and these cases were also found PCR positive. A third group included 21 patients anti-HBe positive and HBeAg negative: 19 of them were PCR positive and 2 were PCR negative. The last 4 cases were HBeAg and anti-HBe negative, two of them were PCR positive. The detection of anti-HBe viremic cases in the present series suggest that preC variants could occur in our country. In conclusion, the integrated phase o f chronic hepatitis B seems to be less frequent than it was assumed, when only HBeAg or dot blot hybridization techniques were used. The new term "low replication phase" might favorably replace the former "integrated phase".
Resumo:
Data concerning HCV infection in Central Brazil are rare. Upon testing 2,350 voluntary blood donors from this region, we found anti-HCV prevalence rates of 2.2% by a second generation ELISA and 1.4% after confirmation by a line immunoassay. Antibodies against core, NS4, and NS5 antigens of HCV were detected in 81.8%, 72.7%, and 57.5%, respectively, of the positive samples in the line immunoassay. HCV viremia was present in 76.6% of the anti-HCV-positive blood donors. A relation was observed between PCR positivity and serum reactivity in recognizing different HCV antigens in the line immunoassay. The majority of the positive donors had history of previous parenteral exposure. While the combination of ALT>50 IU/l and anti-HBc positivity do not appear to be good surrogate markers for HCV infection, the use of both ALT anti-HCV tests is indicated in the screening of Brazilian blood donors.
Resumo:
We show here a simplified RT-PCR for identification of dengue virus types 1 and 2. Five dengue virus strains, isolated from Brazilian patients, and yellow fever vaccine 17DD as a negative control, were used in this study. C6/36 cells were infected and supernatants were collected after 7 days. The RT-PCR, done in a single reaction vessel, was carried out following a 1/10 dilution of virus in distilled water or in a detergent mixture containing Nonidet P40. The 50 µl assay reaction mixture included 50 pmol of specific primers amplifying a 482 base pair sequence for dengue type 1 and 210 base pair sequence for dengue type 2. In other assays, we used dengue virus consensus primers having maximum sequence similarity to the four serotypes, amplifying a 511 base pair sequence. The reaction mixture also contained 0.1 mM of the four deoxynucleoside triphosphates, 7.5 U of reverse transcriptase, 1U of thermostable Taq DNA polymerase. The mixture was incubated for 5 minutes at 37ºC for reverse transcription followed by 30 cycles of two-step PCR amplification (92ºC for 60 seconds, 53ºC for 60 seconds) with slow temperature increment. The PCR products were subjected to 1.7% agarose gel electrophoresis and visualized by UV light after staining with ethidium bromide solution. Low virus titer around 10 3, 6 TCID50/ml was detected by RT-PCR for dengue type 1. Specific DNA amplification was observed with all the Brazilian dengue strains by using dengue virus consensus primers. As compared to other RT-PCRs, this assay is less laborious, done in a shorter time, and has reduced risk of contamination