999 resultados para Gated blood pool SPECT


Relevância:

40.00% 40.00%

Publicador:

Resumo:

FUNDAMENTO: Alguns pacientes apresentam fração de ejeção do ventrículo esquerdo (FEVE) superestimada na cintilografia miocárdica com sincronização eletrocardiográfica (gated SPECT). OBJETIVO: Estabelecer a relação entre fatores biológicos e FEVE superestimada. MÉTODOS: Selecionamos 3.838 pacientes que realizaram gated SPECT entre 20/5/2000 e 16/9/2005, com imagens normais de perfusão e FEVE >50%. Analisamos as variáveis: sexo (29,4% feminino e 70,6% masculino), idade (de 20 a 94 anos - média: 56 anos), peso (de 33,5 a 150 kg - média: 79,6 kg), altura (de 138 a 220 cm - média: 171 cm) e IMC (de 13,9 a 54 - média: 27,2). Em um subgrupo de 1.002 pacientes que realizaram ecocardiograma, incluímos as variáveis diâmetros diastólico (de 36 a 68 mm - média 47,5 mm) e sistólico (de 22 a 41 mm - média 29,8 mm). Dividimos os pacientes em dois grupos: FEVE normal (<80%) e superestimada (>80%). A Razão de Chances (RC) para apresentar FEVE superestimada foi calculada para cada variável por regressão logística. RESULTADOS: Encontramos as seguintes Razões de Chances (p < 0,005): sexo feminino RC = 3,585 (IC95%: 2,745 a 4,683), idade em anos RC = 1,020 (IC95%: 1,011 a 1,029) e altura em cm RC = 0,893 (IC95%: 0,829 a 0,962). O peso e o IMC não se associaram a FEVE significativamente (p>0,2). No subgrupo de 1.002 pacientes, encontramos influência estatisticamente significativa na obtenção da FEVE superestimada para as variáveis diâmetro sistólico, sexo e altura. CONCLUSÃO: Apesar de o diâmetro sistólico influenciar na obtenção da FEVE superestimada, as variáveis sexo e altura apresentam influência independente na superestimação da FEVE pelo gated SPECT.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

FUNDAMENTO: A avaliação da função ventricular esquerda pode ser limitada pela movimentação anômala do septo interventricular, freqüentemente encontrada após cirurgia de revascularização miocárdica (CRM). A validação do Gated SPECT como ferramenta para avaliação da função ventricular nesse grupo de pacientes é escassa. OBJETIVO: Investigamos a concordância e a correlação entre a fração de ejeção do ventrículo esquerdo (FEVE), o volume diastólico final (VDF) e o volume sistólico final (VDF), obtidos pela cintilografia de perfusão miocárdica tomográfica sincronizada pelo eletrocardiograma (Gated SPECT), com os mesmos parâmetros medidos pela ressonância magnética cardíaca em 20 pacientes submetidos à revascularização miocárdica. MÉTODOS: A correlação foi medida pelo coeficiente de correlação de Spearman (ρ), enquanto a concordância foi avaliada por meio da análise de Bland e Altman. RESULTADOS: Houve uma correlação boa entre o Gated SPECT e a ressonância magnética cardíaca nos pacientes após CRM em relação à fração de ejeção do ventrículo esquerdo (ρ = 0,85; p = 0,0001), uma correlação moderada para o volume sistólico final (ρ = 0,51; p = 0,02) e uma correlação insignificante para o volume diastólico final (ρ = 0,13; p = 0,5). Os limites de concordância para FEVE, VSF e VDF foram: de -20% a 12%; de -38 a 54ml e de -96 a 100ml, respectivamente. CONCLUSÃO: A fração de ejeção do ventrículo esquerdo obtida pelo Gated SPECT correlaciona-se de modo confiável com a da ressonância magnética em pacientes submetidos à CRM. Os volumes ventriculares, entretanto, não apresentam uma correlação adequada.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

FUNDAMENTO: O choque cardiogênico e o edema agudo de pulmão são as principais causas de óbito em pacientes com escorpionismo, cujo mecanismo fisiopatológico ainda é controverso. OBJETIVOS: Investigar a correlação entre os distúrbios da perfusão miocárdica e a função contrátil do ventrículo esquerdo, em vítimas de escorpionismo. MÉTODOS: Quinze pacientes submeteram-se à cintilografia de perfusão miocárdica sincronizada com ECG (Gated SPECT), dentro de 72 horas e 15 dias após o acidente escorpiônico. As imagens foram analisadas visualmente por escore semiquantitativo de perfusão (0 = normal, 4 = ausente) e mobilidade (0 = normal, 4 = acinético), utilizando modelo de 17 segmentos. Para cada paciente foram calculados escores somados de perfusão (ESP) e mobilidade (ESM). A fração de ejeção (FEVE) foi calculada por software comercialmente disponível. RESULTADOS: Na avaliação inicial, 12 dos 15 pacientes apresentaram alterações da contratilidade e da perfusão miocárdica. O ESP foi de 12,5 ± 7,3, o ESM de 17,0 ± 12, 8 e a FEVE de 44,6 ± 16,0%. Houve correlação positiva entre o ESP e o ESM (r = 0,68; p = 0,005) e negativa entre o ESP e a FEVE (r = -0,75; p = 0,0021). Os estudos de seguimento mostraram recuperação da contratilidade global (FEVE de 68,9 ± 9,5, p = 0,0002), segmentar (ESM 2,6 ± 3,1, p = 0,0009) e da perfusão (ESP 3,7 ± 3,3, p = 0,0003). A melhora da FEVE correlacionou-se positivamente com a melhora do ESP (r = 0,72; p = 0,0035). CONCLUSÕES: Alterações perfusionais miocárdicas são comuns no envenenamento escorpiônico e correlacionam-se topograficamente com a disfunção contrátil. A recuperação da contratilidade correlaciona-se com a reversibilidade dos defeitos perfusionais. Estes achados sugerem a participação de alterações perfusionais miocárdicas na fisiopatologia desta forma de insuficiência ventricular aguda. (Arq Bras Cardiol 2010;94(4): 444-451)

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Objectius: Valorar el significat dels defectes paradoxals (DP) segmentaris (captació en esforç més gran que en repòs) a la gated-SPECT (Single Photon Emission Computer Tomography) de perfusió miocàrdica amb compostos tecneciats en regions amb necrosi miocàrdica. Material i mètodes: Es van revisar 1764 SPECT de perfusió miocàrdica estrès-repòs consecutives de pacients amb infart (IM) previ i es van identificar 117 pacients (6,6%) en els quals els DPs corresponien a una regió amb necrosi miocàrdica. Es van valorar els criteris gammagràfics de viabilitat (intensitat del defecte, valor d'aquesta intensitat ponderat pel nombre de segments compromesos-VIP-, la motilitat i l'engrossiment miocàrdic sistòlic) en els segments d'aquestes regions i les característiques de l'artèria responsable en els 96 pacients en els quals s'havia practicat una coronariografia. Resultats: Es van analitzar 160 necrosis, 125 (75%) paradoxals (67 (54%) en regió AnteroSeptoApical i 58 (46%) en regió InferoLateral) i 35 (25%) no paradoxals (19 (54%) ASA i 16 ( 46%) IL). Els valors de severitat de la necrosi i del VIP van ser inferiors en l'estudi d'estrès respecte al repòs i la diferència d'aquests va ser sempre negativa, evidenciant un comportament gammagràfic paradoxal. Per contra, aquests valors van ser inferiors al repòs respecte a l'estrès en les necrosi no paradoxals posant de manifest un comportament gammagràfic de mínima o nul reversibilitat. Així mateix, es van trobar alteracions lleus en la motilitat i engrossiment de les necrosi paradoxals i moderats en les necrosi no paradoxals. Es van trobar 102 necrosis amb DP i coronariografia dels quals, 84 (88%) tenien permeabilitat a l'artèria responsable de la necrosi i 12 pacients (12%) tenien circulació colateral per compensar l'oclusió de l'artèria responsable. Conclusions: Tots els segments amb DP en regions amb necrosi complien criteris gammagràfics de viabilitat en les imatges d'estrès, considerant aquestes imatges millors per a l'avaluació d'aquest tipus de lesions. El vas responsable de la regió amb DP es trobava permeable o bé presentava circulació colateral evident en els casos en què la coronària es trobava closa.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

A crucial method for investigating patients with coronary artery disease (CAD) is the calculation of the left ventricular ejection fraction (LVEF). It is, consequently, imperative to precisely estimate the value of LVEF--a process that can be done with myocardial perfusion scintigraphy. Therefore, the present study aimed to establish and compare the estimation performance of the quantitative parameters of the reconstruction methods filtered backprojection (FBP) and ordered-subset expectation maximization (OSEM). METHODS: A beating-heart phantom with known values of end-diastolic volume, end-systolic volume, and LVEF was used. Quantitative gated SPECT/quantitative perfusion SPECT software was used to obtain these quantitative parameters in a semiautomatic mode. The Butterworth filter was used in FBP, with the cutoff frequencies between 0.2 and 0.8 cycles per pixel combined with the orders of 5, 10, 15, and 20. Sixty-three reconstructions were performed using 2, 4, 6, 8, 10, 12, and 16 OSEM subsets, combined with several iterations: 2, 4, 6, 8, 10, 12, 16, 32, and 64. RESULTS: With FBP, the values of end-diastolic, end-systolic, and the stroke volumes rise as the cutoff frequency increases, whereas the value of LVEF diminishes. This same pattern is verified with the OSEM reconstruction. However, with OSEM there is a more precise estimation of the quantitative parameters, especially with the combinations 2 iterations × 10 subsets and 2 iterations × 12 subsets. CONCLUSION: The OSEM reconstruction presents better estimations of the quantitative parameters than does FBP. This study recommends the use of 2 iterations with 10 or 12 subsets for OSEM and a cutoff frequency of 0.5 cycles per pixel with the orders 5, 10, or 15 for FBP as the best estimations for the left ventricular volumes and ejection fraction quantification in myocardial perfusion scintigraphy.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The purposes of this study were to characterize the performance of a 3-dimensional (3D) ordered-subset expectation maximization (OSEM) algorithm in the quantification of left ventricular (LV) function with (99m)Tc-labeled agent gated SPECT (G-SPECT), the QGS program, and a beating-heart phantom and to optimize the reconstruction parameters for clinical applications. METHODS: A G-SPECT image of a dynamic heart phantom simulating the beating left ventricle was acquired. The exact volumes of the phantom were known and were as follows: end-diastolic volume (EDV) of 112 mL, end-systolic volume (ESV) of 37 mL, and stroke volume (SV) of 75 mL; these volumes produced an LV ejection fraction (LVEF) of 67%. Tomographic reconstructions were obtained after 10-20 iterations (I) with 4, 8, and 16 subsets (S) at full width at half maximum (FWHM) gaussian postprocessing filter cutoff values of 8-15 mm. The QGS program was used for quantitative measurements. RESULTS: Measured values ranged from 72 to 92 mL for EDV, from 18 to 32 mL for ESV, and from 54 to 63 mL for SV, and the calculated LVEF ranged from 65% to 76%. Overall, the combination of 10 I, 8 S, and a cutoff filter value of 10 mm produced the most accurate results. The plot of the measures with respect to the expectation maximization-equivalent iterations (I x S product) revealed a bell-shaped curve for the LV volumes and a reverse distribution for the LVEF, with the best results in the intermediate range. In particular, FWHM cutoff values exceeding 10 mm affected the estimation of the LV volumes. CONCLUSION: The QGS program is able to correctly calculate the LVEF when used in association with an optimized 3D OSEM algorithm (8 S, 10 I, and FWHM of 10 mm) but underestimates the LV volumes. However, various combinations of technical parameters, including a limited range of I and S (80-160 expectation maximization-equivalent iterations) and low cutoff values (< or =10 mm) for the gaussian postprocessing filter, produced results with similar accuracies and without clinically relevant differences in the LV volumes and the estimated LVEF.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The purpose of this study was to evaluate a free-breathing three-dimensional (3D) dual inversion-recovery (DIR) segmented k-space gradient-echo (turbo field echo [TFE]) imaging sequence at 3T for the quantification of aortic vessel wall dimensions. The effect of respiratory motion suppression on image quality was tested. Furthermore, the reproducibility of the aortic vessel wall measurements was investigated. Seven healthy subjects underwent 3D DIR TFE imaging of the aortic vessel wall with and without respiratory navigator. Subsequently, this sequence with respiratory navigator was performed twice in 10 healthy subjects to test its reproducibility. The signal-to-noise (SNR), contrast-to-noise ratio (CNR), vessel wall sharpness, and vessel wall volume (VWV) were assessed. Data were compared using the paired t-test, and the reproducibility of VWV measurements was evaluated using intraclass correlation coefficients (ICCs). SNR, CNR, and vessel wall sharpness were superior in scans performed with respiratory navigator compared to scans performed without. The ICCs concerning intraobserver, interobserver, and interscan reproducibility were excellent (0.99, 0.94, and 0.95, respectively). In conclusion, respiratory motion suppression substantially improves image quality of 3D DIR TFE imaging of the aortic vessel wall at 3T. Furthermore, this optimized technique with respiratory motion suppression enables assessment of aortic vessel wall dimensions with high reproducibility.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Simulation is a useful tool in cardiac SPECT to assess quantification algorithms. However, simple equation-based models are limited in their ability to simulate realistic heart motion and perfusion. We present a numerical dynamic model of the left ventricle, which allows us to simulate normal and anomalous cardiac cycles, as well as perfusion defects. Bicubic splines were fitted to a number of control points to represent endocardial and epicardial surfaces of the left ventricle. A transformation from each point on the surface to a template of activity was made to represent the myocardial perfusion. Geometry-based and patient-based simulations were performed to illustrate this model. Geometry-based simulations modeled ~1! a normal patient, ~2! a well-perfused patient with abnormal regional function, ~3! an ischaemic patient with abnormal regional function, and ~4! a patient study including tracer kinetics. Patient-based simulation consisted of a left ventricle including a realistic shape and motion obtained from a magnetic resonance study. We conclude that this model has the potential to study the influence of several physical parameters and the left ventricle contraction in myocardial perfusion SPECT and gated-SPECT studies.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

INTRODUCTION: Visual analysis is widely used to interpret regional cerebral blood flow (rCBF) SPECT images in clinical practice despite its limitations. Automated methods are employed to investigate between-group rCBF differences in research Studies but have rarely been explored in individual analyses.OBJECTIVES: To compare visual inspection by nuclear physicians with the automated statistical parametric mapping program using a SPECT dataset of patients with neurological disorders and normal control images.METHODS: Using statistical parametric mapping, 14 SPECT images from patients with various neurological disorders were compared individually with a databank of 32 normal images using a statistical threshold of p<0.05 (corrected for multiple comparisons at the level of individual voxels or clusters). Statistical parametric mapping results were compared with Visual analyses by a nuclear physician highly experienced in neurology (A) as well as a nuclear physician with a general background of experience (B) who independently classified images as normal or altered, and determined the location of changes and the severity.RESULTS: of the 32 images of the normal databank, 4 generated maps showing rCBF abnormalities (p<0.05, corrected). Among the 14 images from patients with neurological disorders, 13 showed rCBF alterations. Statistical parametric mapping and physician A completely agreed on 84.37% and 64.28% of cases from the normal databank and neurological disorders, respectively. The agreement between statistical parametric mapping and ratings of physician B were lower (71.18% and 35.71%, respectively).CONCLUSION: Statistical parametric mapping replicated the findings described by the more experienced nuclear physician. This finding suggests that automated methods for individually analyzing rCBF SPECT images may be a valuable resource to complement visual inspection in clinical practice.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The coronary artery calcium (CAC) score is a readily and widely available tool for the noninvasive diagnosis of atherosclerotic coronary artery disease (CAD). The aim of this study was to investigate the added value of the CAC score as an adjunct to gated SPECT for the assessment of CAD in an intermediate-risk population. METHODS: Seventy-seven prospectively recruited patients with intermediate risk (as determined by the Framingham Heart Study 10-y CAD risk score) and referred for coronary angiography because of suspected CAD underwent stress (99m)Tc-tetrofosmin SPECT myocardial perfusion imaging (MPI) and CT CAC scoring within 2 wk before coronary angiography. The sensitivity and specificity of SPECT alone and of the combination of the 2 methods (SPECT plus CAC score) in demonstrating significant CAD (>/=50% stenosis on coronary angiography) were compared. RESULTS: Forty-two (55%) of the 77 patients had CAD on coronary angiography, and 35 (45%) had abnormal SPECT results. The CAC score was significantly higher in subjects with perfusion abnormalities than in those who had normal SPECT results (889 +/- 836 [mean +/- SD] vs. 286 +/- 335; P < 0.0001). Similarly, with rising CAC scores, a larger percentage of patients had CAD. Receiver-operating-characteristic analysis showed that a CAC score of greater than or equal to 709 was the optimal cutoff for detecting CAD missed by SPECT. SPECT alone had a sensitivity and a specificity for the detection of significant CAD of 76% and 91%, respectively. Combining SPECT with the CAC score (at a cutoff of 709) improved the sensitivity of SPECT (from 76% to 86%) for the detection of CAD, in association with a nonsignificant decrease in specificity (from 91% to 86%). CONCLUSION: The CAC score may offer incremental diagnostic information over SPECT data for identifying patients with significant CAD and negative MPI results.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A method to compute three-dimension (3D) left ventricle (LV) motion and its color coded visualization scheme for the qualitative analysis in SPECT images is proposed. It is used to investigate some aspects of Cardiac Resynchronization Therapy (CRT). The method was applied to 3D gated-SPECT images sets from normal subjects and patients with severe Idiopathic Heart Failure, before and after CRT. Color coded visualization maps representing the LV regional motion showed significant difference between patients and normal subjects. Moreover, they indicated a difference between the two groups. Numerical results of regional mean values representing the intensity and direction of movement in radial direction are presented. A difference of one order of magnitude in the intensity of the movement on patients in relation to the normal subjects was observed. Quantitative and qualitative parameters gave good indications of potential application of the technique to diagnosis and follow up of patients submitted to CRT.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This study investigated the effect of a pool of peptides, isolated from venom of Crotalus durissus terrificus (South American rattlesnake) on glucose concentration in C57BL/6 mice fed on a high-fat diet for 6 weeks. The pool of peptides (molecular mass around of 10 kDa) was obtained using a MidJet apparatus with a cartridge of 10 KDa. The peptide pool was injected intraperitoneally in mice in a single dose (0.5 mg/animal) or multiple doses (0.2 mg/dose). After predetermined times (30, 60, 90 and 120 min) post injections, venous blood samples were collected for enzymatic measurement of serum glucose using a commercial glucose kit (glucose oxidase method). High-fat fed mice showed an increase in blood glucose concentration, in comparison with mice fed on the chow diet. Thirty minutes after a single dose of the peptide pool, high-fat fed animals showed a significant decrease (similar to 47%) in glycemia. However, the glucose level increased again at 60 and 120 min. Conversely, after multiple injections of the pool of peptides administered every 30 min, the blood glucose concentration in the high-fat mice was significantly decreased (similar to 37%) and remained at low levels until 120 min. These results suggest that the tested pool of peptides from Crotalus durissus terrificus contained a peptide (or peptides) with a beneficial role on glucose-lowering action of high-fat fed mice.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

(99m)Tc-MIBI gated myocardial scintigraphy (GMS) evaluates myocyte integrity and perfusion, left ventricular (LV) dyssynchrony and function. Cardiac resynchronization therapy (CRT) may improve the clinical symptoms of heart failure (HF), but its benefits for LV function are less pronounced. We assessed whether changes in myocardial (99m)Tc-MIBI uptake after CRT are related to improvement in clinical symptoms, LV synchrony and performance, and whether GMS adds information for patient selection for CRT. A group of 30 patients with severe HF were prospectively studied before and 3 months after CRT. Variables analysed were HF functional class, QRS duration, LV ejection fraction (LVEF) by echocardiography, myocardial (99m)Tc-MIBI uptake, LV end-diastolic volume (EDV) and end-systolic volume (ESV), phase analysis LV dyssynchrony indices, and regional motion by GMS. After CRT, patients were divided into two groups according to improvement in LVEF: group 1 (12 patients) with increase in LVEF of 5 or more points, and group 2 (18 patients) without a significant increase. After CRT, both groups showed a significant improvement in HF functional class, reduced QRS width and increased septal wall (99m)Tc-MIBI uptake. Only group 1 showed favourable changes in EDV, ESV, LV dyssynchrony indices, and regional motion. Before CRT, EDV, and ESV were lower in group 1 than in group 2. Anterior and inferior wall (99m)Tc-MIBI uptakes were higher in group 1 than in group 2 (p < 0.05). EDV was the only independent predictor of an increase in LVEF (p=0.01). The optimal EDV cut-off point was 315 ml (sensitivity 89%, specificity 94%). The evaluation of EDV by GMS added information on patient selection for CRT. After CRT, LVEF increase occurred in hearts less dilated and with more normal (99m)Tc-MIBI uptake.