967 resultados para Fusão caruncular
Resumo:
Being the surface roughness a fundamental property in the fit of the castings, it was determined the roughness of 5 high-copper casting alloys, according to the heating over their melting temperature. That way, the specimens made with smooth plastic in the shape of a rectangular plate, 2 mm x 7 mm x 11 mm were invested into a cristobalite investment. After heating and elimination on the plastic, the molds were filled by 3 g of molten alloy, casted in a electrical casting machine at the casting temperature at 25 degrees C and 50 degrees C overheating. The surface roughness was measured in a roughness analyser, Talysurf. As a result, it was verified that there is a variation of surface roughness among the alloys tested, and the heating of the alloys until 50 degrees C over the melting temperature does not interfere in the roughness.
Resumo:
It was evaluated the castability of four copper-aluminium alloy according the melting casting method used. The specimens were made using polyester mesh screen, with 11 x 11 filaments of 0.26 mm thick, fixed along of two adjacent edges in wax bar, with the sprue attached at their junction. The alloys were in an electrical casting machine and a centrifugal casting machine with an air/gas torch. The castability values were obtained by the percentage of completed segments of the resulting cast alloy screen. It was verified that the use of the electrical casting machine produced higher castability values to the copper-aluminium alloys than those produced by a centrifugal casting machine with an air/gas torch.
Resumo:
It was evaluated the Vickers hardness of five high-copper casting alloys, in their original package form and after casting, according to the casting method used. That way, ten ingots, supplied by the manufacturers of each alloy, were included in self-curing acrylic resin, polished, numerated and submitted to Vickers hardness test at load of 200 g during 30 seconds. Afterwards the numerated ingots were removed from the acrylic resin and five of those were cast in an electrical casting machine and the other five in a centrifugal casting machine with an air/gas torch. The specimens obtained were included in self-curing acrylic resin, polished and submitted to Vickers hardness test. As a result it was verified that there is a variation of hardness among the alloys tested, and the use of the electrical casting machine produced lower hardness values than those produced when used the centrifugal casting machine with an air/gas torch. Also, there is a decrease of hardness of the cast alloys when they are tested in their original form and after casting.
Resumo:
The authors looked for the verification of the fatigue of retentive clasps utilized on the removable partial denture. According to this, it was idealized and built on assay machine, that through movements, simulate the insertion and removal of the clasp for a pattern tooth, manufactured on cobalt-chromium which has all the preparation normally utilized to the correct confection of this type of prosthesis. It was utilized three different commercial alloys based on cobalt-chromium: L1-Biosil; L2-Steldent; L3-Duracron. It was utilized the T clasp of Roach, with was tested upon three different proportions among width and thickness: E1-1.7;E2-2.0 and E3-2.3 and was casted through two casting techniques: F1-oxygen-gas and F2-oxygen-acetylene. The clasps were tested on the machine, which allowed the reading of the number of insertion and removal cycles made until fatigue appeared. The obtained results were submitted to the statistic analysis and the authors concluded that: a) L3 (Duracrom) obtained the best results followed by L1 (Biosil) and finally L3 (Steldent); b) among the analyzed thickness, the best results were obtained by E3, followed by E2 and after this E1; c) form the casting techniques, F2 gave us the best results.
Resumo:
The authors tested the T clasp of Roach in three differents proportions among width and thickness: E1-1.7; E2-2.0 and E3-2.3, with a constant length of 15 mm. These clasps were casted with three cobalt-chromium alloys (L1-Biosil; L2-Steldent and L3-Duracrom), through two casting techniques (F1-oxygen-gas and F2-oxygen-acetylene). The fatigue of the clasps were verified by using and assay machine, that through movements, simulate the insertion and removal of the clasps for a pattern which were obtained from a premolar, prepared in a surveyor. This machine detect the fatigue of the clasps and count the number of cycles of insertion and removal realized. The obtained results of the interaction between the analysed factors, were submitted to the statistic analysis and the authors concluded that: a) the interaction of factors, Alloy x Thickness, Alloy x Casting Technique and Thickness x Casting Technique did not change the order of effects that the factors showed separately but gave rise to effects of different magnitude for any observed sense; b) the simultaneous interaction of the factors Alloy x Thickness x Casting Technique confirmed the superiority of the L3 alloy, the thickness E3 and the F2 casting technique.
Resumo:
Objective: To investigate the relationship between the presence of meiotic spindle in human oocytes and fertilization rates in ICSI cycles. Methods: Search strategies included online surveys of databases from 1990 to 2008. Nine trials fulfilled the inclusion criteria Results: According to the meta-analysis, the results showed statistically significant higher fertilization rate (p<0.0001) when the meiotic spindle was viewed than when it was not. There was heterogeneity in this comparison. Conclusion: The presence of a birefringent meiotic spindle in human oocytes can predict a higher fertilization rate. This observation has clinical relevance mainly in countries where there is a legal limit on the number of oocytes to be fertilized. Copyright - SBRA - Sociedade Brasileira de Reprodução Assistida.
Resumo:
This study aims to evaluate safety and effectiveness of the use of orthesis in postoperative degenerative disorders of the cervical spine. Although widely used, there are not defined criteria for the use of cervical collars, and their importance on cervical arthrodesis. A systematic literature review was undertaken and a multicentre controlled clinical trial comprising 32 specialized services, with a total of 257 patients who met the inclusion criteria of the review. Clinical and radiographic outcomes were compared in post surgical patients that used or not rigid cervical collar during 6 to 12 weeks after surgery. The evidence available on literature, although weak, suggests that cervical collar decreases the clinical scores in first weeks after surgery. Furthermore, it does not alter the rate of fusion when used concomitantly with plaque and screws through anterior access in cervical degenerative diseases on a single anatomical level.
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Pós-graduação em Pesquisa e Desenvolvimento (Biotecnologia Médica) - FMB
Resumo:
Pós-graduação em Ciências Odontológicas - FOAR
Resumo:
Pós-graduação em Matematica Aplicada e Computacional - FCT
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Pós-graduação em Ciência da Computação - IBILCE
Resumo:
A fusão de imagens multisensor tem sido um procedimento amplamente utilizado em função da natureza complementar dos vários conjuntos de dados. Este artigo compara o desempenho de quatro métodos diferentes para fusão de imagens Landsat-7 ETM+ e RADARSAT-1 W1. A comparação foi baseada nas características espectrais das imagens, utilizando-se de análise estatística e visual dos produtos gerados. Quatro métodos foram usados para a fusão das imagens Landsat-7 ETM+ e RADARSAT-1 W1: i) fusão do SAR (radar de abertura sintética) com a tríade selecionada pelo OIF (Optimum Index Factor); ii) realce por decorrelação da tríade selecionada pelo OIF, seguida da fusão com SAR; iii) ACP (Análise por Componentes Principais) para as seis bandas ETM+ do espectro refletido (1, 2, 3, 4, 5 e 7) e posterior fusão das três primeiras componentes principais (1CP; 2CP; 3CP) com o SAR; iv) SPC-SAR (Principal Componente Seletivo - SAR). O produto SPC-SAR mostrou melhor desempenho na identificação das feições costeiras e permitiu o realce mais efetivo dos diferentes ambientes.