939 resultados para Finger Phalanges


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Several studies have reported alterations in finger and a-b ridge counts, and theirderived measures of asymmetry, in schizophrenia compared to controls. Because ridges are fully formed by the end of the second trimester, they may provide clues to disturbed early development. The aim of this study was to assess these measures in a sample of patients with psychosis and normal controls.Methods: Individuals with psychosis (n = 240), and normal controls (n = 228) were drawn from a catchment-area case-control study. Differences in finger and a-b ridge count and Fluctuating Asymmetry were assessed in three group comparisons (non-affective psychosis versus controls; affective psychosis versus controls; non-affective psychosis versus affective psychosis). The analyses were performed separately for males and females. Results: There were no significant group differences for finger nor a-b ridge counts. While there were no group difference for Directional Asymmetry, for Fluctuating Asymmetry measures men with non-affective psychosis had significantly higher fluctuating asymmetry of the index finger ridge count (a) when compared to controls (FA-correlation score, p = 0.02), and (b) when compared to affective psychosis (adjusted FA-difference score, p = 0.04). Conclusion: Overall, measures of finger and a-b ridge counts, and their derived measures of directional and fluctuating asymmetry were not prominent features of psychosis in this sample. While directional asymmetry in cerebral morphology is reduced in schizophrenia, this is not reflected in dermatoglyphic variables.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The purpose for the thesis was to study the thermo treatment of finger-jointed wood. The thesis concentrated on examining the tensile and bending strength of finger-jointed and thermo treated wood. The aim was to find out how different treatment temperature levels and adhesives influence the strength of wood that has been finger-jointed before heat treatment. Secondary objectives were to examine the influence of the treatment time at one temperature, determine differences in the strength between the joints in heartwood and sapwood, examine the visual appearance of the finger joints after the treatment and establish possibilities to reach a characteristic strength level corresponding to C14. Only minor differences in strength properties were measured between the finger-jointed wood treatments II and III. A greater difference was shown between these two treatment temperatures I, which lead to reduced strength. The average strength of joints glued with adhesive 2 was higher after treatments II and III compared to those glued with the adhesive 1. At the treatment temperature I, the adhesive 1 strength properties were at the same level compared to the adhesive 2 or better. There were not any significant differences.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Abstract: The knowledge of anatomical structures found in wild animals is important for the practice of medical and surgical clinic. Thus, the aim of this study was to describe the osteology and radiographic anatomy of the femur, patella, tibia, fibula, tarsal, metatarsal and phalanges of the Marshdeer Blastocerus dichotomus as a reference for clinical use and species identification. Most structures were similar to those found in domestic animals, with special features of this species. Noteworthy is, for example, the absence of the third trochanter of the femur. Although a ruminant, the Marshdeer has a fibuyla similar to the one described for the horse. B. dichotomus has four fingers on each limb, formed through three phalanges, only the third and fourth finger touch the ground, and the second and fifth finger is rudimentary. It has four proximal and two distal sesamoid bones, and sesamoid bones near the gastrocnemius muscle do not exist.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Almost identical polyglutamine-containing proteins with unknown structures have been found in human, mouse and rat genomes (GenBank AJ277365, AF525300, AY879229). We infer that an identical new gene (RING) finger domain of real interest is located in each C-terminal segment. A three-dimensional (3-D) model was generated by remote homology modeling and the functional implications are discussed. The model consists of 65 residues from terminal position 707 to 772 of the human protein with a total length of 796 residues. The 3-D model predicts a ubiquitin-protein ligase (E3) as a binding site for ubiquitin-conjugating enzyme (E2). Both enzymes are part of the ubiquitin pathway to label unwanted proteins for subsequent enzymatic degradation. The molecular contact specificities are suggested for both the substrate recognition and the residues at the possible E2-binding surface. The predicted structure, of a ubiquitin-protein ligase (E3, enzyme class number 6.3.2.19, CATH code 3.30.40.10.4) may contribute to explain the process of ubiquitination. The 3-D model supports the idea of a C3HC4-RING finger with a partially new pattern. The putative E2-binding site is formed by a shallow hydrophobic groove on the surface adjacent to the helix and one zinc finger (L722, C739, P740, P741, R744). Solvent-exposed hydrophobic amino acids lie around both zinc fingers (I717, L722, F738, or P765, L766, V767, V733, P734). The 3-D structure was deposited in the protein databank theoretical model repository (2B9G, RCSB Protein Data Bank, NJ).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Myocardial ischemic preconditioning upregulated protein 1 (Mipu1) is a newly discovered upregulated gene produced in rats during the myocardial ischemic preconditioning process. Mipu1 cDNA contains a 1824-base pair open reading frame and encodes a 608 amino acid protein with an N-terminal Krüppel-associated box (KRAB) domain and classical zinc finger C2H2 motifs in the C-terminus. Mipu1 protein is located in the cell nucleus. Recent studies found that Mipu1 has a protective effect on the ischemia-reperfusion injury of heart, brain, and other organs. As a nuclear factor, Mipu1 may perform its protective function through directly transcribing and repressing the expression of proapoptotic genes to repress cell apoptosis. In addition, Mipu1 also plays an important role in regulating the gene expression of downstream inflammatory mediators by inhibiting the activation of activator protein-1 and serum response element.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The goal of this research is to develop the prototype of a tactile sensing platform for anthropomorphic manipulation research. We investigate this problem through the fabrication and simple control of a planar 2-DOF robotic finger inspired by anatomic consistency, self-containment, and adaptability. The robot is equipped with a tactile sensor array based on optical transducer technology whereby localized changes in light intensity within an illuminated foam substrate correspond to the distribution and magnitude of forces applied to the sensor surface plane. The integration of tactile perception is a key component in realizing robotic systems which organically interact with the world. Such natural behavior is characterized by compliant performance that can initiate internal, and respond to external, force application in a dynamic environment. However, most of the current manipulators that support some form of haptic feedback either solely derive proprioceptive sensation or only limit tactile sensors to the mechanical fingertips. These constraints are due to the technological challenges involved in high resolution, multi-point tactile perception. In this work, however, we take the opposite approach, emphasizing the role of full-finger tactile feedback in the refinement of manual capabilities. To this end, we propose and implement a control framework for sensorimotor coordination analogous to infant-level grasping and fixturing reflexes. This thesis details the mechanisms used to achieve these sensory, actuation, and control objectives, along with the design philosophies and biological influences behind them. The results of behavioral experiments with a simple tactilely-modulated control scheme are also described. The hope is to integrate the modular finger into an %engineered analog of the human hand with a complete haptic system.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Para utilizar en los primeros años del desarrollo del habla como una forma muy simple de dramatización.. A menudo se emplea como ayuda terapéutica con el niño que sufre dificultades del habla. Útil como ayuda en el desarrollo integral de niños de tres a siete años ya que al verso acompaña simultáneamente la acción de ejercicios con los dedos, la motricidad gruesa y la coordinación del cuerpo.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Single point interaction haptic devices do not provide the natural grasp and manipulations found in the real world, as afforded by multi-fingered haptics. The present study investigates a two-fingered grasp manipulation involving rotation with and without force feedback. There were three visual cue conditions: monocular, binocular and projective lighting. Performance metrics of time and positional accuracy were assessed. The results indicate that adding haptics to an object manipulation task increases the positional accuracy but slightly increases the overall time taken.