928 resultados para Field calibration method
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Throughout the world, biomonitoring has become the standard for assessing exposure of individuals to toxic elements as well as for responding to serious environmental public health problems. However, extensive biomonitoring surveys require rapid and simple analytical methods. Thus, a simple and high-throughput method is proposed for the determination of arsenic (As), cadmium (Cd), copper (Cu), manganese (Mn), nickel (Ni), lead (Pb), and selenium (Se) in blood samples by using inductively coupled plasma–mass spectrometry (ICPMS). Prior to analysis, 200 ml of blood samples was mixed with 500 ml of 10% v/v tetramethylammonium hydroxide (TMAH) solution, incubated for 10 min, and subsequently diluted to 10 ml with a solution containing 0.05% w/v ethylenediamine tetraacetic acid (EDTA) + 0.005% v/v Triton X-100. After that, samples were directly analyzed by ICP-MS (ELAN DRC II). Rhodium was selected as an internal standard with matrix-matching calibration. Method detection limits were 0.08, 0.04, 0.5, 0.09, 0.12, 0.04, and 0.1 mg//L for As, Cd, Cu, Mn, Ni, Pb, and Se, respectively. Validation data are provided based on the analysis of blood samples from the trace elements inter-\comparison program operated by the Institut National de Santé Publique du Quebec, Canada. Additional validation was provided by the analysis of human blood samples by the proposed method and by using electrothermal atomic absorption spectrometry (ETAAS). The method was subsequently applied for the estimation of background metal blood values in the Brazilian population. In general, the mean concentrations of As, Cd, Cu, Mn, Ni, Pb, and Se in blood were 1.1, 0.4, 890, 9.6, 2.1, 65.4, and 89.3 mg/L, respectively, and are in agreement with other global populations. Influences of age, gender, smoking habits, alcohol consumption, and geographical variation on the values were also considered. Smoking habits influenced the levels of Cd in blood. The levels of Cu, Mn, and Pb were significantly correlated with gender, whereas Cu and Pb were significantly correlated with age. There were also interesting differences in Mn and Se levels in the population living in the north of Brazil compared to the south.
Resumo:
Proton radiation therapy is gaining popularity because of the unique characteristics of its dose distribution, e.g., high dose-gradient at the distal end of the percentage-depth-dose curve (known as the Bragg peak). The high dose-gradient offers the possibility of delivering high dose to the target while still sparing critical organs distal to the target. However, the high dose-gradient is a double-edged sword: a small shift of the highly conformal high-dose area can cause the target to be substantially under-dosed or the critical organs to be substantially over-dosed. Because of that, large margins are required in treatment planning to ensure adequate dose coverage of the target, which prevents us from realizing the full potential of proton beams. Therefore, it is critical to reduce uncertainties in the proton radiation therapy. One major uncertainty in a proton treatment is the range uncertainty related to the estimation of proton stopping power ratio (SPR) distribution inside a patient. The SPR distribution inside a patient is required to account for tissue heterogeneities when calculating dose distribution inside the patient. In current clinical practice, the SPR distribution inside a patient is estimated from the patient’s treatment planning computed tomography (CT) images based on the CT number-to-SPR calibration curve. The SPR derived from a single CT number carries large uncertainties in the presence of human tissue composition variations, which is the major drawback of the current SPR estimation method. We propose to solve this problem by using dual energy CT (DECT) and hypothesize that the range uncertainty can be reduced by a factor of two from currently used value of 3.5%. A MATLAB program was developed to calculate the electron density ratio (EDR) and effective atomic number (EAN) from two CT measurements of the same object. An empirical relationship was discovered between mean excitation energies and EANs existing in human body tissues. With the MATLAB program and the empirical relationship, a DECT-based method was successfully developed to derive SPRs for human body tissues (the DECT method). The DECT method is more robust against the uncertainties in human tissues compositions than the current single-CT-based method, because the DECT method incorporated both density and elemental composition information in the SPR estimation. Furthermore, we studied practical limitations of the DECT method. We found that the accuracy of the DECT method using conventional kV-kV x-ray pair is susceptible to CT number variations, which compromises the theoretical advantage of the DECT method. Our solution to this problem is to use a different x-ray pair for the DECT. The accuracy of the DECT method using different combinations of x-ray energies, i.e., the kV-kV, kV-MV and MV-MV pair, was compared using the measured imaging uncertainties for each case. The kV-MV DECT was found to be the most robust against CT number variations. In addition, we studied how uncertainties propagate through the DECT calculation, and found general principles of selecting x-ray pairs for the DECT method to minimize its sensitivity to CT number variations. The uncertainties in SPRs estimated using the kV-MV DECT were analyzed further and compared to those using the stoichiometric method. The uncertainties in SPR estimation can be divided into five categories according to their origins: the inherent uncertainty, the DECT modeling uncertainty, the CT imaging uncertainty, the uncertainty in the mean excitation energy, and SPR variation with proton energy. Additionally, human body tissues were divided into three tissue groups – low density (lung) tissues, soft tissues and bone tissues. The uncertainties were estimated separately because their uncertainties were different under each condition. An estimate of the composite range uncertainty (2s) was determined for three tumor sites – prostate, lung, and head-and-neck, by combining the uncertainty estimates of all three tissue groups, weighted by their proportions along typical beam path for each treatment site. In conclusion, the DECT method holds theoretical advantages in estimating SPRs for human tissues over the current single-CT-based method. Using existing imaging techniques, the kV-MV DECT approach was capable of reducing the range uncertainty from the currently used value of 3.5% to 1.9%-2.3%, but it is short to reach our original goal of reducing the range uncertainty by a factor of two. The dominant source of uncertainties in the kV-MV DECT was the uncertainties in CT imaging, especially in MV CT imaging. Further reduction in beam hardening effect, the impact of scatter, out-of-field object etc. would reduce the Hounsfeld Unit variations in CT imaging. The kV-MV DECT still has the potential to reduce the range uncertainty further.
Resumo:
En esta tesis doctoral se describe el trabajo de investigación enfocado al estudio y desarrollo de sensores de fibra óptica para la detección de presión, flujo y vibraciones en ductos ascendentes submarinos utilizados en la extracción y transporte de hidrocarburos, con el objetivo de aplicarlos en los campos de explotación de aguas profundas en el Golfo de México pertenecientes a la Industria Petrolera Mexicana. El trabajo se ha enfocado al estudio y desarrollo de sensores ópticos cuasi distribuidos y distribuidos. En especial se ha profundizado en el uso y aplicación de las redes de Bragg (FBG) y de reflectómetros ópticos en el dominio del tiempo sensible a la fase (φ-OTDR). Los sensores de fibra óptica son especialmente interesantes para estas aplicaciones por sus ventajosas características como su inmunidad a interferencias electromagnéticas, capacidad de multiplexado, fiabilidad para trabajar en ambientes hostiles, altas temperaturas, altas presiones, ambientes salino-corrosivos, etc. Además, la fibra óptica no solo es un medio sensor sino que puede usarse como medio de transmisión. Se ha realizado un estudio del estado del arte y las ventajas que presentan los sensores ópticos puntuales, cuasi-distribuidos y distribuidos con respecto a los sensores convencionales. Se han estudiado y descrito los interrogadores de redes de Bragg y se ha desarrollado un método de calibración útil para los interrogadores existentes en el mercado, consiguiendo incertidumbres en la medida de la longitud de onda menores de ± 88 nm e incertidumbres relativas (la mas interesante en el campo de los sensores) menores de ±3 pm. Centrándose en la aplicación de las redes de Bragg en la industria del petróleo, se ha realizado un estudio en detalle del comportamiento que presentan las FBGs en un amplio rango de temperaturas de -40 ºC a 500 oC. Como resultado de este estudio se han evaluado las diferencias en los coeficientes de temperatura en diversos tramos de mas mismas, así como para diferentes recubrimientos protectores. En especial se ha encontrado y evaluado las diferencias de los diferentes recubrimientos en el intervalo de temperaturas entre -40 ºC y 60 ºC. En el caso del intervalo de altas temperaturas, entre 100 ºC y 500 ºC, se ha medido y comprobado el cambio uniforme del coeficiente de temperatura en 1pm/ºC por cada 100 ºC de aumento de temperatura, en redes independientemente del fabricante de las mismas. Se ha aplicado las FBG a la medición de manera no intrusiva de la presión interna en una tubería y a la medición del caudal de un fluido en una tubería, por la medida de diferencia de presión entre dos puntos de la misma. Además se ha realizado un estudio de detección de vibraciones en tuberías con fluidos. Finalmente, se ha implementado un sistema de detección distribuida de vibraciones aplicable a la detección de intrusos en las proximidades de los ductos, mediante un φ-OTDR. En este sistema se ha estudiado el efecto negativo de la inestabilidad de modulación que limita la detección de vibraciones distribuidas, su sensibilidad y su alcance. ABSTRACT This thesis describes the research work focused for the study and development of on optical fiber sensors for detecting pressure, flow and vibration in subsea pipes used in the extraction and transportation of hydrocarbons, in order to apply them in deepwater fields in the Gulf of Mexico belonging to the Mexican oil industry. The work has focused on the study and development of optical sensors distributed and quasi distributed. Especially was done on the use and application of fiber Bragg grating (FBG) and optical reflectometers time domain phase sensitive (φ-OTDR). The optical fiber sensors especially are interesting for these applications for their advantageous characteristics such as immunity to electromagnetic interference, multiplexing capability, reliability to work in harsh environments, high temperatures, high pressures, corrosive saline environments, etc. Furthermore, the optical fiber is not only a sensor means it can be used as transmission medium. We have performed a study of the state of the art and the advantages offered by optical sensors point, quasi-distributed and distributed over conventional sensors. Have studied and described interrogators Bragg grating and has developed a calibration method for interrogators useful for the existing interrogators in the market, resulting uncertainty in the measurement of the wavelength of less than ± 0.17 nm and uncertainties (the more interesting in the field of sensors) less than ± 3 pm. Focusing on the application of the Bragg gratings in the oil industry, has been studied in detail the behavior of the FBGs in a wide range of temperatures from -40 °C to 500 oC. As a result of this study we have evaluated the difference in temperature coefficients over various sections of the same, as well as different protective coatings. In particular evaluated and found the differences coatings in the range of temperatures between -40 º C and 60 º C. For the high temperature range between 20 ° C and 500 ° C, has been measured and verified the uniform change of the temperature coefficient at 1pm / ° C for each 100 ° C increase in temperature, in networks regardless of manufacturer thereof. FBG is applied to the non-intrusive measurement of internal pressure in a pipeline and measuring flow of a fluid in a pipe, by measuring the pressure difference between two points thereof. Therefore, has also made a study of detecting vibrations in pipes with fluids. Finally, we have implemented a distributed sensing system vibration applied to intrusion detection in the vicinity of the pipelines, by φ-OTDR. In this system we have studied the negative effect of modulation instability limits the distributed vibration detection, sensitivity and scope.
Resumo:
Far-field stresses are those present in a volume of rock prior to excavations being created. Estimates of the orientation and magnitude of far-field stresses, often used in mine design, are generally obtained by single-point measurements of stress, or large-scale, regional trends. Point measurements can be a poor representation of far-field stresses as a result of excavation-induced stresses and geological structures. For these reasons, far-field stress estimates can be associated with high levels of uncertainty. The purpose of this thesis is to investigate the practical feasibility, applications, and limitations of calibrating far-field stress estimates through tunnel deformation measurements captured using LiDAR imaging. A method that estimates the orientation and magnitude of excavation-induced principal stress changes through back-analysis of deformation measurements from LiDAR imaged tunnels was developed and tested using synthetic data. If excavation-induced stress change orientations and magnitudes can be accurately estimated, they can be used in the calibration of far-field stress input to numerical models. LiDAR point clouds have been proven to have a number of underground applications, thus it is desired to explore their use in numerical model calibration. The back-analysis method is founded on the superposition of stresses and requires a two-dimensional numerical model of the deforming tunnel. Principal stress changes of known orientation and magnitude are applied to the model to create calibration curves. Estimation can then be performed by minimizing squared differences between the measured tunnel and sets of calibration curve deformations. In addition to the back-analysis estimation method, a procedure consisting of previously existing techniques to measure tunnel deformation using LiDAR imaging was documented. Under ideal conditions, the back-analysis method estimated principal stress change orientations within ±5° and magnitudes within ±2 MPa. Results were comparable for four different tunnel profile shapes. Preliminary testing using plastic deformation, a rough tunnel profile, and profile occlusions suggests that the method can work under more realistic conditions. The results from this thesis set the groundwork for the continued development of a new, inexpensive, and efficient far-field stress estimate calibration method.
Resumo:
Purpose: This study was conducted to devise a new individual calibration method to enhance MTI accelerometer estimation of free-living level walking speed. Method: Five female and five male middle-aged adults walked 400 m at 3.5, 4.5, and 5.5 km(.)h(-1), and 800 in at 6.5 km(.)h(-1) on an outdoor track, following a continuous protocol. Lap speed was controlled by a global positioning system (GPS) monitor. MTI counts-to-speed calibration equations were derived for each trial, for each subject for four such trials with each of four MTI, for each subject for the average MTI. and for the pooled data. Standard errors of the estimate (SEE) with and without individual calibration were compared. To assess accuracy of prediction of free-living walking speed, subjects also completed a self-paced, brisk 3-km walk wearing one of the four MTI, and differences between actual and predicted walking speed with and without individual calibration were examined. Results: Correlations between MTI counts and walking speed were 0.90 without individual calibration, 0.98 with individual calibration for the average MTI. and 0.99 with individual calibration for a specific MTI. The SEE (mean +/- SD) was 0.58 +/- 0.30 km(.)h(-1) without individual calibration, 0.19 +/- 0.09 km h(-1) with individual calibration for the average MTI monitor, and 0.16 +/- 0.08 km(.)h(-1) with individual calibration for a specific MTI monitor. The difference between actual and predicted walking speed on the brisk 3-km walk was 0.06 +/- 0.25 km(.)h(-1) using individual calibration and 0.28 +/- 0.63 km(.)h(-1) without individual calibration (for specific accelerometers). Conclusion: MTI accuracy in predicting walking speed without individual calibration might be sufficient for population-based studies but not for intervention trials. This individual calibration method will substantially increase precision of walking speed predicted from MTI counts.
Resumo:
Purpose: To investigate the correlation between tests of visual function and perceived visual ability recorded with a 'quality-of-life' questionnaire for patients with central field loss. Method: 12 females and 7 males (mean age = 53.1 years; Range = 23 - 80 years) with subfoveal neovascular membranes underwent a comprehensive assessment of visual function. Tests included unaided distance vision, high and low contrast distance logMAR visual acuity (VA), Pelli-Robson contrast senstivity (at 1m), near logMAR word VA and text reading speed. All tests were done both monocularly and binocularly. The patients also completed a 28 point questionnaire separated into a 'core' section consisting of general questions about perceived visual function and a 'module' section with specific questions on reading function. Results: Step-wise multiple regression analysis was used to determine which visual function tests were correlated with the patients's perceived visual function and to rank them in order of importance. The visual function test that explains most of the variance in both 'core' score (66%0 and the 'module' score (68%) of the questionnaire is low contrast VA in the better eye (P<0.001 in both cases). Further, the module score also accounts for a significant proportion of the variance (P<0.01) of the distance logMAR VA in both the better and worse eye, and the near logMAR in both the better eye and binocularly. Conclusions: The best predictor of both perceived reading ability and of general perceived visual ability in this study is low contrast logMAR VA. The results highlight that distance VA is not the only relevant measure of visual fucntion in relation to a patients's perceived visual performance and should not be considered a determinant of surgical or management success.
Resumo:
This study was an evaluation of a Field Project Model Curriculum and its impact on achievement, attitude toward science, attitude toward the environment, self-concept, and academic self-concept with at-risk eleventh and twelfth grade students. One hundred eight students were pretested and posttested on the Piers-Harris Children's Self-Concept Scale, PHCSC (1985); the Self-Concept as a Learner Scale, SCAL (1978); the Marine Science Test, MST (1987); the Science Attitude Inventory, SAI (1970); and the Environmental Attitude Scale, EAS (1972). Using a stratified random design, three groups of students were randomly assigned according to sex and stanine level, to three treatment groups. Group one received the field project method, group two received the field study method, and group three received the field trip method. All three groups followed the marine biology course content as specified by Florida Student Performance Objectives and Frameworks. The intervention occurred for ten months with each group participating in outside-of-classroom activities on a trimonthly basis. Analysis of covariance procedures were used to determine treatment effects. F-ratios, p-levels and t-tests at p $<$.0062 (.05/8) indicated that a significant difference existed among the three treatment groups. Findings indicated that groups one and two were significantly different from group three with group one displaying significantly higher results than group two. There were no significant differences between males and females in performance on the five dependent variables. The tenets underlying environmental education are congruent with the recommendations toward the reform of science education. These include a value analysis approach, inquiry methods, and critical thinking strategies that are applied to environmental issues. ^
Resumo:
Far-field stresses are those present in a volume of rock prior to excavations being created. Estimates of the orientation and magnitude of far-field stresses, often used in mine design, are generally obtained by single-point measurements of stress, or large-scale, regional trends. Point measurements can be a poor representation of far-field stresses as a result of excavation-induced stresses and geological structures. For these reasons, far-field stress estimates can be associated with high levels of uncertainty. The purpose of this thesis is to investigate the practical feasibility, applications, and limitations of calibrating far-field stress estimates through tunnel deformation measurements captured using LiDAR imaging. A method that estimates the orientation and magnitude of excavation-induced principal stress changes through back-analysis of deformation measurements from LiDAR imaged tunnels was developed and tested using synthetic data. If excavation-induced stress change orientations and magnitudes can be accurately estimated, they can be used in the calibration of far-field stress input to numerical models. LiDAR point clouds have been proven to have a number of underground applications, thus it is desired to explore their use in numerical model calibration. The back-analysis method is founded on the superposition of stresses and requires a two-dimensional numerical model of the deforming tunnel. Principal stress changes of known orientation and magnitude are applied to the model to create calibration curves. Estimation can then be performed by minimizing squared differences between the measured tunnel and sets of calibration curve deformations. In addition to the back-analysis estimation method, a procedure consisting of previously existing techniques to measure tunnel deformation using LiDAR imaging was documented. Under ideal conditions, the back-analysis method estimated principal stress change orientations within ±5° and magnitudes within ±2 MPa. Results were comparable for four different tunnel profile shapes. Preliminary testing using plastic deformation, a rough tunnel profile, and profile occlusions suggests that the method can work under more realistic conditions. The results from this thesis set the groundwork for the continued development of a new, inexpensive, and efficient far-field stress estimate calibration method.
Resumo:
Il existe désormais une grande variété de lentilles panoramiques disponibles sur le marché dont certaines présentant des caractéristiques étonnantes. Faisant partie de cette dernière catégorie, les lentilles Panomorphes sont des lentilles panoramiques anamorphiques dont le profil de distorsion est fortement non-uniforme, ce qui cause la présence de zones de grandissement augmenté dans le champ de vue. Dans un contexte de robotique mobile, ces particularités peuvent être exploitées dans des systèmes stéréoscopiques pour la reconstruction 3D d’objets d’intérêt qui permettent à la fois une bonne connaissance de l’environnement, mais également l’accès à des détails plus fins en raison des zones de grandissement augmenté. Cependant, à cause de leur complexité, ces lentilles sont difficiles à calibrer et, à notre connaissance, aucune étude n’a réellement été menée à ce propos. L’objectif principal de cette thèse est la conception, l’élaboration et l’évaluation des performances de systèmes stéréoscopiques Panomorphes. Le calibrage a été effectué à l’aide d’une technique établie utilisant des cibles planes et d’une boîte à outils de calibrage dont l’usage est répandu. De plus, des techniques mathématiques nouvelles visant à rétablir la symétrie de révolution dans l’image (cercle) et à uniformiser la longueur focale (cercle uniforme) ont été développées pour voir s’il était possible d’ainsi faciliter le calibrage. Dans un premier temps, le champ de vue a été divisé en zones à l’intérieur desquelles la longueur focale instantanée varie peu et le calibrage a été effectué pour chacune d’entre elles. Puis, le calibrage général des systèmes a aussi été réalisé pour tout le champ de vue simultanément. Les résultats ont montré que la technique de calibrage par zone ne produit pas de gain significatif quant à la qualité des reconstructions 3D d’objet d’intérêt par rapport au calibrage général. Cependant, l’étude de cette nouvelle approche a permis de réaliser une évaluation des performances des systèmes stéréoscopiques Panomorphes sur tout le champ de vue et de montrer qu’il est possible d’effectuer des reconstructions 3D de qualité dans toutes les zones. De plus, la technique mathématique du cercle a produit des résultats de reconstructions 3D en général équivalents à l’utilisation des coordonnées originales. Puisqu’il existe des outils de calibrage qui, contrairement à celui utilisé dans ce travail, ne disposent que d’un seul degré de liberté sur la longueur focale, cette technique pourrait rendre possible le calibrage de lentilles Panomorphes à l’aide de ceux-ci. Finalement, certaines conclusions ont pu être dégagées quant aux facteurs déterminants influençant la qualité de la reconstruction 3D à l’aide de systèmes stéréoscopiques Panomorphes et aux caractéristiques à privilégier dans le choix des lentilles. La difficulté à calibrer les optiques Panomorphes en laboratoire a mené à l’élaboration d’une technique de calibrage virtuel utilisant un logiciel de conception optique et une boîte à outils de calibrage. Cette approche a permis d’effectuer des simulations en lien avec l’impact des conditions d’opération sur les paramètres de calibrage et avec l’effet des conditions de calibrage sur la qualité de la reconstruction. Des expérimentations de ce type sont pratiquement impossibles à réaliser en laboratoire mais représentent un intérêt certain pour les utilisateurs. Le calibrage virtuel d’une lentille traditionnelle a aussi montré que l’erreur de reprojection moyenne, couramment utilisée comme façon d’évaluer la qualité d’un calibrage, n’est pas nécessairement un indicateur fiable de la qualité de la reconstruction 3D. Il est alors nécessaire de disposer de données supplémentaires pour juger adéquatement de la qualité d’un calibrage.
Resumo:
Purpose: The precise shape of the three-dimensional dose distributions created by intensity-modulated radiotherapy means that the verification of patient position and setup is crucial to the outcome of the treatment. In this paper, we investigate and compare the use of two different image calibration procedures that allow extraction of patient anatomy from measured electronic portal images of intensity-modulated treatment beams. Methods and Materials: Electronic portal images of the intensity-modulated treatment beam delivered using the dynamic multileaf collimator technique were acquired. The images were formed by measuring a series of frames or segments throughout the delivery of the beams. The frames were then summed to produce an integrated portal image of the delivered beam. Two different methods for calibrating the integrated image were investigated with the aim of removing the intensity modulations of the beam. The first involved a simple point-by-point division of the integrated image by a single calibration image of the intensity-modulated beam delivered to a homogeneous polymethyl methacrylate (PMMA) phantom. The second calibration method is known as the quadratic calibration method and required a series of calibration images of the intensity-modulated beam delivered to different thicknesses of homogeneous PMMA blocks. Measurements were made using two different detector systems: a Varian amorphous silicon flat-panel imager and a Theraview camera-based system. The methods were tested first using a contrast phantom before images were acquired of intensity-modulated radiotherapy treatment delivered to the prostate and pelvic nodes of cancer patients at the Royal Marsden Hospital. Results: The results indicate that the calibration methods can be used to remove the intensity modulations of the beam, making it possible to see the outlines of bony anatomy that could be used for patient position verification. This was shown for both posterior and lateral delivered fields. Conclusions: Very little difference between the two calibration methods was observed, so the simpler division method, requiring only the single extra calibration measurement and much simpler computation, was the favored method. This new method could provide a complementary tool to existing position verification methods, and it has the advantage that it is completely passive, requiring no further dose to the patient and using only the treatment fields.
Resumo:
The photoelectron spectrum of the oxyallyl (OXA) radical anion has been measured. The radical anion has been generated in the reaction of the atomic oxygen radical anion (O center dot-) with acetone. Three low-lying electronic states of OXA have been observed in the spectrum. Electronic structure calculations have been performed for the triplet states (B-3(2) and B-3(1)) of OXA and the ground doublet state ((2)A(2)) of the radical anion using density, functional theory (DFT). Spectral simulations have been carried out for the triplet statics based on the results of the DFT calculations. The simulation identifies a vibrational progression of the CCC bending mode of the B-3(2) state of OXA in the lower electron binding energy (eBE) portion of the spectrum. On top of the B-3(2) feature, however, the experimental spectrum exhibits additional photoelectron peaks whose angular distribution is distinct from that for the vibronic peaks of the B-3(2) state. Complete active space self-consistent field (CASSCF) method and second-order perturbation theory based on the CASSCF wave function (CASPT2) have been employed to study the lowest singlet state ((1)A(1)) of OXA. The simulation based on the results of these electronic structure calculations establishes that the overlapping peaks represent the vibrational ground level of the (1)A(1) state and its vibrational progression of the CO stretching mode. The A, state is the lowest electronic state of,OXA, and the electron affinity (EA) of OXA is 1.940 +/- 0.010 eV. The B-3(2) state is the first excited state with an electronic term energy of 55 +/- 2 meV. The widths of the vibronic peaks of the (X) over tilde (1)A(1) state are much broader than those of the (a) over tilde B-3(2) state, implying that the (1)A(1) state is indeed a transition state. The CASSCF and CASPT2 calculations suggest that the (1)A(1) state is at a potential maximum along the nuclear coordinate representing disrotatory motion of the two methylene groups, which leads to three-membered-ring formation, i.e., cydopropanone. The simulation of (b) over tilde B-3(1) OXA reproduces the higher eBE portion of the spectrum very well. The term energy of the B-3(1) state is 0.883 +/- 0.012 eV. Photoelectron spectroscopic measurements have also been conducted for the other ion products of the O center dot- reaction with acetone. The photoelectron imaging spectrum of the acetylcarbene (AC) radical anion exhibits a broad, structureless feature, which is assigned to the (X) over tilde (3)A '' state of AC. The ground ((2)A '') and first excited ((2)A') states of the 1-methylvinoxy (1-MVO) radical have been observed in the photoelectron spectrum of the 1-MVO ion, and their vibronic structure has been analyzed.
Resumo:
Mikania micrantha Kunth (Asteraceae), commonly known as ‘mile-a-minute’, is a neotropical plant species now found in 17 Pacific island countries and territories, invading small cropping areas and plantations, thereby reducing productivity and food security. In 2006, a biocontrol project on M. micrantha commenced in Fiji and Papua New Guinea (PNG). The distribution of M. micrantha as well as baseline data such as plant growth rates and socio-economic impacts were determined before the importation of any biocontrol agents. Mikania micrantha was recorded in all 15 lowland provinces in PNG and on all major islands in Fiji. Plants grow about 3.2cm/day in PNG and about 1.9cm/day in Fiji. A socio-economic survey, involving over 370 respondents in over 220 villages from 15 provinces in PNG, found that 78% of respondents considered M. micrantha a serious weed and about 44% had M. micrantha, which they needed to weed at least fortnightly, in over a third of their land. Over 80% of respondents used slashing and/or handpulling as the preferred method of weed control. About 40% of respondents considered that M. micrantha reduced crop yield by more than 30%. In Fiji, 52 respondents from four islands participated in the survey. Over 60% of respondents in Fiji considered M. micrantha a serious weed and 23% had about 30% of their farm lands infested with the weed. Only 15% of respondents needed to weed at least fortnightly, with 56% using slashing and/or hand-pulling as the preferred means of control. Over 65% of respondents estimated that they lost at least 30% of potential crop yield to M. micrantha. Nearly 90% of respondents used M. micrantha as a medicinal plant to treat cuts and wounds. The life history of the rust Puccinia spegazzinii de Toni (Pucciniales: Pucciniaceae), originating from Ecuador, and imported into PNG and Fiji in 2008, was studied. P. spegazzinii is a microcyclic and autoecious rust and has a life cycle of 18-22 days. An efficient culturing and field release method was developed. Since 2008, the rust has been released at over 450 sites in 15 provinces in PNG, establishing at nearly 70 sites in four provinces. From some sites, the rust has spread over 7 km in 12 months. In Fiji, the rust has been released at over 80 sites, on four of the main islands, namely Viti Levu, Vanua Levu, Taveuni and Ovalau, and has established at 20 sites on Viti Levu and Vanua Levu. Plant growth studies and field monitoring in PNG showed that P. spegazzinii can significantly reduce the growth and density of M. micrantha and offers great potential for the control of this weed.
Resumo:
Significant genotypic differences in tolerance of pollen germination and seed set to high temperatures have been shown in sorghum. However, it is unclear whether differences were associated with variation in either the threshold temperature above which reproductive processes are affected, or in the tolerance to increased temperature above that threshold. The objectives of this study were to (a) dissect known differences in heat tolerance for a range of sorghum genotypes into differences in the threshold temperature and tolerance to increased temperatures, (b) determine whether poor seed set under high temperatures can be compensated by increased seed mass, and (c) identify whether genotypic differences in heat tolerance in a controlled environment facility (CEF) can be reproduced in field conditions. Twenty genotypes were grown in a CEF under four day/night temperatures (31.9/21.0 °C, 32.8/21.0 °C, 36.1/21.0 °C, and 38.0/21.0 °C), and a subset of six genotypes was grown in the field under four different temperature regimes around anthesis. The novelty of the findings in this study related to differences in responsiveness to high temperature—genotypic differences in seed set percentage were found for both the threshold temperature and the tolerance to increased maximum temperature above that threshold. Further, the response of seed set to high temperature in the field study was well correlated to that in the CEF (R2 = 0.69), although the slope was significantly less than unity, indicating that heat stress effects may have been diluted under the variable field conditions. Poor seed set was not compensated by increased seed mass in either CEF or field environments. Grain yield was thus closely related to seed set percentage. This result demonstrates the potential for development of a low-cost field screening method to identify high-temperature tolerant varieties that could deliver sustainable yields under future warmer climates.