978 resultados para Fatigue Behavior


Relevância:

60.00% 60.00%

Publicador:

Resumo:

活塞的热疲劳性能对柴油发动机的全寿命至关重要。由于能量有限和可控性差等缺点,现有实验系统均不能满意地进行活塞热负荷模拟实验。为此,提出并建立了一套激光诱发活塞热负荷的实验系统。该系统通过对激光束的空间整形,使之投射到活塞表面后诱发的温度场分布满足特定要求。基于PROFIBUS-DP现场总线技术实现了系统集成和实验过程的全反馈控制。针对活塞的典型热负荷条件,即高周热疲劳和热冲击分别进行实验,以模拟正常工作循环和“启动一停车”等热负荷或转速突变工况。通过设置加热一冷却周期或上限下限温度,可以获得相应的热负荷模拟实验效果。研究结果表明,采用经光束整形的激光进行活塞热负荷模拟实验具有周期短、可控性好等优点。 

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The cyclic deformation behavior Of ultrafine-grained (UFG) Ni samples synthesized by the electrodeposition method was studied. Different from those made by severely plastic deformation, the UFG samples used in this study are characterized by large-angle grain boundaries. Behaviors from nanocrystalline Ni and coarse-grained Ni samples were compared with that Of Ultrafine-grained Ni. With in situ neutron diffraction. unusual evolutions of residual lattice strains as well as cyclic hardening and softening behavior were demonstrated during the cyclic deformation. The microstructural changes investigated by TEM are discussed with respect to the unusual lattice strain and cyclic hardening/softening. (C) 2008 Acta Materialia Inc. Published by Elsevier Ltd. All rights reserved.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

系统研究了纳米晶Ni与粗晶Ni的疲劳行为。通过疲劳实验获得了这2种材料的疲劳应力--寿命曲线,并采用AFM对纳米晶Ni样品表面进行观察以研究其裂纹萌生的微观机制,利用纳米压痕仪对疲劳实验前后样品的力学性能和显微组织变化进行了研究。结果表明,纳米晶Ni具有比粗晶Ni更高的疲劳极限。AFM观察表明纳米晶疲劳后样品表面出现平均尺寸为73 nm的胞状起伏,疲劳后样品的晶粒尺寸没有发生明显改变。压痕硬度结果表明疲劳过程材料的力学性能也未发生明显变化。

Relevância:

60.00% 60.00%

Publicador:

Resumo:

合金材料在超高周疲劳下具有与低周和高周疲劳不同的裂纹萌生和扩展行为以及不同的S-N曲线特征.材料的强度、循环加载的频率、所处的环境等都显著影响超高周疲劳的特性.本文综述了合金材料超高周疲劳行为的基本特征和影响因素的研究进展.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Die laserinduzierte Plasmaspektroskopie (LIPS) ist eine spektrochemische Elementanalyse zur Bestimmung der atomaren Zusammensetzung einer beliebigen Probe. Für die Analyse ist keine spezielle Probenpräparation nötig und kann unter atmosphärischen Bedingungen an Proben in jedem Aggregatzustand durchgeführt werden. Femtosekunden Laserpulse bieten die Vorteile einer präzisen Ablation mit geringem thermischen Schaden sowie einer hohen Reproduzierbarkeit. Damit ist fs-LIPS ein vielversprechendes Werkzeug für die Mikroanalyse technischer Proben, insbesondere zur Untersuchung ihres Ermüdungsverhaltens. Dabei ist interessant, wie sich die initiierten Mikrorisse innerhalb der materialspezifschen Struktur ausbreiten. In der vorliegenden Arbeit sollte daher ein schnelles und einfach zu handhabendes 3D-Rasterabbildungsverfahren zur Untersuchung der Rissausbreitung in TiAl, einer neuen Legierungsklasse, entwickelt werden. Dazu wurde fs-LIPS (30 fs, 785 nm) mit einem modifizierten Mikroskopaufbau (Objektiv: 50x/NA 0.5) kombiniert, welcher eine präzise, automatisierte Probenpositionierung ermöglicht. Spektrochemische Sensitivität und räumliches Auflösungsvermögen wurden in energieabhängigen Einzel- und Multipulsexperimenten untersucht. 10 Laserpulse pro Position mit einer Pulsenergie von je 100 nJ führten in TiAl zum bestmöglichen Kompromiss aus hohem S/N-Verhältnis von 10:1 und kleinen Lochstrukturen mit inneren Durchmessern von 1.4 µm. Die für das Verfahren entscheidende laterale Auflösung, dem minimalen Lochabstand bei konstantem LIPS-Signal, beträgt mit den obigen Parametern 2 µm und ist die bislang höchste bekannte Auflösung einer auf fs-LIPS basierenden Mikro-/Mapping-Analyse im Fernfeld. Fs-LIPS Scans von Teststrukturen sowie Mikrorissen in TiAl demonstrieren eine spektrochemische Sensitivität von 3 %. Scans in Tiefenrichtung erzielen mit denselben Parametern eine axiale Auflösung von 1 µm. Um die spektrochemische Sensitivität von fs-LIPS zu erhöhen und ein besseres Verständnis für die physikalischen Prozesse während der Laserablation zu erhalten, wurde in Pump-Probe-Experimenten untersucht, in wieweit fs-Doppelpulse den laserinduzierten Abtrag sowie die Plasmaemission beeinflussen. Dazu wurden in einem Mach-Zehnder-Interferometer Pulsabstände von 100 fs bis 2 ns realisiert, Gesamtenergie und Intensitätsverhältnis beider Pulse variiert sowie der Einfluss der Materialparameter untersucht. Sowohl das LIPS-Signal als auch die Lochstrukturen zeigen eine Abhängigkeit von der Verzögerungszeit. Diese wurden in vier verschiedene Regimes eingeteilt und den physikalischen Prozessen während der Laserablation zugeordnet: Die Thermalisierung des Elektronensystems für Pulsabstände unter 1 ps, Schmelzprozesse zwischen 1 und 10 ps, der Beginn des Abtrags nach mehreren 10 ps und die Expansion der Plasmawolke nach über 100 ps. Dabei wird das LIPS-Signal effizient verstärkt und bei 800 ps maximal. Die Lochdurchmesser ändern sich als Funktion des Pulsabstands wenig im Vergleich zur Tiefe. Die gesamte Abtragsrate variiert um maximal 50 %, während sich das LIPS-Signal vervielfacht: Für Ti und TiAl typischerweise um das Dreifache, für Al um das 10-fache. Die gemessenen Transienten zeigen eine hohe Reproduzierbarkeit, jedoch kaum eine Energie- bzw. materialspezifische Abhängigkeit. Mit diesen Ergebnissen wurde eine gezielte Optimierung der DP-LIPS-Parameter an Al durchgeführt: Bei einem Pulsabstand von 800 ps und einer Gesamtenergie von 65 nJ (vierfach über der Ablationsschwelle) wurde eine 40-fache Signalerhöhung bei geringerem Rauschen erzielt. Die Lochdurchmesser vergrößerten sich dabei um 44 % auf (650±150) nm, die Lochtiefe um das Doppelte auf (100±15) nm. Damit war es möglich, die spektrochemische Sensitivität von fs-LIPS zu erhöhen und gleichzeitig die hohe räumliche Auflösung aufrecht zu erhalten.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The static and cyclic assays are common to test materials in structures.. For cycling assays to assess the fatigue behavior of the material and thereby obtain the S-N curves and these are used to construct the diagrams of living constant. However, these diagrams, when constructed with small amounts of S-N curves underestimate or overestimate the actual behavior of the composite, there is increasing need for more testing to obtain more accurate results. Therewith, , a way of reducing costs is the statistical analysis of the fatigue behavior. The aim of this research was evaluate the probabilistic fatigue behavior of composite materials. The research was conducted in three parts. The first part consists of associating the equation of probability Weilbull equations commonly used in modeling of composite materials S-N curve, namely the exponential equation and power law and their generalizations. The second part was used the results obtained by the equation which best represents the S-N curves of probability and trained a network to the modular 5% failure. In the third part, we carried out a comparative study of the results obtained using the nonlinear model by parts (PNL) with the results of a modular network architecture (MN) in the analysis of fatigue behavior. For this we used a database of ten materials obtained from the literature to assess the ability of generalization of the modular network as well as its robustness. From the results it was found that the power law of probability generalized probabilistic behavior better represents the fatigue and composites that although the generalization ability of the MN that was not robust training with 5% failure rate, but for values mean the MN showed more accurate results than the PNL model

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Embora a análise no domínio da freqüência do sinal eletromiográfico (EMG) seja empregada na caracterização do processo de fadiga muscular localizada, sua aplicação, especificamente a da freqüência mediana (Fmed), é pouco explorada no âmbito esportivo. O objetivo do presente estudo foi verificar a viabilidade da aplicação do sinal EMG, através de sua análise no domínio da freqüência, como parâmetro para determinação e diferenciação no comportamento da fadiga muscular localizada. Dois grupos de sujeitos, um caracterizado como atletas (n =12) e outro como sedentários (n =12), foram submetidos a análises baseadas em procedimentos executados em três diferentes situações experimentais, todos envolvendo a modalidade de exercício isométrico: i) teste máximo para determinação da contração isométrica voluntária máxima (CIVM); ii) teste de fadiga, sustentado por 35 seg. a 80% da CIVM; iii) teste de recuperação, sustentado por 10 seg. a 80% da CIVM; neste ultimo foi monitorado o comportamento da Fmed nos três primeiros (Fmedi) e três últimos segundos (Fmedf) do sinal EMG no músculo tibial anterior durante o teste de fadiga. Durante os 10 segundos do teste de recuperação foi calculada a Fmed referente a todo o período (Fmedr). parâmetro utilizado no cálculo do índice de recuperação muscular (IRM). Os resultados apontam que a Fmedf apresentou valor menor em relação à Fmedi em ambos os grupos (p < 0,05). Quando comparado com o grupo de sedentários, o grupo de atletas apresentou valores maiores de Fmedi e Fmedf (p < 0,05). O valor médio e desvio-padrão do IRM para o grupo de atletas foram de 62,1% ± 28,7 e, para o grupo de sedentários, de 55,2% ± 27,8 (p > 0,05). Dessa forma, os resultados apresentados neste estudo permitem inferir a viabilidade na aplicação de parâmetros no domínio da freqüência do sinal EMG para a determinação e diferenciação do comportamento da fadiga muscular localizada.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Bi0.92La0.08FeO3 (BLFO) thin films were grown on platine substrates by the soft chemical route. Ferroelectric and dielectric behaviors of BLFO films deposited by spin-coating technique and annealed at 773 K for 2 h in air atmosphere were explained. BLFO thin films obtained presents a rhombohedral structure. The BLFO films present dielectric and ferroelectric behaviors with dielectric permittivity and dielectric loss of approximately 81 and 0.0144 at 1 kHz. The Au/BLFO/Pt capacitor shows a hysteresis loop with remnant polarization of 20.6 mu C/cm(2) and coercive field of 53.88 kV/cm. The polarization switching and the fatigue behavior of the BLFO films were significantly enhanced.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

ASTM F 138 austenitic stainless steel is extensively used as an orthopedic implant material. However, some aspects, such as low strength in the annealed condition and susceptibility to localized corrosion, limit wider use of this kind of steel. Recently, a high-nitrogen austenitic stainless steel, specified in the standard ISO 5832-9, has been indicated as an alternative to ASTM F 138 steel for more severe loading and permanent application inside the human body. In this work, microstructure, mechanical properties, corrosion resistance and fatigue behavior of both steels were determined and compared. ISO 5832-9 steel displayed better mechanical and corrosion behaviors than did ASTM F 138 steel The combination of these features lead ISO steel to enhanced fatigue performance in both neutral and aggressive environments. Analyzed were the role of nitrogen in solid solution, combined with niobium in the Z-phase, and the factors that led to superior ISO 5832-9 properties.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Sabendo-se que a fadiga é uma redução gradual da capacidade de carga do componente pela ruptura lenta e gradual do material. E que este defeito decorre do avanço infinitesimal de microtrincas, que se formam no interior do material, imperceptível a olho nu, como também é notório que a presença dos elementos de liga nos aços, propicia alterações nas propriedades metalurgias e mecânicas no material, aplicado à obra. Por outro lado, ao ser submetido a processamentos dos mais diversos, os mesmos, deformam nas zonas elásticas, plásticas e ao fim rompem-se. Ressaltando-se o objetivo deste estudo, destina se abordar as uniões soldadas, nos estágios em que ficam sujeitas a altas temperaturas e resfriam sem controle, até a temperatura ambiente. Ao fim, são solicitados por carregamentos cíclicos constantes ou alternados. Nesta particularidade, espera-se detectar mudanças estruturais profundas na Zona Termicamente Afetada – ZTA, em razão do superaquecimento sofrido, tanto na proximidade do ponto central da poça de fusão como na região localizada na vizinhança. Como não dispomos de parâmetros suficientes e necessários ao controle destas alterações, propomos analisar a ZTA da junta soldada, com a finalidade de avaliar o comportamento metalúrgico e suas implicações causadas pelas interações gás-metal. Analisar os efeitos resultantes do triangulo formado pelo material base aço AISI/SAE 4340, SAE 1020 chanfrados em V e o eletrodo revestido E-6013. A análise da estrutura será realizada pelas técnicas de ensaio metalográfico usando o método da microscopia óptica – MO o qual é de ampla difusão nas comunicações técnicas e cientificas, através das quais, distinguirão as transformações multifásicas. Transformações estas, distintas pelas transformações das austenitas diretas em martensitas sem passar pelas ferritas e perlitas. Com estas identidades, o metalógrafo pode caracterizar e predizer as reações futuras das estruturas mediante a análise das solicitações, a que possam estar submetidas. Para analisar o comportamento em fadiga dos materiais em questão, adota-se como parâmetro auxiliar, o ensaio do pêndulo de Charpy. Portanto, pelos resultados obtidos, conclui-se que as estruturas são comprometidas por tensões internas em conseqüência fragilizam, mas o procedimento de soldagem pode ser adotado, seguido de recozimento para alivio de tensões, se não fizer trincas.