973 resultados para Farms -- Catalonia -- Osona


Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper investigates the control and operation of doubly-fed induction generator (DFIG) and fixed-speed induction generator (FSIG) based wind farms under unbalanced grid conditions. A DFIG system model suitable for analyzing unbalanced operation is developed, and used to assess the impact of an unbalanced supply on DFIG and FSIG operation. Unbalanced voltage at DFIG and FSIG terminals can cause unequal heating on the stator windings, extra mechanical stresses and output power fluctuations. These problems are particularly serious for the FSIG-based wind farm without a power electronic interface to the grid. To improve the stability of a wind energy system containing both DFIG and FSIG based wind farms during network unbalance, a control strategy of unbalanced voltage compensation by the DFIG systems is proposed. The DFIG system compensation ability and the impact of transmission network impedance are illustrated. The simulation results implemented in Matlab/Simulink show that the proposed DFIG control system improves not only its own performance, but also the stability of the FSIG system with the same grid connection point during network unbalance.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Finding a ‘solution’ for the seemingly intractable problem of unemployment in post-Napoleonic rural England was the Holy Grail for many vestries. Yet, whilst we know much about the depth and consequences of unemployment, parish-driven schemes to set the poor to work have been subjected to remarkably little in the way of systematic study. This paper focuses on one such policy that remains entirely obscure: parish farms, the hiring of pre-existing farms or fields by the parish on which to employ those out of work. Bearing a ‘family resemblance’ to allotments and other land-based attempts to alleviate poverty, parish farms were unique in that they were managed in all regards by the parish and were an employment strategy as opposed to a scheme to supplement the incomes of the poor. Whilst the archive of parish farms is often frustratingly opaque, it is shown that before they were effectively outlawed by the passing of the New Poor Law, many southern parishes, especially in the Weald of Kent and Sussex, adopted the scheme, occasionally with great success.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Porcine circovirus type 2 (PCV2) is now recognized as the essential infectious component of porcine postweaning multisystemic wasting syndrome (PMWS). PMWS was first recognized in high-status, specific pathogen-free pigs in Canada in 1991 and is now an economically important disease that affects the swine industry around the world. Recently, reports of genomic studies on PCV2 viruses indicated that 2 distinctive genogroups of PCV2 exist.(4,10) This report involves the results of a study on the distribution of predominant PCV2 genogroups recovered from samples taken from PMWS-affected and PMWS-nonaffected farms on the island of Ireland over a 9-year period and the results of a study on PCV2 genogroup recovery from fecal samples taken from a farm in Northern Ireland from 2003 to 2005 that was first diagnosed as PMWS positive in August 2005. The results indicate that, although at least 2 distinct genogroups of PCV2 have been circulating on pig farms on the island of Ireland, there does not appear to be a direct relationship between infection with these different genogroups of PCV2 and the development of PMWS.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper examines the ability of the doubly fed induction generator (DFIG) to deliver multiple reactive power objectives during variable wind conditions. The reactive power requirement is decomposed based on various control objectives (e.g. power factor control, voltage control, loss minimisation, and flicker mitigation) defined around different time frames (i.e. seconds, minutes, and hourly), and the control reference is generated by aggregating the individual reactive power requirement for each control strategy. A novel coordinated controller is implemented for the rotor-side converter and the grid-side converter considering their capability curves and illustrating that it can effectively utilise the aggregated DFIG reactive power capability for system performance enhancement. The performance of the multi-objective strategy is examined for a range of wind and network conditions, and it is shown that for the majority of the scenarios, more than 92% of the main control objective can be achieved while introducing the integrated flicker control scheme with the main reactive power control scheme. Therefore, optimal control coordination across the different control strategies can maximise the availability of ancillary services from DFIG-based wind farms without additional dynamic reactive power devices being installed in power networks.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The doubly-fed induction generator (DFIG) now represents the dominant technology in wind turbine design. One consequence of this is limited damping and inertial response during transient grid disturbances. A dasiadecoupledpsila strategy is therefore proposed to operate the DFIG grid-side converter (GSC) as a static synchronous compensator (STATCOM) during a fault, supporting the local voltage, while the DFIG operates as a fixed-speed induction generator (FSIG) providing an inertial response. The modeling aspects of the decoupled control strategy, the selection of protection control settings, the significance of the fault location and operation at sub- and super-synchronous speeds are analyzed in detail. In addition, a case study is developed to validate the proposed strategy under different wind penetrations levels. The simulations show that suitable configuration of the decoupled strategy can be deployed to improve system voltage stability and inertial response for a range of scenarios, especially at high wind penetration. The conclusions are placed in context of the practical limitations of the technology employed and the system conditions.