145 resultados para FLUOROSCOPY


Relevância:

10.00% 10.00%

Publicador:

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND: An animal study was carried out to compare long-term patency rates of coronary anastomoses performed with the GraftConnector versus running suture technique. METHODS: 10 sheep, 45 to 55 kg, underwent off-pump coronary artery bypass grafting (right internal mammary artery to left anterior descending artery). In 5 animals, the anastomosis was performed with a GraftConnector and in 5 animals with 7-0 running suture. Intraoperative fluoroscopy and a fluoroscopic control at 6 months were performed. After 6 months, the animals were sacrificed and the anastomoses were examined histologically. RESULTS: All animals survived at 6 months with 100% anastomosis patency rates in both groups. In the GraftConnector group, the anastomosis diameter at 6 months fluoroscopy was 118% of native left anterior descending artery versus 97% of the control group. Luminal anastomotic width at histology was 1.7 +/- 0.2 mm in the device group versus 1.6 +/- 0.1 mm in the control group. Mean intimal hyperplasia thickness was 0.21 +/- 0.1 mm in the device group versus 0.01 mm in the control group. CONCLUSIONS: The GraftConnector provides a consistent and reproducible coronary artery anastomosis and reduces technical demand and manual dexterity in coronary operations. Long-term results demonstrate that off-pump coronary artery bypass grafting performed with the GraftConnector had the same patency rate and luminal width as those performed with running suture.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The aim of this work is to compare two methods used for determining the proper shielding of computed tomography (CT) rooms while considering recent technological advances in CT scanners. The approaches of the German Institute for Standardisation and the US National Council on Radiation Protection and Measurements were compared and a series of radiation measurements were performed in several CT rooms at the Lausanne University Hospital. The following three-step procedure is proposed for assuring sufficient shielding of rooms hosting new CT units with spiral mode acquisition and various X-ray beam collimation widths: (1) calculate the ambient equivalent dose for a representative average weekly dose length product at the position where shielding is required; (2) from the maximum permissible weekly dose at the location of interest, calculate the transmission factor F that must be taken to ensure proper shielding and (3) convert the transmission factor into a thickness of lead shielding. A similar approach could be adopted to use when designing shielding for fluoroscopy rooms, where the basic quantity would be the dose area product instead of the load of current (milliampere-minute).

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objective: The aim of this study was to investigate the feasibility of transventricular-transseptal approach (TVSA) for extrapleural transcatheter aortic valved stent implantation via a subxyphoidian access. Methods: In five porcine experiments (52.3 +/- 10.9 kg) the right ventricle was exposed via subxyphoidian access. Under the guidance of intracardiac echocardiography (ICE) and fluoroscopy, the transseptal access from right ventricle to left ventricle was created progressively by puncture and dilation with dilators (8F-26F). Valved stents built in-house from commercial tanned pericardium and self-expandable Nitinol stents were loaded into a cartridge. A delivery sheath was then introduced from the right ventricle into the left ventricle and then into the ascending aorta. The cartridge was connected and the valved stent was deployed in the aortic position. Then, the ventricular septal access was sealed with an Amplatzer septal occluder device and the right ventricular access was closed by tying prepared purse-string suture directly. Thirty minutes after the whole procedure, the animals were sacrificed for macroscopic evaluation of the position of valved stent and septal closure device. Result: Procedural success of TVSA was 100% at the first attempt. Mean procedure time was 49 +/- 4 min. Progressive dilatation of the transseptal access resulted in a measurable ventricular septal defect (VSD) after dilator sizes 18F and more. All valved stents were delivered at the target site over the native aortic valve with good acute valve function and no paravalvular leaks. During the procedure, premature beats (5/5) and supraventriclar tachycardias (5/5) were observed, but no atrial-ventricular block (0/5) occurred. Heart rate before (after) was 90 +/- 3 beats min(-1) (100 +/- 2 beats min(-1): p < 0.05), whereas blood pressure was 60 + 1 mm Hg (55 + 2 mm Hg (p < 0.05)). Total blood loss was 280 + 10 ml. The Amplatzer septal occluder devices were fully deployed and the ventricular septal accesses were sealed successfully, without detectable residual shunt. Conclusion: Trans-catheter implantation of aortic valved stent via extrapleural transventricular-transseptal access is technically feasible and has the potential for a simplified procedure under local anaesthesia. (C) 2010 European Association for Cardio-Thoracic Surgery. Published by Elsevier B. V. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In population surveys of the exposure to medical X-rays both the frequency of examinations and the effective dose per examination are required. The use of the Swiss medical tariffication system (TARMED) for establishing the frequency of X-ray medical examinations was explored. The method was tested for radiography examinations performed in 2008 at the Lausanne University Hospital. The annual numbers of radiographies determined from the "TARMED" database are in good agreement with the figures extracted from the local RIS (Radiology Information System). The "TARMED" is a reliable and fast method for establishing the frequency of radiography examination, if we respect the context in which the "TARMED" code is used. In addition, this billing context provides most valuable information on the average number of radiographs per examination as well as the age and sex distributions. Radiographies represent the major part of X-ray examinations and are performed by about 4,000 practices and hospitals in Switzerland. Therefore this method has the potential to drastically simplify the organisation of nationwide surveys. There are still some difficulties to overcome if the method is to be used to assess the frequency of computed tomography or fluoroscopy examinations; procedures that deliver most of the radiation dose to the population. This is due to the poor specificity of "TARMED" codes concerning these modalities. However, the use of CT and fluoroscopy installations is easier to monitor using conventional survey methods since there are fewer centres. Ways to overcome the "TARMED" limitations for these two modalities are still being explored.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Although vertebroplasty was initially a treatment of vertebral haemangioma or metastases, this procedure is now frequent option to the treatment of osteoporotic vertebral fractures. In this review article, we will discuss the indication, the techniques and the follow-up of the vertebroplasty. This is a risky procedure, which should be performed by experimented physicians working with high-resolution fluoroscopic equipments, by biplane fluoroscopy, to reduce the risk and irradiation to the patient. According to the available follow-up studies, there is clear evidence of a strong improvement of quality of life after vertebroplasty by rapid decreasing of back pain at least during the first six months. Other new studies will analyze the long-term follow-up after vertebroplasty.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The development of new medical devices, such as aortic valves, requires numerous preliminary studies on animals and training of personnel on cadavers before the devices can be used in patients. Postmortem circulation, a technique used for postmortem angiography, allows the vascular system to be reperfused in a way similar to that in living persons. This technique is used for postmortem investigations to visualize the human vascular system and to make vascular diagnoses. Specific material for reperfusing a human body was developed recently. Our aim was to investigate whether postmortem circulation that imitates in vivo conditions allows for the testing of medical materials on cadavers. We did this by delivering an aortic valve using minimally invasive methods. Postmortem circulation was established in eight corpses to recreate an environment as close as possible to in vivo conditions. Mobile fluoroscopy and a percutaneous catheterization technique were used to deliver the material to the correct place. Once the valve was implanted, the heart and primary vessels were extracted to confirm its position. Postmortem circulation proved to be essential in several of the cadavers because it helped the clinicians to deliver the material and improve their implantation techniques. Due to the intravascular circulation, sites with substantial arteriosclerotic stenosis could be bypassed, which would have been impossible without perfusion. Although originally developed for postmortem investigations, this reperfusion technique could be useful for testing new medical devices intended for living patients.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Trans-apical aortic valve replacement (AVR) is a new and rapidly growing therapy. However, there are only few training opportunities. The objective of our work is to build an appropriate artificial model of the heart that can replace the use of animals for surgical training in trans-apical AVR procedures. To reduce the necessity for fluoroscopy, we pursued the goal of building a translucent model of the heart that has nature-like dimensions. A simplified 3D model of a human heart with its aortic root was created in silico using the SolidWorks Computer-Aided Design (CAD) program. This heart model was printed using a rapid prototyping system developed by the Fab@Home project and dip-coated two times with dispersion silicone. The translucency of the heart model allows the perception of the deployment area of the valved-stent without using heavy imaging support. The final model was then placed in a human manikin for surgical training on trans-apical AVR procedure. Trans-apical AVR with all the necessary steps (puncture, wiring, catheterization, ballooning etc.) can be realized repeatedly in this setting.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This paper presents a new approach to the treatment of acute fractures in the elbow area, with the support of arthroscopic equipment. There are only a few studies that describe the indications, techniques and results of the arthroscopy-assisted treatment of these pathologies. The authors believe that this tool can be useful for achieving a precise definition of the type of bone-ligament injuries in an elbow joint, thus optimizing treatment and supporting early functional recovery.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Many routes have been described for percutaneous adrenal gland biopsy. They require either a complex non-axial path or a long hydrodissection or even pass through an organ thereby increasing complications. We describe here an approach using an artificially-induced carbon dioxide (CO2) pneumothorax, performed as an outpatient procedure in a 57-year-old woman. Under local anaesthesia, 200 ml of CO2 was injected in the pleural space through a Veress needle under computed tomography fluoroscopy, to clear the lung parenchyma from the biopsy route. Using this technique, transthoracic adrenal biopsy can be performed under simple local anaesthesia as an safely outpatient procedure.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Standard surgical aortic valve replacement with a biological prosthesis remains the treatment of choice for low- and mid-risk elderly patients (traditionally >65 years of age) suffering from severe symptomatic aortic valve stenosis or insufficiency, and for young patients with formal contraindications to long-lasting anticoagulation. Unfortunately, despite the fact that several technical improvements have noticeably improved the resistance of pericardial and bovine bioprostheses to leaflet calcifications and ruptures, the risk of early valve failure with rapid degeneration still exists, especially for patients under haemodialysis and for patients <60 years of age at the time of surgery. Until now, redo open heart surgery under cardiopulmonary bypass and on cardioplegic arrest was the only available therapeutic option in case of bioprosthesis degeneration, but it carried a higher surgical risk when elderly patients with severe concomitant comorbidities were concerned. Since a few years, the advent of new transcatheter aortic valve procedures has opened new horizons in cardiac surgery and, in particular, the possibility of implanting stented valves within the degenerated stented bioprosthesis, the so-called 'valve-in-valve' (VinV) concept, has become a clinical practice in experienced cardiac centres. The VinV procedure represents a minimally invasive approach dedicated to high-risk redo patients, and published preliminary reports have shown a success rate of 100% with absence of significant valvular leaks, acceptable transvalvular gradients and low complication rate. However, this procedure is not riskless and the most important concerns are about the size mismatch and the right positioning within the degenerated bioprosthesis. In this article, we review the limited available literature about VinV procedures, underline important technical details for the positioning and provide guidelines to prevent valve-prosthesis mismatch comparing the three sizes of the only commercially available transapical device, the Edwards Sapien, with the inner diameter of three of the most commonly used stented bioprostheses.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background: Transcatheter aortic valve implantations (TAVI) are indicated in high risk patients requiring aortic valve replacement (AVR). However, CT-scans, coronary angiograms and intraoperative aortographies can induce contrast-related nephro-toxicity with a concrete risk of acute postoperative renal failure, especially in severely diseased patients. To prevent this complication, we routinely perform transapical (TA) TAVI guided by transesophageal echocardiogram and fluoroscopy without angiography. Material and Methods: From November 2008 to December 2009, 31 high-risk patients suffering from severe symptomatic aortic stenosis underwent TA-TAVI in our institution. The preoperative imaging assessment (cardiac CT-scan and coronary angiogram) was performed no less than 10 days before the TA-TAVI in all patients (to recover the renal function) with a low-dose protocol for injected contrast medium (equivalent to the patient's weight for the CT-scan). During the TA-TAVI, the stent-valve positioning was performed without any contrast injection. Results: 32 consecutive stent-valve were successfully positioned in 31 patients (mean age 80.76 8 8.3 years; mean EuroSCORE: 32.2 8 12.9%) through a transapical access (1 patient required 2 valves for valve embolisation). The mean preoperative creatinine and urea blood levels were 102.6 8 67.7 _ g/dl (range 53-339 _ g/dl) and 8.45 8 4.9 mmol/l, respectively. A chronic renal insufficiency affected 12 patients (38.7%) with 1 patient in pre-dialysis. Postoperatively, no patient developed acute myocardial infarction, atrio-ventricular block or acute renal insufficiency (mean creatinine level: 89.7 8 64.55 _ g/dl; urea level: 7.11 8 3.47 mmol/l) and the 30-days mortality was 9.67% (3 patients). Conclusion: Specific preoperative and intraoperative protocols that require lowdoses or absence of contrast medium are useful to preserve the renal function in high risk patients operated for TAVI.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The effective dose delivered to the patient was determined, by modeling, for 257 types of examinations covering the different modalities of diagnostic and interventional radiology. The basic operational dosimetric quantities considered were obtained from the parameters of the examinations on the basis of dosimetric models. These models required a precise characterization of each examination. The operational dosimetric quantities were converted into doses to organs and effective doses using appropriate conversion factors. The determination of the collective effective dose to the Swiss population requires a number of corrections to account for the variability of several parameters: sensitivity of the detection system, age, gender, and build of the patient. The use of various dosimetric models is illustrated in this paper for a limited number of examination types covering the different radiological modalities, for which the established typical effective doses are given. With regard to individual doses, the study indicated that the average effective doses per type of examination can be classified into three levels: (a) the weakly irradiating examinations (less than 0.1 mSv), which represent 78% of the examinations and 4% of the collective dose, (b) the moderately irradiating examinations (between 0.1 mSv and 10 mSv), which represent 21% of the examinations and 72% of the collective dose, (c) the strongly irradiating examinations (more than 10 mSv), which represent 1% of the examinations and 24% of the collective dose.