801 resultados para Expectation-maximization (em) Algorithm
Resumo:
This paper introduces a new unsupervised hyperspectral unmixing method conceived to linear but highly mixed hyperspectral data sets, in which the simplex of minimum volume, usually estimated by the purely geometrically based algorithms, is far way from the true simplex associated with the endmembers. The proposed method, an extension of our previous studies, resorts to the statistical framework. The abundance fraction prior is a mixture of Dirichlet densities, thus automatically enforcing the constraints on the abundance fractions imposed by the acquisition process, namely, nonnegativity and sum-to-one. A cyclic minimization algorithm is developed where the following are observed: 1) The number of Dirichlet modes is inferred based on the minimum description length principle; 2) a generalized expectation maximization algorithm is derived to infer the model parameters; and 3) a sequence of augmented Lagrangian-based optimizations is used to compute the signatures of the endmembers. Experiments on simulated and real data are presented to show the effectiveness of the proposed algorithm in unmixing problems beyond the reach of the geometrically based state-of-the-art competitors.
Resumo:
The development of high spatial resolution airborne and spaceborne sensors has improved the capability of ground-based data collection in the fields of agriculture, geography, geology, mineral identification, detection [2, 3], and classification [4–8]. The signal read by the sensor from a given spatial element of resolution and at a given spectral band is a mixing of components originated by the constituent substances, termed endmembers, located at that element of resolution. This chapter addresses hyperspectral unmixing, which is the decomposition of the pixel spectra into a collection of constituent spectra, or spectral signatures, and their corresponding fractional abundances indicating the proportion of each endmember present in the pixel [9, 10]. Depending on the mixing scales at each pixel, the observed mixture is either linear or nonlinear [11, 12]. The linear mixing model holds when the mixing scale is macroscopic [13]. The nonlinear model holds when the mixing scale is microscopic (i.e., intimate mixtures) [14, 15]. The linear model assumes negligible interaction among distinct endmembers [16, 17]. The nonlinear model assumes that incident solar radiation is scattered by the scene through multiple bounces involving several endmembers [18]. Under the linear mixing model and assuming that the number of endmembers and their spectral signatures are known, hyperspectral unmixing is a linear problem, which can be addressed, for example, under the maximum likelihood setup [19], the constrained least-squares approach [20], the spectral signature matching [21], the spectral angle mapper [22], and the subspace projection methods [20, 23, 24]. Orthogonal subspace projection [23] reduces the data dimensionality, suppresses undesired spectral signatures, and detects the presence of a spectral signature of interest. The basic concept is to project each pixel onto a subspace that is orthogonal to the undesired signatures. As shown in Settle [19], the orthogonal subspace projection technique is equivalent to the maximum likelihood estimator. This projection technique was extended by three unconstrained least-squares approaches [24] (signature space orthogonal projection, oblique subspace projection, target signature space orthogonal projection). Other works using maximum a posteriori probability (MAP) framework [25] and projection pursuit [26, 27] have also been applied to hyperspectral data. In most cases the number of endmembers and their signatures are not known. Independent component analysis (ICA) is an unsupervised source separation process that has been applied with success to blind source separation, to feature extraction, and to unsupervised recognition [28, 29]. ICA consists in finding a linear decomposition of observed data yielding statistically independent components. Given that hyperspectral data are, in given circumstances, linear mixtures, ICA comes to mind as a possible tool to unmix this class of data. In fact, the application of ICA to hyperspectral data has been proposed in reference 30, where endmember signatures are treated as sources and the mixing matrix is composed by the abundance fractions, and in references 9, 25, and 31–38, where sources are the abundance fractions of each endmember. In the first approach, we face two problems: (1) The number of samples are limited to the number of channels and (2) the process of pixel selection, playing the role of mixed sources, is not straightforward. In the second approach, ICA is based on the assumption of mutually independent sources, which is not the case of hyperspectral data, since the sum of the abundance fractions is constant, implying dependence among abundances. This dependence compromises ICA applicability to hyperspectral images. In addition, hyperspectral data are immersed in noise, which degrades the ICA performance. IFA [39] was introduced as a method for recovering independent hidden sources from their observed noisy mixtures. IFA implements two steps. First, source densities and noise covariance are estimated from the observed data by maximum likelihood. Second, sources are reconstructed by an optimal nonlinear estimator. Although IFA is a well-suited technique to unmix independent sources under noisy observations, the dependence among abundance fractions in hyperspectral imagery compromises, as in the ICA case, the IFA performance. Considering the linear mixing model, hyperspectral observations are in a simplex whose vertices correspond to the endmembers. Several approaches [40–43] have exploited this geometric feature of hyperspectral mixtures [42]. Minimum volume transform (MVT) algorithm [43] determines the simplex of minimum volume containing the data. The MVT-type approaches are complex from the computational point of view. Usually, these algorithms first find the convex hull defined by the observed data and then fit a minimum volume simplex to it. Aiming at a lower computational complexity, some algorithms such as the vertex component analysis (VCA) [44], the pixel purity index (PPI) [42], and the N-FINDR [45] still find the minimum volume simplex containing the data cloud, but they assume the presence in the data of at least one pure pixel of each endmember. This is a strong requisite that may not hold in some data sets. In any case, these algorithms find the set of most pure pixels in the data. Hyperspectral sensors collects spatial images over many narrow contiguous bands, yielding large amounts of data. For this reason, very often, the processing of hyperspectral data, included unmixing, is preceded by a dimensionality reduction step to reduce computational complexity and to improve the signal-to-noise ratio (SNR). Principal component analysis (PCA) [46], maximum noise fraction (MNF) [47], and singular value decomposition (SVD) [48] are three well-known projection techniques widely used in remote sensing in general and in unmixing in particular. The newly introduced method [49] exploits the structure of hyperspectral mixtures, namely the fact that spectral vectors are nonnegative. The computational complexity associated with these techniques is an obstacle to real-time implementations. To overcome this problem, band selection [50] and non-statistical [51] algorithms have been introduced. This chapter addresses hyperspectral data source dependence and its impact on ICA and IFA performances. The study consider simulated and real data and is based on mutual information minimization. Hyperspectral observations are described by a generative model. This model takes into account the degradation mechanisms normally found in hyperspectral applications—namely, signature variability [52–54], abundance constraints, topography modulation, and system noise. The computation of mutual information is based on fitting mixtures of Gaussians (MOG) to data. The MOG parameters (number of components, means, covariances, and weights) are inferred using the minimum description length (MDL) based algorithm [55]. We study the behavior of the mutual information as a function of the unmixing matrix. The conclusion is that the unmixing matrix minimizing the mutual information might be very far from the true one. Nevertheless, some abundance fractions might be well separated, mainly in the presence of strong signature variability, a large number of endmembers, and high SNR. We end this chapter by sketching a new methodology to blindly unmix hyperspectral data, where abundance fractions are modeled as a mixture of Dirichlet sources. This model enforces positivity and constant sum sources (full additivity) constraints. The mixing matrix is inferred by an expectation-maximization (EM)-type algorithm. This approach is in the vein of references 39 and 56, replacing independent sources represented by MOG with mixture of Dirichlet sources. Compared with the geometric-based approaches, the advantage of this model is that there is no need to have pure pixels in the observations. The chapter is organized as follows. Section 6.2 presents a spectral radiance model and formulates the spectral unmixing as a linear problem accounting for abundance constraints, signature variability, topography modulation, and system noise. Section 6.3 presents a brief resume of ICA and IFA algorithms. Section 6.4 illustrates the performance of IFA and of some well-known ICA algorithms with experimental data. Section 6.5 studies the ICA and IFA limitations in unmixing hyperspectral data. Section 6.6 presents results of ICA based on real data. Section 6.7 describes the new blind unmixing scheme and some illustrative examples. Section 6.8 concludes with some remarks.
Resumo:
This paper introduces a new hyperspectral unmixing method called Dependent Component Analysis (DECA). This method decomposes a hyperspectral image into a collection of reflectance (or radiance) spectra of the materials present in the scene (endmember signatures) and the corresponding abundance fractions at each pixel. DECA models the abundance fractions as mixtures of Dirichlet densities, thus enforcing the constraints on abundance fractions imposed by the acquisition process, namely non-negativity and constant sum. The mixing matrix is inferred by a generalized expectation-maximization (GEM) type algorithm. This method overcomes the limitations of unmixing methods based on Independent Component Analysis (ICA) and on geometrical based approaches. DECA performance is illustrated using simulated and real data.
Resumo:
Hyperspectral unmixing methods aim at the decomposition of a hyperspectral image into a collection endmember signatures, i.e., the radiance or reflectance of the materials present in the scene, and the correspondent abundance fractions at each pixel in the image. This paper introduces a new unmixing method termed dependent component analysis (DECA). This method is blind and fully automatic and it overcomes the limitations of unmixing methods based on Independent Component Analysis (ICA) and on geometrical based approaches. DECA is based on the linear mixture model, i.e., each pixel is a linear mixture of the endmembers signatures weighted by the correspondent abundance fractions. These abundances are modeled as mixtures of Dirichlet densities, thus enforcing the non-negativity and constant sum constraints, imposed by the acquisition process. The endmembers signatures are inferred by a generalized expectation-maximization (GEM) type algorithm. The paper illustrates the effectiveness of DECA on synthetic and real hyperspectral images.
Resumo:
RESUMO: Introdução: A espondilite anquilosante (EA) é uma doença inflamatória crónica caracterizada pela inflamação das articulações sacroilíacas e da coluna. A anquilose progressiva motiva uma deterioração gradual da função física e da qualidade de vida. O diagnóstico e o tratamento precoces podem contribuir para um melhor prognóstico. Neste contexto, a identificação de biomarcadores, assume-se como sendo muito útil para a prática clínica e representa hoje um grande desafio para a comunidade científica. Objetivos: Este estudo teve como objetivos: 1 - caracterizar a EA em Portugal; 2 - investigar possíveis associações entre genes, MHC e não-MHC, com a suscetibilidade e as características fenotípicas da EA; 3 - identificar genes candidatos associados a EA através da tecnologia de microarray. Material e Métodos: Foram recrutados doentes com EA, de acordo com os critérios modificados de Nova Iorque, nas consultas de Reumatologia dos diferentes hospitais participantes. Colecionaram-se dados demográficos, clínicos e radiológicos e colhidas amostras de sangue periférico. Selecionaram-se de forma aleatória, doentes HLA-B27 positivos, os quais foram tipados em termos de HLA classe I e II por PCR-rSSOP. Os haplótipos HLA estendidos foram estimados pelo algoritmo Expectation Maximization com recurso ao software Arlequin v3.11. As variantes alélicas dos genes IL23R, ERAP1 e ANKH foram estudadas através de ensaios de discriminação alélica TaqMan. A análise de associação foi realizada utilizando testes da Cochrane-Armitage e de regressão linear, tal como implementado pelo PLINK, para variáveis qualitativas e quantitativas, respetivamente. O estudo de expressão génica foi realizado por Illumina HT-12 Whole-Genome Expression BeadChips. Os genes candidatos foram validados usando qPCR-based TaqMan Low Density Arrays (TLDAs). Resultados: Foram incluídos 369 doentes (62,3% do sexo masculino, com idade média de 45,4 ± 13,2 anos, duração média da doença de 11,4 ± 10,5 anos). No momento da avaliação, 49,9% tinham doença axial, 2,4% periférica, 40,9% mista e 7,1% entesopática. A uveíte anterior aguda (33,6%) foi a manifestação extra-articular mais comum. Foram positivos para o HLA-B27, 80,3% dos doentes. Os haplótipo A*02/B*27/Cw*02/DRB1*01/DQB1*05 parece conferir suscetibilidade para a EA, e o A*02/B*27/Cw*01/DRB1*08/DQB1*04 parece conferir proteção em termos de atividade, repercussão funcional e radiológica da doença. Três variantes (2 para IL23R e 1 para ERAP1) mostraram significativa associação com a doença, confirmando a associação destes genes com a EA na população Portuguesa. O mesmo não se verificou com as variantes estudadas do ANKH. Não se verificou associação entre as variantes génicas não-MHC e as manifestações clínicas da EA. Foi identificado um perfil de expressão génica para a EA, tendo sido validados catorze genes - alguns têm um papel bem documentado em termos de inflamação, outros no metabolismo da cartilagem e do osso. Conclusões: Foi estabelecido um perfil demográfico e clínico dos doentes com EA em Portugal. A identificação de variantes génicas e de um perfil de expressão contribuem para uma melhor compreensão da sua fisiopatologia e podem ser úteis para estabelecer modelos com relevância em termos de diagnóstico, prognóstico e orientação terapêutica dos doentes. -----------ABSTRACT: Background: Ankylosing Spondylitis (AS) is a chronic inflammatory disorder characterized by inflammation in the spine and sacroiliac joints leading to progressive joint ankylosis and in progressive deterioration of physical function and quality of life. An early diagnosis and early therapy may contribute to a better prognosis. The identification of biomarkers would be helpful and represents a great challenge for the scientific community. Objectives: The present study had the following aims: 1- to characterize the pattern of AS in Portuguese patients; 2- to investigate MHC and non-MHC gene associations with susceptibility and phenotypic features of AS and; 3- to identify candidate genes associated with AS by means of whole-genome microarray. Material and Methods: AS was defined in accordance to the modified New York criteria and AS cases were recruited from hospital outcares patient clinics. Demographic and clinical data were recorded and blood samples collected. A random group of HLA-B27 positive patients and controls were selected and typed for HLA class I and II by PCR-rSSOP. The extended HLA haplotypes were estimated by Expectation Maximization Algorithm using Arlequin v3.11 software. Genotyping of IL23R, ERAP1 and ANKH allelic variants was carried out with TaqMan allelic discrimination assays. Association analysis was performed using the Cochrane-Armitage and linear regression tests as implemented in PLINK, for dichotomous and quantitative variables, respectively. Gene expression profile was carried out using Illumina HT-12 Whole-Genome Expression BeadChips and candidate genes were validated using qPCR-based TaqMan Low Density Arrays (TLDAs). Results: A total of 369 patients (62.3% male; mean age 45.4±13.2 years; mean disease duration 11.4±10.5 years), were included. Regarding clinical disease pattern, at the time of assessment, 49.9% had axial disease, 2.4% peripheral disease, 40.9% mixed disease and 7.1% isolated enthesopathic disease. Acute anterior uveitis (33.6%) was the most common extra-articular manifestation. 80.3% of AS patients were HLA-B27 positive. The haplotype A*02/B*27/Cw*02/DRB1*01/DQB1*05 seems to confer susceptibility to AS, whereas A*02/B*27/Cw*01/DRB1*08/DQB1*04 seems to provide protection in terms of disease activity, functional and radiological repercussion. Three markers (two for IL23R and one for ERAP1) showed significant single-locus disease associations. Association of these genes with AS in the Portuguese population was confirmed, whereas ANKH markers studied did not show an association with AS. No association was seen between non-MHC genes and clinical manifestations of AS. A gene expression signature for AS was established; among the fourteen validated genes, a number of them have a well-documented inflammatory role or in modulation of cartilage and bone metabolism. Conclusions: A demographic and clinical profile of patients with AS in Portugal was established. Identification of genetic variants of target genes as well as gene expression signatures could provide a better understanding of AS pathophysiology and could be useful to establish models with relevance in terms of susceptibility, prognosis, and potential therapeutic guidance.
Resumo:
Coronary artery calcification (CAC) is quantified based on a computed tomography (CT) scan image. A calcified region is identified. Modified expectation maximization (MEM) of a statistical model for the calcified and background material is used to estimate the partial calcium content of the voxels. The algorithm limits the region over which MEM is performed. By using MEM, the statistical properties of the model are iteratively updated based on the calculated resultant calcium distribution from the previous iteration. The estimated statistical properties are used to generate a map of the partial calcium content in the calcified region. The volume of calcium in the calcified region is determined based on the map. The experimental results on a cardiac phantom, scanned 90 times using 15 different protocols, demonstrate that the proposed method is less sensitive to partial volume effect and noise, with average error of 9.5% (standard deviation (SD) of 5-7mm(3)) compared with 67% (SD of 3-20mm(3)) for conventional techniques. The high reproducibility of the proposed method for 35 patients, scanned twice using the same protocol at a minimum interval of 10 min, shows that the method provides 2-3 times lower interscan variation than conventional techniques.
Resumo:
Given the very large amount of data obtained everyday through population surveys, much of the new research again could use this information instead of collecting new samples. Unfortunately, relevant data are often disseminated into different files obtained through different sampling designs. Data fusion is a set of methods used to combine information from different sources into a single dataset. In this article, we are interested in a specific problem: the fusion of two data files, one of which being quite small. We propose a model-based procedure combining a logistic regression with an Expectation-Maximization algorithm. Results show that despite the lack of data, this procedure can perform better than standard matching procedures.
Resumo:
BACKGROUND: The clinical course of HIV-1 infection is highly variable among individuals, at least in part as a result of genetic polymorphisms in the host. Toll-like receptors (TLRs) have a key role in innate immunity and mutations in the genes encoding these receptors have been associated with increased or decreased susceptibility to infections. OBJECTIVES: To determine whether single-nucleotide polymorphisms (SNPs) in TLR2-4 and TLR7-9 influenced the natural course of HIV-1 infection. METHODS: Twenty-eight SNPs in TLRs were analysed in HAART-naive HIV-positive patients from the Swiss HIV Cohort Study. The SNPs were detected using Sequenom technology. Haplotypes were inferred using an expectation-maximization algorithm. The CD4 T cell decline was calculated using a least-squares regression. Patients with a rapid CD4 cell decline, less than the 15th percentile, were defined as rapid progressors. The risk of rapid progression associated with SNPs was estimated using a logistic regression model. Other candidate risk factors included age, sex and risk groups (heterosexual, homosexual and intravenous drug use). RESULTS: Two SNPs in TLR9 (1635A/G and +1174G/A) in linkage disequilibrium were associated with the rapid progressor phenotype: for 1635A/G, odds ratio (OR), 3.9 [95% confidence interval (CI),1.7-9.2] for GA versus AA and OR, 4.7 (95% CI,1.9-12.0) for GG versus AA (P = 0.0008). CONCLUSION: Rapid progression of HIV-1 infection was associated with TLR9 polymorphisms. Because of its potential implications for intervention strategies and vaccine developments, additional epidemiological and experimental studies are needed to confirm this association.
Resumo:
Impressive developments in X-ray imaging are associated with X-ray phase contrast computed tomography based on grating interferometry, a technique that provides increased contrast compared with conventional absorption-based imaging. A new "single-step" method capable of separating phase information from other contributions has been recently proposed. This approach not only simplifies data-acquisition procedures, but, compared with the existing phase step approach, significantly reduces the dose delivered to a sample. However, the image reconstruction procedure is more demanding than for traditional methods and new algorithms have to be developed to take advantage of the "single-step" method. In the work discussed in this paper, a fast iterative image reconstruction method named OSEM (ordered subsets expectation maximization) was applied to experimental data to evaluate its performance and range of applicability. The OSEM algorithm with different subsets was also characterized by comparison of reconstruction image quality and convergence speed. Computer simulations and experimental results confirm the reliability of this new algorithm for phase-contrast computed tomography applications. Compared with the traditional filtered back projection algorithm, in particular in the presence of a noisy acquisition, it furnishes better images at a higher spatial resolution and with lower noise. We emphasize that the method is highly compatible with future X-ray phase contrast imaging clinical applications.
Resumo:
The analysis of rockfall characteristics and spatial distribution is fundamental to understand and model the main factors that predispose to failure. In our study we analysed LiDAR point clouds aiming to: (1) detect and characterise single rockfalls; (2) investigate their spatial distribution. To this end, different cluster algorithms were applied: 1a) Nearest Neighbour Clutter Removal (NNCR) in combination with the Expectation?Maximization (EM) in order to separate feature points from clutter; 1b) a density based algorithm (DBSCAN) was applied to isolate the single clusters (i.e. the rockfall events); 2) finally we computed the Ripley's K-function to investigate the global spatial pattern of the extracted rockfalls. The method allowed proper identification and characterization of more than 600 rockfalls occurred on a cliff located in Puigcercos (Catalonia, Spain) during a time span of six months. The spatial distribution of these events proved that rockfall were clustered distributed at a welldefined distance-range. Computations were carried out using R free software for statistical computing and graphics. The understanding of the spatial distribution of precursory rockfalls may shed light on the forecasting of future failures.
Resumo:
Our objective is to develop a diffusion Monte Carlo (DMC) algorithm to estimate the exact expectation values, ($o|^|^o), of multiplicative operators, such as polarizabilities and high-order hyperpolarizabilities, for isolated atoms and molecules. The existing forward-walking pure diffusion Monte Carlo (FW-PDMC) algorithm which attempts this has a serious bias. On the other hand, the DMC algorithm with minimal stochastic reconfiguration provides unbiased estimates of the energies, but the expectation values ($o|^|^) are contaminated by ^, an user specified, approximate wave function, when A does not commute with the Hamiltonian. We modified the latter algorithm to obtain the exact expectation values for these operators, while at the same time eliminating the bias. To compare the efficiency of FW-PDMC and the modified DMC algorithms we calculated simple properties of the H atom, such as various functions of coordinates and polarizabilities. Using three non-exact wave functions, one of moderate quality and the others very crude, in each case the results are within statistical error of the exact values.
Resumo:
Le développement d’un médicament est non seulement complexe mais les retours sur investissment ne sont pas toujours ceux voulus ou anticipés. Plusieurs médicaments échouent encore en Phase III même avec les progrès technologiques réalisés au niveau de plusieurs aspects du développement du médicament. Ceci se traduit en un nombre décroissant de médicaments qui sont commercialisés. Il faut donc améliorer le processus traditionnel de développement des médicaments afin de faciliter la disponibilité de nouveaux produits aux patients qui en ont besoin. Le but de cette recherche était d’explorer et de proposer des changements au processus de développement du médicament en utilisant les principes de la modélisation avancée et des simulations d’essais cliniques. Dans le premier volet de cette recherche, de nouveaux algorithmes disponibles dans le logiciel ADAPT 5® ont été comparés avec d’autres algorithmes déjà disponibles afin de déterminer leurs avantages et leurs faiblesses. Les deux nouveaux algorithmes vérifiés sont l’itératif à deux étapes (ITS) et le maximum de vraisemblance avec maximisation de l’espérance (MLEM). Les résultats de nos recherche ont démontré que MLEM était supérieur à ITS. La méthode MLEM était comparable à l’algorithme d’estimation conditionnelle de premier ordre (FOCE) disponible dans le logiciel NONMEM® avec moins de problèmes de rétrécissement pour les estimés de variances. Donc, ces nouveaux algorithmes ont été utilisés pour la recherche présentée dans cette thèse. Durant le processus de développement d’un médicament, afin que les paramètres pharmacocinétiques calculés de façon noncompartimentale soient adéquats, il faut que la demi-vie terminale soit bien établie. Des études pharmacocinétiques bien conçues et bien analysées sont essentielles durant le développement des médicaments surtout pour les soumissions de produits génériques et supergénériques (une formulation dont l'ingrédient actif est le même que celui du médicament de marque, mais dont le profil de libération du médicament est différent de celui-ci) car elles sont souvent les seules études essentielles nécessaires afin de décider si un produit peut être commercialisé ou non. Donc, le deuxième volet de la recherche visait à évaluer si les paramètres calculer d’une demi-vie obtenue à partir d'une durée d'échantillonnage réputée trop courte pour un individu pouvaient avoir une incidence sur les conclusions d’une étude de bioéquivalence et s’ils devaient être soustraits d’analyses statistiques. Les résultats ont démontré que les paramètres calculer d’une demi-vie obtenue à partir d'une durée d'échantillonnage réputée trop courte influençaient de façon négative les résultats si ceux-ci étaient maintenus dans l’analyse de variance. Donc, le paramètre de surface sous la courbe à l’infini pour ces sujets devrait être enlevé de l’analyse statistique et des directives à cet effet sont nécessaires a priori. Les études finales de pharmacocinétique nécessaires dans le cadre du développement d’un médicament devraient donc suivre cette recommandation afin que les bonnes décisions soient prises sur un produit. Ces informations ont été utilisées dans le cadre des simulations d’essais cliniques qui ont été réalisées durant la recherche présentée dans cette thèse afin de s’assurer d’obtenir les conclusions les plus probables. Dans le dernier volet de cette thèse, des simulations d’essais cliniques ont amélioré le processus du développement clinique d’un médicament. Les résultats d’une étude clinique pilote pour un supergénérique en voie de développement semblaient très encourageants. Cependant, certaines questions ont été soulevées par rapport aux résultats et il fallait déterminer si le produit test et référence seraient équivalents lors des études finales entreprises à jeun et en mangeant, et ce, après une dose unique et des doses répétées. Des simulations d’essais cliniques ont été entreprises pour résoudre certaines questions soulevées par l’étude pilote et ces simulations suggéraient que la nouvelle formulation ne rencontrerait pas les critères d’équivalence lors des études finales. Ces simulations ont aussi aidé à déterminer quelles modifications à la nouvelle formulation étaient nécessaires afin d’améliorer les chances de rencontrer les critères d’équivalence. Cette recherche a apporté des solutions afin d’améliorer différents aspects du processus du développement d’un médicament. Particulièrement, les simulations d’essais cliniques ont réduit le nombre d’études nécessaires pour le développement du supergénérique, le nombre de sujets exposés inutilement au médicament, et les coûts de développement. Enfin, elles nous ont permis d’établir de nouveaux critères d’exclusion pour des analyses statistiques de bioéquivalence. La recherche présentée dans cette thèse est de suggérer des améliorations au processus du développement d’un médicament en évaluant de nouveaux algorithmes pour des analyses compartimentales, en établissant des critères d’exclusion de paramètres pharmacocinétiques (PK) pour certaines analyses et en démontrant comment les simulations d’essais cliniques sont utiles.
Resumo:
Nous y introduisons une nouvelle classe de distributions bivariées de type Marshall-Olkin, la distribution Erlang bivariée. La transformée de Laplace, les moments et les densités conditionnelles y sont obtenus. Les applications potentielles en assurance-vie et en finance sont prises en considération. Les estimateurs du maximum de vraisemblance des paramètres sont calculés par l'algorithme Espérance-Maximisation. Ensuite, notre projet de recherche est consacré à l'étude des processus de risque multivariés, qui peuvent être utiles dans l'étude des problèmes de la ruine des compagnies d'assurance avec des classes dépendantes. Nous appliquons les résultats de la théorie des processus de Markov déterministes par morceaux afin d'obtenir les martingales exponentielles, nécessaires pour établir des bornes supérieures calculables pour la probabilité de ruine, dont les expressions sont intraitables.
Resumo:
Le modèle GARCH à changement de régimes est le fondement de cette thèse. Ce modèle offre de riches dynamiques pour modéliser les données financières en combinant une structure GARCH avec des paramètres qui varient dans le temps. Cette flexibilité donne malheureusement lieu à un problème de path dependence, qui a empêché l'estimation du modèle par le maximum de vraisemblance depuis son introduction, il y a déjà près de 20 ans. La première moitié de cette thèse procure une solution à ce problème en développant deux méthodologies permettant de calculer l'estimateur du maximum de vraisemblance du modèle GARCH à changement de régimes. La première technique d'estimation proposée est basée sur l'algorithme Monte Carlo EM et sur l'échantillonnage préférentiel, tandis que la deuxième consiste en la généralisation des approximations du modèle introduites dans les deux dernières décennies, connues sous le nom de collapsing procedures. Cette généralisation permet d'établir un lien méthodologique entre ces approximations et le filtre particulaire. La découverte de cette relation est importante, car elle permet de justifier la validité de l'approche dite par collapsing pour estimer le modèle GARCH à changement de régimes. La deuxième moitié de cette thèse tire sa motivation de la crise financière de la fin des années 2000 pendant laquelle une mauvaise évaluation des risques au sein de plusieurs compagnies financières a entraîné de nombreux échecs institutionnels. À l'aide d'un large éventail de 78 modèles économétriques, dont plusieurs généralisations du modèle GARCH à changement de régimes, il est démontré que le risque de modèle joue un rôle très important dans l'évaluation et la gestion du risque d'investissement à long terme dans le cadre des fonds distincts. Bien que la littérature financière a dévoué beaucoup de recherche pour faire progresser les modèles économétriques dans le but d'améliorer la tarification et la couverture des produits financiers, les approches permettant de mesurer l'efficacité d'une stratégie de couverture dynamique ont peu évolué. Cette thèse offre une contribution méthodologique dans ce domaine en proposant un cadre statistique, basé sur la régression, permettant de mieux mesurer cette efficacité.
Resumo:
La tomographie d’émission par positrons (TEP) est une modalité d’imagerie moléculaire utilisant des radiotraceurs marqués par des isotopes émetteurs de positrons permettant de quantifier et de sonder des processus biologiques et physiologiques. Cette modalité est surtout utilisée actuellement en oncologie, mais elle est aussi utilisée de plus en plus en cardiologie, en neurologie et en pharmacologie. En fait, c’est une modalité qui est intrinsèquement capable d’offrir avec une meilleure sensibilité des informations fonctionnelles sur le métabolisme cellulaire. Les limites de cette modalité sont surtout la faible résolution spatiale et le manque d’exactitude de la quantification. Par ailleurs, afin de dépasser ces limites qui constituent un obstacle pour élargir le champ des applications cliniques de la TEP, les nouveaux systèmes d’acquisition sont équipés d’un grand nombre de petits détecteurs ayant des meilleures performances de détection. La reconstruction de l’image se fait en utilisant les algorithmes stochastiques itératifs mieux adaptés aux acquisitions à faibles statistiques. De ce fait, le temps de reconstruction est devenu trop long pour une utilisation en milieu clinique. Ainsi, pour réduire ce temps, on les données d’acquisition sont compressées et des versions accélérées d’algorithmes stochastiques itératifs qui sont généralement moins exactes sont utilisées. Les performances améliorées par l’augmentation de nombre des détecteurs sont donc limitées par les contraintes de temps de calcul. Afin de sortir de cette boucle et permettre l’utilisation des algorithmes de reconstruction robustes, de nombreux travaux ont été effectués pour accélérer ces algorithmes sur les dispositifs GPU (Graphics Processing Units) de calcul haute performance. Dans ce travail, nous avons rejoint cet effort de la communauté scientifique pour développer et introduire en clinique l’utilisation des algorithmes de reconstruction puissants qui améliorent la résolution spatiale et l’exactitude de la quantification en TEP. Nous avons d’abord travaillé sur le développement des stratégies pour accélérer sur les dispositifs GPU la reconstruction des images TEP à partir des données d’acquisition en mode liste. En fait, le mode liste offre de nombreux avantages par rapport à la reconstruction à partir des sinogrammes, entre autres : il permet d’implanter facilement et avec précision la correction du mouvement et le temps de vol (TOF : Time-Of Flight) pour améliorer l’exactitude de la quantification. Il permet aussi d’utiliser les fonctions de bases spatio-temporelles pour effectuer la reconstruction 4D afin d’estimer les paramètres cinétiques des métabolismes avec exactitude. Cependant, d’une part, l’utilisation de ce mode est très limitée en clinique, et d’autre part, il est surtout utilisé pour estimer la valeur normalisée de captation SUV qui est une grandeur semi-quantitative limitant le caractère fonctionnel de la TEP. Nos contributions sont les suivantes : - Le développement d’une nouvelle stratégie visant à accélérer sur les dispositifs GPU l’algorithme 3D LM-OSEM (List Mode Ordered-Subset Expectation-Maximization), y compris le calcul de la matrice de sensibilité intégrant les facteurs d’atténuation du patient et les coefficients de normalisation des détecteurs. Le temps de calcul obtenu est non seulement compatible avec une utilisation clinique des algorithmes 3D LM-OSEM, mais il permet également d’envisager des reconstructions rapides pour les applications TEP avancées telles que les études dynamiques en temps réel et des reconstructions d’images paramétriques à partir des données d’acquisitions directement. - Le développement et l’implantation sur GPU de l’approche Multigrilles/Multitrames pour accélérer l’algorithme LMEM (List-Mode Expectation-Maximization). L’objectif est de développer une nouvelle stratégie pour accélérer l’algorithme de référence LMEM qui est un algorithme convergent et puissant, mais qui a l’inconvénient de converger très lentement. Les résultats obtenus permettent d’entrevoir des reconstructions en temps quasi-réel que ce soit pour les examens utilisant un grand nombre de données d’acquisition aussi bien que pour les acquisitions dynamiques synchronisées. Par ailleurs, en clinique, la quantification est souvent faite à partir de données d’acquisition en sinogrammes généralement compressés. Mais des travaux antérieurs ont montré que cette approche pour accélérer la reconstruction diminue l’exactitude de la quantification et dégrade la résolution spatiale. Pour cette raison, nous avons parallélisé et implémenté sur GPU l’algorithme AW-LOR-OSEM (Attenuation-Weighted Line-of-Response-OSEM) ; une version de l’algorithme 3D OSEM qui effectue la reconstruction à partir de sinogrammes sans compression de données en intégrant les corrections de l’atténuation et de la normalisation dans les matrices de sensibilité. Nous avons comparé deux approches d’implantation : dans la première, la matrice système (MS) est calculée en temps réel au cours de la reconstruction, tandis que la seconde implantation utilise une MS pré- calculée avec une meilleure exactitude. Les résultats montrent que la première implantation offre une efficacité de calcul environ deux fois meilleure que celle obtenue dans la deuxième implantation. Les temps de reconstruction rapportés sont compatibles avec une utilisation clinique de ces deux stratégies.