930 resultados para Energy sustainability
Resumo:
The electrochemistry of nicotinamide adenine dinucleotide (NADH) in its reduced form was examined in two room-temperature ionic liquids (RTILs): 1-ethyl-3-methylimidazolium bis-(trifluoromethylsulfonyl)imide ([C(2)mim][NTf2]) and 1-butyl-3-methylimidazolium hexafluorophos-phate ([C(4)mim][PF6]). NADH oxidation has previously been studied in aqueous solution where it follows the pathway: one-electron oxidation to the NADH(center dot+) radical cation, deprotonation to produce the neutral NAD(center dot) radical, then oxidation to the NAD(+) cation. The electrochemistry of NADH was examined in [C(2)mim][NTf2] and [C(4)mim][PF6] at the bare Pt electrode (10 mu m diameter): In [C(2)mim][NTf2], no oxidation was observed; in [C(4)mim][PF6], an oxidative signal was observed, which likely followed the pathway described above, where upon formation of the NADH(center dot+) radical cation, the [PF6](-) anion (unlike the [NTf2](-) anion) reacts with the proton to form HPF6, which decomposes. This demonstrates the tunability of RTILs, whereby the choice of one anion in an RTIL over another can promote a reaction. Poly(vinylferrocene) (PVF) was studied as a mediator for the NADH detection in both RTILs to attempt to lower the potential of NADH detection. The Pt electrode was modified with PVF, and the oxidation of PVF to PVF+ was observed in [C(2)mim][NTf2] and [C(4)mim][PF6], but no mediation of the NADH oxidation was observed.
Resumo:
The coupled heat, air and moisture transfer between building envelopes and indoor air is complicated, and has a significant influence on the indoor environment and the energy performance of buildings. In the paper, a model for predicting coupled multi-zone hygrothermal-airflow transfer is presented. Both heat and moisture transfer in the building envelope and multi-zone indoor airflow are simultaneously considered; their interactions are modeled. The coupled system model is implemented into Matlab–Simulink, and is validated by using a series of testing tools and experiments. The new program is applied to investigate the moisture transfer effect on indoor air humidity and building energy consumption in different climates (hot-humid, temperate and hot-dry climates). The results show that not accounting for hygrothermal effects in modeling will result in overestimation of energy costs for hot and humid climate situations and possible over sizing of plant leading to inefficient operation.
Resumo:
This paper proposes a decoupled fault ride-through strategy for a doubly fed induction generator (DFIG) to enhance network stability during grid disturbances. The decoupled operation proposes that a DFIG operates as an induction generator (IG) with the converter unit acting as a reactive power source during a fault condition. The transition power characteristics of the DFIG have been analyzed to derive the capability of the proposed strategy under various system conditions. The optimal crowbar resistance is obtained to exploit the maximum power capability from the DFIG during decoupled operation. The methods have been established to ensure proper coordination between the IG mode and reactive power compensation from the grid-side converter during decoupled operation. The viability and benefits of the proposed strategy are demonstrated using different test network structures and different wind penetration levels. Control performance has been benchmarked against existing grid code standards and commercial wind generator systems, based on the optimal network support required (i.e., voltage or frequency) by the system operator from a wind farm installed at a particular location.
Resumo:
The global increase in the penetration of renewable energy is pushing electrical power systems into uncharted territory, especially in terms of transient and dynamic stability. In particular, the greater penetration of wind generation in European power networks is, at times, displacing a significant capacity of conventional synchronous generation with fixed-speed induction generation and now more commonly, doubly fed induction generators. The impact of such changes in the generation mix requires careful monitoring to assess the impact on transient and dynamic stability. This study presents a measurement-based method for the early detection of power system oscillations, with consideration of mode damping, in order to raise alarms and develop strategies to actively improve power system dynamic stability and security. A method is developed based on wavelet-based support vector data description (SVDD) to detect oscillation modes in wind farm output power, which may excite dynamic instabilities in the wider system. The wavelet transform is used as a filter to identify oscillations in frequency bands, whereas the SVDD method is used to extract dominant features from different scales and generate an assessment boundary according to the extracted features. Poorly damped oscillations of a large magnitude, or that are resonant, can be alarmed to the system operator, to reduce the risk of system instability. The proposed method is exemplified using measured data from a chosen wind farm site.
Resumo:
The increasing penetration of wind generation on the Island of Ireland has been accompanied by close investigation of low-frequency pulsations contained within active power flow. A primary concern is excitation of low-frequency oscillation modes already present on the system, particularly the 0.75 Hz mode as a consequence of interconnection between the Northern and Southern power system networks. In order to determine whether the prevalence of wind generation has a negative effect (excites modes) or positive impact (damping of modes) on the power system, oscillations must be measured and characterised. Using time – frequency methods, this paper presents work that has been conducted to extract features from low-frequency active power pulsations to determine the composition of oscillatory modes which may impact on dynamic stability. The paper proposes a combined wavelet-Prony method to extract modal components and determine damping factors. The method is exemplified using real data obtained from wind farm measurements.
Resumo:
Over twenty years ago ‘Our Common Future’ presented a conceptualization and explanation of the concept of sustainable development. Since then numerous alternative definitions of the concept have been offered, of which at least some are exclusive to each other. At the same time, the role of business in the transition to sustainable development has increasingly received attention. Bringing these two trends in sustainable development together, this paper returns to the Brundtland version of the concept to examine to what extent the original principles of sustainable development are still embedded within key business guidelines, namely the UN Global Compact, the OECD Guidelines for Multinational Enterprises, the ICC Business Charter for Sustainable Development, the CAUX Principles, the Global Sullivan Principles and the CERES Principles. The findings suggest that these business guidelines tend to emphasize environmental rather than social aspects of sustainable development, in particular to the detriment of the original Brundtland prioritization of the needs of the poorest. Furthermore, the attention to environmental aspects stresses win-win situations and has a clear managerialist focus; whereas more conceptual environmental issues concerning systems interdependencies, critical thresholds or systemic limits to growth find little attention. The normative codes and principles targeted at the private sector thus not only add another voice to the multiple discourses on sustainable development but also contribute to a reinterpretation of the original agenda set by Brundtland towards conceptualizations of sustainable development around the needs of industrialised rather than developing countries. Copyright © 2011 John Wiley & Sons, Ltd and ERP Environment
Resumo:
To help the building of new low-carbon housing, recent years have seen the widespread demolition of Victorian housing in UK cities. In this regard, Belfast is no different from its counterparts on the British mainland, where Compulsory Purchase Orders force people to sell and vacate their terraced homes to make way for newly constructed 'sustainable' housing. The global economic downturn has temporarily slowed down this process leaving many Belfast terraces now blocked up awaiting future demolition. This stay of execution is an unlikely but welcome opportunity to review and assess the true value to owner, streetscape and city of this important and common house-type. Important questions need to be asked. Should sound Victorian terraces be demolished? What is the genuine cost of demolition and replacement in terms of community and environment? With reference to case studies in a Belfast context, the argument will be made that new is not necessarily better, that the existing Victorian terrace is an important and valuable resource and one that, with intelligent intervention, offers a genuinely sustainable alternative to new-build housing.
Resumo:
This work reviews the use of micron sized bubbles made from aqueous surfactant solution in environmental remediation. This is a novel technique and offers a low cost treatment option.
Resumo:
Abstract: The potential variance in feedstock costs can have signifi cant implications for the cost of a biofuel and the fi nancial viability of a biofuel facility. This paper employs the Grange Feed Costing Model to assess the cost of on-farm biomethane production using grass silages produced under a range of management scenarios. These costs were compared with the cost of wheat grain and sugarbeet roots for ethanol production at an industrial scale. Of the three feedstocks examined, grass silage represents the cheapest feedstock per GJ of biofuel produced. At a production cost of €27/tonne (t) feedstock (or €150/t volatile solids (VS)), the feedstock production cost of grass silage per gigajoule (GJ) of biofuel (€12.27) is lower than that of sugarbeet (€16.82) and wheat grain (€18.61). Grass biomethane is also the cheapest biofuel when grass silage is costed at the bottom quartile purchase price of silage of €19/t (€93/t VS). However, when considering the production costs (full-costing) of the three feedstocks, the total cost of grass biomethane (€32.37/GJ of biofuel; intensive 2-cut system) from a small on-farm facility ranks between that of sugarbeet (€29.62) and wheat grain ethanol (€34.31) produced in large industrial facilities. The feedstock costs for the above three biofuels represent 0.38, 0.57, and 0.54 of the total biofuel cost. The importance of feedstock cost on biofuel cost is further highlighted by the 0.43 increase in the cost of biomethane when grass silage is priced at the top quartile (€46/t or €232/t VS) compared to the bottom quartile purchase price.
Resumo:
Polymer based carbon aerogels were prepared by synthesis of a resorcinol formaldehyde gel followed by pyrolysis at 1073K under Ar and activation of the resultant carbon under CO2 at different temperatures. The prepared carbon aerogels were used as active materials in the preparation of cathode electrodes for lithium oxygen cells and the electrochemical performance of the cells was evaluated by galvanostatic charge/discharge cycling and electrochemical impedance measurements. It was shown that the storage capacity and discharge voltage of a Li/O2 cell strongly depend on the porous structure of the carbon used in cathode. EIS results also showed that the shape and value of the resistance in the impedance spectrum of a Li/O2 cell are strongly affected by the porosity of carbon used in the cathode. Porosity changes due to the build up of discharge products hinder the oxygen and lithium ion transfer into the electrode, resulting in a gradual increase in the cell impedance with cycling. The discharge capacity and cycle life of the battery decrease significantly as its internal resistance increases with charge/discharge cycling.
Resumo:
An electrochemical double layer capacitor test cell containing activated carbon xerogel electrodes and ionic liquid electrolyte was tested at 15, 25 and 40 OC to examine the effect of temperature on electrolyte resistance (RS) and equivalent series resistance (ESR) measured using impedance spectroscopy and capacitance using charge/discharge cycling. A commercial 10F capacitor was used as a comparison. Viscosity, ionic self-diffusion coefficients and differential scanning calorimetry measurements were used to provide an insight into the behaviour of the 1,2-dimethyl-3-propylimdazolium electrolyte. Both RS and ESR decreased with increasing temperature for both capacitors. Increasing the temperature also increased the capacitance for both the test cell and the commercial capacitor but proportionally more for the test cell. An increase in temperature decreased the ionic liquid electrolyte viscosity and increased the self diffusion coefficients of both the anion and the cation indicating an increase in dissociation and increase in ionic mobility.