975 resultados para Electrochemical noise signals


Relevância:

80.00% 80.00%

Publicador:

Resumo:

Parameters extracted from the wire beam electrode (WBE) galvanic current maps have been used in conjunction with electrochemical noise patterns to directly quantify the degree of localised corrosion inhibition provided by inhibitors and to understand the mechanism of localised corrosion inhibition. The behaviour of two traditional localised corrosion inhibitors has been assessed by their effects on the maximum anodic current density (imax), total anodic current density (itot), the number of anodic sites (Na) and the localised corrosion intensity index (LCII). Typical experiments are presented to illustrate the application of these parameters in providing useful information on the efficiency and mechanism of localised corrosion inhibition.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Organic coatings have been used in conjunction with cathodic protection as the most economical method of corrosion protection by the oil and gas pipeline industry. In a bid to prolong the life of the pipelines, the degradation and failure of pipeline coatings under the effects of major influencing factors including mechanical stress, the environmental corrosivity and cathodic protection have been extensively investigated over the past decades. This paper provides an overview of recent research for understanding coating degradation under the effect of these factors, either individually or in combination. Electrochemical impedance spectroscopy remains the primary and the most commonly used technique of studying the degradation of organic coatings, although there have been attempts to use other techniques such as electrochemical polarization (both dynamic and static), electrochemical noise, Scanning Kelvin Probe, Fourier Transform Infrared Spectroscopy, Differential Scanning Calorimetry and Dynamic Mechanical Analyser. Major knowledge and technological gaps in the investigation of the combined effects of mechanical stress, environmental corrosivity and cathodic protection on coating degradation have been identified.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Atom probe tomography (APT) has been used to investigate the surface and sub-surface microstructures of aluminum alloy 2024 (AA2024) in the T3 condition (solution heat treated, cold worked, and naturally aged to a substantially stable condition). This study revealed surface Cu enrichment on the alloy matrix, local chemical structure around a dispersoid Al20Mn3Cu2 particle including a Cu-rich particle and S-phase particle on its external surface. Moreover, there was a significant level of hydrogen within the dispersoid, indicating that it is a hydrogen sink. These observations of the nanoscale structure around the dispersoid particle have considerable implications for understanding both corrosion and hydrogen embrittlement in high-strength aluminum alloys.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Leakage in buried pipes is one of the main concerns for water companies due to the scarcity of potable water sources. Older metallic pipelines have been replaced by plastic pipes in such systems, which makes it more difficult to locate leaks using acoustics and vibration. This is mainly because of the high attenuation of leak signals caused by the damping in the pipe wall. To investigate acoustic methods in leak location in controlled conditions, a bespoke test rig was constructed in the UK. In this paper, data from this test-rig is used to discuss some issues that arise when using two contemporary correlators. Of particular interest, is the way in which a resonance in the system can have a profound effect on the estimate of the position of the leak depending on the way in which the leak noise signals are processed. © (2013) Trans Tech Publications.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Leaks in pipes are a common issue encountered in the water industry. Acoustic methods are generally successful in finding and locating leaks in metallic pipes, however, they are less effective when applied to plastic pipes. This is because leak-noise signals are heavily attenuated due to high damping in the pipe-wall and sound radiation into the soil. As result, high frequency leak noise does not travel long distances. To determine how far leak noise may travel in a pipe at any frequency, the attenuation of the wave responsible for leak noise propagation should be known. In this paper a new method to estimate this is described. The method is then applied to some measurements made on a bespoke pipe-test rig in the UK, and the results are compared with theoretical predictions.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The magnetic behaviour of most commercial ferromagnetic steels is usually anisotropic presenting a magnetic easy axis. Changes in the direction of this axis can be related to mechanical changes and anomalies that occur in the fabrication process. The present work describes a method that uses a device with permanent magnets to create a precise rotational magnetic field. The device measures continuous Magnetic Barkhausen Noise signals related to the angle of magnetization, in order to determine the direction of the macroscopic magnetic easy axis. It also offers the possibility of obtaining real time parameters that quantify the magnetic anisotropy of the sample. (C) 2011 Elsevier Ltd. All rights reserved.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Objective: To investigate objective and subjective effects of an adjunctive contralateral routing of signal (CROS) device at the untreated ear in patients with a unilateral cochlear implant (CI). Design: Prospective study of 10 adult experienced unilateral CI users with bilateral severe-to-profound hearing loss. Speech in noise reception (SNR) and sound localization were measured with and without the additional CROS device. SNR was measured by applying speech signals at the untreated/CROS side while noise signals came from the front (S90N0). For S0N90, signal sources were switched. Sound localization was measured in a 12-loudspeaker full circle setup. To evaluate the subjective benefit, patients tried the device for 2 weeks at home, then filled out the abbreviated Speech, Spatial and Qualities of Hearing Scale as well as the Bern benefit in single-sided deafness questionnaires. Results: In the setting S90N0, all patients showed a highly significant SNR improvement when wearing the additional CROS device (mean 6.4 dB, p < 0.001). In the unfavorable setting S0N90, only a minor deterioration of speech understanding was noted (mean -0.66 dB, p = 0.54). Sound localization did not improve substantially with CROS. In the two questionnaires, 12 of 14 items showed an improvement in mean values, but none of them was statistically significant. Conclusion: Patients with unilateral CI benefit from a contralateral CROS device, particularly in a noisy environment, when speech comes from the CROS ear side. © 2014 S. Karger AG, Basel.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

El objetivo del PFC es el diseño e implementación de una aplicación que funcione como osciloscopio, analizador de espectro y generador de funciones virtual, todo dentro de la misma aplicacion. Mediante una tarjeta de adquisición de datos tomaremos muestras de señales del mundo real (sistema analógico) para generar datos que puedan ser manipulados por un ordenador (sistema digital). Con esta misma tarjeta también se podrán generar señales básicas, tales como señales senoidales, cuadradas.... y además se ha añadido la funcionalidad de generar señales moduladas en frecuencia, señales tipo Chirp (usadas comúnmente tanto en aplicaciones sonar y radar, como en transmisión óptica) o PRN (ruido pseudo-aleatorio que consta de una secuencia determinista de pulsos que se repite cada periodo, usada comúnmente en receptores GPS), como también señales ampliamente conocidas como el ruido blanco Gaussiano o el ruido blanco uniforme. La aplicación mostrará con detalle las señales adquiridas y analizará de diversas maneras esas señales. Posee la función de enventanado de los tipos de ventana mas comunes, respuesta en frecuencia, transformada de Fourier, etc. La configuración es elegida por el usuario en un entorno amigable y de visualización atractiva. The objective of the PFC is the design and implementation of an application that works as oscilloscope, spectrum analyzer and virtual signal generator, all within the same application. Through a data acquisition card, the user can take samples of real-world signals (analog system) to generate data that can be manipulated by a computer (digital system). This same card can also generate basic signals, such as sine waves, square waves, sawtooth waves.... and further has added other functionalities as frequency modulated signals generation, Chirp signals type generation (commonly used in both sonar and radar applications, such as optical transmission) or PRN (pseudo-random noise sequence comprising a deterministic pulse that repeats every period, commonly used in GPS receivers). It also can generate widely known as Gaussian white noise signals or white noise uniform signals. The application will show in detail the acquired signals and will analyze these signals in different ways selected by the user. Windowing function has the most common window types, frequency response, Fourier transform are examples of what kind of analyzing that can be processed. The configuration is chosen by the user throught friendly and attractive displays and panels.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

A number of factors relating to various methods of repair for chloride initiated corrosion damage of reinforced concrete have been studied. A novel methodology has been developed to facilitate the measurement of macro and micro-cell corrosion rates for steel electrodes embedded in mortar prisms containing a chloride gradient. The galvanic bar specimen comprised electrically isolatable segmental mild steel electrodes and was constructed such that macro-cell corrosion currents were determinable for a number of electrode combinations. From this, the conditions giving rise to an incipient anode were established. The influence of several reinforcement and substrate primer systems upon macro-cell corrosion, arising from an incipient anode, within a patch repair have been investigated. Measurements of electrochemical noise were made in order to investigate the suitability of the technique as an on-site means of assessing corrosion activity within chloride contaminated reinforced concrete. For this purpose the standard deviation of potential noise was compared to macro-cell galvanic current data and micro-cell corrosion intensity determined by linear polarisation. Hydroxyl ion pore solution analyses were carried out on mortar taken from cathodically protected specimens. These specimens, containing sodium chloride, were cathodically protected over a range of polarisation potentials. Measurement of the hydroxyl ion concentrations were made in order to examine the possibility of alkali-silica reactions initiated by cathodic protection of reinfored concrete. A range of mortars containing a variety of generic type additives were examined in order to establish their resistances to chloride ion diffusion. The effect of surfactant addition rate was investigated within a cement paste containing various dosages of naphthalene sulphonate.