997 resultados para Electric circuit


Relevância:

60.00% 60.00%

Publicador:

Resumo:

Studies on the distribution of plantar pressure between the sole of the foot and the ground were developed before the 19th century. Currently, the most often employed plantar pressure measurement systems are Pedar® and FScan®, which have restrictions such as operational difficulty and high cost. In the present study, a device was constructed from two pressure plates capable of measuring plantar forces in discreet areas of the feet at a low cost, using strain-gages attached to sixteen strategic points of the mechanical elements. Sixteen prismatic beams were soldered to each frame, for which the free extremity of each beam represented a specific point of the foot. Two strain gauges were attached to each beam - one near the upper fixed extremity and the other near the lower fixed extremity. Using a Wheatstone bridge electric circuit, the gauges were used to measure the force acting on the extremity of the beam. Precision and accuracy of the prototype was about 10%. In some measurements, accuracy was 2%. The low precision and accuracy were mainly due to the restrictions of the available equipment, which only permitted four measurements at a time. Thus, it was necessary for participants to stand on the plates four separate times, which signified possible changes in the position of the feet on the pressure plates. Despite some limitations, the aim was achieved. The prototype has been used in some studies and represents a contribution to biomechanics, demonstrating the viability of using strain gauges.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

A transmission line digital model is developed direct in the phase and time domains. The successive modal transformations considered in the three-phase representation are simplified and then the proposed model can be easily applied to several operation condition based only on the previous knowing of the line parameters, without a thorough theoretical knowledge of modal analysis. The proposed model is also developed based on lumped elements, providing a complete current and voltage profile at any point of the transmission system. This model makes possible the modeling of non-linear power devices and electromagnetic phenomena along the transmission line using simple electric circuit components, representing a great advantage when compared to several models based on distributed parameters and inverse transforms. In addition, an efficient integration method is proposed to solve the system of differential equations resulted from the line modeling by lumped elements, thereby making possible simulations of transient and steady state using a wide and constant integration step. © 2012 IEEE.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Nanostructured films of dioctadecyldimethylammonium bromide (DODAB) and nickel tetrasulfonated phthalocyanine (NiTsPc) were layer-by-layer (LbL) assembled to achieve a synergistic effect considering the distinct properties of both materials. Prior to LbL growth, the effect of NiTsPc on the structure of DODAB vesicles in aqueous medium was investigated by differential scanning calorimetry (DSC). Therefore, DODAB/NiTsPc LbL films were prepared using NiTsPc at concentrations below and above the limit concentration of vesicle formation according to our DSC experiments. As a result, LbL films with distinct nanostructures were obtained, which were studied at micro and nanoscales by micro-Raman and atomic force microscopy, respectively. A linear growth of the LbL films was observed by ultraviolet-visible absorption spectroscopy. However, the bilayer thickness and the surface morphology of the LbL films were radically affected depending on NiTsPc concentration. The electrostatic interaction between DODAB and NiTsPc was identified via Fourier transform infrared (FTIR) absorption spectroscopy as the main driving force responsible for LbL growth. Because LbL films have been widely applied as transducers in sensing devices, DODAB/NiTsPc LbL films having distinct nanostructures were tested as proof-of-principle in preliminary sensing experiments toward dopamine detection using impedance spectroscopy (e-tongue system). The real capacitance vs. dopamine concentration curves were treated using Principal Component Analysis (PCA) and an equivalent electric circuit, revealing the role played by the LbL film nanostructure and the possibility of building calibration curves. © 2013 Elsevier B.V.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Pós-graduação em Engenharia Elétrica - FEIS

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The use of piezoelectric materials for the development of electromechanical devices for the harvesting or scavenging of ambient vibrations has been extensively studied over the last decade. The energy conversion from mechanical (vibratory) to electrical energy is provided by the electromechanical coupling between mechanical strains/stresses and electric charges/voltages in the piezoelectric material. The majority of the studies found in the open literature present a tip-mass cantilever piezoelectric device tuned on the operating frequency. Although recent results show that these devices can be quite effective for harvesting small amounts of electrical energy, little has been published on the robustness of these devices or on the effect of parametric uncertainties on the energy harvested. This work focuses on a cantilever plate with bonded piezoelectric patches and a tip-mass serving as an energy harvesting device. The rectifier and storage electric circuit was replaced by a resistive circuit (R). In addition, an alternative to improve the harvesting performance by adding an inductance in series to the harvesting circuit, thus leading to a resonant circuit (RL), is considered. A coupled finite element model leading to mechanical (displacements) and electrical (charges at electrodes) degrees of freedom is considered. An analysis of the effect of parametric uncertainties of the device on the electric output is performed. Piezoelectric and dielectric constants of the piezoelectric active layers and electric circuit equivalent inductance are considered as stochastic parameters. Mean and confidence intervals of the electric output are evaluated.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Untersuchungen zur Zell-Transistor Kopplung mittels der Voltage-Clamp TechnikIn der vorliegenden Arbeit wird die extrazelluläre Einkopplung elektrischer Signale von Zellen in Transistoren hinsichtlich der an der Kopplung beteiligten Parameter untersucht. Dafür werden Zellen aus Primärkulturen und von Zell-Linien direkt auf den aktiven Sensorflächen der hergestellten Chips kultiviert. Für die Experimente werden n- und p-Kanal Feldeffekttransistoren (FET) sowie Extended-Gate-Elektroden (EGE) mit Gold- und Titanoberflächen entwickelt.Zur Untersuchung der Kopplungseigenschaften werden die neuronale Zell-Linie SH-SY5Y, die humane Endothel Zell-Linie EA.hy-926 sowie als Primärzellen hippocampale Neuronen und Kardiomyozyten embryonaler und neonataler Ratten eingesetzt. Die Voltage-Clamp Technik erlaubt die Untersuchung spannungsgesteuerter Ionenkanäle in der Zellmembran. Maßgebend für den Signalverlauf des extrazellulär eingekoppelten Signals ist der Ionenstrom von Na+, K+ und Ca2+ durch die Membran im Kontaktbereich zwischen Zelle und Sensor.Die Kopplung kann elektrisch mithilfe eines Ersatzschaltkreises beschrieben werden, der alle beteiligten elektrischen Größen der Membran und der Ionenströme, sowie die Parameter des Kontaktbereichs und des Sensors enthält.Die Simulation der extrazellulären Signale zeigt, dass die beobachteten Signalformen nur durch eine Erhöhung der Ionenkanaldichten und dadurch einer deutlich vergrößerten Leitfähigkeit der Ionenarten im Kontaktbereich gegenüber der freien Membran erklärt werden können.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The quench characteristics of second generation (2 G) YBCO Coated Conductor (CC) tapes are of fundamental importance for the design and safe operation of superconducting cables and magnets based on this material. Their ability to transport high current densities at high temperature, up to 77 K, and at very high fields, over 20 T, together with the increasing knowledge in their manufacturing, which is reducing their cost, are pushing the use of this innovative material in numerous system applications, from high field magnets for research to motors and generators as well as for cables. The aim of this Ph. D. thesis is the experimental analysis and numerical simulations of quench in superconducting HTS tapes and coils. A measurements facility for the characterization of superconducting tapes and coils was designed, assembled and tested. The facility consist of a cryostat, a cryocooler, a vacuum system, resistive and superconducting current leads and signal feedthrough. Moreover, the data acquisition system and the software for critical current and quench measurements were developed. A 2D model was developed using the finite element code COMSOL Multiphysics R . The problem of modeling the high aspect ratio of the tape is tackled by multiplying the tape thickness by a constant factor, compensating the heat and electrical balance equations by introducing a material anisotropy. The model was then validated both with the results of a 1D quench model based on a non-linear electric circuit coupled to a thermal model of the tape, to literature measurements and to critical current and quench measurements made in the cryogenic facility. Finally the model was extended to the study of coils and windings with the definition of the tape and stack homogenized properties. The procedure allows the definition of a multi-scale hierarchical model, able to simulate the windings with different degrees of detail.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Results of the methodology presented in [1] is shown in this document. By means of the equivalent circuit model [2][3] of the slot, a combination of Method of Moments (MoM) and Forward Matching Procedure (FMP) is used to design a sub-array of compound slots. According to this, the system can be seen as a matched electric circuit and/or as a Nelements radiating device. Comparison between commercial solvers and proposed method are shown in this document, revealing that the mutual coupling between elements is a tiltingangle-dependant parameter.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The interest in LED lighting has been growing recently due to the high efficacy, lifelime and ruggedness that this technology offers. However the key element to guarantee those parameters with these new electronic devices is to keep under control the working temperature of the semiconductor crystal. This paper propases a LED lamp design that fulfils the requ irements of a PV lighting systems, whose main quality criteria is reliability. It uses directly as a power supply a non·stabilized constant voltage source, as batteries. An electronic control architecture is used to regulate the current applied to the LEO matri)( according to their temperature and the voltage output value of the batteries with two pulse modulation signals (PWM) signals. The first one connects and disconnects the LEOs to the power supply and the second one connects and disconnects several emitters to the electric circuit changing its overall impedance. A prototype of the LEO lamp has been implemented and tested at different temperaturas and battery voltages.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The 1-diode/2-resistors electric circuit equivalent to a photovoltaic system is analyzed. The equations at particular points of the I–V curve are studied considering the maximum number of terms. The maximum power point as a boundary condition is given special attention. A new analytical method is developed based on a reduced amount of information, consisting in the normal manufacturer data. Results indicate that this new method is faster than numerical methods and has similar (or better) accuracy than other existing methods, numerical or analytical.