649 resultados para ECHOCARDIOGRAPHY


Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: Compare changes in P-wave amplitude of the intra-atrial electrocardiogram (ECG) and its corresponding transesophageal echocardiography (TEE)-controlled position to verify the exact localization of a central venous catheter (CVC) tip. DESIGN: A prospective study. SETTING: University, single-institutional setting. PARTICIPANTS: Two hundred patients undergoing elective cardiac surgery. INTERVENTIONS: CVC placement via the right internal jugular vein with ECG control using the guidewire technique and TEE control in 4 different phases: phase 1: CVC placement with normalized P wave and measurement of distance from the crista terminalis to the CVC tip; phase 2: TEE-controlled placement of the CVC tip; parallel to the superior vena cava (SVC) and measurements of P-wave amplitude; phase 3: influence of head positioning on CVC migration; and phase 4: evaluation of positioning of the CVC postoperatively using a chest x-ray. MEASUREMENTS AND MAIN RESULTS: The CVC tip could only be visualized in 67 patients on TEE with a normalized P wave. In 198 patients with the CVC parallel to the SVC wall controlled by TEE (phase 2), an elevated P wave was observed. Different head movements led to no significant migration of the CVC (phase 3). On a postoperative chest-x-ray, the CVC position was correct in 87.6% (phase 4). CONCLUSION: The study suggests that the position of the CVC tip is located parallel to the SVC and 1.5 cm above the crista terminalis if the P wave starts to decrease during withdrawal of the catheter. The authors recommend that ECG control as per their study should be routinely used for placement of central venous catheters via the right internal jugular vein.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Chronic heart transplant rejection, i.e. cardiac allograft vasculopathy (CAV) is a major adverse prognostic factor after heart transplantation (HTx). This study tested the hypothesis that the relative myocardial blood volume (rBV) as quantified by myocardial contrast echocardiography accurately detects severe CAV as defined by coronary intravascular ultrasound (IVUS).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND Patent foramen ovale (PFO) is associated with cryptogenic stroke (CS), although the pathogenicity of a discovered PFO in the setting of CS is typically unclear. Transesophageal echocardiography features such as PFO size, associated hypermobile septum, and presence of a right-to-left shunt at rest have all been proposed as markers of risk. The association of these transesophageal echocardiography features with other markers of pathogenicity has not been examined. METHODS AND RESULTS We used a recently derived score based on clinical and neuroimaging features to stratify patients with PFO and CS by the probability that their stroke is PFO-attributable. We examined whether high-risk transesophageal echocardiography features are seen more frequently in patients more likely to have had a PFO-attributable stroke (n=637) compared with those less likely to have a PFO-attributable stroke (n=657). Large physiologic shunt size was not more frequently seen among those with probable PFO-attributable strokes (odds ratio [OR], 0.92; P=0.53). The presence of neither a hypermobile septum nor a right-to-left shunt at rest was detected more often in those with a probable PFO-attributable stroke (OR, 0.80; P=0.45; OR, 1.15; P=0.11, respectively). CONCLUSIONS We found no evidence that the proposed transesophageal echocardiography risk markers of large PFO size, hypermobile septum, and presence of right-to-left shunt at rest are associated with clinical features suggesting that a CS is PFO-attributable. Additional tools to describe PFOs may be useful in helping to determine whether an observed PFO is incidental or pathogenically related to CS.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

AIMS: We conducted a meta-analysis to evaluate the accuracy of quantitative stress myocardial contrast echocardiography (MCE) in coronary artery disease (CAD). METHODS AND RESULTS: Database search was performed through January 2008. We included studies evaluating accuracy of quantitative stress MCE for detection of CAD compared with coronary angiography or single-photon emission computed tomography (SPECT) and measuring reserve parameters of A, beta, and Abeta. Data from studies were verified and supplemented by the authors of each study. Using random effects meta-analysis, we estimated weighted mean difference (WMD), likelihood ratios (LRs), diagnostic odds ratios (DORs), and summary area under curve (AUC), all with 95% confidence interval (CI). Of 1443 studies, 13 including 627 patients (age range, 38-75 years) and comparing MCE with angiography (n = 10), SPECT (n = 1), or both (n = 2) were eligible. WMD (95% CI) were significantly less in CAD group than no-CAD group: 0.12 (0.06-0.18) (P < 0.001), 1.38 (1.28-1.52) (P < 0.001), and 1.47 (1.18-1.76) (P < 0.001) for A, beta, and Abeta reserves, respectively. Pooled LRs for positive test were 1.33 (1.13-1.57), 3.76 (2.43-5.80), and 3.64 (2.87-4.78) and LRs for negative test were 0.68 (0.55-0.83), 0.30 (0.24-0.38), and 0.27 (0.22-0.34) for A, beta, and Abeta reserves, respectively. Pooled DORs were 2.09 (1.42-3.07), 15.11 (7.90-28.91), and 14.73 (9.61-22.57) and AUCs were 0.637 (0.594-0.677), 0.851 (0.828-0.872), and 0.859 (0.842-0.750) for A, beta, and Abeta reserves, respectively. CONCLUSION: Evidence supports the use of quantitative MCE as a non-invasive test for detection of CAD. Standardizing MCE quantification analysis and adherence to reporting standards for diagnostic tests could enhance the quality of evidence in this field.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

INTRODUCTION Hemodynamic management in intensive care patients guided by blood pressure and flow measurements often do not sufficiently reveal common hemodynamic problems. Trans-esophageal echocardiography (TEE) allows for direct measurement of cardiac volumes and function. A new miniaturized probe for TEE (mTEE) potentially provides a rapid and simplified approach to monitor cardiac function. The aim of the study was to assess the feasibility of hemodynamic monitoring using mTEE in critically ill patients after a brief operator training period. METHODS In the context of the introduction of mTEE in a large ICU, 14 ICU staff specialists with no previous TEE experience received six hours of training as mTEE operators. The feasibility of mTEE and the quality of the obtained hemodynamic information were assessed. Three standard views were acquired in hemodynamically unstable patients: 1) for assessment of left ventricular function (LV) fractional area change (FAC) was obtained from a trans-gastric mid-esophageal short axis view, 2) right ventricular (RV) size was obtained from mid-esophageal four chamber view, and 3) superior vena cava collapsibility for detection of hypovolemia was assessed from mid-esophageal ascending aortic short axis view. Off-line blinded assessment by an expert cardiologist was considered as a reference. Inter-rater agreement was assessed using Chi-square tests or correlation analysis as appropriate. RESULTS In 55 patients, 148 mTEE examinations were performed. Acquisition of loops in sufficient quality was possible in 110 examinations for trans-gastric mid-esophageal short axis, 118 examinations for mid-esophageal four chamber and 125 examinations for mid-esophageal ascending aortic short axis view. Inter-rater agreement (Kappa) between ICU mTEE operators and the reference was 0.62 for estimates of LV function, 0.65 for RV dilatation, 0.76 for hypovolemia and 0.77 for occurrence of pericardial effusion (all P < 0.0001). There was a significant correlation between the FAC measured by ICU operators and the reference (r = 0.794, P (one-tailed) < 0.0001). CONCLUSIONS Echocardiographic examinations using mTEE after brief bed-side training were feasible and of sufficient quality in a majority of examined ICU patients with good inter-rater reliability between mTEE operators and an expert cardiologist. Further studies are required to assess the impact of hemodynamic monitoring by mTEE on relevant patient outcomes.

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVES We sought to assess the safety and efficacy of percutaneous closure of atrial septal defects (ASDs) under fluoroscopic guidance only, without periprocedural echocardiographic guidance. BACKGROUND Percutaneous closure of ASDs is usually performed using simultaneous fluoroscopic and transthoracic, transesophageal (TEE), or intracardiac echocardiographic (ICE) guidance. However, TEE requires deep sedation or general anesthesia, which considerably lengthens the procedure. TEE and ICE increase costs. METHODS Between 1997 and 2008, a total of 217 consecutive patients (age, 38 ± 22 years; 155 females and 62 males), of whom 44 were children ≤16 years, underwent percutaneous ASD closure with an Amplatzer ASD occluder (AASDO). TEE guidance and general anesthesia were restricted to the children, while devices were implanted under fluoroscopic guidance only in the adults. For comparison of technical safety and feasibility of the procedure without echocardiographic guidance, the children served as a control group. RESULTS The implantation procedure was successful in all but 3 patients (1 child and 2 adults; 1.4%). Mean device size was 23 ± 8 mm (range, 4-40 mm). There was 1 postprocedural complication (0.5%; transient perimyocarditis in an adult patient). At last echocardiographic follow-up, 13 ± 23 months after the procedure, 90% of patients had no residual shunt, whereas a minimal, moderate, or large shunt persisted in 7%, 1%, and 2%, respectively. Four adult patients (2%) underwent implantation of a second device for a residual shunt. During a mean follow-up period of 3 ± 2 years, 2 deaths and 1 ischemic stroke occurred. CONCLUSION According to these results, percutaneous ASD closure using the AASDO without periprocedural echocardiographic guidance seems safe and feasible.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

AIMS While zebrafish embryos are amenable to in vivo imaging, allowing the study of morphogenetic processes during development, intravital imaging of adults is hampered by their small size and loss of transparency. The use of adult zebrafish as a vertebrate model of cardiac disease and regeneration is increasing at high speed. It is therefore of great importance to establish appropriate and robust methods to measure cardiac function parameters. METHODS AND RESULTS Here we describe the use of 2D-echocardiography to study the fractional volume shortening and segmental wall motion of the ventricle. Our data show that 2D-echocardiography can be used to evaluate cardiac injury and also to study recovery of cardiac function. Interestingly, our results show that while global systolic function recovered following cardiac cryoinjury, ventricular wall motion was only partially restored. CONCLUSION Cryoinjury leads to long-lasting impairment of cardiac contraction, partially mimicking the consequences of myocardial infarction in humans. Functional assessment of heart regeneration by echocardiography allows a deeper understanding of the mechanisms of cardiac regeneration and has the advantage of being easily transferable to other cardiovascular zebrafish disease models.