870 resultados para Dynamic and Deliberative Curriculum Renewal


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Models play a vital role in supporting a range of activities in numerous domains. We rely on models to support the design, visualisation, analysis and representation of parts of the world around us, and as such significant research effort has been invested into numerous areas of modelling; including support for model semantics, dynamic states and behaviour, temporal data storage and visualisation. Whilst these efforts have increased our capabilities and allowed us to create increasingly powerful software-based models, the process of developing models, supporting tools and /or data structures remains difficult, expensive and error-prone. In this paper we define from literature the key factors in assessing a model’s quality and usefulness: semantic richness, support for dynamic states and object behaviour, temporal data storage and visualisation. We also identify a number of shortcomings in both existing modelling standards and model development processes and propose a unified generic process to guide users through the development of semantically rich, dynamic and temporal models.

Relevância:

100.00% 100.00%

Publicador:

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Yellow passion fruit pulp is unstable, presenting phase separation that can be avoided by the addition of hydrocolloids. For this purpose, xanthan and guar gum [0.3, 0.7 and 1.0% (w/w)] were added to yellow passion fruit pulp and the changes in the dynamic and steady-shear rheological behavior evaluated. Xanthan dispersions showed a more pronounced pseudoplasticity and the presence of yield stress, which was not observed in the guar gum dispersions. Cross model fitting to flow curves showed that the xanthan suspensions also had higher zero shear viscosity than the guar suspensions, and, for both gums, an increase in temperature led to lower values for this parameter. The gums showed different behavior as a function of temperature in the range of 5-35 degrees C. The activation energy of the apparent viscosity was dependent on the shear rate and gum concentration for guar, whereas for xanthan these values only varied with the concentration. The mechanical spectra were well described by the generalized Maxwell model and the xanthan dispersions showed a more elastic character than the guar dispersions, with higher values for the relaxation time. Xanthan was characterized as a weak gel, while guar presented a concentrated solution behavior. The simultaneous evaluation of temperature and concentration showed a stronger influence of the polysaccharide concentration on the apparent viscosity and the G` and G `` moduli than the variation in temperature.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The objective of this study was to analyze the electromyographic (EMG) signal behavior of rectus femoris (RF), vastus medialis (VM), vastus lateralis (VL) and biceps femoris (caput longum) (BFCL) from nine women during fatiguing dynamic and isometric knee extensions tests and to determine their EMGFT (Electromyographic Fatigue Threshold). Surface electrodes, biological signal acquisition module, analogical-digital converter board and specific software were used. The RMS (Root Mean Square) values obtained from concentric phase (80 to 30 degrees) of the dynamic knee extension andfrom isometric contraction were correlated with time on each load by linear regression analysis. The respective slopes were correlated with the correspondent load to determine the EMGFT. Force (Kgf) and median frequency - MF (Hz) obtained during MIVC (Maximal Isometric Voluntary Contraction) performed before and after the fatiguing tests were calculated in Matlab environment. The results demonstrated that the endurance time decreases with higher loads the EMG amplitude increase with time and was greater at higher loads, between muscles in dynamic exercise the RF and VL showed higher slopes, and in isometric exercise the VL showed the same behavior The EMGFT values were similar in both exercises; the force values predominantly decreased after fatiguing tests; however the MF only decreased after some loads. The protocols proposed allowed standardizing protocols at least to induce the fatigue process and to determine the EMGFT as an endurance indicative, which may be used to evaluate the effectiveness of rehabilitative or training interventions indicated to reduce muscle weakness and fatigue.

Relevância:

100.00% 100.00%

Publicador:

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Excessive rearfoot eversion is thought to be a risk factor for patellofemoral pain development, due to the kinesiological relationship with ascendant adaptations. Individuals with patellofemoral pain are often diagnosed through static clinical tests, in scientific studies and clinical practice. However, the adaptations seem to appear in dynamic conditions. Performing static vs. dynamic evaluations of widely used measures would add to the knowledge in this area. Thus, the aim of this study was to determine the reliability and differentiation capability of three rearfoot eversion measures: rearfoot range of motion, static clinical test and static measurement using a three-dimensional system. A total of 29 individuals with patellofemoral pain and 25 control individuals (18-30 years) participated in this study. Each subject underwent three-dimensional motion analysis during stair climbing and static clinical tests. Intraclass correlation coefficient and standard error measurements were performed to verify the reliability of the variables and receiver operating characteristic curves to show the diagnostic accuracy of each variable. In addition, analyses of variance were performed to identify differences between groups. Rearfoot range of motion demonstrated higher diagnostic accuracy (an area under the curve score of 0.72) than static measures and was able to differentiate the groups. Only the static clinical test presented poor and moderate reliability. Other variables presented high to very high values. Rearfoot range of motion was the variable that presented the best results in terms of reliability and differentiation capability. Static variables do not seem to be related to patellofemoral pain and have low accuracy values.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Food and Nutrition Security (FNS) must be ensured to everybody. The school environment is favorable to the formation of healthy habits and citizenship. The National Curriculum Parameters (PCNs) guide the promotion of health concepts in a transversal way in the school curriculum. This study aimed to identify and analyze the approach used for food and nutrition themes in Fundamental Education's teaching material and its interface with the concept of FNS and the PCNs. Documental research was conducted on the teaching material from 5th to 8th grades of Fundamental Education in Public School of the state of Sao Paulo. The diffuse presence of food and nutrition themes was found in most disciplines in all bimesters in the four series, which shows the interdisciplinarity in health. It was found that the PCNs are related to the concept of SAN in its various aspects and that most subjects include topics that approach this relationship. In the correlation between themes, there is emphasis to health promotion and food production. The methodology used in the teaching material presents the theme, but not the correspondent content, what made the analysis of its suitability impossible. We conclude that there is the approach of the issues related to food and nutrition in the teaching material, some of them in an inconsistent way; it is the educators' task to select the contents and the appropriate strategy, doing an effort of constant update. This isbeing proposed by the State, however it is not accessible to all professionals and therefore still depends on the initiative of each teacher.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A review of Reducing Adolescent Sexual Risk: A Theoretical Guide for Developing and Adapting Curriculum-Based Programs by Douglas Kirby.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

STUDY DESIGN Biomechanical cadaveric study. OBJECTIVE To determine whether augmentation positively influence screw stability or not. SUMMARY OF BACKGROUND DATA Implantation of pedicle screws is a common procedure in spine surgery to provide an anchorage of posterior internal fixation into vertebrae. Screw performance is highly correlated to bone quality. Therefore, polymeric cement is often injected through specifically designed perforated pedicle screws into osteoporotic bone to potentially enhance screw stability. METHODS Caudocephalic dynamic loading was applied as quasi-physiological alternative to classical pull-out tests on 16 screws implanted in osteoporotic lumbar vertebrae and 20 screws in nonosteoporotic specimen. Load was applied using 2 different configurations simulating standard and dynamic posterior stabilization devices. Screw performance was quantified by measurement of screwhead displacement during the loading cycles. To reduce the impact of bone quality and morphology, screw performance was compared for each vertebra and averaged afterward. RESULTS All screws (with or without cement) implanted in osteoporotic vertebrae showed lower performances than the ones implanted into nonosteoporotic specimen. Augmentation was negligible for screws implanted into nonosteoporotic specimen, whereas in osteoporotic vertebrae pedicle screw stability was significantly increased. For dynamic posterior stabilization system an increase of screwhead displacement was observed in comparison with standard fixation devices in both setups. CONCLUSION Augmentation enhances screw performance in patients with poor bone stock, whereas no difference is observed for patients without osteoporosis. Furthermore, dynamic stabilization systems have the possibility to fail when implanted in osteoporotic bone.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

From laboratory tests under simulated downhole conditions we tentatively conclude that the higher the triaxial-compressive strength, the lower the drilling rate of basalts from DSDP Hole 504B. Because strength is roughly proportional to Young's modulus of elasticity, which is related in turn to seismic-wave velocities, one may be able to estimate drilling rates from routine shipboard measurements. However, further research is needed to verify that P-wave velocity is a generally useful predictor of relative drilling rate.