967 resultados para Drying energy saving
Resumo:
This PhD work arises from the necessity to give a contribution to the energy saving field, regarding automotive applications. The aim was to produce a multidisciplinary work to show how much important is to consider different aspects of an electric car realization: from innovative materials to cutting-edge battery thermal management systems (BTMSs), also dealing with the life cycle assessment (LCA) of the battery packs (BPs). Regarding the materials, it has been chosen to focus on carbon fiber composites as their use allows realizing light products with great mechanical properties. Processes and methods to produce carbon fiber goods have been analysed with a special attention on the university solar car Emilia 4. The work proceeds dealing with the common BTMSs on the market (air-cooled, cooling plates, heat pipes) and then it deepens some of the most innovative systems such as the PCM-based BTMSs after a previous experimental campaign to characterize the PCMs. After that, a complex experimental campaign regarding the PCM-based BTMSs has been carried on, considering both uninsulated and insulated systems. About the first category the tested systems have been pure PCM-based and copper-foam-loaded-PCM-based BTMSs; the insulated tested systems have been pure PCM-based and copper-foam-loaded-PCM-based BTMSs and both of these systems equipped with a liquid cooling circuit. The choice of lighter building materials and the optimization of the BTMS are strategies which helps in reducing the energy consumption, considering both the energy required by the car to move and the BP state of health (SOH). Focusing on this last factor, a clear explanation regarding the importance of taking care about the SOH is given by the analysis of a BP production energy consumption. This is why a final dissertation about the life cycle assessment (LCA) of a BP unit has been presented in this thesis.
Resumo:
Työn aiheena oli tutkia vaahdon soveltuvuutta ohuiden päällystyskerrosten applikointiin paperin tai kartongin pinnalle. Paperia ja kartonkia päällystetään teollisessa mittakaavassa eri menetelmillä, mutta niille kaikille yhteistä on päällystyspastan laimentaminen vedellä ennen applikointia ja laimennusveden haihduttaminen applikoinnin jälkeen päällysteen asettamiseksi. Laimennus on tärkeää pastan komponenttien tasaisen levittämisen vuoksi, mutta veden haihduttaminen kuluttaa valtavasti energiaa. Tekstiiliteollisuudessa on saavutettu merkittäviä säästöjä kuivausenergiassa korvaamalla laajalti vedellä laimentaminen vaahdottamisella. Diplomityön kirjallisessa osassa käytiin läpi vaahdon kemiallisia ja fysikaalisia ominaisuuksia sekä selvitettiin mitä kemikaaleja ja laitteita vaahdotukseen käytetään. Lisäksi luotiin katsaus vaahtoprosessien käyttöön tekstiiliteollisuudessa ja muilla aloilla. Kokeellinen osa koostui esikokeista, joissa selvitettiin pastan koostumuksen vaikutuksia vaahtoamiseen, ja pilot-mittakaavan koeajoista, joissa esikokeiden tuloksia hyödynnettiin. Esikokeissa huomiota kiinnitettiin varsinkin eri polyvinyylialkoholien (PVA) seosten erinomaiseen vaahtoavuuteen. Pilot-koeajoissa vaahtopäällystys vaikutti lupaavalta menetelmältä, joskaan täysin tyydyttävää päällystystulosta ei saavutettu. Suurimpana ongelmana esiintyi ilman pääseminen pohjapaperin ja päällysteen väliin ja siitä seuraava huono päällystejälki. Toisen ongelmakokonaisuuden muodostivat päällysteeseen jäävät reiät. Vaahtopäällystys vaikuttaa lupaavalta tekniikalta ohuiden päällystekerrosten applikointiin, mutta pastareseptejä tulee optimoida ja ratkaista päällysteen alle pääsevän ilman ongelma.
Resumo:
This thesis investigates the modelling of drying processes for the promotion of market-led Demand Side Management (DSM) as applied to the UK Public Electricity Suppliers. A review of DSM in the electricity supply industry is provided, together with a discussion of the relevant drivers supporting market-led DSM and energy services (ES). The potential opportunities for ES in a fully deregulated energy market are outlined. It is suggested that targeted industrial sector energy efficiency schemes offer significant opportunity for long term customer and supplier benefit. On a process level, industrial drying is highlighted as offering significant scope for the application of energy services. Drying is an energy-intensive process used widely throughout industry. The results of an energy survey suggest that 17.7 per cent of total UK industrial energy use derives from drying processes. Comparison with published work indicates that energy use for drying shows an increasing trend against a background of reducing overall industrial energy use. Airless drying is highlighted as offering potential energy saving and production benefits to industry. To this end, a comprehensive review of the novel airless drying technology and its background theory is made. Advantages and disadvantages of airless operation are defined and the limited market penetration of airless drying is identified, as are the key opportunities for energy saving. Limited literature has been found which details the modelling of energy use for airless drying. A review of drying theory and previous modelling work is made in an attempt to model energy consumption for drying processes. The history of drying models is presented as well as a discussion of the different approaches taken and their relative merits. The viability of deriving energy use from empirical drying data is examined. Adaptive neuro fuzzy inference systems (ANFIS) are successfully applied to the modelling of drying rates for 3 drying technologies, namely convective air, heat pump and airless drying. The ANFIS systems are then integrated into a novel energy services model for the prediction of relative drying times, energy cost and atmospheric carbon dioxide emission levels. The author believes that this work constitutes the first to use fuzzy systems for the modelling of drying performance as an energy services approach to DSM. To gain an insight into the 'real world' use of energy for drying, this thesis presents a unique first-order energy audit of every ceramic sanitaryware manufacturing site in the UK. Previously unknown patterns of energy use are highlighted. Supplementary comments on the timing and use of drying systems are also made. The limitations of such large scope energy surveys are discussed.
Resumo:
Drying is an important unit operation in process industry. Results have suggested that the energy used for drying has increased from 12% in 1978 to 18% of the total energy used in 1990. A literature survey of previous studies regarding overall drying energy consumption has demonstrated that there is little continuity of methods and energy trends could not be established. In the ceramics, timber and paper industrial sectors specific energy consumption and energy trends have been investigated by auditing drying equipment. Ceramic products examined have included tableware, tiles, sanitaryware, electrical ceramics, plasterboard, refractories, bricks and abrasives. Data from industry has shown that drying energy has not varied significantly in the ceramics sector over the last decade, representing about 31% of the total energy consumed. Information from the timber industry has established that radical changes have occurred over the last 20 years, both in terms of equipment and energy utilisation. The energy efficiency of hardwood drying has improved by 15% since the 1970s, although no significant savings have been realised for softwood. A survey estimating the energy efficiency and operating characteristics of 192 paper dryer sections has been conducted. Drying energy was found to increase to nearly 60% of the total energy used in the early 1980s, but has fallen over the last decade, representing 23% of the total in 1993. These results have demonstrated that effective energy saving measures, such as improved pressing and heat recovery, have been successfully implemented since the 1970s. Artificial neural networks have successfully been applied to model process characteristics of microwave and convective drying of paper coated gypsum cove. Parameters modelled have included product moisture loss, core gypsum temperature and quality factors relating to paper burning and bubbling defects. Evaluation of thermal and dielectric properties have highlighted gypsum's heat sensitive characteristics in convective and electromagnetic regimes. Modelling experimental data has shown that the networks were capable of simulating drying process characteristics to a high degree of accuracy. Product weight and temperature were predicted to within 0.5% and 5C of the target data respectively. Furthermore, it was demonstrated that the underlying properties of the data could be predicted through a high level of input noise.
Resumo:
O objectivo desta tese é dimensionar um secador em leito fluidizado para secagem de cereais, nomeadamente, secagem de sementes de trigo. Inicialmente determinaram-se as condições de hidrodinâmica (velocidade de fluidização, TDH, condições mínimas de “slugging”, expansão do leito, dimensionamento do distribuidor e queda de pressão). Com as condições de hidrodinâmica definidas, foi possível estimar as dimensões físicas do secador. Neste ponto, foram realizados estudos relativamente à cinética da secagem e à própria secagem. Foi também estudado o transporte pneumático das sementes. Deste modo, determinaram-se as velocidades necessárias ao transporte pneumático e respectivas quedas de pressão. Por fim, foi realizada uma análise custos para que se soubesse o custo deste sistema de secagem. O estudo da secagem foi feito para uma temperatura de operação de 50ºC, tendo a ressalva que no limite se poderia trabalhar com 60ºC. A velocidade de operação é de 2,43 m/s, a altura do leito fixo é de 0,4 m, a qual sofre uma expansão durante a fluidização, assumindo o valor de 0,79 m. O valor do TDH obtido foi de 1,97 m, que somado à expansão do leito permite obter uma altura total da coluna de 2,76 m. A altura do leito fixo permite retirar o valor do diâmetro que é de 0,52 m. Verifica-se que a altura do leito expandido é inferior à altura mínima de “slugging” (1,20 m), no entanto, a velocidade de operação é superior à velocidade mínima de “slugging” (1,13 m/s). Como só uma das condições mínimas é cumprida, existe a possibilidade da ocorrência de “slugging”. Finalmente, foi necessário dimensionar o distribuidor, que com o diâmetro de orifício de 3 mm, valor inferior ao da partícula (3,48 mm), permite a distruibuição do fluido de secagem na coluna através dos seus 3061 orifícios. O inicio do estudo da secagem centrou-se na determinação do tempo de secagem. Além das duas temperaturas atrás referidas, foram igualmente consideradas duas humidades iniciais para os cereais (21,33% e 18,91%). Temperaturas superiores traduzem-se em tempos de secagem inferiores, paralelamente, teores de humidade inicial inferiores indicam tempos menores. Para a temperatura de 50ºC, os tempos de secagem assumiram os valores de 2,8 horas para a 21,33% de humidade e 2,7 horas para 18,91% de humidade. Foram também tidas em conta três alturas do ano para a captação do ar de secagem, Verão e Inverno representando os extremos, e a Meia- Estação. Para estes três casos, foi possível verificar que a humidade específica do ar não apresenta alterações significativas entre a entrada no secador e a corrente de saída do mesmo equipamento, do mesmo modo que a temperatura de saída pouco difere da de entrada. Este desvio de cerca de 1% para as humidades e para as temperaturas é explicado pela ausência de humidade externa nas sementes e na pouca quantidade de humidade interna. Desta forma, estes desvios de 1% permitem a utilização de uma razão de reciclagem na ordem dos 100% sem que o comportamento da secagem se altere significativamente. O uso de 100% de reciclagem permite uma poupança energética de cerca de 98% no Inverno e na Meia-Estação e de cerca de 93% no Verão. Caso não fosse realizada reciclagem, seria necessário fornecer à corrente de ar cerca de 18,81 kW para elevar a sua temperatura de 20ºC para 50ºC (Meia-Estação), cerca de 24,67 kW para elevar a sua temperatura de 10ºC para 50ºC (Inverno) e na ordem dos 8,90 kW para elevar a sua temperatura dos 35ºC para 50ºC (Verão). No caso do transporte pneumático, existem duas linhas, uma horizontal e uma vertical, logo foi necessário estimar o valor da velocidade das partículas para estes dois casos. Na linha vertical, a velocidade da partícula é cerca de 25,03 m/s e cerca de 35,95 m/s na linha horizontal. O menor valor para a linha vertical prende-se com o facto de nesta zona ter que se vencer a força gravítica. Em ambos os circuitos a velocidade do fluido é cerca de 47,17 m/s. No interior da coluna, a velocidade do fluido tem o valor de 10,90 m/s e a velocidade das partículas é de 1,04 m/s. A queda de pressão total no sistema é cerca de 2408 Pa. A análise de custos ao sistema de secagem indicou que este sistema irá acarretar um custo total (fabrico mais transporte) de cerca de 153035€. Este sistema necessita de electricidade para funcionar, e esta irá acarretar um custo anual de cerca de 7951,4€. Embora este sistema de secagem apresente a possibilidade de se realizar uma razão de reciclagem na ordem dos 100% e também seja possível adaptar o mesmo para diferentes tipos de cereais, e até outros tipos de materiais, desde que possam ser fluidizados, o seu custo impede que a realização deste investimento não seja atractiva, especialmente tendo em consideração que se trata de uma instalação à escala piloto com uma capacidade de 45 kgs.
Resumo:
The global warming due to high CO2 emission in the last years has made energy saving a global problem nowadays. However, manufacturing processes such as pultrusion necessarily needs heat for curing the resin. Then, the only option available is to apply all efforts to make the process even more efficient. Different heating systems have been used on pultrusion, however, the most widely used are the planar resistances. The main objective of this study is to develop another heating system and compares it with the former one. Thermography was used in spite of define the temperature profile along the die. FEA (finite element analysis) allows to understand how many energy is spend with the initial heating system. After this first approach, changes were done on the die in order to test the new heating system and to check possible quality problems on the product. Thus, this work allows to conclude that with the new heating system a significant reduction in the setup time is now possible and an energy reduction of about 57% was achieved.
Resumo:
Tese de Doutoramento em Engenharia Civil.
Resumo:
As manufacturers face an increasingly competitive environment, they seek out opportunities to reduce production costs without negatively affecting the yield or the quality of their finished products. The challenge of maintaining high product quality while simultaneously reducing production costs can often be met through investments in energy efficient technologies and energy efficiency practices. Energy management systems can offer both technological and best practice efficiencies in order to achieve substantial savings. A strong energy management system provides a solid foundation for an organisation to reduce production costs and improve site efficiency. The I.S EN16001 energy management standard specifies the requirements for establishing, implementing, maintaining and improving an energy management system and represents the latest best practice for energy management in Ireland. The objective of the energy management system is to establish a systematic approach for improving energy performance continuously. The I.S EN16001 standard specifies the requirements for continuous improvement through using energy more efficiently. The author analysed how GlaxoSmithKline’s (GSK) pharmaceutical manufacturing facility in Cork implemented the I.S. EN16001 energy management system model, and defined how energy saving opportunities where identified and introduced to improve efficiency performance. The author performed an extensive literature research in order to determine the current status of the pharmaceutical industry in Ireland, the processes involved in pharmaceutical manufacturing, the energy users required for pharmaceutical manufacturing and the efficiency measures that can be applied to these energy users in order to reduce energy consumption. The author then analysed how energy management standards are introduced to industry and critically analysed the driving factors for energy management performance in Ireland through case studies. Following an investigation as to how the I.S. EN16001 energy management standard is operated in GSK, a critical analysis of the performance achieved by the GSK energy management system is undertaken in order to determine if implementing the I.S EN16001 standard accelerates achieving energy savings. Since its introduction, the I.S. EN16001 model for energy management has enabled GSK to monitor, target and identify energy efficiency opportunities throughout the site. The model has put in place an energy management system that is continuously reviewed for improvement and to date has reduced GSK’s site operations cost by over 30% through technical improvements and generating energy awareness for smarter energy consumption within the GSK Cork site. Investment in I.S. EN16001 has proved to be a sound business strategy for GSK especially in today's manufacturing environment.
Resumo:
In 2011, the National Energy Retrofit Programme will build upon existing energy saving programmes in both the domestic and non-domestic sectors. This consultation focused on key design considerations. IPH agree with the commitment to deliver a National Energy Retrofit Programme as a sustainable means of securing energy savings and reducing energy poverty and the nations carbon footprint. The IPH response highlighted the significant benefit to health and would support the use of Health Impact Assessment
Resumo:
BACKGROUND: Environmental conditions play a crucial role in mite growth, and optimal environmental control is key in the prevention of airway inflammation in chronic allergic rhinoconjunctivitis or asthma. OBJECTIVE: To evaluate the relationship between building energy performance and indoor mite allergen concentration in a cross-sectional study. METHODS: Major allergen concentration (Der f 1, Der p 1, mite group 2, Fel d 1 and Bla g 2) was determined by quantitative dot blot analysis from mattress and carpet dust samples in five buildings designed for low energy use (LEB) and in six control buildings (CB). Inhabitants had received 4 weeks prior to mite measurement a personal validated questionnaire related to the perceived state of health and comfort of living. RESULTS: Cumulative mite allergen concentration (with Der f 1 as the major contributor) was significantly lower in LEB as compared with CB both in mattresses and in carpets. In contrast, the two categories of buildings did not differ in Bla g 2 and Fel d 1 concentration, in the amount of dust and airborne mould collected. Whereas temperature was higher in LEB, relative humidity was significantly lower than in CB. Perceived overall comfort was better in LEB. CONCLUSIONS: Major mite allergen Der f 1 preferentially accumulates in buildings not specifically designed for low energy use, reaching levels at risk for sensitization. We hypothesize that controlled mechanical ventilation present in all audited LEB may favour lower air humidity and hence lower mite growth and allergen concentration, while preserving optimal perceived comfort.
Resumo:
The energy system of Russia is the world's fourth largest measured by installed power. The largest are that of the the United States of America, China and Japan. After 1990, the electricity consumption decreased as a result of the Russian industry crisis. The vivid economic growth during the latest few years explains the new increase in the demand for energy resources within the State. In 2005 the consumption of electricity achieved the maximum level of 1990 and continues to growth. In the 1980's, the renewal of power facilities was already very slow and practically stopped in the 1990's. At present, the energy system can be very much characterized as outdated, inefficient and uneconomic because of the old equipment, non-effective structure and large losses in the transmission lines. The aim of Russia's energy reform, which was started in 2001, is to achieve a market based energy policy by 2011. This would thus remove the significantly state-controlled monopoly in Russia's energy policy. The reform will stimulateto decrease losses, improve the energy system and employ energy-saving technologies. The Russian energy system today is still based on the use of fossil fuels, and it almost totally ignores the efficient use of renewable sources such as wind, solar, small hydro and biomass, despite of their significant resources in Russia. The main target of this project is to consider opportunities to apply renewable energy production in the North-West Federal Region of Russia to partly solve the above mentioned problems in the energy system.
Resumo:
Pumppauksessa arvioidaan olevan niin teknisesti kuin taloudellisestikin huomattavia mahdollisuuksia säästää energiaa. Maailmanlaajuisesti pumppaus kuluttaa lähes 22 % sähkö-moottorien energiantarpeesta. Tietyillä teollisuudenaloilla jopa yli 50 % moottorien käyttämästä sähköenergiasta voi kulua pumppaukseen. Jäteveden pumppauksessa pumppujen toiminta perustuu tyypillisesti on-off käyntiin, jolloin pumpun ollessa päällä se käy täydellä teholla. Monissa tapauksissa pumput ovat myös ylimitoitettuja. Yhdessä nämä seikat johtavat kasvaneeseen energian kulutukseen. Työn teoriaosassa esitellään perusteet jätevesihuollosta ja jäteveden käsittelystä sekä pumppaussysteemin pääkomponentit: pumppu, putkisto, moottori ja taajuusmuuttaja. Työn empiirisessä osassa esitellään työn aikana kehitetty laskuri, jonka avulla voidaan arvioida energiansäästöpotentiaalia jäteveden pumppaussysteemeissä. Laskurilla on mandollista laskea energiansäästöpotentiaali käytettäessä pumpun tuoton ohjaustapana pyörimisnopeuden säätöä taajuusmuuttajalla on-off säädön sijasta. Laskuri ilmoittaa optimaalisimmanpumpun pyörimisnopeuden sekä ominaisenergiankulutuksen. Perustuen laskuriin, kolme kunnallista jätevedenpumppaamoa tutkittiin. Myös laboratorio-testitsuoritettiin laskurin simuloimiseksi sekä energiansäästöpotentiaalin arvioimiseksi. Tutkimukset osoittavat, että jätevedenpumppauksessa on huomattavia mandollisuuksia säästää energiaa pumpun pyörimisnopeutta pienentämällä. Geodeettisen nostokorkeuden ollessa pieni, voidaan energiaa säästää jopa 50 % ja pitkällä aikavälillä säästö voi olla merkittävä. Tulokset vahvistavat myös tarpeen jätevedenpumppaussysteemien toiminnan optimoimiseksi.
Resumo:
This master’s thesis handles an operating model for an electric equipment supplier conducted sale oriented energy audit for pumping, fan and other motor applications at power plants. The study goes through the largest factors affecting internal electricity use at a power plant, finds an energy audit –like approach for the basis of information gathering and presents the information needed for conducting the analysis. The model is tested in practice at a kraft recovery boiler of a chemical pulping mill. Targets chosen represent some of the largest electric motor applications in the boiler itself and in its fuel handling. The energy saving potential of the chosen targets is calculated by simulating the energy consumption of the alternatives for controlling the targets, and thereafter combining the information with the volume flow duration curve. Results of the research are somewhat divaricated, as all the information needed is not available in the automation system. Some of the targets could be simulated and their energy saving potential calculated quite easily. At some of the targets chosen the monitoring was not sufficient enough for this and additional measurements would have been needed to base the calculations on. In traditional energy audits, energy efficiency of pump and fan applications is not necessarily examined. This means that there are good possibilities for developing the now presented targeted energy audit procedure basis further.
Resumo:
The main purpose of this thesis is to measure and evaluate how accurately the current energy saving calculation in ABB’s new variable speed drive ACS850 works. The main topic of this thesis is energy-efficiency parameters. At the beginning of this thesis centrifugal pump, squirrel cage motor and variable speed drive, including some equations related to them, are being introduced. Also methods of throttling control and variable speed drive control of centrifugal pumps are being introduced. These subjects are introduced because the energy saving calculation in ACS850 is related to the centrifugal pumps usually driven by squirrel cage motors. The theory also includes short section about specific energy of pumping. Before measurements the current energy saving calculation of ACS850 is being introduced and analyzed. The measurements part includes introduction of measuring equipment, measurement results, summary and analysis of the measurements. At the end of this thesis a proposal for an improvement to the current energy saving calculation is being introduced and few proposals are made for new energy-efficiency parameters, which could be added to variable speed drives. At the end are also thoughts
Resumo:
In recent years the environmental issues and the energy saving have become increasingly import in modern society where industry is the major emission factor and energy consumer. Generally, most of the total energy consumption is caused by electrical drives used in industrial applications and thus improving the performance of electrical drives give an opportunity to improve the energy efficiency. In this Master Thesis improving the energy efficiency in different electrical drives is clarified with different cases: regenerative braking in the electric grid or recovery of the braking energy into an energy storage. In addition, as an example, the energy consumption of an elevator is analyzed by measurements. From these measurement results it can be estimated how much the share of the standby energy consumption is from the total energy consumption and how much regenerative energy is available. The latter part of the thesis concentrates on determination of the properties of lithium iron phosphate battery with measurements.