987 resultados para Drill string vibrations
Resumo:
We construct a classical nonrelativistic string model in 3+1 dimensions. The model contains a spurion tensor field that is responsible for the noncommutative structure of the model. Under double-dimensional reduction the model reduces to the exotic nonrelativistic particle in 2+1 dimensions.
Resumo:
We show that the symmetries of effective D-string actions in constant dilaton backgrounds are directly related to homothetic motions of the background metric. In the presence of such motions, there are infinitely many nonlinearly realized rigid symmetries forming a loop (or looplike) algebra. Near horizon (antideSitter) D3 and D1+D5 backgrounds are discussed in detail and shown to provide 2D interacting field theories with infinite conformal symmetry.
Resumo:
New results on the theory of constrained systems are applied to characterize the generators of Noethers symmetry transformations. As a byproduct, an algorithm to construct gauge transformations in Hamiltonian formalism is derived. This is illustrated with two relevant examples.
Resumo:
We derive the back reaction on the gravitational field of a straight cosmic string during its formation due to the gravitational coupling of the string to quantum matter fields. A very simple model of string formation is considered. The gravitational field of the string is computed in the linear approximation. The vacuum expectation value of the stress tensor of a massless scalar quantum field coupled to the string gravitational field is computed to one loop order. Finally, the back-reaction effect is obtained by solving perturbatively the semiclassical Einsteins equations.
Resumo:
An analysis of cosmic string breaking with the formation of black holes attached to the ends reveals a remarkable feature: the black holes can be correlated or uncorrelated. We find that, as a consequence, the number-of-states enhancement factor in the action governing the formation of uncorrelated black holes is twice the one for a correlated pair. We argue that when an uncorrelated pair forms at the ends of the string, the physics involved is more analogous to thermal nucleation than to particle-antiparticle creation. Also, we analyze the process of intercommuting strings induced by black hole annihilation and merging. Finally, we discuss the consequences for grand unified strings. The process whereby uncorrelated black holes are formed yields a rate which significantly improves over those previously considered, but still not enough to modify string cosmology. 1995 The American Physical Society.
Resumo:
It is shown that the world volume field theory of a single D3-brane in a supergravity D3-brane background admits finite energy, and non-singular, Abelian monopoles and dyons preserving 1/2 or 1/4 of the N=4 supersymmetry and saturating a Bogomolnyi-type bound. The 1/4 supersymmetric solitons provide a world volume realization of string-junction dyons. We also discuss the dual M-theory realization of the 1/2 supersymmetric dyons as finite tension self-dual strings on the M5-brane, and of the 1/4 supersymmetric dyons as their intersections.
Resumo:
The scalar sector of the effective low-energy six-dimensional Kaluza-Klein theory is seen to represent an anisotropic fluid composed of two perfect fluids if the extra space metric has a Euclidean signature, or a perfect fluid of geometric strings if it has an indefinite signature. The Einstein field equations with such fluids can be explicitly integrated when the four-dimensional space-time has two commuting Killing vectors.
Resumo:
Whole-body vibration training improves strength and can increase maximal oxygen consumption ([·V]O(2max)). No study has compared the metabolic demand of synchronous and side-alternating whole-body vibration. We measured [·V]O₂ and heart rate during a typical synchronous or side-alternating whole-body vibration session in 10 young female sedentary participants. The 20-min session consisted of three sets of six 45-s exercises, with 15 s recovery between exercises. Three conditions were randomly tested on separate days: synchronous at 35 Hz and 4 mm amplitude, side-alternating at 26 Hz and 7.5 mm amplitude (peak acceleration matched at 20 g in both vibration conditions), and no vibrations. Mean [·V]O₂ (expressed as %[·V]O(2max)) did not differ between conditions: 29.7 ± 4.2%, 32.4 ± 6.5%, and 28.7 ± 6.7% for synchronous, side-alternating, and no vibrations respectively (P = 0.103). Mean heart rate (% maximal heart rate) was 65.6 ± 7.3%, 69.8 ± 7.9%, and 64.7 ± 5.6% for synchronous, side-alternating, and no vibrations respectively, with the side-alternating vibrations being significantly higher (P = 0.019). When analysing changes over exercise sessions, mean [·V]O₂ was higher for side-alternating (P < 0.001) than for synchronous and no vibrations. In conclusion, side-alternating whole-body vibration elicits higher heart rate responses than synchronous or no vibrations, and could elevate [·V]O₂, provided the session lasts more than 20 min.
Resumo:
AIM: This study evaluates the effect of front suspension (FS) and dual suspension (DS) mountain-bike on performance and vibrations during off-road uphill riding. METHODS: Thirteen male cyclists (27+/-5 years, 70+/-6 kg, VO(2max)59+/-6 mL.kg(-1).min(-1), mean+/-SD) performed, in a random sequence, at their lactate threshold, an off-road uphill course (1.69 km, 212 m elevation gain) with both type of bicycles. Variable measured: a) VO(2) consumption (K4b2 analyzer, Cosmed), b) power output (SRM) c) gain in altitude and d) 3-D accelerations under the saddle and at the wheel (Physilog, EPFL, Switzerland). Power spectral analy- sis (Fourier) was performed from the vertical acceleration data. RESULTS: Respectively for the FS and DS mountain bike: speed amounted to 7.5+/-0.7 km.h(-1) and 7.4+/-0.8 km.h(-1), (NS), energy expenditure 1.39+/-0.16 kW and 1.38+/-0.18, (NS), gross efficiency 0.161+/-0.013 and 0.159+/-0.013, (NS), peak frequency of vibration under the saddle 4.78+/-2.85 Hz and 2.27+/-0.2 Hz (P<0.01) and median-frequency of vertical displacements of the saddle 9.41+/-1.47 Hz and 5.78+/-2.27 Hz (P<0.01). CONCLUSION: Vibrations at the saddle level of the DS bike are of low frequencies whereas those of the FS bike are mostly of high frequencies. In the DS bike, the torque produced by the cyclist at the pedal level may generate low frequency vibrations. We conclude that the DS bike absorbs more high frequency vibrations, is more comfortable and performs as well as the FS bicycle.
Resumo:
Abstract: Background Stoma closure has been associated with a high rate of surgical site infection (SSI) and the ideal stoma-site skin closure technique is still debated. The aim of this study was to compare the rate of SSI following primary skin closure (PC) versus a skin-approximating, subcuticular purse-string closure (APS). Methods All consecutive patients undergoing stoma closure between 2002 and 2007 by two surgeons at a single tertiary-care institution were retrospectively assessed. Patients who had a new stoma created at the same site or those without wound closure were excluded. The end point was SSI, determined according to current CDC guidelines, at the stoma closure site and/or the midline laparotomy incision. Results There were 61 patients in the PC group (surgeon A: 58 of 61) and 17 in the APS group (surgeon B: 16 of 17). The two groups were similar in baseline and intraoperative characteristics, except that patients in the PC group were more often diagnosed with benign disease (p = 0.0156) and more often had a stapled anastomosis (p = 0.002). The overall SSI rate was 14 of 78 (18%). All SSIs occurred in the PC group (14 of 61 vs. 0 of 17, p = 0.03). Conclusions Our study suggests that a skin-approximating closure with a subcuticular purse-string of the stoma site leads to less SSI than a primary closure. Randomized studies are needed to confirm our findings and assess additional end points such as healing time, cost, and patient satisfaction.
Resumo:
OBJECTIVE: : Plunging when drilling can be a detrimental factor in patient care. There is, although, a general lack of information regarding the surgeon's performance in this skill. The aim of this study was to determine the effect that using sharp or blunt instruments had on the drill bit's soft tissue penetration, using a simulator. MATERIALS AND METHODS: : Surgeons taking part in an International Trauma Course were invited to participate. Two groups were defined: experienced and inexperienced surgeons. Twelve holes were drilled in the following order: 3 holes with a sharp drill bit in normal bone (SNB), 3 holes with a sharp drill bit in osteoporotic bone (SOB), 3 holes with a blunt drill bit in normal bone, and 3 holes with a blunt drill bit in osteoporotic bone. Mean values and Student t tests were used for statistical analysis. RESULTS: : Thirty-seven surgeons participated, 20 experienced and 17 inexperienced surgeons. Mean plunging depths for SNB, SOB, blunt drill bit in normal bone, and blunt drill bit in osteoporotic bone were, respectively, 5.1, 5.4, 21.1, and 13.9 mm for experienced surgeons and 7.6, 7.7, 22, and 15.9 mm for inexperienced surgeons. Drilling with SNB and with SOB was statistically different, with inexperienced surgeons plunging 2.5 mm (P = 0.31) and 2.6 mm (P = 0.042) deeper, respectively. There was a difference (P < 0.001) between sharp and blunt drill bits in all drilling conditions for both the groups. CONCLUSIONS: : Our study showed a significant difference in plunging depth when sharp or bunt drill bit was being used. Surgeons, regardless of their experience level, penetrate over 20 mm in normal bone and over 10 mm in osteoporotic bone.