975 resultados para Dot-com bubble


Relevância:

20.00% 20.00%

Publicador:

Resumo:

A Dot-ELISA using a measles virus (MV) antigen obtained by sodium deoxycholate treatment was standardized and evaluated for IgM and IgG antibody detection in measles patients and measles-vaccinated subjects. A total of 192 serum samples were studied, comprising 47 from patients with acute and convalescent measles, 55 from 9-month old children prior to measles vaccination and 41 from children of the same age after vaccination, and 49 from patients with unrelated diseases. The diagnostic performances of the IgG Dot-ELISA and IgG immuno fluorescence test (IFT) were found to be close, varying from 0.97 to 1.00 in sensitivity and the specificities were maximum (1.00). Nevertheless, the sensitivity of the IgM Dot-ELISA (0.85) was higher than that (0.63) of the IgM IFT, although both assays had comparably high (1.00) specificities. The IgM Dot-ELISA in particular proved to be more sensitive in relation to other assays studied by revealing antibodies in 80.0% (12/15) of vaccinated children on the 15th day after immunization. In contrast the IgM IFT, failed to detect antibodies in the same group of vaccinated children. The stability of the MV antigen was longer than that of the IFT antigen, and the reproducibility of the Dot-Elisa was satisfactory.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The alkaline soluble Trypanosoma cruzi epimastigote antigen (ASEA) was assessed in dot-ELISA for the diagnosis of Chagas' disease. Serum samples (355) from chagasic and non-chagasic patients were studied, and IgG antibodies to ASEA were found in all patients with chronic Chagas' disease. In non-chagasic patients 95.6% were negative, except for those with leishmaniasis (visceral and mucocutaneous), and some patients from control group reacted in low titers. The data indicate that dot-ELISA using ASEA is suitable for seroepidemiologic surveys to be employed in endemic areas for Chagas' disease.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In order to improve the diagnosis of human leptospirosis, we standardized the dot-ELISA for the search of specific IgM antibodies in saliva. Saliva and serum samples were collected simultaneously from 20 patients with the icterohemorrhagic form of the disease, from 10 patients with other pathologies and from 5 negative controls. Leptospires of serovars icterohaemorrhagiae, canicola, hebdomadis, brasiliensis and cynopteri grown in EMJH medium and mixed together in equal volumes, were used as antigen at individual protein concentration of 0.2 µg/µl. In the solid phase of the test we used polyester fabric impregnated with N-methylolacrylamide resin. The antigen volume for each test was 1µl, the saliva volume was 8 µl, and the volume of peroxidase-labelled anti-human IgM conjugate was 30 µl. A visual reading was taken after development in freshly prepared chromogen solution. In contrast to the classic nitrocellulose membrane support, the fabric support is easy to obtain and to handle. Saliva can be collected directly onto the support, a fact that facilitates the method and reduces the expenses and risks related to blood processing.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A dot-enzyme-linked immunosorbent assay (Dot-ELISA) for pneumococcal antigen detection was standardized in view of the need for a rapid and accurate immunodiagnosis of acute pneumococcal pneumonia. A total of 442 pleural fluid effusion samples (PFES) from children with clinical and laboratory diagnoses of acute bacterial pneumonia, plus 38 control PFES from tuberculosis patients and 20 negative control serum samples from healthy children were evaluated by Dot-ELISA. The samples were previously treated with 0.1 M EDTA pH 7.5 at 90°C for 10 min and dotted on nitrocellulose membrane. Pneumococcal omniserum diluted at 1:200 was employed in this assay for antigen detection. When compared with standard bacterial culture, counterimmunoelectrophoresis and latex agglutination techniques, the Dot-ELISA results showed relative indices of 0.940 to sensitivity, 0.830 to specificity and 0.760 to agreement. Pneumococcal omniserum proved to be an optimal polyvalent antiserum for the detection of pneumococcal antigen by Dot-ELISA. Dot-ELISA proved to be a practical alternative technique for the diagnosis of pneumococcal pneumonia.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Human schistosomiasis, caused by Schistosoma mansoni, is highly prevalent in Brazil and usually diagnosed by time consuming stool analysis. Serological tests are of limited use in this disease, mainly for epidemiological studies, showing no discrimination between previous contact with the parasite and active infections. In the present study, we standardized and compared a Dot-ELISA for IgM and IgG antibodies against S. mansoni antigens from eggs and worms with a routine IgG and IgM immunofluorescence assay using similar antigens, in the study of sera from 27 patients who had quantified egg stool excretion. The positivity obtained for IgG Dot-ELISA was 96.3% and 88.9% for IgM Dot-ELISA with worm antigen and 92.6% and 90.9% with egg antigen. The IFI presented similar positivities using worm antigen, 92.6% (IgG) and 96.3% (IgM),and lower results with egg antigen, 77.8% (IgG and IgM). The patients studied were divided into two groups according to their egg excretion, with greater positivity of serological tests in higher egg excreters. When comparing the quantitative egg excretion and the serological titers of the patients, we detected a correlation only with IgM Dot-ELISA, with r=0.552 (p=0.0127). These data show that Dot-ELISA can be used for the detection of specific antibodies against S. mansoni in sera from suspected patients or in epidemiological studies and, with further purification of egg antigen and larger samples, IgM Dot-ELISA could be a possible tool for rough estimates of parasite burden in epidemiological studies.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A Dot enzyme-linked immunosorbent assay (Dot-ELISA) was standardized and evaluated for the serodiagnosis of human toxoplasmosis. Out of 538 serum samples tested by the immunofluorescence test for toxoplasmosis (IFAT-IgG) as reference test, 183 (34%) were positive at cut off 1:16 and 192 (36%) were positive for Dot-ELISA-IgG at cut-off 1:256. For Dot-ELISA, co-positivity was 0.94, co-negativity 0.94 and concordance 0.88 in relation to IFAT-IgG. These results suggest the usefulness of Dot-ELISA (cut-off titer of 1:256) for the serodiagnosis of human toxoplasmosis. The main advantage of this technique is simplicity, positive test can be visually identified (colored precipitate). It does not require a special equipment and it can be used as a qualitative test to screen large numbers of samples or as a quantitative assay to determine end-point titration of individual sera.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A dot-ELISA was developed for the detection of antibodies in CSF in the immunologic diagnosis of human neurocysticercosis, using antigen extracts of the membrane and scolex of Cysticercus cellulosae (M+S-Cc) and, alternately, membrane (M) and vesicular fluid (VF) of Cysticercus longicollis (Cl) covalently bound to a new solid phase consisting of polyester fabric treated with N-methylol-acrylamide resin (dot-RT). The test was performed at room temperature, with reduced incubation times and with no need for special care in the manipulation of the support. The sensitivity rates obtained were 95.1% for antigen Cc and 97.6% for antigen Cl. Specificity was 90.6% when Cc was used, and 96.9% and 100% when M-Cl and VF-Cl were used, respectively. No significant differences in titer were observed between tests carried out with homologous and heterologous antigens. The low cost and easy execution of the dot-RT test using antigen extracts of Cysticercus longicollis indicate the test for use in the immunodiagnosis of human neurocysticercosis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

With the objective of standardizing a Dot Enzyme-Linked Immunosorbent Assay (Dot-ELISA) to detect antigens of fecal bacterial enteropathogens, 250 children, aged under 36 months and of both sexes, were studied; of which 162 had acute gastroenteritis. The efficacy of a rapid screening assay for bacterial enteropathogens (enteropathogenic Escherichia coli "EPEC", enteroinvasive Escherichia coli "EIEC", Salmonella spp. and Shigella spp.) was evaluated. The fecal samples were also submitted to a traditional method of stool culture for comparison. The concordance index between the two techniques, calculated using the Kappa (k) index for the above mentioned bacterial strains was 0.8859, 0.9055, 0.7932 and 0.7829 respectively. These values express an almost perfect degree of concordance for the first two and substantial concordance for the latter two, thus enabling this technique to be applied in the early diagnosis of diarrhea in infants. With a view to increasing the sensitivity and specificity of this immunological test, a study was made of the antigenic preparations obtained from two types of treatment: 1) deproteinization by heating; 2) precipitation and concentration of the lipopolysaccharide antigen (LPS) using an ethanol-acetone solution, which was then heated in the presence of sodium EDTA

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Twenty-seven mycologically proven cases of paracoccidioidomycosis (PCM) were treated with itraconazole (100-200 mg/day in month 1 and 100 mg/day until month 6-8) and evaluated clinically and serologically, up to 3.5 years post-therapy, using Dot-blot and ELISA for measuring the titers of IgG, IgA and IgM anti-P. brasiliensis antibodies and Western-blot for determining IgG, IgA and IgM antibodies against the antigen components of the fungus. Before treatment, 81.5% (Dot-blot) and 84% (ELISA) of the patients presented elevated IgG anti-P. brasiliensis antibody titers which dropped slightly with treatment. On the other hand, the percentages of pre-treatment high-titered sera for IgA and IgM anti-P.brasiliensis were lower (5l.9% and 5l.8%: Dot-blot; 16.5 and 36%: ELISA, respectively) but the titers tended to become negative more frequently with treatment. Prior to treatment, the percentages of positivity for IgG, IgA and IgM anti-P.brasiliensis antibodies in Western-blot were 96%, 20.8% and 41.6%, respectively. Antigens with molecular weights varying from 16-78 kDa, from 21-76 kDa and from 27-78 kDa were reactive for IgG, IgA and IgM antibodies, respectively. The most frequently reactive antigenic components had molecular weights of 27, 33 and 43 kDa for IgG, and 70 for IgA and IgM antibodies. During the period of study, the patients responded well to treatment. The present data confirm the diversity and complexity of the humoral response in PCM, and the importance of utilizing different serological tests to detect IgG, IgA and IgM anti-P. brasiliensis antibodies

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of the present study was to standardize and evaluate dot-Enzyme linked immunosorbent assay (Dot-ELISA), a simple and rapid test for the detection of cysticercus antibodies in the serum for the diagnosis of neurocysticercosis (NCC). The antigen used in the study was a complete homogenate of Cysticercus cellulosae cysts obtained from infected pigs and dotted on to nitrocellulose membrane. Test sera were collected from the patients of NCC, and control sera from patients with other diseases and healthy students and blood donors of the Jawaharlal Institute of Postgraduate Medical Education and Research (JIPMER) Hospital, Pondicherry, during a study period from 2001 to 2003. Dot-ELISA detected antibodies in 14 of 25 (56%) in clinically suspected cases of NCC, 13 of 23 (56.5%) in CT/MRI proven cases of NCC and 2 of 25 (8%) each in non-cysticercal CNS infection controls and healthy controls. The test showed a sensitivity of 56.25%, specificity of 92%, positive predictive value of 87.09%, and negative predictive value of 70.76%. Results of the present study shows that the Dot-ELISA as a simple test can be used in the field or poorly equipped laboratories for diagnosis of NCC .

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of the present study is to evaluate cyst wall and protoscolex as an alternate source of antigen in serodiagnosis of cystic echinococcosis (CE). A total of 90 blood samples, 30 each of confirmed CE cases, disease controls and healthy controls were collected. Dot-ELISA using cyst wall, protoscolex and cyst fluid were used to demonstrate anti-hydatid antibodies. The sensitivity of Dot-ELISA using cyst wall, protoscolex and cyst fluid was 96.66%, 86.66% and 93.33% respectively and the specificity of the assay was 70% for Dot-ELISA using cyst fluid, protoscolex and cyst wall antigens. Results of the present study show that cyst wall and protoscolex can also be an useful source of antigen in detection of hydatid antibodies in the serodiagnosis of CE.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this study was to estimate the frequency of human toxocariasis in Cauday district, Cajamarca, Peru, using a dot-ELISA test. From June to October 2005, a total of 256 adult subjects were studied. Blood samples were collected for serology by a dot-ELISA test and for hematological examination. Parasitological examination was also carried out in stool samples to check cross-reactions in the dot-ELISA. The frequency observed was 44.92%, with a significant higher proportion of positivity in male subjects. From subjects with positive serology, 45.6% had respiratory symptoms, 40.44% abdominal pain, 32.35% hepatic symptoms, 14.7% cutaneous signs, 13.23% ocular manifestations, 43.38% eosinophilia, and all of these were statistically associated to serology. Among the population evaluated, 90.23% (231/256) were parasitized. From subjects with positive serology, 92.17% had at least one intestinal parasite and the most frequent were: Blastocystis hominis (68.38%), Giardia lamblia (28.68%), Hymenolepis nana (20.0%), Ascaris lumbricoides (15.65%), Entamoeba histolytica/E. dispar (13.24%), Cyclospora cayetanensis (4.41%), Cryptosporidium sp. (1.47%), Enterobius vermicularis (0.87%), Strongyloides stercoralis (0.87%), Taenia sp. (0.87%), and Trichuris trichiura (0.87%). The rate of false positives in the dot-ELISA test was improved by serum absorption each with A. suum antigens, with a decrease of cross-reactions. In conclusion, human toxocariasis is highly frequent in this population and some risk factors like dog/cat ownership, presence of pets within house, and previous history of geophagia were observed in the present study.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dacron and nitrocellulose were evaluated as matrices for the dot enzyme linked immunosorbent assay (dot-ELISA) for schistosomiasis and compared to indirect immunofluorescence (IMF). Titration of sera from 18 schistosomiasis patients against soluble worm antigen preparation (SWAP) was carried out and sera from healthy individuals from non-endemic areas were used as controls. The IMF was less sensitive than the dot-ELISAs, although the difference was not statistically significant (p > 0.05). The dot-ELISA based on nitrocellulose was as sensitive as that using dacron. Stability did not differ between nitrocellulose and dacron. Specificity was lower when dacron was used than when nitrocellulose was used, although the difference was not statistically significant (p > 0.05). In conclusion, this work showed that nitrocellulose and dacron performed similarly in dot-ELISA, suggesting that they may be used alternatively in population surveillance in endemic areas.