951 resultados para Denture, Partial, Immediate


Relevância:

80.00% 80.00%

Publicador:

Resumo:

The main objective of this paper was to discuss the importance of the reverse planning as guidance to surgical procedures on immediate loading implant-retained prosthesis, presenting a case report. Such design aims to define anchorage orientation after determination of prosthetic design. This is quite important because the possibility of success of cases with this kind of planning may achieve high levels of satisfaction. Another important aspect is the possibility of fast and definitive restoration of patients’ function and aesthetics

Relevância:

80.00% 80.00%

Publicador:

Resumo:

An appropriate design of a prosthetic rehabilitation should not impute the restoration of occlusal vertical dimension (OVD) to new prostheses, at the risk of the patient does not adapt to a new condition, since a certain amount of time is often necessary for adaptation to a new OVD. This article performed prosthetic rehabilitation with an overlay provisional removable partial denture prior to definitive treatment because the patient showed a considerable decrease in the OVD. Three techniques for OVD determination were used. It is possible to conclude that the use of interim removable partial dentures is of great importance at the beginning of the rehabilitation treatment in order to adapt the patient to a new occlusal condition.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

An appropriate design of a prosthetic rehabilitation should not impute the restoration of occlusal vertical dimension (OVD) to new prostheses, at the risk of the patient does not adapt to a new condition, since a certain amount of time is often necessary for adaptation to a new OVD. This article performed prosthetic rehabilitation with an overlay provisional removable partial denture prior to definitive treatment because the patient showed a considerable decrease in the OVD. Three techniques for OVD determination were used. It is possible to conclude that the use of interim removable partial dentures is of great importance at the beginning of the rehabilitation treatment in order to adapt the patient to a new occlusal condition.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Objective: To perform a long-term clinical evaluation of the periodontium of removable parti al denture (RPD) wearers, comparing the direct pillar teeth of tooth-supported and toothtissue supported RPDs. Method: Fifty patients with mean age of 45 years were enrolled in the study. The individuals were examined by a single examiner at the moment of denture installation and after 3, 6, 9 and 12 months. In each exam, the following parameters were verified: gingival recession (GR), probing depth (PD), plaque index (PI), gingival index (GI) e amount kerati nized mucosa (KM). All patients received oral hygiene instructions and prophylaxis and, when necessary, scaling and root planing. An analysis from the confidence interval was done to evaluate the endpoints regarding the type of denture in the direct pillar group. Results: The tooth-tissue supported dentures showed significantly higher GR, GI and PI values, and significantly lower KM values. Over time, neither of the types of denture presented statistically significant difference from the initial to the final examination for the parameters GR, PD, KM and GI, while the PI was significant only for the tooth-supported dentures. Conclusion: Pillar teeth adjacent to free ends presented a less favorable periodontal conditi on than the pillar teeth adjacent to intercalated spaces. However, the use of RPD did not aggravate the initial condition, after a follow-up period of 12 months. The findings of the study indicate that, within 1 year, there were no significant differences between the direct pillars of the toothsupported and tooth-ti ssue supported dentures, and suggest the need of professional follow up for a longer period.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Objective: To perform a long-term clinical evaluation of the periodontium of removable parti al denture (RPD) wearers, comparing the direct pillar teeth of tooth-supported and toothtissue supported RPDs. Method: Fifty patients with mean age of 45 years were enrolled in the study. The individuals were examined by a single examiner at the moment of denture installation and after 3, 6, 9 and 12 months. In each exam, the following parameters were verified: gingival recession (GR), probing depth (PD), plaque index (PI), gingival index (GI) e amount kerati nized mucosa (KM). All patients received oral hygiene instructions and prophylaxis and, when necessary, scaling and root planing. An analysis from the confidence interval was done to evaluate the endpoints regarding the type of denture in the direct pillar group. Results: The tooth-tissue supported dentures showed significantly higher GR, GI and PI values, and significantly lower KM values. Over time, neither of the types of denture presented statistically significant difference from the initial to the final examination for the parameters GR, PD, KM and GI, while the PI was significant only for the tooth-supported dentures. Conclusion: Pillar teeth adjacent to free ends presented a less favorable periodontal conditi on than the pillar teeth adjacent to intercalated spaces. However, the use of RPD did not aggravate the initial condition, after a follow-up period of 12 months. The findings of the study indicate that, within 1 year, there were no significant differences between the direct pillars of the toothsupported and tooth-ti ssue supported dentures, and suggest the need of professional follow up for a longer period.

Relevância:

50.00% 50.00%

Publicador:

Resumo:

The purposes of this study were to photoelastically measure the biomechanical behavior of 4 implants retaining different cantilevered bar mandibular overdenture designs and to compare a fixed partial denture (FPD). A photoelastic model of a human edentulous mandible was fabricated, which contained 4 screw-type implants (3.75 x 10 mm) embedded in the parasymphyseal area. An FPD and 3 overdenture designs with the following attachments were evaluated: 3 plastic Hader clips, 1 Hader clip with 2 posterior resilient cap attachments, and 3 ball/O-ring attachments. Vertical occlusal forces of 100 N were applied between the central incisor and unilaterally to the right and left second premolars and second molars. Stresses that developed in the supporting structure were monitored photoelastically and recorded photographically. The results showed that the anterior loading, the overdenture with 3 plastic Hader clips, displayed the largest stress concentration at the medium implant. With premolar loading, the FPD and overdenture with 3 plastic Hader clips displayed the highest stresses to the ipsilateral terminal implant. With molar loading, the overdenture with 3 ball/O-ring attachments displayed the most uniform stress distribution in the posterior edentulous ridge, with less overloading in the terminal implant. It was concluded that vertical forces applied to the bar-clip overdenture and FPD created immediate stress patterns of greater magnitude and concentration on the ipsilateral implants, whereas the ball/O-ring attachments transferred minimal stress to the implants. The increased cantilever in the FPD caused the highest stresses to the terminal implant.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

To evaluate the pattern of maxillary complete denture movement during chewing for free-end removable partial dentures (RPD) wearers, compared to maxillary and mandibular complete denture wearers. Eighteen edentulous participants (group I) and 10 volunteers with bilateral posterior edentulous mandibles (group II) comprised the sample. Measures of mean denture movement and its variability were obtained by a kinesiographic instrument K6-I Diagnostic System, during the mastication of bread and a polysulphide block. Data were analysed using two-way anova (alpha = 0.05). Upper movement during chewing was significantly lower for group II, regardless of the test food. The test food did not influence the vertical or lateral position of the denture bases, but more anterior dislocation was found when polysulphide blocks were chewed. Group II presented lower intra-individual variability for the vertical axis. Vertical displacement was also more precise with bread as a test food. It can be concluded that mandibular free-end RPD wearers show smaller and more precise movements than mandibular complete denture wearers.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Introduction: Although the use of local flaps in conservative breast surgery (CBS) reconstruction is a reliable technique, little information has been available regarding outcome following the use of perforator flaps. The purpose of this study is to analyze the feasibility, surgical planning and outcome following CBS reconstruction with intercostal artery perforator (ICAP) flap. Patients/methods: Thirteen patients underwent CBS reconstructions with an ICAP flap. These flaps were raised from adjacent tissue located on the lateral and thoracic region and based on perforators originating from the costal and muscular segment of the intercostal vessels. The technique was indicated in patients with small/moderate volume breasts. Results: Mean time of follow-up was 32 months. Flap complications were evaluated and information on patient satisfaction were collected. 61.5 percent had tumors located in the lower-outer quadrants and 69.2 percent had tumors measuring 2 cm or less (T1). Complications occurred in 3 patients (23%), including wound dehiscence in 2 patients and fat necrosis in one. All cases were treated by conservative approach with a good result. No flap loss or wound infection were reported. 90 percent were either satisfied or very satisfied with their result. Conclusion: The ICAP flap is a reliable technique for immediate CBS reconstruction. The technique is advantageous because it does not require the use of muscle transfer, with minimum donor site morbidity. Success depends on patient selection, coordinated planning with the oncological surgeon and careful intra-operative management. (C) 2011 Elsevier Ltd. All rights reserved.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Some studies have evaluated the salivary levels of mutans streptococci (MS) in removable partial denture (RPD) users. Saliva samples (2.0 mL) were obtained from 31 patients in six periods: (T0): immediately before installation of RPD; (T8): 8 days after T0; (T48): 48 days after T0; (T92): 92 days after T0; (T140): 140 days after T0 and (T189): 189 days after T0. The samples were vortexed and serially diluted from 10(-1) to 10(-6) in 0.05 m phosphate buffer (pH 7.4). From each dilution, 0.025 mL was plated on Mitis Salivarius Bacitracin (MSB). The plates were incubated in 5% CO2 at 37 degreesC for 72 h. There was an increase (t -test, P < 0.05) in the number of MS between periods T0 and T48 (mean/s.d., CFU mL(-1) of saliva): T0: 2.26/4.43 x 10(6) and T48: 0.47/1.48 x 10(8) . After this, intensive treatment with CHX was accomplished in 29 patients. Saliva samples were obtained after treatment in four periods: (T24 h): 24 h after T0; (T14): 14 days after T24 h; (T28): 28 days after T24 h, and (T63): 63 days after T24 h. The number of MS in saliva did not decrease (t -test, P > 0.05). A new CHX formulation was applied in 15 patients. Saliva samples were obtained in periods: (T0): before new CHX application; (T24 h): 24 h after T0 and (T82): 82 days after T0. The new CHX reduced MS levels in saliva: (mean/s.d., CFU mL(-1) of saliva): T0: 6.64/8.47 x 10(6) and T24 h: 3.2/4.27 x 10(5) (sign rank, P < 0.05). In conclusion, there was a significant increase in the number of MS in saliva after the installation of RPD. The intensive treatment with a properly formulated CHX was effective in the reduction of MS, between 24 h and 82 days after its application.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Interim restorations are frequently used in prosthodontic treatments. Many complex situations require the combination of fixed and removable partial prostheses. An appropriate interim restoration design that accurately implements the treatment plan is necessary to prepare the oral cavity for the prostheses, and to contribute to the preservation and health of remaining natural teeth, bone support, and gingival tissues. This report describes a modified technique for construction of interim restorations with a combination of fixed and removable partial prostheses. The technique consists of the construction of a milled fixed prosthesis and removable partial denture with metallic framework for use during extensive treatment, improving masticatory function and esthetics and preserving the periodontal health of supporting structures. This interim restoration can also serve as a template for the definitive restoration, allowing patient and dentist to evaluate appearance and function and helping to ensure the success of the definitive restoration.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The aim of this study was to evaluate the tendency of displacement of the supporting structures of the distal extension removable partial denture (DERPD) associated to the implant with different inclinations of alveolar ridge and implant localizations through a two-dimensional finite-element method. Sixteen mandibular models were fabricated, presenting horizontal, distally descending, distally ascending, or descending-ascending ridges. All models presented the left canine and were rehabilitated with conventional DERPD or implant-retained prosthesis with the ERA system. The models were obtained by the AutoCAD software and transferred to the finite-element software ANSYS 9.0 for analysis. A force of 50 N was applied on the cusp tips of the teeth, with 5 points of loading of 10 N. The results were visualized by displacement maps. For all ridge inclinations, the assembly of the DERPD with distal plate retained by an anterior implant exhibited the lowest requisition of the supporting structures. The highest tendency of displacement occurred in the model with distally ascending ridge with incisal rest. It was concluded that the association of the implant decreased the displacement of the DERPD, and the anterior positioning of the implant associated to the DERPD with the distal plate preserved the supporting structures for all ridges.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The aim of this study was to use two-dimensional finite element method to evaluate the displacement and stress distribution transmitted by a distal extension removable partial denture (DERPD) associated with an implant placed at different inclinations (0, 5, 15, and 30 degrees) in the second molar region of the edentulous mandible ridge. Six hemimandibular models were created: model A, only with the presence of the natural tooth 33; model B, similar to model A, with the presence of a conventional DERPD replacing the missing teeth; model C, similar to the previous model, with a straight implant (0 degrees) in the distal region of the ridge, under the denture base; model D, similar to model C, with the implant angled at 5 degrees in the mesial direction; model E, similar to model C, with the implant angled at 15 degrees in the mesial direction; and model F, similar to ME, with the implant angled at 30 degrees in the mesial direction. The models were created with the use of the AutoCAD 2000 program (Autodesk, Inc, San Rafael, CA) and processed for finite element analysis by the ANSYS 8.0 program (Swanson Analysis Systems, Houston, PA). The force applied was vertical of 50 N on each cusp tip. The results showed that the introduction of the RPD overloaded the supporting structures of the RPD and that the introduction of the implant helped to relieve the stresses of the mucosa alveolar, cortical bone, and trabecular bone. The best stress distribution occurred in model D with the implant angled at 5 degrees. The use of an implant as a support decreased the displacement of alveolar mucosa for all inclinations simulated. The stress distribution transmitted by the DERPD to the supporting structures was improved by the use of straight or slightly inclined implants. According to the displacement analysis and von Mises stress, it could be expected that straight or slightly inclined implants do not represent biomechanical risks to use.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Purpose: This study evaluated the influence of distal extension removable partial denture associated with implant in cases of different bone level of abutment tooth, using 2D finite element analysis.Materials and Methods: Eight hemiarch models were simulated: model A-presenting tooth 33 and distal extension removable partial denture replacing others teeth, using distal rest connection and no bone lost; model B-similar to model A but presenting distal guide plate connection; model C-similar to model A but presenting osseointegrated implant with ERA retention system associated under prosthetic base; model D-similar to model B but presenting osseointegrated implant as described in model C; models E, F, G, and H were similar to models A, B, C, and D but presenting reduced periodontal support around tooth 33. Using ANSYS 9.0 software, the models were loaded vertically with 50 N on each cusp tip. For results, von Mises Stress Maps were plotted.Results: Maximum stress value was encountered in model G (201.023 MPa). Stress distribution was concentrated on implant and retention system. The implant/removable partial denture association decreases stress levels on alveolar mucosa for all models.Conclusions: Use of implant and ERA system decreased stress concentrations on supporting structures in all models. Use of distal guide plate decreased stress levels on abutment tooth and cortical and trabecular bone. Tooth apex of models with reduced periodontal support presented increased stress when using distal rest. (Implant Dent 2011;20:192-201)

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The aim of this study was to describe the treatment used in an elderly patient presenting with bruxism and dental erosion, with good gingival health and bone support, but with decreased occlusal vertical dimension (OVD). The oral rehabilitation of elderly patients presenting with bruxism in association with tooth erosion has been a great challenge for dentists. The loss of OVD, the presence of occlusal instability and the absence of an effective anterior guide due excessive dental wear, can damage stomatognathic system (SS) biology, the function and the aesthetics. In the first treatment stage, an overlay removable partial denture (ORPD) was fabricated for the immediate re-establishment of function and aesthetics. After a 2-month follow up, with the patient presenting no symptoms, a second rehabilitation stage was accomplished, with fixed and removable prostheses. Oral rehabilitation with an ORPD was able to re-establish the SS biology, but a correct diagnosis and treatment plan are essential for success. The ORPD is a non-invasive and reversible restoring modality for general dentists that allow the re-establishment of the patient's immediate aesthetics and function at low cost.