961 resultados para Dental unit water lines


Relevância:

40.00% 40.00%

Publicador:

Resumo:

To ensure better concrete quality and long-term durability, there has been an increasing focus in recent years on the development of test methods for quality control of concrete. This paper presents a study to evaluate the effect of water accessible porosity and oven-dry unit weight on the resistance of concrete to chloride-ion penetration. Based on the experimental results and regression analyses, empirical relationships of the charge passed (ASTM C 1202) and chloride migration coefficient (NT Build 492) versus the water accessible porosity and oven dry unit weight of the concrete are established. Using basic physical properties of water accessible porosity and oven dry unit weight which can be easily determined, total charge passed and migration coefficient of the concrete can be estimated for quality control and for estimating durability of concrete.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Mycobacterium kansasii is a pulmonary pathogen that has been grown readily from municipal water, but rarely isolated from natural waters. A definitive link between water exposure and disease has not been demonstrated and the environmental niche for this organism is poorly understood. Strain typing of clinical isolates has revealed seven subtypes with Type 1 being highly clonal and responsible for most infections worldwide. The prevalence of other subtypes varies geographically. In this study 49 water isolates are compared with 72 patient isolates from the same geographical area (Brisbane, Australia), using automated repetitive unit PCR (Diversilab) and ITS RFLP. The clonality of the dominant clinical strain type is again demonstrated but with rep-PCR, strain variation within this group is evident comparable with other reported methods. There is significant heterogeneity of water isolates and very few are similar or related to the clinical isolates. This suggests that if water or aerosol transmission is the mode of infection, then point source contamination likely occurs from an alternative environmental source.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Collection :Europto series, 6

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The water loss behaviour of a clinical glass-ionomer dental cement has been studied with and without the addition of alkali metal chlorides. Dehydrating conditions were provided by placing specimens in a desiccator over concentrated sulphuric acid. Cements were prepared using either pure water or an aqueous solution of metal chloride (LiCl, NaCl, KCl) at 1.0 mol/dm(3). In addition, NaCl at 0.5 mol/dm(3) was also used to fabricate cements. Disc-shaped specimens of size 6 mm diameter x 2 mm thickness were made, six performulation, and cured at 37 degrees C for 1 hour They were then exposed to desiccating conditions, and the mass measured at regular intervals. All formulations were found to lose water in a diffusion process that equilibrated after approximately 3 weeks. Diffusion coefficients ranged from 2.27 (0.13) x 10(9) with no additive to 1.85 (0.07) x 10(9) m(2)/s with 1.0 mol/dm(3) KCl. For the salts, diffusion coefficients decreased in the order LiCl > NaCl > KCl. There was no statistically significant difference between the diffusion coefficients for 1.0 and 0.5 mol/dm(3) NaCl. For all salts at 1.0 mol/dm(3) and also additive-free cements, equilibrium losses were, with statistical limits, the same, ranging from 6.23 to 6.34%. On the other hand, 0.5 mol/dm(3) NaCl lost significantly more water 7.05%.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The water desorption behaviour of three different zinc oxide dental cements (two polycarboxylates, one phosphate) has been studied in detail. Disc-shaped specimens of each material were prepared and allowed to lose water by being subjected to a low humidity desiccating atmosphere over concentrated sulfuric acid. In all three cements, water loss was found to follow Fick's second law for at least 6 h (until M(t)/M(infinity) values were around 0.5), with diffusion coefficients ranging from 6.03 x 10(-8 )cm(2 )s(-1) (for the zinc phosphate) to 2.056 x 10(-7 )cm(2 )s(-1) (for one of the zinc polycarboxylates, Poly F Plus). Equilibration times for desorption were of the order of 8 weeks, and equilibrium water losses ranged from 7.1% for zinc phosphate to 16.9% and 17.4% for the two zinc polycarboxylates.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Water uptake and water loss have been studied in a commercial resin-modified glass-ionomer cement, Fuji II LC, under a variety of conditions. Uptake was generally non-Fickian, but affected by temperature. At room temperature, the equilibrium water uptake values varied from 2.47 to 2.78% whereas at low temperature (12 degrees C), it varied from 0.85 to 1.18%. Cure time affected uptake values significantly. Water uptake was much lower than in conventional glass-ionomer restorative cements exposed to water vapor. Loss of water under desiccating conditions was found to be Fickian for the first 5 h loss at both 22 and 12 degrees C. Diffusion coefficients were between 0.45 and 0.76 x 10( -7) cm(2)/s, with low temperature diffusion coefficients slightly greater than those at room temperature. Plotting water loss as percentage versus s(-(1/2)) allowed activation energies to be determined from the Arrhenius equation and these were found to be 65.6, 79.8, and 7.7 kJ/mol respectively for 30, 20, and 10 s cure times. The overall conclusion is that the main advantage of incorporating HEMA into resin-modified-glass-ionomers is to alter water loss behavior. Rate of water loss and total amount lost are both reduced. Hence, resin-modified glass-ionomers are less sensitive to water loss than conventional glass-ionomers.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Objectives: Acute lung injury and the acute respiratory distress syndrome are characterized by noncardiogenic pulmonary edema, which can be assessed by measurement of extravascular lung water. Traditionally, extravascular lung water has been indexed to actual body weight (mL/kg). Because lung size is dependent on height rather than weight, we hypothesized indexing to predicted body weight may be a better predictor of mortality in acute lung injury/acute respiratory distress syndrome.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Intensities and self-broadening coefficients are presented for about 460 of the strongest water vapour lines in the spectral regions 1400–1840 cm−1 and 3440–3970 cm−1 at room temperature, obtained from rather unique measurements using a 5-mm-path-length cell. The retrieved spectral line parameters are compared with those in the HITRAN database ver. 2008 and 2012 and with recent ab-initio calculations. Both the retrieved intensities and half-widths are on average in reasonable agreement with those in HITRAN-2012. Maximum systematic differences do not exceed 4% for intensities (1600 cm−1 band) and 7% for self-broadening coefficients (3600 cm−1 band). For many lines however significant disagreements were detected with the HITRAN-2012 data, exceeding the average uncertainty of the retrieval. In addition, water vapour line parameters for 5300 cm−1 (1.9 μm) band reported by us in 2005 were also compared with HITRAN-2012, and show average differences of 4–5% for both intensities and half-widths.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Since World War II, however, the term has increasingly referred to law enforcement operations, as a means to enforce trade sanctions, to prevent the movement of weapons of mass destruction (WMDs), and particularly in the Caribbean Sea, to prevent the smuggling of illicit drugs. Such ambiguity should allow flexibility when deciding whom should be targeted, as well as allowing states with veto powers in the UN Security Council, which may legitimately ship nuclear weapons and materials, to avoid being targeted as long as they do not export WMDs to rogue states or non-state groups or individuals.2 The ISPS Code was created under the auspices of the International Maritime Organization (IMO) and is part of the 1974 Safety of Life at Sea Convention (SOLAS) concerning the safety of merchant ships.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

40.00% 40.00%

Publicador:

Resumo:

This study determined the prevalence of cavitated caries lesions (CCL) and early childhood caries (ECC), and the contribution of some variables in children up to 36 months of age attending daycare centers in municipalities with different fluoride levels in the water supply: AFC (adequate fluoride content) and LFC (low fluoride content). After approval of the Ethics Committee, the parents were interviewed. The children were clinically examined using the same codes and criteria established by the WHO (World Health Organization) and the ADA (American Dental Association). Fisher's exact test (p<0.05) was applied for statistical analysis of data. The dmft indices calculated in the LFC and AFC municipalities were 0.57 and 0.68, respectively. Considering all children examined, 17.6% presented CCL and 33.8% ECC. The economic classification, mother's education level and duration of breastfeeding were considered statistically significant with regards to CCL prevalence. The age group, duration of the habit of drinking milk before bedtime and age at which oral hygiene started were considered statistically significant with regards to ECC prevalence.