887 resultados para Corrosión del acero
Resumo:
Corrosion of steel bars embedded in concrete has a great influence on structural performance and durability of reinforced concrete. Chloride penetration is considered to be a primary cause of concrete deterioration in a vast majority of structures. Therefore, modelling of chloride penetration into concrete has become an area of great interest. The present work focuses on modelling of chloride transport in concrete. The differential macroscopic equations which govern the problem were derived from the equations at the microscopic scale by comparing the porous network with a single equivalent pore whose properties are the same as the average properties of the real porous network. The resulting transport model, which accounts for diffusion, migration, advection, chloride binding and chloride precipitation, consists of three coupled differential equations. The first equation models the transport of chloride ions, while the other two model the flow of the pore water and the heat transfer. In order to calibrate the model, the material parameters to determine experimentally were identified. The differential equations were solved by means of the finite element method. The classical Galerkin method was employed for the pore solution flow and the heat transfer equations, while the streamline upwind Petrov Galerkin method was adopted for the transport equation in order to avoid spatial instabilities for advection dominated problems. The finite element codes are implemented in Matlab® . To retrieve a good understanding of the influence of each variable and parameter, a detailed sensitivity analysis of the model was carried out. In order to determine the diffusive and hygroscopic properties of the studied concretes, as well as their chloride binding capacity, an experimental analysis was performed. The model was successfully compared with experimental data obtained from an offshore oil platform located in Brazil. Moreover, apart from the main objectives, numerous results were obtained throughout this work. For instance, several diffusion coefficients and the relation between them are discussed. It is shown how the electric field set up between the ionic species depends on the gradient of the species’ concentrations. Furthermore, the capillary hysteresis effects are illustrated by a proposed model, which leads to the determination of several microstructure properties, such as the pore size distribution and the tortuosity-connectivity of the porous network. El fenómeno de corrosión del acero de refuerzo embebido en el hormigón ha tenido gran influencia en estructuras de hormigón armado, tanto en su funcionalidad estructural como en aspectos de durabilidad. La penetración de cloruros en el interior del hormigón esta considerada como el factor principal en el deterioro de la gran mayoría de estructuras. Por lo tanto, la modelización numérica de dicho fenómeno ha generado gran interés. El presente trabajo de investigación se centra en la modelización del transporte de cloruros en el interior del hormigón. Las ecuaciones diferenciales que gobiernan los fenómenos a nivel macroscópico se deducen de ecuaciones planteadas a nivel microscópico. Esto se obtiene comparando la red porosa con un poro equivalente, el cual mantiene las mismas propiedades de la red porosa real. El modelo está constituido por tres ecuaciones diferenciales acopladas que consideran el transporte de cloruros, el flujo de la solución de poro y la transferencia de calor. Con estas ecuaciones se tienen en cuenta los fenómenos de difusión, migración, advección, combinación y precipitación de cloruros. El análisis llevado a cabo en este trabajo ha definido los parámetros necesarios para calibrar el modelo. De acuerdo con ellas, se seleccionaron los ensayos experimentales a realizar. Las ecuaciones diferenciales se resolvieron mediante el método de elementos finitos. El método clásico de Galerkin se empleó para solucionar las ecuaciones de flujo de la solución de poro y de la transferencia de calor, mientras que el método streamline upwind Petrov-Galerkin se utilizó para resolver la ecuación de transporte de cloruros con la finalidad de evitar inestabilidades espaciales en problemas con advección dominante. El código de elementos finitos está implementado en Matlab® . Con el objetivo de facilitar la comprensión del grado de influencia de cada variable y parámetro, se realizó un análisis de sensibilidad detallado del modelo. Se llevó a cabo una campaña experimental sobre los hormigones estudiados, con el objeto de obtener sus propiedades difusivas, químicas e higroscópicas. El modelo se contrastó con datos experimentales obtenidos en una plataforma petrolera localizada en Brasil. Las simulaciones numéricas corroboraron los datos experimentales. Además, durante el desarrollo de la investigación se obtuvieron resultados paralelos a los planteados inicialmente. Por ejemplo, el análisis de diferentes coeficientes de difusión y la relación entre ellos. Así como también se observó que el campo eléctrico establecido entre las especies iónicas disueltas en la solución de poro depende del gradiente de concentración de las mismas. Los efectos de histéresis capilar son expresados por el modelo propuesto, el cual conduce a la determinación de una serie de propiedades microscópicas, tales como la distribución del tamaño de poro, además de la tortuosidad y conectividad de la red porosa.
Resumo:
La corrosión del acero es una de las patologías más importantes que afectan a las estructuras de hormigón armado que están expuestas a ambientes marinos o al ataque de sales fundentes. Cuando se produce corrosión, se genera una capa de óxido alrededor de la superficie de las armaduras, que ocupa un volumen mayor que el acero inicial; como consecuencia, el óxido ejerce presiones internas en el hormigón circundante, que lleva a la fisuración y, ocasionalmente, al desprendimiento del recubrimiento de hormigón. Durante los últimos años, numerosos estudios han contribuido a ampliar el conocimiento sobre el proceso de fisuración; sin embargo, aún existen muchas incertidumbres respecto al comportamiento mecánico de la capa de óxido, que es fundamental para predecir la fisuración. Por ello, en esta tesis se ha desarrollado y aplicado una metodología, para mejorar el conocimiento respecto al comportamiento del sistema acero-óxido-hormigón, combinando experimentos y simulaciones numéricas. Se han realizado ensayos de corrosión acelerada en condiciones de laboratorio, utilizando la técnica de corriente impresa. Con el objetivo de obtener información cercana a la capa de acero, como muestras se seleccionaron prismas de hormigón con un tubo de acero liso como armadura, que se diseñaron para conseguir la formación de una única fisura principal en el recubrimiento. Durante los ensayos, las muestras se equiparon con instrumentos especialmente diseñados para medir la variación de diámetro y volumen interior de los tubos, y se midió la apertura de la fisura principal utilizando un extensómetro comercial, adaptado a la geometría de las muestras. Las condiciones de contorno se diseñaron cuidadosamente para que los campos de corriente y deformación fuesen planos durante los ensayos, resultando en corrosión uniforme a lo largo del tubo, para poder reproducir los ensayos en simulaciones numéricas. Se ensayaron series con varias densidades de corriente y varias profundidades de corrosión. De manera complementaria, el comportamiento en fractura del hormigón se caracterizó en ensayos independientes, y se midió la pérdida gravimétrica de los tubos siguiendo procedimientos estándar. En todos los ensayos, la fisura principal creció muy despacio durante las primeras micras de profundidad de corrosión, pero después de una cierta profundidad crítica, la fisura se desarrolló completamente, con un aumento rápido de su apertura; la densidad de corriente influye en la profundidad de corrosión crítica. Las variaciones de diámetro interior y de volumen interior de los tubos mostraron tendencias diferentes entre sí, lo que indica que la deformación del tubo no fue uniforme. Después de la corrosión acelerada, las muestras se cortaron en rebanadas, que se utilizaron en ensayos post-corrosión. El patrón de fisuración se estudió a lo largo del tubo, en rebanadas que se impregnaron en vacío con resina y fluoresceína para mejorar la visibilidad de las fisuras bajo luz ultravioleta, y se estudió la presencia de óxido dentro de las grietas. En todas las muestras, se formó una fisura principal en el recubrimiento, infiltrada con óxido, y varias fisuras secundarias finas alrededor del tubo; el número de fisuras varió con la profundidad de corrosión de las muestras. Para muestras con la misma corrosión, el número de fisuras y su posición fue diferente entre muestras y entre secciones de una misma muestra, debido a la heterogeneidad del hormigón. Finalmente, se investigó la adherencia entre el acero y el hormigón, utilizando un dispositivo diseñado para empujar el tubo en el hormigón. Las curvas de tensión frente a desplazamiento del tubo presentaron un pico marcado, seguido de un descenso constante; la profundidad de corrosión y la apertura de fisura de las muestras influyeron notablemente en la tensión residual del ensayo. Para simular la fisuración del hormigón causada por la corrosión de las armaduras, se programó un modelo numérico. Éste combina elementos finitos con fisura embebida adaptable que reproducen la fractura del hormigón conforme al modelo de fisura cohesiva estándar, y elementos de interfaz llamados elementos junta expansiva, que se programaron específicamente para reproducir la expansión volumétrica del óxido y que incorporan su comportamiento mecánico. En el elemento junta expansiva se implementó un fenómeno de despegue, concretamente de deslizamiento y separación, que resultó fundamental para obtener localización de fisuras adecuada, y que se consiguió con una fuerte reducción de la rigidez tangencial y la rigidez en tracción del óxido. Con este modelo, se realizaron simulaciones de los ensayos, utilizando modelos bidimensionales de las muestras con elementos finitos. Como datos para el comportamiento en fractura del hormigón, se utilizaron las propiedades determinadas en experimentos. Para el óxido, inicialmente se supuso un comportamiento fluido, con deslizamiento y separación casi perfectos. Después, se realizó un ajuste de los parámetros del elemento junta expansiva para reproducir los resultados experimentales. Se observó que variaciones en la rigidez normal del óxido apenas afectaban a los resultados, y que los demás parámetros apenas afectaban a la apertura de fisura; sin embargo, la deformación del tubo resultó ser muy sensible a variaciones en los parámetros del óxido, debido a la flexibilidad de la pared de los tubos, lo que resultó fundamental para determinar indirectamente los valores de los parámetros constitutivos del óxido. Finalmente, se realizaron simulaciones definitivas de los ensayos. El modelo reprodujo la profundidad de corrosión crítica y el comportamiento final de las curvas experimentales; se comprobó que la variación de diámetro interior de los tubos está fuertemente influenciada por su posición relativa respecto a la fisura principal, en concordancia con los resultados experimentales. De la comparación de los resultados experimentales y numéricos, se pudo extraer información sobre las propiedades del óxido que de otra manera no habría podido obtenerse. Corrosion of steel is one of the main pathologies affecting reinforced concrete structures exposed to marine environments or to molten salt. When corrosion occurs, an oxide layer develops around the reinforcement surface, which occupies a greater volume than the initial steel; thus, it induces internal pressure on the surrounding concrete that leads to cracking and, eventually, to full-spalling of the concrete cover. During the last years much effort has been devoted to understand the process of cracking; however, there is still a lack of knowledge regarding the mechanical behavior of the oxide layer, which is essential in the prediction of cracking. Thus, a methodology has been developed and applied in this thesis to gain further understanding of the behavior of the steel-oxide-concrete system, combining experiments and numerical simulations. Accelerated corrosion tests were carried out in laboratory conditions, using the impressed current technique. To get experimental information close to the oxide layer, concrete prisms with a smooth steel tube as reinforcement were selected as specimens, which were designed to get a single main crack across the cover. During the tests, the specimens were equipped with instruments that were specially designed to measure the variation of inner diameter and volume of the tubes, and the width of the main crack was recorded using a commercial extensometer that was adapted to the geometry of the specimens. The boundary conditions were carefully designed so that plane current and strain fields were expected during the tests, resulting in nearly uniform corrosion along the length of the tube, so that the tests could be reproduced in numerical simulations. Series of tests were carried out with various current densities and corrosion depths. Complementarily, the fracture behavior of concrete was characterized in independent tests, and the gravimetric loss of the steel tubes was determined by standard means. In all the tests, the main crack grew very slowly during the first microns of corrosion depth, but after a critical corrosion depth it fully developed and opened faster; the current density influenced the critical corrosion depth. The variation of inner diameter and inner volume of the tubes had different trends, which indicates that the deformation of the tube was not uniform. After accelerated corrosion, the specimens were cut into slices, which were used in post-corrosion tests. The pattern of cracking along the reinforcement was investigated in slices that were impregnated under vacuum with resin containing fluorescein to enhance the visibility of cracks under ultraviolet lightening and a study was carried out to assess the presence of oxide into the cracks. In all the specimens, a main crack developed through the concrete cover, which was infiltrated with oxide, and several thin secondary cracks around the reinforcement; the number of cracks diminished with the corrosion depth of the specimen. For specimens with the same corrosion, the number of cracks and their position varied from one specimen to another and between cross-sections of a given specimen, due to the heterogeneity of concrete. Finally, the bond between the steel and the concrete was investigated, using a device designed to push the tubes of steel in the concrete. The curves of stress versus displacement of the tube presented a marked peak, followed by a steady descent, with notably influence of the corrosion depth and the crack width on the residual stress. To simulate cracking of concrete due to corrosion of the reinforcement, a numerical model was implemented. It combines finite elements with an embedded adaptable crack that reproduces cracking of concrete according to the basic cohesive model, and interface elements so-called expansive joint elements, which were specially designed to reproduce the volumetric expansion of oxide and incorporate its mechanical behavior. In the expansive joint element, a debonding effect was implemented consisting of sliding and separation, which was proved to be essential to achieve proper localization of cracks, and was achieved by strongly reducing the shear and the tensile stiffnesses of the oxide. With that model, simulations of the accelerated corrosion tests were carried out on 2- dimensional finite element models of the specimens. For the fracture behavior of concrete, the properties experimentally determined were used as input. For the oxide, initially a fluidlike behavior was assumed with nearly perfect sliding and separation; then the parameters of the expansive joint element were modified to fit the experimental results. Changes in the bulk modulus of the oxide barely affected the results and changes in the remaining parameters had a moderate effect on the predicted crack width; however, the deformation of the tube was very sensitive to variations in the parameters of oxide, due to the flexibility of the tube wall, which was crucial for indirect determination of the constitutive parameters of oxide. Finally, definitive simulations of the tests were carried out. The model reproduced the critical corrosion depth and the final behavior of the experimental curves; it was assessed that the variation of inner diameter of the tubes is highly influenced by its relative position with respect to the main crack, in accordance with the experimental observations. From the comparison of the experimental and numerical results, some properties of the mechanical behavior of the oxide were disclosed that otherwise could not have been measured.
Resumo:
La durabilidad de las estructuras de hormigón armado no es ilimitada, en especial en determinados ambientes. El ingreso de agentes agresivos en el hormigón, fundamentalmente dióxido de carbono e iones cloruros, rebasando el espesor del recubrimiento y alcanzando las armaduras, reducen el alto pH del hormigón hasta alcanzar un umbral crítico, por debajo del cual, el acero queda despasivado. Posteriormente, si existe el suficiente aporte de humedad y oxígeno, el acero se corroe, lo que supone drásticas reducciones de la vida de servicio de estas estructuras y su inevitable reparación. La utilización de armaduras de acero inoxidable es una alternativa que está recibiendo cada vez más consideración. Su resistencia a la corrosión en los ambientes más agresivos, incluso con ataque de cloruros, lo convierte en el material idóneo para prolongar de forma muy considerable la vida útil de la estructura. En este trabajo se ha evaluado el comportamiento mecánico y estructural, y de resistencia a la corrosión, de un nuevo acero inoxidable dúplex de bajo contenido en níquel, el EN 1.4482 (AISI 2001), y se ha comparado con el inoxidable austenítico más utilizado, el EN 1.4301 (AISI 304), con el dúplex EN 1.4362 (AISI 2304) y con el tradicional acero al carbono B-500-SD. El estudio mecánico y estructural se ha realizado en tres niveles diferentes: a nivel de barra, estudiando las propiedades mecánicas y de ductilidad de los cuatro aceros citados; a nivel de sección, estudiando su comportamiento a flexión con diferentes cuantías de armado por medio de los diagramas momento-curvatura; y a nivel de pieza, ensayando una serie de vigas armadas con diferentes aceros y cuantías, y comprobando su comportamiento a desplazamiento y resistencia por medio de los diagramas carga-desplazamiento. El estudio de resistencia a la corrosión se ha realizado embebiendo barras corrugadas, de los tres aceros inoxidables mencionados, en probetas de mortero contaminadas con diferentes cantidades de cloruros, y realizando mediciones electroquímicas durante un periodo de al menos un año. Se han preparado probetas de mortero para dos comparativas diferentes. La primera, manteniendo las probetas en un desecador con el 95 % de humedad relativa durante todo el periodo de mediciones. La segunda, sumergiendo parcialmente las probetas en una solución tampón para carbonatar el mortero. Los resultados de los ensayos mecánicos han demostrado dos aspectos diferentes. Uno, que las armaduras de acero inoxidable tienen un comportamiento muy similar a las de acero al carbono en lo referente a las resistencias alcanzadas, en el límite elástico y en rotura, pero distinto en cuanto al módulo de deformación longitudinal, cuyo valor es claramente inferior al del acero al carbono, por lo que su utilización en las estructuras de hormigón necesita tener en cuenta ese dato en los análisis lineales de cálculo. El segundo aspecto es que las armaduras de acero inoxidable laminadas en caliente presentan una ductilidad muy superior a las de acero al carbono, por lo que ofrecen una mayor seguridad frente a su rotura o al colapso de la estructura, lo que se debe tener en cuenta en el análisis de cálculo plástico. En cambio, las armaduras de acero inoxidable laminadas en frío sólo cumplen con los límites mínimos de ductilidad establecidos en la instrucción EHE-08 para los aceros soldables, y no para los aceros con características especiales de ductilidad. El estudio a nivel de sección refleja la paradoja de obtener secciones menos dúctiles con las armaduras de acero inoxidable laminadas en caliente que con las armaduras de acero al carbono. Para subsanarlo, se definen los conceptos de curvatura última de rotura y ductilidad de la sección en rotura, que tienen en cuenta las altas deformaciones alcanzadas por las armaduras de acero inoxidable. Los resultados a nivel de pieza permiten identificar el comportamiento estructural del hormigón armado con barras corrugadas de acero inoxidable y compararlo con el de las estructuras de hormigón armado convencionales, verificando los resultados experimentales con los teóricos obtenidos con la formulación recogida en la instrucción EHE- 08. Los ensayos de resistencia a la corrosión por cloruros demuestran, durante el primer año y medio de vida de las probetas, un comportamiento muy similar entre el nuevo acero inoxidable dúplex bajo en níquel y el austenítico y el dúplex utilizados para la comparación, incluso para las probetas carbonatadas. Por último, se añade una comparativa económica, realizada sobre dos edificaciones tipo, para cuantificar el sobrecoste que supone la utilización de armaduras de acero inoxidable respecto a las de acero al carbono. El alto coste inicial de las armaduras de acero inoxidable se ve compensado en el coste final de la estructura de muy diferentes formas, principalmente dependiendo del grado de acero elegido y de si se emplean en el total de la estructura o solamente en los elementos más expuestos. The durability of the concrete structures is limited, especially in certain environments. The attack of aggressive agents in the concrete, mainly carbon dioxide and chloride ions, penetrating the thickness of concrete cover and reaching the reinforcements, reduce the high pH of concrete to the point of reaching a critical threshold, under which, the steel despasivates. Therefore, if there is enough humidity and oxygen, the steel corroes, causing drastic reductions in the service life of these structures and its inevitable repair. Despite the high initial cost compared to carbon steel, the usage of stainless steel reinforcements is an alternative with a major consideration nowadays. Its resistance to corrosion in the most aggressive atmospheres, including chlorides attack, makes the stainless steel a suitable material to extend considerably its lifetime. In this study, it’s been evaluated the mechanical and structural behaviour, and the corrosion resistance, of a new low-nickel duplex stainless steel EN 1.4482 (AISI 2001), and it has been compared with the most widely used austenitic type EN 1.4301 (AISI 304), with duplex steel EN 1.4362 (AISI 2304) and with the traditional carbon steel B-500-SD. The mechanical and structural study has been carried out in three different levels: bar level, studying mechanical properties and ductility of the four steels; section level, studying its behaviour when blending with different amounts of reinforcement through the moment-curvature diagrams; and structural element level, testing a series of reinforced beams with different steels and amounts, and checking its sag and resistance through the load-deflection diagrams. The corrosion resistance study was performed by embedding ribbed bars, using the three stainless steel listed, on mortar specimens contaminated with different amounts of chlorides, and taking electrochemical measurements over a period of at least one year. Mortar specimens have been prepared for two different comparisons. The first, keeping the specimens at 95% of relative humidity during the measurement period. The second, immersing the specimens partially in a carbonate buffer solution. The results of those tests have proved two different aspects. Firstly, that stainless steel reinforcements show a very similar behaviour to carbon steel, according to the reached levels of mechanical resistance, yield stress and steel strength, but a different behaviour in Young’s modulus, which value is clearly lower than the carbon steel. Therefore, when using in concrete structures it is need to consider on that point the existing calculus of linear analysis. The second aspect is that stainless steel reinforcement manufactured by hot-rolling process show a very higher ductility than carbon steel, offering a better security on cracks or structure collapse, which it has to be taken into account on plastic calculus analysis. However, the stainless steel reinfor9 cement cold-rolled bars only meet the minimum thresholds of ductility established by EHE-08 for welded steel, and not for steels with special ductility. The results at the section level reflect the paradox of getting less ductile sections with hot rolled stainless steel reinforcement than with carbon steel reinforcements. To overcome that, the concepts of last break curvature and break ductility section have been defined, which take into account the high deformation value achieved by stainless steel reinforcements. The results at the structural element level allow to identify the structural behaviour of reinforced concrete with stainless steel reinforcements and compared with that of conventional steel reinforcement, contrasting the experimental with the theoretical results obtained from the formulation contained in the instruction EHE-08. Tests on resistance of chloride corrosion show during the first year and a half of specimens life, a similar behaviour between the new low nickel duplex stainless steel and austenitic and duplex used for comparison, even for carbonated specimens. Finally, it has been included an economic comparison on two differents building types, to quantify the additional cost involved on the use of stainless steel reinforcement compared to that of carbon steel. The high initial cost of stainless steel reinforcements is offset in the final cost of the structure in many different ways, mainly depending on the chosen steel grade and whether the reinforcement is used in the total structure or only in risky structural elements.
Resumo:
En este trabajo se ha evaluado la resistencia a la corrosión por cloruros de un nuevo acero inoxidable dúplex de bajo contenido en níquel, el AISI 2001. Se han utilizado técnicas electroquímicas, monitorizando el potencial de corrosión y la resistencia de polarización (LPR) mediante técnicas de corriente continua y medidas de corriente alterna mediante espectroscopía de impedancia electroquímica (EIS). Los ensayos muestran un excelente comportamiento en presencia de elevados contenidos de cloruro del nuevo acero dúplex. Se ha caracterizado la composición de la capa pasiva del acero inoxidable mediante XPS.
Resumo:
El objetivo del presente trabajo es estudiar el comportamiento frente a la corrosión de barras de acero de armar embebidas en probetas de mortero, en las que se ha sustituido parcialmente el árido y el cemento por escorias blancas de horno cuchara (LFS) y se ha añadido en el momento del amasado distintos porcentajes de ión cloruro, en peso de cemento. Se han fabricado probetas prismáticas de 6x8x2 cm3, en las que se han embebido 3 barras de acero de diámetro 6 mm, con el fin de comparar el potencial de corrosión y la velocidad de corrosión, en las probetas patrón y en las probetas con escorias. Los resultados alcanzados permiten afirmar que el comportamiento frente a la corrosión inducida por iones cloruro en barras de acero embebidas en probetas patrón y en probetas fabricadas parcialmente con escorias blancas de horno cuchara son semejantes, tanto en las velocidades de corrosión alcanzadas como en el umbral de cloruros que produce la despasivación del acero.
Resumo:
La utilización de armaduras de acero inoxidable en estructuras de hormigón es una alternativa que está recibiendo cada vez más consideración, con objeto de aumentar la durabilidad debido a su buen comportamiento frente a la corrosión en ambientes agresivos, especialmente en atmósferas marinas con elevado contenido de cloruros. El elevado coste del níquel provocado por la fluctuación de su valor de mercado ha motivado la fabricación de nuevos aceros inoxidables con bajo contenido en dicha aleación. En este trabajo se ha evaluado la resistencia a la corrosión por cloruros de un nuevo acero inoxidable dúplex de bajo contenido en níquel, el AISI 2001. Se han utilizado técnicas electroquímicas, monitorizando el potencial de corrosión y la resistencia de polarización (LPR) mediante técnicas de corriente continua y medidas de corriente alterna mediante espectroscopía de impedancia electroquímica (EIS). Los ensayos muestran un excelente comportamiento en presencia de elevados contenidos de cloruro del nuevo acero dúplex. Se ha caracterizado la composición de la capa pasiva del acero inoxidable mediante XPS.
Resumo:
Tesis (Maestro en Ciencias de la Ingeniería Mecánica con Especialidad en Materiales) UANL, 2000.
Resumo:
Los efectos de la corrosión sobre las armaduras se manifiestan por la pérdida de sección y la variación de las propiedades mecánicas relacionadas con la ductilidad. En este trabajo se han ensayado a tracción 96 barras de acero B500SD que previamente se han sometido a niveles variables de corrosión. Los resultados muestran que los alargamientos de las barras disminuyen y el cociente entre la tensión máxima y el límite elástico aumenta conforme el nivel de corrosión avanza. A partir del estudio del efecto de entalla y de la distinta constitución metalográfica del acero a nivel de sección debido a su procedimiento de fabricación se pueden explicar los fenómenos anteriores.
Resumo:
La utilización de armaduras de acero inoxidable, de los tipos austeníticos y dúplex, con el objetivo de prolongar la vida útil de las estructuras de hormigón, es una alternativa que está recibiendo cada vez más consideración. Los aceros inoxidables son aleaciones fundamentalmente de cromo y níquel, con muy alta resistencia a la corrosión, especialmente por cloruros. El elevado coste del níquel y sus grandes fluctuaciones en el mercado, han favorecido la aparición de nuevos aceros inoxidables con bajo contenido en dicha aleación y, por lo tanto, más económicos, que sin embargo presentan una resistencia a la corrosión similar a los tradicionales. En este trabajo se ha evaluado la resistencia a la corrosión por cloruros de dos nuevos aceros inoxidables de bajo contenido en níquel. Uno de los aceros es austenítico, de producción en forma de chapa, y el otro dúplex, que se comercializa como barra corrugada. La resistencia a la corrosión se ha evaluado, respectivamente, mediante ensayos electroquímicos de dichos aceros embebidos en solución simulada de poros de hormigón y en probetas de mortero contaminados con diferentes cuantías de cloruros. Los resultados de los ensayos se han comparado con los del acero austenítico tradicional AISI 304 y del acero al carbono B500SD.
Resumo:
El objetivo principal de este trabajo es profundizar en el conocimiento del fenómeno de la corrosión subpelicular inducida por contaminantes hidrosolubles en la intercara metal/pintura. La contaminación salina del substrato es una situación común en la práctica: la superficie metálica suele estar expuesta a atmósferas contaminadas antes de ser recubierta, limpieza previa del metal con abrasivos contaminados, etc. La eliminación total de estos contaminantes resulta muy difícil de conseguir incluso con las técnicas más sofisticadas de limpieza. Esta investigación se centra en la determinación del efecto de la naturaleza del contaminante y la naturaleza y espesor del recubrimiento en el proceso de corrosión subpelicular del acero. En la investigación se utilizaron dos barnices de naturaleza diferente: poliuretano y vinílico; y se aplicaron a tres espesores diferentes. Los contaminantes empleados en este trabajo fueron: NaCl, NH4C1, CaCl2, Na2S04, (NH4)2S04, NaN03, NH4N03, Ca(N03)2. Los ensayos se realizaron en una cámara de condensación de humedad permanente. Los tiempos de exposición fueron 100, 300 y 600 horas. La velocidad de corrosión se evaluó gravimétricamente, mediante la técnica de pérdida de peso. Se realizaron estudios de permeabilidad al oxígeno y al agua de películas libres de substrato, evaluación de la velocidad de corrosión de probetas sin pintar inmersas en soluciones salinas de los contaminantes seleccionados, conductividad de dichas soluciones salinas, solubilidad del oxígeno en las soluciones salinas, adherencia en seco y en húmedo a diferentes tiempos de exposición. Se aporta evidencia respecto al control ejercido en el proceso corrosivo por el oxígeno que permea a través de la película, mientras que la permeación de agua controla la pérdida de adherencia del recubrimiento. Ambas permeabilidades dependen de la naturaleza del recubrimiento y de su espesor. Se ha investigado la influencia de la naturaleza del contaminante en la intercara metal/pintura. La naturaleza del catión parece quedar enmascarada por el efecto definitivo del anión. La concentración salina ejerce asimismo un efecto importante en la corrosión subpelicular. ABSTRACT The main aim of this work is to study in depth the knowledge of underfilm corrosión induced by hydrosoluble contaminants at the metal/paint Ínterface. The saline contamination of the substrate is a common situation in practice: metallic surfaces use to be exposed to polluted atmospheres, previous cleaning of the metal with contaminated abrasives, etc. Total elimination of these contaminants is hard to obtain even with modern cleaning techniques. This research is focused in determining the effect of contaminant nature, coating nature and its thickness on the steel underfilm corrosión process. In this work we used two varnishes with different nature: polyurethane and vinyl; they were applied in three different thicknesses. The saline contaminants employed were: NaCl, NH4C1, CaCl2, Na2S04, (NH4)2S04, NaN03, NH4N03/ Ca(N03)2. The tests were carried out in a condensation humidity chamber. The period of exposure were 100, 300 and 600 hours. Corrosión rate was assessed by weight loss. Simultaneously, studies on oxygen and water permeability of free films, assessing on corrosión rate of uncoated samples immersed in saline solutions of the selected contaminants, conductivity of these solutions, oxygen solubility in saline solutions, wet and dry adhesión of the polyurethane varnish at different periods of exposure, were carried out. There is clear evidence about control on corrosión process of oxygen that passes through the coating, while the passing of water controls the loss of adhesión of the coating. Both, water and oxygen permeation, depend on the nature and thickness of the coating. It has been researched the inf luence of the nature of contaminant at the metal/paint interface. The nature of the catión seems to be "masked" by the definitive effect of the nature of anión. The saline concentration also exerts an important effect on underfilm corrosión.
Resumo:
202 p. El contenido de los capítulos 3,4,5 y 6 está sujeto a confidencialidad
Resumo:
En este trabajo se determina la tolerancia al daño de un acero inoxidable austeno-ferrítico trefilado hasta obtener resistencia propias del acero de pretensado. Para ello se han realizado ensayos de fractura sobre alambres con secciones transversales debilitadas por fisuras de fatiga propagadas desde la superficie exterior. La medida de la tolerancia al daño adoptada es la curva empírica carga de rotura-profundidad de fisura. Para valorar cuantitativamente los resultados, se utilizan las curvas de dos aceros de pretensar eutectoides, respectivamente fabricados por trefilado y por tratamiento térmico de templado y revenido, así como un modelo elemental de colapso plástico por tracción para alambres fisurados. La microestructura austeno-ferrítico de los alambres inoxidables adquiere una marcada orientación en la dirección de trefilado, que induce una fuerte anisotropía de fractura en los alambres y condiciona su mecanismo macroscópico de colapso a tracción cuando están Asurados. Para observar este mecanismo se ha utilizado la técnica VIC-2D de adquisición y análisis computerizado de imágenes digitales en ensayos mecánicos, aplicándola a ensayos de fractura a tracción realizados con probetas planas de alambre inoxidable trefilado Asuradas transversalmente. Damage tolerance of a high strength cold-drawn ferritic-austenitic stainless steel is assessed by means of tensile fracture tests of cracked wires. A fatigue crack was transversally propagated from the wire surface. The damage tolerance curve of the wires results from the empirical failure load when given as a function of crack depth. As a consequence of cold drawing, the wire microstructure is orientated along its longitudinal axis and anisotropic fracture behavior is found at macrostructural level at the tensile failure of the cracked specimens. An in situ optical technique known as video image correlation VIC-2D was used to get an insight into this failure mechanism by tensile testing transversally fatigue cracked plañe specimens extracted from the cold-drawn wires. Additionally, the experimentally obtained damage tolerance curve of the cold-drawn ferritic-austenitic stainless steel wires is compared with that of the two types of high strength eutectoid wires currently used as prestressing steel for concrete. An elementary plástic collapse model for tensile failure of surface cracked wires is used to assess the damage tolerance curves.
Resumo:
El trabajo desarrollado y aquí presentado trata de estudiar la carga crítica exterior que produce la abolladura de tuberías de acero confinadas en hormigón, como consecuencia de una presión externa provocada por la entrada de agua entre tubería y anillo exterior de hormigón, por una presión no controlada en la inyección de junta entre tubería y hormigón, o por otra causa. Para ello se abordará un estudio paramétrico en el cual intervendrán el espesor de la tubería, el diámetro de la misma, el límite elástico del acero, el espesor del confinamiento de hormigón, la posibilidad de que no haya un contacto directo entre acero y hormigón por una irregularidad o defecto en la superficie del tubo, así como cualquier otro parámetro que durante el desarrollo del trabajo se determine que influye en el fenómeno estudiado. Con el estudio desarrollado se comprobarán y contrastarán los resultados que se derivan de las expresiones analíticas y experimentales con las que se proyectan las conducciones y que se encuentran en la bibliografía especializada. En el desarrollo del trabajo se comprobará que el fenómeno físico que se pretende modelar es extraordinariamente ‘no lineal’ y que son muchas las fuentes de ‘no linealidad’ que influyen. Se discernirá cuáles de éstas pueden omitirse para facilitar el trabajo. Además, y atendiendo a la carga lectiva del TFM se pretende limitar el trabajo a un estudio 2D del fenómeno, planteando una posible línea de estudio la extensión a 3D y la influencia de rigidizadores longitudinales en este caso.
Resumo:
En los últimos años ha aumentado el interés en el desarrollo de proyectos en el ámbito de las centrales hidroeléctricas y en concreto en las centrales reversibles. Estas centrales están diseñadas para grandes caudales y saltos, lo cual conlleva túneles de gran diámetro y alta presión y a menudo son esquemas subterráneos. Por ello, los estudios relativos a revestimientos de túneles en presión y los referentes a los blindajes de acero han cobrado una mayor relevancia. En las décadas de los 60 y 70 se realizó una importante labor de investigación coincidiendo con el desarrollo hidroeléctrico en Europa y Norteamérica, que sin embargo ha quedado sin continuidad hasta esta década, en la que se ha experimentado un impulso debido al desarrollo de nuevos proyectos hidroeléctricos de gran magnitud. La adecuación de los métodos de cálculo de blindajes supone una herramienta imprescindible en el correcto desarrollo técnico de los nuevos proyectos hidroeléctricos, así como para la evaluación de la seguridad de los saltos hidroeléctricos existentes en operación. En la presente Tesis se realiza un análisis del comportamiento estructural de las galerías en presión de saltos hidroeléctricos, así como una discusión y revisión de los métodos de cálculo existentes. En concreto se analizan los siguientes aspectos: •Descripción y comparación de las formulaciones existentes para el cálculo de blindajes tanto a presión exterior como interior. •Aplicación del Método de Elementos Finitos para la modelización y cálculo resistente y frente a inestabilidad de blindajes sometidos a presión exterior. •Análisis de un caso real, en el que se ha producido un fallo estructural en un blindaje sometido a presión exterior. Discusión sobre el comportamiento de blindajes con rigidizadores. Estudio paramétrico de la capacidad resistente y de la estabilidad de los blindajes con rigidizadores. •Estudio del comportamiento diferenciado entre un rigidizador y un conector. •Detalles constructivos y de durabilidad de las galerías en presión. •Desarrollo de una metodología para el cálculo de blindajes y tuberías forzadas a fatiga derivada de las variaciones de presión de la conducción. •Análisis de un caso real de una tubería forzada sometida a procesos de variación de carga, evaluando su seguridad frente a la fatiga. El cálculo de blindajes en galerías forzadas presenta una serie de aspectos complejos, y que no permiten la definición del problema con exactitud, tales como las características del macizo rocoso y su permeabilidad, la determinación del nivel freático, la holgura existente entre el blindaje y el revestimiento del trasdós y sus posibles defectos geométricos. Por estas incertidumbres, el cálculo de blindajes supone una materia compleja y que debe ser abordada desde la cautela y el análisis de otros trabajos y/o análisis realizados con anterioridad. En cualquier caso, debe realizarse un análisis de sensibilidad de los diversos parámetros que intervienen en el cálculo. En esta tesis se han descrito las principales formulaciones de cálculo de blindajes de galerías forzadas sometidas a presión interior y exterior; se ha constatado que existe una gran diversidad y que de su aplicación no se llega a resultados concluyentes. Las formulaciones clásicas utilizadas en el cálculo de blindajes lisos y con rigidizadores sometidos a presión exterior (Amstutz y Jacobsen) no resultan del todo adecuadas ni son de aplicación general. Además, pueden arrojar resultados no conservadores o conducir a un sobredimensionamiento del blindaje en otros casos. En las formulaciones tradicionales de diseño se han tenido en cuenta como imperfecciones la holgura del blindaje y la ovalidad del mismo. En la presente tesis, se han analizado imperfecciones de tipo ondulatorio derivadas de los procesos de soldadura y la existencia de espesores reducidos en zonas de corrosión. En el caso práctico analizado sometido a presión exterior, se ha comprobado el funcionamiento real del blindaje mediante los modelos realizados con elementos finitos. Se desprende que los rigidizadores no han funcionado como tales, puesto que para blindajes lisos se obtienen presiones más bajas de pandeo y para el caso de funcionamiento correcto de los rigidizadores se habría obtenido un coeficiente de seguridad suficiente. Por este motivo, se ha analizado el posible funcionamiento de los rigidizadores, que en determinados casos pueden actuar como conectores. En estos casos deben dimensionarse de forma adecuada las soldaduras para soportar las tensiones entre chapa y conector. Por otra parte, tradicionalmente no se han tenido en cuenta los efectos de fatiga que pueden ocasionar los golpes de ariete y las pulsaciones de presión debidas a la regulación secundaria de la red. En esta tesis se ha establecido un procedimiento de comprobación de tuberías forzadas y blindajes sometidos a procesos de fatiga. Adicionalmente, se ha estudiado el caso real de las tuberías forzadas de una central reversible real (Bolarque II) en funcionamiento de regulación secundaria. Se ha concluido, como en otros casos analizados en la bibliografía, que las pulsaciones derivadas de la regulación secundaria no son significativas como para tener en cuenta la fatiga del acero. Por otra parte, las maniobras de arranque y parada (golpe de ariete) suponen una variación importante de la presión en la conducción. Sin embargo, el moderado número de ciclos permite asegurar la integridad de la tubería frente a fenómenos de fatiga. Nowadays, there is a significant concern in the development of projects in the field of hydroelectric power plants, particularly in the pump-storage projects. These plants are designed for high flow rates and heads, which entails large-diameter tunnels and high pressure ratios), and often as underground schemes. Therefore, this concern has reactivated studies about penstocks and in particular those related to steel liners. During the 1960s and 1970s due to hydropower-engineering development in Europe and North America, a major research effort was done. However, the increasing development of new large-scale hydropower projects has involved a renewed research effort during this decade. The adequacy of steel liner calculation methods is a very important issue in the proper technical development of new hydroelectric projects, and for the safety assessment of existing hydroelectric power plants in operation. In this work, an analysis of the structural behavior of pressure galleries in hydroelectric schemes was carried out. Also, a discussion and a review of existing calculation methods are included. In particular, the following issues have been considered: •Description and comparison of existing formulations for calculating the liner response to both external and internal pressure. •Analysis of an actual case study of a steel liner which failed due to external pressure. •Application of the Finite Element Method to liner modeling and analysis subjected to external pressure. •A parametric study of the shielding with stiffeners and discussion about the behavior of liner with stiffeners. •Constructive aspects and durability of pressure galleries. •Development of a methodology for estimating fatigue effects on penstocks and liners sue to pressure changes. •Analysis of an actual case study of a penstock under varying load and assessment of its safety against fatigue. The project of a hydropower penstock is a complex issue, due to the uncertainties in the definition of the problem data, such as the characteristics of the rock mass and its permeability, the determination of the water table, the existing gap between the steel liner and the concrete of the backfill, the geometric imperfections... Hence, the design and analysis of a steel liner must be addressed cautiously and take into account a review of previous studies performed. Ever, a sensitivity analysis of the various parameters involved in the calculation should be performed. In this work, some of the most relevant formulations for liner design subjected to inside and outside pressure have been studied. As a whole, there is a wide variety and its application does not lead to conclusive results. The classical formulations used in the steel liner calculation either with or without stiffeners under external pressure (Amstutz and Jacobsen) are not entirely adequate Also, those can yield both conservative and non-conservative results in large ranges of application. Traditionally design approaches only considered initial gap and ovality as the most relevant geometric imperfections. Thus, little attention was paid to those caused either by welding or by thickness loss in corroded areas. In the case study analyzed in this thesis, the actual working of the liner under external pressure has been simulated by the Finite Element Method. Results show that the stiffeners have not performed as such, since for unstiffened liner lower buckling pressures are obtained and for proper performance of the stiffeners would give a sufficient safety factor. Hence, it must be pointed out that stiffeners may perform either as such or as connectors. For the latter, welding must be designed to properly withstand stresses between the shell and the stiffener. Likewise, the potential fatigue effects due to both water hammer and pressure pulsations due to secondary regulation of the network have not been considered in many studies. It has been included in this work a procedure for checking penstocks and liners under fatigue processes. Additionally, the penstock fatigue response of an actual pump storage project (Bolarque II, Spain) subjected to secondary control operation has been assessed. As in other cases discussed in the literature, pulsations derived from the secondary control are not significant to account for fatigue of steel. Moreover, the start and stop manoeuvres (water hammer) cause a significant change in penstock pressure. However, the moderate number of cycles ensures the integrity of the penstock against fatigue phenomena.