454 resultados para Cornea.


Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper is aimed at establishing a particular chronological priority issue in the convoluted history of artificial cornea. According to existing records, the first keratoprosthesis made from polyurethane was developed by Caldwell and Jacob-Labarre in the late 1980s. This paper demonstrates that in fact the first polyurethane keratoprosthesis was proposed and designed in 1985 by Lawrence Hirst, an Australian ophthalmologist then working in St Louis, USA. The first prototype was manufactured in January 1986 by Thermedics Inc according to Dr Hirst's instructions from Tecoflex, a transparent polyurethane developed by the same company. This keratoprosthesis, which also had a porous skirt, was inserted intralamellarly in a monkey cornea and followed up clinically for about 3 months. There were no significant postoperative complications, and the histology of the explant indicated proper biointegration of the prosthetic skirt within the host stromal tissue. Because of a delay in the manufacture of further prototypes and to Dr Hirst's decision to return to Australia, the project was eventually abandoned. As no report was published on this development, the present paper is entirely based on original documents held in Dr Hirst's archives.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We assess the accuracy of the Visante anterior segment optical coherence tomographer (AS-OCT) and present improved formulas for measurement of surface curvature and axial separation. Measurements are made in physical model eyes. Accuracy is compared for measurements of corneal thickness (d1) and anterior chamber depth (d2) using-built-in AS-OCT software versus the improved scheme. The improved scheme enables measurements of lens thickness (d 3) and surface curvature, in the form of conic sections specified by vertex radii and conic constants. These parameters are converted to surface coordinates for error analysis. The built-in AS-OCT software typically overestimates (mean±standard deviation(SD)]d1 by +62±4 μm and d2 by +4±88μm. The improved scheme reduces d1 (-0.4±4 μm) and d2 (0±49 μm) errors while also reducing d3 errors from +218±90 (uncorrected) to +14±123 μm (corrected). Surface x coordinate errors gradually increase toward the periphery. Considering the central 6-mm zone of each surface, the x coordinate errors for anterior and posterior corneal surfaces reached +3±10 and 0±23 μm, respectively, with the improved scheme. Those of the anterior and posterior lens surfaces reached +2±22 and +11±71 μm, respectively. Our improved scheme reduced AS-OCT errors and could, therefore, enhance pre- and postoperative assessments of keratorefractive or cataract surgery, including measurement of accommodating intraocular lenses. © 2007 Society of Photo-Optical Instrumentation Engineers.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Bilateral corneal blindness represents a quarter of the total blind, world-wide. The artificial cornea in assorted forms, was developed to replace opaque non-functional corneas and to return sight in otherwise hopeless cases that were not amenable to corneal grafts; believed to be 2% of corneal blind. Despite technological advances in materials design and tissue engineering no artificial cornea has provided absolute, long-term success. Formidable problems exist, due to a combination of unpredictable wound healing and unmanageable pathology. To have a solid guarantee of reliable success an artificial cornea must possess three attributes: an optical window to replace the opaque cornea; a strong, long term union to surrounding ocular tissue; and the ability to induce desired host responses. A unique artificial cornea possesses all three functional attributes- the Osteo-odonto-keratoprosthesis (OOKP). The OOKP has a high success rate and can survive for up to twenty years, but it is complicated both in structure and in surgical procedure; it is expensive and not universally available. The aim of this project was to develop a synthetic substitute for the OOKP, based upon key features of the tooth and bone structure. In doing so, surgical complexity and biological complications would be reduced. Analysis of the biological effectiveness of the OOKP showed that the structure of bone was the most crucial component for implant retention. An experimental semi-rigid hydroxyapatite framework was fabricated with a complex bone-like architecture, which could be fused to the optical window. The first method for making such a framework, was pressing and sintering of hydroxyapatite powders; however, it was not possible to fabricate a void architecture with the correct sizes and uniformity of pores. Ceramers were synthesised using alternative pore forming methods, providing for improved mechanical properties and stronger attachment to the plastic optical window. Naturally occurring skeletal structures closely match the structural features of all forms of natural bone. Synthetic casts were fabricated using the replamineform process, of desirable natural artifacts, such as coral and sponges. The final method of construction by-passed ceramic fabrication in favour of pre-formed coral derivatives and focused on methods for polymer infiltration, adhesion and fabrication. Prototypes were constructed and evaluated; a fully penetrative synthetic OOKP analogue was fabricated according to the dimensions of the OOKP. Fabrication of the cornea shaped OOKP synthetic analogue was also attempted.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The study investigated the central and peripheral corneal characteristics of groups of subjects from 20 to 90 years of age to assist the understanding of ageing changes in the cornea, and to see whether relationships between ocular parameters were revealed. After age 45 the corneal horizontal radius of curvature gradually decreased with age. This trend was shown by the Aston University subjects (group B). The effect was very significant for the hospital patients undergoing biometry before cataract extraction operation (group D). Vertical radius of curvature showed a slight decrease with age after age 45, but similar to corneal eccentricity, this showed no significant age effect. Corneal astigmatism progressed from with the rule towards against the rule, particularly after age 60. The shift seemed mainly due to the decreasing horizontal corneal curvature. In biometry no significant age relation was found for axial length, but a significant relation was found between curvature and axial length in the larger group D. Lens thickness showed a very significant relation to age and to axial length, but no significant relation to corneal curvature. Anterior chamber depth showed a very significant relation to age, lens thickness and axial length, but no significant relation to corneal curvature. A significant age effect was found for corneal thickness decreasing with age for the central, nasal and temporal regions of the right eye. Analysis of the biometry results indicated the influence of two major factors. Firstly, the natural growth of the eye in youth, leading to greater values of axial length, radius of corneal curvature, lens thickness and anterior chamber depth. Secondly, the typical ageing changes where the increasing lens thickness caused a reduction in anterior chamber depth. The decrease in corneal thickness with age shown in some corneal regions may be a sign of ageing changes in the tissue proteins and hydration balance.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: We have reported that the changes in the pupillary shape in response to electrical stimulation of the branches of the ciliary nerves in cats. (Miyagawa et al. PLoS One, 2014). This study investigates the changes in the pupillary shapes in response to electrical stimulations of the sclera of peripheral cornea in cats and porcines. Methods: Two enucleated eyes of two cats and three enucleated porcine eyes were studied. Trains of biphasic pulses (current, 3 mA; duration, 2 ms/phase; frequency, 40 Hz) were applied using a tungsten electrode (0.3mm diameter). The stimulation was performed at every 45 degree over the entire circular region on the sclera near the cornea. The pupillary images were recorded before and 4 s (cat) and 10 s (pig) after the stimulation and the change in the pupil diameter (Δr) was quantified. The pupillary images were obtained with a custom-built compact wavefront aberrometer (Uday et al. J Cataract Refract Surg, 2013). Results: In a cat eye, the pupil was dilated by the electrical stimulation at six out of eight orientations (before stimulation pupil diameter r=10.10±0.49 mm, Δr=0.33±0.12 mm). The pupil dilated only toward the electrode (relative eccentricity of the pupil center to the pupil diameter change amount rdec=1.15±0.28). In the porcine eyes, the pupils were constricted by the electrical stimulations at the temporal and nasal orientations (r=10.04±0.57 mm, Δr=1.52±0.70 mm). The pupils contracted symmetrically (rdec=0.30±0.12). Conclusions: With electrical stimulation in the sclera of the peripheral cornea, asymmetric mydriasis in cat eyes and symmetrical miosis in porcine eyes were observed. Under the assumption that the electrical stimulation stimulated both muscles that contribute to the pupil control, our hypothesis proposed here is that the pupil dilator is stronger than the pupil sphincter in cat, and pupil sphincter is stronger than pupil dilator in porcine.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: We have reported that the changes in the accommodative response to electrical stimulation of the branches of the ciliary nerves in cats. (Miyagawa et al, PLoS One, 2014). We have also reported that no robust accommodative responses to the electrical stimulations of the sclera of peripheral cornea (SSPC) were observed in enucleated porcine eyes (Mihashi et al, VPOptics, 2014). In this study, accommodative responses to SSPC stimulation in cats and porcines were investigated. Methods: Two eyes of two cats under anesthesia and after they were sacrificed were studied. Three enucleated porcine eyes obtained from a local slaughterhouse were also studied. Trains of biphasic pulses (current, 3 mA; duration, 2 ms/phase; frequency, 40 Hz) were applied using a tungsten electrode (0.3mm diameter) from several orientations. Wavefront sensing with a compact wavefront aberrometer (Uday et al J Cataract Refract Surg, 2013) were performed before and 4 s (cat) and 10 s (pig) after the stimulations and wavefront aberrations including spherical errors were analyzed over a 4-mm pupil area. Results: In the first cat under anesthesia, at three out of seven stimulus positions, 0.2 D hyperopic accommodative responses were observed and in two orientations, myopic responses were observed. For the other cat, weak accommodative responses including astigmatic changes were observed. In the sacrificed condition of the second cat, 0.1 D myopic response was observed for one stimulus orientation and the smaller responses were observed at six out of eight stimulus positions. No accommodative responses were elicited for the enucleated porcine eyes. Conclusions: In the anesthetized cats, electrical stimulation of the SSPC induced accommodative responses; the responses were unstable and weaker than the responses by the ciliary nerve stimulations we observed in our previous study. Small accommodative responses were observed after one of two cats had been sacrificed, but no accommodative responses were detected in the enucleated porcine eyes. Further studies are needed to confirm difference in the accommodation functions in the two species.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose: To investigate associations between the diurnal variation in a range of corneal parameters, including anterior and posterior corneal topography, and regional corneal thickness. ----- Methods: Fifteen subjects had their corneas measured using a rotating Scheimpflug camera (Pentacam) every 3-7 hours over a 24-hour period. Anterior and posterior corneal axial curvature, pachymetry and anterior chamber depth were analysed. The best fitting corneal sphero-cylinder from the axial curvature, and the average corneal thickness for a series of different corneal regions were calculated. Intraocular pressure and axial length were also measured at each measurement session. Repeated measures ANOVA were used to investigate diurnal change in these parameters. Analysis of covariance was used to examine associations between the measured ocular parameters. ----- Results: Significant diurnal variation was found to occur in both the anterior and posterior corneal curvature and in the regional corneal thickness. Flattening of the anterior corneal best sphere was observed at the early morning measurement (p < 0.0001). The posterior cornea also underwent a significant steepening (p < 0.0001) and change in astigmatism 90/180° at this time. A significant swelling of the cornea (p < 0.0001) was also found to occur immediately after waking. Highly significant associations were found between the diurnal variation in corneal thickness and the changes in corneal curvature. ----- Conclusions: Significant diurnal variation occurs in the regional thickness and the shape of the anterior and posterior cornea. The largest changes in the cornea were typically evident upon waking. The observed non-uniform regional corneal thickness changes resulted in a steepening of the posterior cornea, and a flattening of the anterior cornea to occur at this time.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Abstract—Corneal topography estimation that is based on the Placido disk principle relies on good quality of precorneal tear film and sufficiently wide eyelid (palpebral) aperture to avoid reflections from eyelashes. However, in practice, these conditions are not always fulfilled resulting in missing regions, smaller corneal coverage, and subsequently poorer estimates of corneal topography. Our aim was to enhance the standard operating range of a Placido disk videokeratoscope to obtain reliable corneal topography estimates in patients with poor tear film quality, such as encountered in those diagnosed with dry eye, and with narrower palpebral apertures as in the case of Asian subjects. This was achieved by incorporating in the instrument’s own topography estimation algorithm an image processing technique that comprises a polar-domain adaptive filter and amorphological closing operator. The experimental results from measurements of test surfaces and real corneas showed that the incorporation of the proposed technique results in better estimates of corneal topography, and, in many cases, to a significant increase in the estimated coverage area making such an enhanced videokeratoscope a better tool for clinicians.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A new method for noninvasive assessment of tear film surface quality (TFSQ) is proposed. The method is based on high-speed videokeratoscopy in which the corneal area for the analysis is dynamically estimated in a manner that removes videokeratoscopy interference from the shadows of eyelashes but not that related to the poor quality of the precorneal tear film that is of interest. The separation between the two types of seemingly similar videokeratoscopy interference is achieved by region-based classification in which the overall noise is first separated from the useful signal (unaltered videokeratoscopy pattern), followed by a dedicated interference classification algorithm that distinguishes between the two considered interferences. The proposed technique provides a much wider corneal area for the analysis of TFSQ than the previously reported techniques. A preliminary study with the proposed technique, carried out for a range of anterior eye conditions, showed an effective behavior in terms of noise to signal separation, interference classification, as well as consistent TFSQ results. Subsequently, the method proved to be able to not only discriminate between the bare eye and the lens on eye conditions but also to have the potential to discriminate between the two types of contact lenses.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

High-speed videokeratoscopy is an emerging technique that enables study of the corneal surface and tear-film dynamics. Unlike its static predecessor, this new technique results in a very large amount of digital data for which storage needs become significant. We aimed to design a compression technique that would use mathematical functions to parsimoniously fit corneal surface data with a minimum number of coefficients. Since the Zernike polynomial functions that have been traditionally used for modeling corneal surfaces may not necessarily correctly represent given corneal surface data in terms of its optical performance, we introduced the concept of Zernike polynomial-based rational functions. Modeling optimality criteria were employed in terms of both the rms surface error as well as the point spread function cross-correlation. The parameters of approximations were estimated using a nonlinear least-squares procedure based on the Levenberg-Marquardt algorithm. A large number of retrospective videokeratoscopic measurements were used to evaluate the performance of the proposed rational-function-based modeling approach. The results indicate that the rational functions almost always outperform the traditional Zernike polynomial approximations with the same number of coefficients.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Aberrations affect image quality of the eye away from the line of sight as well as along it. High amounts of lower order aberrations are found in the peripheral visual field and higher order aberrations change away from the centre of the visual field. Peripheral resolution is poorer than that in central vision, but peripheral vision is important for movement and detection tasks (for example driving) which are adversely affected by poor peripheral image quality. Any physiological process or intervention that affects axial image quality will affect peripheral image quality as well. The aim of this study was to investigate the effects of accommodation, myopia, age, and refractive interventions of orthokeratology, laser in situ keratomileusis and intraocular lens implantation on the peripheral aberrations of the eye. This is the first systematic investigation of peripheral aberrations in a variety of subject groups. Peripheral aberrations can be measured either by rotating a measuring instrument relative to the eye or rotating the eye relative to the instrument. I used the latter as it is much easier to do. To rule out effects of eye rotation on peripheral aberrations, I investigated the effects of eye rotation on axial and peripheral cycloplegic refraction using an open field autorefractor. For axial refraction, the subjects fixated at a target straight ahead, while their heads were rotated by ±30º with a compensatory eye rotation to view the target. For peripheral refraction, the subjects rotated their eyes to fixate on targets out to ±34° along the horizontal visual field, followed by measurements in which they rotated their heads such that the eyes stayed in the primary position relative to the head while fixating at the peripheral targets. Oblique viewing did not affect axial or peripheral refraction. Therefore it is not critical, within the range of viewing angles studied, if axial and peripheral refractions are measured with rotation of the eye relative to the instrument or rotation of the instrument relative to the eye. Peripheral aberrations were measured using a commercial Hartmann-Shack aberrometer. A number of hardware and software changes were made. The 1.4 mm range limiting aperture was replaced by a larger aperture (2.5 mm) to ensure all the light from peripheral parts of the pupil reached the instrument detector even when aberrations were high such as those occur in peripheral vision. The power of the super luminescent diode source was increased to improve detection of spots passing through the peripheral pupil. A beam splitter was placed between the subjects and the aberrometer, through which they viewed an array of targets on a wall or projected on a screen in a 6 row x 7 column matrix of points covering a visual field of 42 x 32. In peripheral vision, the pupil of the eye appears elliptical rather than circular; data were analysed off-line using custom software to determine peripheral aberrations. All analyses in the study were conducted for 5.0 mm pupils. Influence of accommodation on peripheral aberrations was investigated in young emmetropic subjects by presenting fixation targets at 25 cm and 3 m (4.0 D and 0.3 D accommodative demands, respectively). Increase in accommodation did not affect the patterns of any aberrations across the field, but there was overall negative shift in spherical aberration across the visual field of 0.10 ± 0.01m. Subsequent studies were conducted with the targets at a 1.2 m distance. Young emmetropes, young myopes and older emmetropes exhibited similar patterns of astigmatism and coma across the visual field. However, the rate of change of coma across the field was higher in young myopes than young emmetropes and was highest in older emmetropes amongst the three groups. Spherical aberration showed an overall decrease in myopes and increase in older emmetropes across the field, as compared to young emmetropes. Orthokeratology, spherical IOL implantation and LASIK altered peripheral higher order aberrations considerably, especially spherical aberration. Spherical IOL implantation resulted in an overall increase in spherical aberration across the field. Orthokeratology and LASIK reversed the direction of change in coma across the field. Orthokeratology corrected peripheral relative hypermetropia through correcting myopia in the central visual field. Theoretical ray tracing demonstrated that changes in aberrations due to orthokeratology and LASIK can be explained by the induced changes in radius of curvature and asphericity of the cornea. This investigation has shown that peripheral aberrations can be measured with reasonable accuracy with eye rotation relative to the instrument. Peripheral aberrations are affected by accommodation, myopia, age, orthokeratology, spherical intraocular lens implantation and laser in situ keratomileusis. These factors affect the magnitudes and patterns of most aberrations considerably (especially coma and spherical aberration) across the studied visual field. The changes in aberrations across the field may influence peripheral detection and motion perception. However, further research is required to investigate how the changes in aberrations influence peripheral detection and motion perception and consequently peripheral vision task performance.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose: All currently considered parametric models used for decomposing videokeratoscopy height data are viewercentered and hence describe what the operator sees rather than what the surface is. The purpose of this study was to ascertain the applicability of an object-centered representation to modeling of corneal surfaces. Methods: A three-dimensional surface decomposition into a series of spherical harmonics is considered and compared with the traditional Zernike polynomial expansion for a range of videokeratoscopic height data. Results: Spherical harmonic decomposition led to significantly better fits to corneal surfaces (in terms of the root mean square error values) than the corresponding Zernike polynomial expansions with the same number of coefficients, for all considered corneal surfaces, corneal diameters, and model orders. Conclusions: Spherical harmonic decomposition is a viable alternative to Zernike polynomial decomposition. It achieves better fits to videokeratoscopic height data and has the advantage of an object-centered representation that could be particularly suited to the analysis of multiple corneal measurements.