879 resultados para Controller medications


Relevância:

20.00% 20.00%

Publicador:

Resumo:

This chapter focuses on the implementation of the TS (Tagaki-Sugino) fuzzy controller for the Doubly Fed Induction Generator (DFIG) based wind generator. The conventional PI control loops for mantaining desired active power and DC capacitor voltage is compared with the TS fuzzy controllers. DFIG system is represented by a third-order model where electromagnetic transients of the stator are neglected. The effectiveness of the TS-fuzzy controller on the rotor speed oscillations and the DC capacitor voltage variations of the DFIG damping controller on converter ratings is also investigated. The results from the time domain simulations are presented to elucidate the effectiveness of the TS-fuzzy controller over the conventional PI controller in the DFIG system. The proposed TS-fuzzy con-troller can improve the fault ride through capability of DFIG compared to the conventional PI controller.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Displacement of conventional synchronous generators by non-inertial units such as wind or solar generators will result in reduced-system inertia affecting under-frequency response. Frequency control is important to avoid equipment damage, load shedding, and possible blackouts. Wind generators along with energy storage systems can be used to improve the frequency response of low-inertia power system. This paper proposes a fuzzy-logic based frequency controller (FFC) for wind farms augmented with energy storage systems (wind-storage system) to improve the primary frequency response in future low-inertia hybrid power system. The proposed controller provides bidirectional real power injection using system frequency deviations and rate of change of frequency (RoCoF). Moreover, FFC ensures optimal use of energy from wind farms and storage units by eliminating the inflexible de-loading of wind energy and minimizing the required storage capacity. The efficacy of the proposed FFC is verified on the low-inertia hybrid power system.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Hypertension is a health problem that has increasing prevalence worldwide. Antihypertensive medications are the key for achieving controlled blood pressure. Little is known about predictors of antihypertensive medications adherence in Saudi Arabia. This is a cross-sectional study of 308 participants from a general hospital in Jeddah city, Saudi Arabia conducted between July 2013 and February 2014. Out of the 308 participants, the results showed that 27.9% were classified as perfect adherents and 72.1% were classified as non-perfect adherents to antihypertensive medications. Significant predictors of non-perfect antihypertensive medications in this study were having non-formal education (p=0.031, OR=2.3, 95%CI = [1.82-5]), reporting a poor relationship with physicians (p=0.004, OR=2.25, 95%CI= [1.29-3.9]), and having no co-morbidities (p=0.048, OR=1.86, 95%CI [1.00-3.46]). The outcome of this study highlights the need for policies and interventions that enhance the level of formal education at a population level and improve physician-patient relationships in health care settings.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper presents an off-line (finite time interval) and on-line learning direct adaptive neural controller for an unstable helicopter. The neural controller is designed to track pitch rate command signal generated using the reference model. A helicopter having a soft inplane four-bladed hingeless main rotor and a four-bladed tail rotor with conventional mechanical controls is used for the simulation studies. For the simulation study, a linearized helicopter model at different straight and level flight conditions is considered. A neural network with a linear filter architecture trained using backpropagation through time is used to approximate the control law. The controller network parameters are adapted using updated rules Lyapunov synthesis. The off-line trained (for finite time interval) network provides the necessary stability and tracking performance. The on-line learning is used to adapt the network under varying flight conditions. The on-line learning ability is demonstrated through parameter uncertainties. The performance of the proposed direct adaptive neural controller (DANC) is compared with feedback error learning neural controller (FENC).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A microcontroller based, thermal energy meter cum controller (TEMC) suitable for solar thermal systems has been developed. It monitors solar radiation, ambient temperature, fluid flow rate, and temperature of fluid at various locations of the system and computes the energy transfer rate. It also controls the operation of the fluid-circulating pump depending on the temperature difference across the solar collector field. The accuracy of energy measurement is +/-1.5%. The instrument has been tested in a solar water heating system. Its operation became automatic with savings in electrical energy consumption of pump by 30% on cloudy days.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Given a plant P, we consider the problem of designing a pair of controllers C1 and C2 such that their sum stabilizes P, and in addition, each of them also stabilizes P should the other one fail. This is referred to as the reliable stabilization problem. It is shown that every strongly stabilizable plant can be reliably stabilized; moreover, one of the two controllers can be specified arbitrarily, subject only to the constraint that it should be stable. The stabilization technique is extended to reliable regulation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This report describes the development and simulation of a variable rate controller for a 6-degree of freedom nonlinear model. The variable rate simulation model represents an off the shelf autopilot. Flight experiment involves risks and can be expensive. Therefore a dynamic model to understand the performance characteristics of the UAS in mission simulation before actual flight test or to obtain parameters needed for the flight is important. The control and guidance is implemented in Simulink. The report tests the use of the model for air search and air sampling path planning. A GUI in which a set of mission scenarios, in which two experts (mission expert, i.e. air sampling or air search and an UAV expert) interact, is presented showing the benefits of the method.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The purpose of this study was to establish a three-dimensional fluorescent tooth model to investigate bacterial viability against intra-canal medicaments across the thickness and surface of root dentine. Dental microbial biofilms (Enterococcus faecalis and Streptococcus mutans) were established on the external root surface and bacterial kill was monitored over time against intra-canal medicament (Ca(OH)2 ) using fluorescent microscopy in conjunction with BacLight SYTO9 and propidium iodide stains. An Olympus digital camera fitted to SZX16 fluorescent microscope captured images of bacterial cells in biofilms on the external root surface. Viability of biofilm was measured by calculating the total pixel area of green (viable bacteria) and red (non-viable bacteria) for each image using ImageJ® software. All data generated were assessed for normality and then analysed using a Mann-Whitney t-test. The viability of S. mutans biofilm following Ca(OH)2 treatment showed a significant decline compared with the untreated group (P = 0.0418). No significant difference was seen for E. faecalis biofilm between the Ca(OH)2 and untreated groups indicating Ca(OH)2 medicament is ineffective against E. faecalis biofilm. This novel three-dimensional fluorescent biofilm model provides a new clinically relevant tool for testing of medicaments against dental biofilms.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The international traveller needs to plan ahead to ensure medicines are available and used as directed for optimal therapeutic outcome. The planning needs to take account of legal and customs requirements for travelling with medicines for personal use. The standard advice by travel health providers is that travellers should check with the country of destination for requirements when travelling into the country with medicines for personal use. This is akin to introducing a barrier to care for this category of travellers. Innovative method of care for this group of traveller is needed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Aim Frail older people typically suffer several chronic diseases, receive multiple medications and are more likely to be institutionalized in residential aged care facilities. In such patients, optimizing prescribing and avoiding use of high-risk medications might prevent adverse events. The present study aimed to develop a pragmatic, easily applied algorithm for medication review to help clinicians identify and discontinue potentially inappropriate high-risk medications. Methods The literature was searched for robust evidence of the association of adverse effects related to potentially inappropriate medications in older patients to identify high-risk medications. Prior research into the cessation of potentially inappropriate medications in older patients in different settings was synthesized into a four-step algorithm for incorporation into clinical assessment protocols for patients, particularly those in residential aged care facilities. Results The algorithm comprises several steps leading to individualized prescribing recommendations: (i) identify a high-risk medication; (ii) ascertain the current indications for the medication and assess their validity; (iii) assess if the drug is providing ongoing symptomatic benefit; and (iv) consider withdrawing, altering or continuing medications. Decision support resources were developed to complement the algorithm in ensuring a systematic and patient-centered approach to medication discontinuation. These include a comprehensive list of high-risk medications and the reasons for inappropriateness, lists of alternative treatments, and suggested medication withdrawal protocols. Conclusions The algorithm captures a range of different clinical scenarios in relation to potentially inappropriate medications, and offers an evidence-based approach to identifying and, if appropriate, discontinuing such medications. Studies are required to evaluate algorithm effects on prescribing decisions and patient outcomes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this paper the problem of stabilization of systems by means of stable compensations is considered, and results are derived for systems using observer�controller structures, for systems using a cascade structure, and for nonlinear systems

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Acetaminophen (paracetamol) is available in a wide range of oral formulations designed to meet the needs of the population across the age-spectrum, but for people with impaired swallowing, i.e. dysphagia, both solid and liquid medications can be difficult to swallow without modification. The effect of a commercial polysaccharide thickener, designed to be added to fluids to promote safe swallowing by dysphagic patients, on rheology and acetaminophen dissolution was tested using crushed immediate-release tablets in water, effervescent tablets in water, elixir and suspension. The inclusion of the thickener, comprised of xanthan gum and maltodextrin, had a considerable impact on dissolution; acetaminophen release from modified medications reached 12-50% in 30 minutes, which did not reflect the pharmacopeia specification for immediate release preparations. Flow curves reflect the high zero-shear viscosity and the apparent yield stress of the thickened products. The weak gel nature, in combination with high G’ values compared to G” (viscoelasticity) and high apparent yield stress, impact drug release. The restriction on drug release from these formulations is not influenced by the theoretical state of the drug (dissolved or dispersed), and the approach typically used in clinical practice (mixing crushed tablets into pre-prepared thickened fluid) cannot be improved by altering the order of incorporation or mixing method.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A simple, low-cost, constant frequency, analog controller is proposed for the front-end half-bridge rectifier of a single-phase transformerless UPS system to maintain near unity power factor at the input and zero dc-offset voltage at the output. The controller generates the required gating pulses by comparing the input current with a periodic, bipolar, linear carrier without sensing the input voltage. Two voltage controllers and a single integrator with reset are used to generate the required carrier. All the necessary control operations can be performed without using any PLL, multiplier and/or divider. The controller can be fabricated as a single integrated circuit. The control concept is validated through simulation and also experimentally on an 800W half-bridge rectifier. Experimental results are presented for ac-dc application, and also for ac-dc-ac UPS application with both sinusoidal and nonlinear loads. The simulation and experimental results agree well.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A new solution for unbalanced and nonlinear loads in terms of power circuit topology and controller structure is proposed in this paper. A three-phase four-wire high-frequency ac-link inverter is adopted to cater to such loads. Use of high-frequency transformer results in compact and light-weight systems. The fourth wire is taken out from the midpoint of the isolation transformer in order to avoid the necessity of an extra leg. This makes the converter suitable for unbalanced loads and eliminates the requirements of bulky capacitor in half-bridge inverter. The closed-loop control is carried out in stationary reference frame using proportional + multiresonant controller (three separate resonant controller for fundamental, fifth and seventh harmonic components). The limitations on improving steady-state response of harmonic resonance controllers is investigated and mitigated using a lead-lag compensator. The proposed voltage controller is used along with an inner current loop to ensure excellent performance of the power converter. Simulation studies and experimental results with 1 kVA prototype under nonlinear and unbalanced loading conditions validate the proposed scheme.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A design methodology for wave-absorbing active material system is reported. The design enforces equivalence between an assumed material model having wave-absorbing behavior and a set of target feedback controllers for an array of microelectro-mechanical transducers which are integral part of the active material system. The proposed methodology is applicable to problems involving the control of acoustic waves in passive-active material system with complex constitutive behavior at different length-scales. A stress relaxation type one-dimensional constitutive model involving viscous damping mechanism is considered, which shows asymmetric wave dispersion characteristics about the half-line. The acoustic power flow and asymptotic stability of such material system are studied. A single sensor non-collocated linear feedback control system in a one-dimensional finite waveguide, which is a representative volume element in an active material system, is considered. Equivalence between the exact dynamic equilibrium of these two systems is imposed. It results in the solution space of the design variables, namely the equivalent damping coefficient, the wavelength(s) to be controlled and the location of the sensor. The characteristics of the controller transfer functions and their pole-placement problem are studied. (c) 2005 Elsevier Ltd. All rights reserved.