442 resultados para Conjunctival swab


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: To compare the frequency of conjunctival HLA-DR expression (a surrogate marker for inflammation) in eyes treated with topical prostaglandin analogues versus eyes treated with other topical antiglaucomatous drugs. METHODS: Patients diagnosed with primary open-angle glaucoma presenting indication for trabeculectomy were divided in groups according to the use or not of prostaglandin analogues. All subjects were treated with the maximum tolerated dose of antiglaucomatous drugs until the date of the surgery. At the beginning of the surgical procedure, a 5 x 5 mm biopsy of the bulbar conjunctiva was collected, incubated with monoclonal anti-HLA-DR antibody and processed for histological analysis. RESULTS: Of the 31 eyes included (31 patients), 25 were under topical prostaglandin analogues (Group 1) and six under other topical pharmacological agents (Group 2). Fourteen eyes of Group 1 (56%) and three of Group 2 (50 %) were positive for the inflammatory marker HLA-DR (P=1.0). The percentage of stained cells ranged from 15.49 to 48.09% (median: 27.61) in Group 1, and from 18.35 to 28 (median: 20.71) in Group 2, with no differences statistically significant (p=0.33). CONCLUSION: The use of prostaglandin analogues did not increase conjunctival expression of HLA-DR compared to other topical antiglaucomatous agents.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: To evaluate the effectiveness and safety of postoperative low single-dose of beta-irradiation (beta-RT) in pterygium comparing conjunctival autograft (CAG) surgery with CAG plus adjuvant beta-RT in a randomized clinical trial. Methods: This trial was designed as a prospective, randomized, single-center study. Surgery was performed in all cases according to the CAG technique. One hundred and eight pterygia were post-operatively randomized to CAG + beta-RT or CAGalone. In the case of beta-RT, a (90) Sr eye applicator was used to deliver 10 Gy to the sclera surface at a dose rate of between 200 and 250 cGy/min. After treatment, both an ophthalmologist and a radiation oncologist performed the follow-up examinations. The accumulated data were analyzed using a group sequential test. Results: Between February 2008 and September 2008, 116 eyes with primary pterygium were operated on according to the trial protocol. Adjuvant treatment was performed within 24 h post-operatively. Eight patients were lost to follow-up, resulting in 108 patients who could be analyzed. At a mean follow-up of 18 months (range, 8-33), in the 54 eyes randomized to receive CAG + beta-RT, 5 relapses occurred compared with 12 recurrences in the 54 eyes in CAG, for a crude control rate of 90.8 % vs. 78%; p = 0.032, respectively. The treatment complications as hyperemia, total dehiscence of the autograft and dellen were significantly more frequent in the CAG (p < 0.05). The arm of beta-RT resulted in better cosmetic results and improves of symptoms than CAG. Conclusions: A low single-dose of beta-RT of 10 Gy after CAG surgery was a simple, effective, and safe treatment that reduced the risk of primary pterygium recurrence, improved symptoms after surgery, resulting in a better cosmetic effect than only CAG. (C) 2012 Elsevier Inc.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Electrophysiological cardiac devices are increasingly used. The frequency of subclinical infection is unknown. We investigated all explanted devices using sonication, a method for detection of microbial biofilms on foreign bodies.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE To report a case of conjunctival proliferation in a 2.5-year-old boy after initial evidence of a mild chemical injury after ocular exposure to pepper spray (oleoresin capsicum). METHODS Case report with ophthalmologic and histologic findings. RESULTS A child presented with mild conjunctival injection and chemosis without any corneal erosion after direct exposure to pepper spray. Three weeks later, a significant conjunctival proliferation was found at the limbus, which was refractory to treatment with topical corticosteroids. Finally, proliferative tissue was surgically excised without clinical recurrence during 2 months of follow-up. CONCLUSIONS We hypothesize that the young age of the patient may have been an important factor for the severe conjunctival proliferation in comparison to a mainly uncomplicated course of pepper spray injuries in most adults. We recommend the use of topical antiinflammatory treatment even in apparently mild pepper spray injuries, especially in young children.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: We wished to investigate the toxicity of four immunosuppressant and antimetabolic drugs, which are known to influence postoperative wound healing, on three different human ocular cell lines. METHODS: Acute toxicity to cyclosporin A, azathioprine, mitomicyn C and daunorubicin was assessed in Chang cells by monitoring their uptake of propidium iodide during a 3-h period. Chronic toxicity was assessed by monitoring the proliferation and viability of subconfluent cultures of Chang cells, human corneal endothelial cells (HCECs) and retinal pigmented epithelial (RPE) cells after continuous exposure to the drugs for 7 days. RESULTS: Acute toxicity testing revealed no obvious effects. However, the chronic toxicity tests disclosed a narrow concentration range over which cell proliferation decreased dramatically but calcein metabolism was sustained. Although the three lines reacted similarly to each agent, HCECs were the most vulnerable to daunorubicin and mitomycin. At a daunorubicin concentration of 0.05 microg/ml, a 75% decrease in calcein metabolism (P < 0.001) and a > or = 95% cell loss (P < 0.001) were observed. At a mitomycin concentration of 0.01 mug/ml, cell density decreased by 61% (P < 0.001) without a change in calcein metabolism, but at 0.1 microg/ml, the latter parameter decreased to 12% (P = 0.00014). At this concentration the proliferation of Chang and RPE cells decreased by more than 50%, whilst calcein metabolism was largely sustained. Cyclosporin inhibited cell proliferation moderately at lower concentrations (< 5 microg/ml; P=0.05) and substantially at higher ones, with a corresponding decline in calcein metabolism. Azathioprine induced a profound decrease in both parameters at concentrations above 5 microg/ml. CONCLUSION: Daunorubicin, cyclosporin and azathioprine could be used to inhibit excessive intraocular scarring after glaucoma and vitreoretinal surgery without overly reducing cell viability. The attributes of immunosuppressants lie in their combined antiproliferative and immunomodulatory effects.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Screening for chlamydia in women is widely recommended. We evaluated the performance of two nucleic acid amplification tests for detecting Chlamydia trachomatis in self-collected vulvovaginal-swab and first-catch urine specimens from women in a community setting and a strategy for optimizing the sensitivity of an amplified enzyme immunoassay on vulvovaginal-swab specimens. We tested 2,745 paired vulvovaginal-swab and urine specimens by PCR (Roche Cobas) or strand displacement amplification (SDA; Becton Dickinson). There were 146 women infected with chlamydia. The assays detected 97.3% (95% confidence interval [CI], 93.1 to 99.2%) of infected patients with vulvovaginal-swab specimens and 91.8% (86.1 to 95.7%) with urine specimens. We tested 2,749 vulvovaginal-swab specimens with both a nucleic acid amplification test and a polymer conjugate-enhanced enzyme immunoassay with negative-gray-zone testing. The relative sensitivities obtained after retesting specimens in the negative gray zone were 74.3% (95% CI, 62.8 to 83.8%) with PCR and 58.3% (95% CI, 46.1 to 69.8%) with SDA. In community settings, both vulvovaginal-swab and first-catch urine specimens from women are suitable substrates for nucleic acid amplification tests, but enzyme immunoassays, even after negative-gray-zone testing, should not be used in screening programs.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Known causes of conjunctival salmon patches include lymphoma, amyloidosis, sarcoidosis, leukaemia and benign reactive lymphoid hyperplasia. The aetiology of benign reactive lymphoid hyperplasia is thought to be a localized reactive change induced by an irritative or antigenic stimulus. The case of benign reactive lymphoid hyperplasia reported herein occurred in a myopic patient with extremely thin sclera. The authors' hypothesis is that choroidal antigens are able to perfuse through thin sclera and act as chronic irritants to the overlying conjunctiva resulting in a lymphoid response and subsequent salmon patch formation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose. To report differences in the incidence of conjunctival epithelial flaps (CEFs) found in a group of neophyte contact wearers using two different silicone hydrogel contact lenses on a daily- and continuous-wear basis during an 18-month period. Methods. Sixty-one subjects were initially examined, and 53 were eligible to participate in the study. Eligible subjects were randomly assigned to wear one of two silicone hydrogel materials, lotrafilcon A or balafilcon A, on a daily- or continuous-wear basis. After an initial screening, subjects were monitored weekly for the first month and then after 3, 6, 12, and IS months. The incidence of CEFs in each of the four contact lens groups was recorded. Results. Five of the 53 subjects enrolled in the study showed bilateral CEFs. A higher incidence of CEFs was found in subjects wearing lotrafilcon A lenses (n = 4) compared to balafilcon A lenses (it = 1) (chi(2) = 4.37, P=0.04). Differences in the incidence of CEFs between subjects wearing lenses on a daily-wear basis (n = 1) versus a continuous-wear basis (it = 4) showed a weak statistical significance (chi(2) = 3.03, P=0.08). Conclusions. Lotrafilcon A lenses were associated with a higher incidence of CEFs than balafilcon A lenses were, and this difference may be attributed to differences in the edge design, material, or modulus of rigidity between the two lens types. Subjects wearing lenses on a daily-wear basis showed fewer adverse events than did subjects wearing lenses on a continuous-wear basis. The longer wearing times of subjects wearing lenses on a continuous-wear basis are likely to exacerbate the incidence of CEFs.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

DUE TO COPYRIGHT RESTRICTIONS ONLY AVAILABLE FOR CONSULTATION AT ASTON UNIVERSITY LIBRARY AND INFORMATION SERVICES WITH PRIOR ARRANGEMENT

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: Autofluorescence of ultraviolet (UV) light has been shown to occur in localised areas of the bulbar conjunctiva, which map to active cellular changes due to UV and environmental exposure. This study examined the presence of conjunctival UV autofluorescence in eye care practitioners (ECPs) across Europe and the Middle East and its associated risk factors. Method: Images were captured of 307 ECPs right eyes in the Czech Republic, Germany, Greece, Kuwait, Netherlands, Sweden, Switzerland, United Arab Emirates and the United Kingdom using a Nikon D100 camera and dual flash units through UV filters. UV autofluorescence was outlined using ImageJ software and the nasal and temporal area quantified. Subjects were required to complete a questionnaire on their demographics and lifestyle including general exposure to UV and refractive correction. Results: Average age of the subjects was 38.5±12.2 years (range 19-68) and 39.7% were male. Sixty-two percent of eyes had some conjunctival damage as indicated by UV autofluorescence. The average area of damage was higher (p=0.005) nasally (2.95±4.52mm2) than temporally (2.19±4.17mm2). The area of UV damage was not related to age (r=0.03, p=0.674), gender (p=0.194), self-reported sun exposure lifestyle (p>0.05), geographical location (p=0174), sunglasses use (p>0.05) or UV-blocking contact lens use (p>0.05), although it was higher in those wearing contact lenses with minimal UV-blocking and no spectacles (p=0.015). The area of UV damage was also less nasally in those who wore contact lenses and spectacles compared to those with no refractive correction use (p=0.011 nasal; p=0.958 temporal). Conclusion: UV conjunctival damage is common even in Europe, Kuwait and UAE, and among ECPs. The area of damage appears to be linked with the use of refractive correction, with greater damage nasally than temporally which may be explained by the peripheral light focusing effect.