915 resultados para Concrete railroad ties Safety measures


Relevância:

100.00% 100.00%

Publicador:

Resumo:

A prestressed concrete monoblock railroad tie was designed to attend the characteristics of a Brazilian railroad track with 1,600 mm gauge and 320 kN axle load. Concrete ties specimens were manufactured without and with steel fibers in a volume fraction of 60 kg/m3 (0.76 % by volume), and three different initial prestress forces. Static and fatigue tests were carried out on the ties. Static tests showed that steel fibers increase the first crack and ultimate bending moments, increase significantly the slip force of the prestressing tendons, reduce crack width, add higher ductility to the ties and decrease the stress in the prestressing tendons. Under dynamic loading the steel fibers decreased the stress in the prestressing tendons by about 50%, which improved significantly the fatigue strength of the tie. A tie without fibers failed after only 150,000 cycles. However, a similar tie, with fibers, resisted 3,000,000 cycles without suffering fatigue failure.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This issue of the FAL Bulletin examines road safety performance in Latin America and the Caribbean between 2000 and 2010. It also sets out the need for road safety measures to be incorporated into an integrated and sustainable mobility policy.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Traditional measures or indicators of workplace safety performance reflect unrecognized hazards, unsafe conditions, reckless behavior, and other safety program shortcomings only after a worker is injured or falls ill. In contrast to traditional or lagging indicators, leading indicators can predict poor safety performance to ensure that safety program failings are addressed before an occupational injury or illness actually occurs. This Capstone Project identified a variety of proactive safety management practices, policies, and activities shown to have a positive impact on workplace safety as leading safety indicators. The end result is a comprehensive framework of leading safety indicators that employers can use to proactively gauge safety program performance and address unrecognized hazards, unsafe conditions, reckless behavior, and other safety program deficiencies.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

National Highway Traffic Safety Administration, Office of Program and Demonstration Evaluation, Washington, D.C.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Mode of access: Internet.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Mode of access: Internet.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

National Highway Safety Bureau, Washington, D.C.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Federal Highway Administration, Office of Research, Washington, D.C.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objective: To independently evaluate the impact of the second phase of the Health Foundation's Safer Patients Initiative (SPI2) on a range of patient safety measures. Design: A controlled before and after design. Five substudies: survey of staff attitudes; review of case notes from high risk (respiratory) patients in medical wards; review of case notes from surgical patients; indirect evaluation of hand hygiene by measuring hospital use of handwashing materials; measurement of outcomes (adverse events, mortality among high risk patients admitted to medical wards, patients' satisfaction, mortality in intensive care, rates of hospital acquired infection). Setting: NHS hospitals in England. Participants: Nine hospitals participating in SPI2 and nine matched control hospitals. Intervention The SPI2 intervention was similar to the SPI1, with somewhat modified goals, a slightly longer intervention period, and a smaller budget per hospital. Results: One of the scores (organisational climate) showed a significant (P=0.009) difference in rate of change over time, which favoured the control hospitals, though the difference was only 0.07 points on a five point scale. Results of the explicit case note reviews of high risk medical patients showed that certain practices improved over time in both control and SPI2 hospitals (and none deteriorated), but there were no significant differences between control and SPI2 hospitals. Monitoring of vital signs improved across control and SPI2 sites. This temporal effect was significant for monitoring the respiratory rate at both the six hour (adjusted odds ratio 2.1, 99% confidence interval 1.0 to 4.3; P=0.010) and 12 hour (2.4, 1.1 to 5.0; P=0.002) periods after admission. There was no significant effect of SPI for any of the measures of vital signs. Use of a recommended system for scoring the severity of pneumonia improved from 1.9% (1/52) to 21.4% (12/56) of control and from 2.0% (1/50) to 41.7% (25/60) of SPI2 patients. This temporal change was significant (7.3, 1.4 to 37.7; P=0.002), but the difference in difference was not significant (2.1, 0.4 to 11.1; P=0.236). There were no notable or significant changes in the pattern of prescribing errors, either over time or between control and SPI2 hospitals. Two items of medical history taking (exercise tolerance and occupation) showed significant improvement over time, across both control and SPI2 hospitals, but no additional SPI2 effect. The holistic review showed no significant changes in error rates either over time or between control and SPI2 hospitals. The explicit case note review of perioperative care showed that adherence rates for two of the four perioperative standards targeted by SPI2 were already good at baseline, exceeding 94% for antibiotic prophylaxis and 98% for deep vein thrombosis prophylaxis. Intraoperative monitoring of temperature improved over time in both groups, but this was not significant (1.8, 0.4 to 7.6; P=0.279), and there were no additional effects of SPI2. A dramatic rise in consumption of soap and alcohol hand rub was similar in control and SPI2 hospitals (P=0.760 and P=0.889, respectively), as was the corresponding decrease in rates of Clostridium difficile and meticillin resistant Staphylococcus aureus infection (P=0.652 and P=0.693, respectively). Mortality rates of medical patients included in the case note reviews in control hospitals increased from 17.3% (42/243) to 21.4% (24/112), while in SPI2 hospitals they fell from 10.3% (24/233) to 6.1% (7/114) (P=0.043). Fewer than 8% of deaths were classed as avoidable; changes in proportions could not explain the divergence of overall death rates between control and SPI2 hospitals. There was no significant difference in the rate of change in mortality in intensive care. Patients' satisfaction improved in both control and SPI2 hospitals on all dimensions, but again there were no significant changes between the two groups of hospitals. Conclusions: Many aspects of care are already good or improving across the NHS in England, suggesting considerable improvements in quality across the board. These improvements are probably due to contemporaneous policy activities relating to patient safety, including those with features similar to the SPI, and the emergence of professional consensus on some clinical processes. This phenomenon might have attenuated the incremental effect of the SPI, making it difficult to detect. Alternatively, the full impact of the SPI might be observable only in the longer term. The conclusion of this study could have been different if concurrent controls had not been used.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVE: The discipline of clinical neuropsychiatry currently provides specialised services for a number of conditions that cross the traditional boundaries of neurology and psychiatry, including non-epileptic attack disorder. Neurophysiological investigations have an important role within neuropsychiatry services, with video-electroencephalography (EEG) telemetry being the gold standard investigation for the differential diagnosis between epileptic seizures and non-epileptic attacks. This article reviews existing evidence on best practices for neurophysiology investigations, with focus on safety measures for video-EEG telemetry. METHODS: We conducted a systematic literature review using the PubMed database in order to identify the scientific literature on the best practices when using neurophysiological investigations in patients with suspected epileptic seizures or non-epileptic attacks. RESULTS: Specific measures need to be implemented for video-EEG telemetry to be safely and effectively carried out by neuropsychiatry services. A confirmed diagnosis of non-epileptic attack disorder following video-EEG telemetry carried out within neuropsychiatry units has the inherent advantage of allowing diagnosis communication and implementation of treatment strategies in a timely fashion, potentially improving clinical outcomes and cost-effectiveness significantly. CONCLUSION: The identified recommendations set the stage for the development of standardised guidelines to enable neuropsychiatry services to implement streamlined and evidence-based care pathways.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Accidents are the leading cause of death among children. Compliance with safety measures have been shown to reduce morbidity and mortality in children. However, Hispanic parents and children have not been adequately studied in the literature in regard to trauma and safety habits utilized. In this exploratory-descriptive study, a convenience sample of 48 Hispanic parents were questioned about their child's activities. The purpose was to determine what safety equipment was used during these activities and how often they were used. Responses to an English/Spanish questionnaire were summarized by frequencies and percentages. Findings suggested that these Hispanic children were at risk for injury due to a low percentage of children wearing the necessary protective equipment. Therefore, education must stress consistent use of safety equipment if injuries are to be prevented. ^

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Dans la région de Trois-Rivières (Québec, Canada), plus de 1 000 bâtiments résidentiels et commerciaux montrent de graves problèmes de détérioration du béton. Les problèmes de détérioration sont liés à l’oxydation des sulfures de fer incorporés dans le granulat utilisé pour la confection du béton. Ce projet de doctorat vise à mieux comprendre les mécanismes responsables de la détérioration de béton incorporant des granulats contenant des sulfures de fer, et ce afin de développer une méthodologie pour évaluer efficacement la réactivité potentielle de ce type de granulats. Un examen pétrographique détaillé de carottes de béton extraites de fondations résidentielles montrant différents degré d’endommagement a été réalisé. Le granulat problématique contenant des sulfures de fer a été identifié comme un gabbro à hypersthène incorporant différentes proportions (selon les différentes localisations dans les deux carrières d’origine) de pyrrhotite, pyrite, chalcopyrite et pentlandite. Les produits de réaction secondaires observés dans les échantillons dégradés comprennent des formes minérales de "rouille", gypse, ettringite et thaumasite. Ces observations ont permis de déterminer qu’en présence d’eau et d’oxygène, la pyrrhotite s’oxyde pour former des oxyhydroxides de fer et de l’acide sulfurique qui provoquent une attaque aux sulfates dans le béton. Tout d’abord, la fiabilité de l’approche chimique proposée dans la norme européenne NF EN 12 620, qui consiste à mesurer la teneur en soufre total (ST,% en masse) dans le granulat pour détecter la présence (ou non) de sulfures de fer, a été évaluée de façon critique. Environ 50% (21/43) des granulats testés, représentant une variété de types de roches/lithologies, a montré une ST > 0,10%, montrant qu’une proportion importante de types de roches ne contient pas une quantité notable de sulfure, qui, pour la plupart d’entre eux, sont susceptibles d’être inoffensifs dans le béton. Ces types de roches/granulats nécessiteraient toutefois d’autres tests pour identifier la présence potentielle de pyrrhotite compte tenu de la limite de ST de 0,10 % proposée dans les normes européennes. Basé sur une revue exhaustive de la littérature et de nombreuses analyses de laboratoire, un test accéléré d’expansion sur barres de mortier divisé en deux phases a ensuite été développé pour reproduire, en laboratoire, les mécanismes de détérioration observés à Trois-Rivières. Le test consiste en un conditionnement de 90 jours à 80°C/80% RH, avec 2 cycles de mouillage de trois heures chacun, par semaine, dans une solution d’hypochlorite de sodium (eau de javel) à 6% (Phase I), suivi d’une période pouvant atteindre 90 jours de conditionnement à 4°C/100 % HR (Phase II). Les granulats ayant un potentiel d’oxydation ont présenté une expansion de 0,10 % au cours de la Phase I, tandis que la formation potentielle de thaumasite est détectée par le regain rapide de l’expansion suivi par la destruction des échantillons durant la Phase II. Un test de consommation d’oxygène a également été modifié à partir d’un test de Drainage Minier Acide, afin d’évaluer quantitativement le potentiel d’oxydation des sulfures de fer incorporés dans les granulats à béton. Cette technique mesure le taux de consommation d’oxygène dans la partie supérieure d’un cylindre fermé contenant une couche de matériau compacté afin de déterminer son potentiel d’oxydation. Des paramètres optimisés pour évaluer le potentiel d’oxydation des granulats comprennent une taille de particule inférieure à 150 μm, saturation à 40 %, un rapport de 10 cm d’épaisseur de granulat par 10 cm de dégagement et trois heures d’essai à 22ᵒC. Les résultats obtenus montrent que le test est capable de discriminer les granulats contenant des sulfures de fer des granulats de contrôle (sans sulfures de fer) avec un seuil limite fixé à 5% d’oxygène consommé. Finalement, un protocole d’évaluation capable d’estimer les effets néfastes potentiels des granulats à béton incorporant des sulfures de fer a été proposé. Le protocole est divisé en 3 grandes phases: (1) mesure de la teneur en soufre total, (2) évaluation de la consommation d’oxygène, et (3) un test accéléré d’expansion sur barres de mortier. Des limites provisoires sont proposées pour chaque phase du protocole, qui doivent être encore validées par la mise à l’essai d’un plus large éventail de granulats.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The information contained in this Annual Safety and Security Report is provided to new and prospective students and employees, as well as their families, and all current members of the campus community. It contains Public Safety Services and Programming,Building Threat and Vulnerability Assessment Program,Campus Security authorities, Annual Preparation of Crime Statistics, Disclosure of Crime Statistics, Daily Crime Log, How to Report a Crime, Suspicious Activity or Emergency, Silent Witness Program, Relationship with Local Authorities, Off-Campus Violations & Criminal Activity, Confidential Reporting, Timely Warning Procedures, Emergency Response, Notification and Evacuation Procedures Activation Authority, Available Communications Media, Emergency Notification Tests, Emergency Evacuation Procedures, Shelter-in-Place Procedures,Crime Prevention and Safety Awareness Programs, Emergency Telephones, Access To Facilities, Maintenance of Buildings and Grounds, Alcohol and Other Drugs, Domestic Violence, Dating Violence, Sexual Assault, and Stalking, Sex Offender Registration, Weapons on Campus, Referrals for Disciplinary Action, Crime Information: Definitions and Statistics, Uniform Crime Reporting Definitions, Reporting Areas. Crime Statistics