878 resultados para Computational Delay-Time
Resumo:
This thesis Entitled Electrical switching studies on the thin flims of polyfuran and polyacrylonitrile prepared by plasma polymerisation and vacuum evaporated amorphous silicon.A general introduction to the switching and allied phenomena is presented. Subsequently, developments of switching in thin films are described. The Mott transition is qualitatively presented. The working of a switching transitor is outlined and compared to the switching observed in thin films. Characteristic parameters of switching such as threshold voltage, time response to a, voltage pulse, and delay time are described. The various switching configurations commonly used are discussed. The mechanisms used to explain the switching behaviour like thermal, electrothermal and purely electronic are reviewed. Finally the scope, feasibility and the importance of polymer thin films in switching are highlighted.
Resumo:
Femtosecond pump/probe multiphoton ionization experiments on Na_2 molecules are performed. The dependence of the total Na^+_2 ion signal on the delay time and the intensity of the femtosecond laser pulses is studied in detail. It is observed that molecular vibrational wavepacket motion in different electronic states dominates the time dependence of the ion signal. For higher laser intensities the relative contributions from the A ^1 \summe^+_u and the 2 ^1 \produkt__g states change dramatically, indicating the increasing importance of a two-electron versus a one-electron process. For even stronger fields (10 ^12 W/ cm²) a vibrational wavepacket in the electronic ground state X ^1 \summe^+_g is formed and its dynamics is also observed in the transient Na^+_2 signal. Time-dependent quantum calculations are presented. The theoretical results agree well with the experiment.
Resumo:
The motion of a vibrational wave packet in the bound A(^1 \summe^+_u) electronic state of the sodium dimer is detected in a femtosecond pump/probe molecular beam experiment. For short times harmonic motion is seen in the total ion yield of Na^+_2 as a function of delay time between the two laser pulses. The spreading of the wave packet results in the loss of the periodic variation of the ion signal. For longer delay times (47 ps) the wave packet regains its initial form which is reflected in the revival structure of the Na^+_2 signal. Time-dependent quantum calculations reproduce the measured effects.
Resumo:
In order to explain the speed of Vesicular Stomatitis Virus VSV infections, we develop a simple model that improves previous approaches to the propagation of virus infections. For VSV infections, we find that the delay time elapsed between the adsorption of a viral particle into a cell and the release of its progeny has a very important effect. Moreover, this delay time makes the adsorption rate essentially irrelevant in order to predict VSV infection speeds. Numerical simulations are in agreement with the analytical results. Our model satisfactorily explains the experimentally measured speeds of VSV infections
Resumo:
This thesis work concerns about the Performance evolution of peer to peer networks, where we used different distribution technique’s of peer distribution like Weibull, Lognormal and Pareto distribution process. Then we used a network simulator to evaluate the performance of these three distribution techniques.During the last decade the Internet has expanded into a world-wide network connecting millions of hosts and users and providing services for everyone. Many emerging applications are bandwidth-intensive in their nature; the size of downloaded files including music and videos can be huge, from ten megabits to many gigabits. The efficient use of network resources is thus crucial for the survivability of the Internet. Traffic engineering (TE) covers a range of mechanisms for optimizing operational networks from the traffic perspective. The time scale in traffic engineering varies from the short-term network control to network planning over a longer time period.Here in this thesis work we considered the peer distribution technique in-order to minimise the peer arrival and service process with three different techniques, where we calculated the congestion parameters like blocking time for each peer before entering into the service process, waiting time for a peers while the other peer has been served in the service block and the delay time for each peer. Then calculated the average of each process and graphs have been plotted using Matlab to analyse the results
Resumo:
O trabalho apresenta uma avaliação dos prováveis impactos do escalonamento dos horários das aulas noturnas em uma Universidade. Neste trabalho foi investigada, a preferência dos usuários quanto às possíveis alterações nos horários de entrada de aulas, e os impactos do escalonamento na rede viária no entorno do campus. O trabalho envolveu a construção de diversos cenários de alterações nos horários de início das aulas. Os cenários foram construídos visando atender as preferências da população universitária e reduzir a interferência do pico de chegada de alunos no sistema viário. A avaliação dos impactos destes cenários no tráfego foi realizada através de simulação, com a utilização do modelo TSIS/NETSIM. As análises foram baseadas em dois indicadores de desempenho: a velocidade média e o tempo de atraso médio na rede.
Resumo:
Water injection is the most widely used method for supplementary recovery in many oil fields due to various reasons, like the fact that water is an effective displacing agent of low viscosity oils, the water injection projects are relatively simple to establish and the water availability at a relatively low cost. For design of water injection projects is necessary to do reservoir studies in order to define the various parameters needed to increase the effectiveness of the method. For this kind of study can be used several mathematical models classified into two general categories: analytical or numerical. The present work aims to do a comparative analysis between the results presented by flow lines simulator and conventional finite differences simulator; both types of simulators are based on numerical methods designed to model light oil reservoirs subjected to water injection. Therefore, it was defined two reservoir models: the first one was a heterogeneous model whose petrophysical properties vary along the reservoir and the other one was created using average petrophysical properties obtained from the first model. Comparisons were done considering that the results of these two models were always in the same operational conditions. Then some rock and fluid parameters have been changed in both models and again the results were compared. From the factorial design, that was done to study the sensitivity analysis of reservoir parameters, a few cases were chosen to study the role of water injection rate and the vertical position of wells perforations in production forecast. It was observed that the results from the two simulators are quite similar in most of the cases; differences were found only in those cases where there was an increase in gas solubility ratio of the model. Thus, it was concluded that in flow simulation of reservoirs analogous of those now studied, mainly when the gas solubility ratio is low, the conventional finite differences simulator may be replaced by flow lines simulator the production forecast is compatible but the computational processing time is lower.
Resumo:
Aims: To assess pelvic floor muscle (PFM) strength in women with stress urinary incontinence (SUI) and urge urinary incontinence (UUI).Materials and Methods: 51 women were prospectively divided into two groups, according to the symptoms as SUI (G1 = 22) or UUI (G2 = 29). Demographic data, such as number of pads/ 24 hours, number of micturations/ 24 hours and nocturia, delay time of urgent void (i.e., the time period for which an urgent void could be voluntarily postponed), number of parity and vaginal deliveries were obtained using a clinical questionnaire. Objective urine loss was evaluated by 60-min. Pad Test, subjective urine stream interruption test (UST) and visual survey of perineal contraction. Objective evaluations of PFM were performed in all patients (vaginal manometry).Results: Median of age, mean number of pads/ 24 hours, nocturia and warning time were significantly higher in UUI comparing to SUI group. During UST, 45.45% in G1 and 3.44%, in G2, were able to interrupt the urine stream (p < 0.001). The 60-min. Pad Test was significantly higher in G2 compared to G1 women (2.7 +/- 2.4 vs 1.5 +/- 1.9 respectively, p = 0.049). Objective evaluation of PFM strength was significantly higher in the SUI than in the UUI patients. No statistical difference was observed regarding other studied parameters.Conclusion: Pelvic floor muscle weakness was significantly higher in women with UUI when compared to SUI.
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Pós-graduação em Medicina Veterinária - FCAV
Resumo:
Pós-graduação em Geociências e Meio Ambiente - IGCE
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Pós-graduação em Ciências Cartográficas - FCT
Resumo:
The aim of the present study was to evaluate the microtensile bond strength to dentin (ATBS) of two total-etching adhesives applied with delays of 1-30 s for curing. Fifty extracted molar teeth were used. Occlusal enamel was sectioned to expose flat dentin surface, which was further polished with 600-grit paper for smear layer standardization. The specimens were divided into two groups, G1: Single Bond total-etching adhesive (SB), and G2: Prime & Bond NT total-etching adhesive (PB). Each group was further divided into 5 subgroups according to the delayed light-cure initiation after the adhesive systems application (n=5): Subgroup 1s - 1 s; Subgroup 5s -5 s; Subgroup 10s - 10 s; Subgroup 20s - 20 s; Subgroup 30s - 30 s. Composite resin cones 5 mm height and 10 mm in diameter were fabricated. Specimens were stored in distilled water at 37 degrees C for 24 h and sectioned to obtain 1 x 1 mm(2) transversal specimens. Specimens were thermocycled and mu TBS was measured. Data were submitted to two-way ANOVA (AdhesiveXDelay time) and Tukey's test. The level of significance was set at 5%. The results in mean MPa(+/- SD) for interaction between adhesive and delay time were: PB/1s - 23.82 +/- 2.54a; SB/5s - 19.52 +/- 2.67b; PB/5s - 18.56 +/- 3.06bc; SB/1s - 15.49 +/- 2.69cd; SB/20s - 16.33 +/- 2.55d; SB/10s - 13.88 +/- 1.67d; PB/10s - 11.04 +/- 1.28e; PB/30s - 10.89 +/- 1.31e; PB/20s - 10.24 +/- 2.33e; SB/30s - 9.19 +/- 1.91e. It was concluded that light-cure initiation timing of total-etching adhesives interferes negatively with mu TBS to dentin. (C) 2014 Elsevier Ltd. All rights reserved.
Resumo:
Pulse repetition rates and the number of laser pulses are among the most important parameters that do affect the analysis of solid materials by laser induced breakdown spectroscopy, and the knowledge of their effects is of fundamental importance for suggesting analytical strategies when dealing with laser ablation processes of polymers. In this contribution, the influence of these parameters in the ablated mass and in the features of craters was evaluated in polypropylene and high density polyethylene plates containing pigment-based PbCrO4. Surface characterization and craters profile were carried out by perfilometry and scanning electron microscopy. Area, volume and profile of craters were obtained using Taylor Map software. A laser induced breakdown spectroscopy system consisted of a Q-Switched Nd:YAG laser (1064 nm, 5 ns) and an Echelle spectrometer equipped with ICCD detector were used. The evaluated operating conditions consisted of 10, 25 and 50 laser pulses at 1, 5 and 10 Hz, 250 mJ/pulse (85 J cm(-2)), 2 mu s delay time and 6 mu s integration time gate. Differences in the topographical features among craters of both polymers were observed. The decrease in the repetition rate resulted in irregular craters and formation of edges, especially in polypropylene sample. The differences in the topographical features and ablated masses were attributed to the influence of the degree of crystallinity, crystalline melting temperature and glass transition temperature in the ablation process of the high density polyethylene and polypropylene. It was also observed that the intensities of chromium and lead emission signals obtained at 10 Hz were two times higher than at 5 Hz by keeping the number of laser pulses constant. (C) 2011 Elsevier B. V. All rights reserved.