857 resultados para Compressor unit
Resumo:
OBJECTIVE. To evaluate the effectiveness of the oral application of a 0.12% solution of chlorhexidine for prevention of respiratory tract infections among intensive care unit (ICU) patients. DESIGN. The study design was a double-blind, randomized, placebo-controlled trial. SETTING. The study was performed in an ICU in a tertiary care hospital at a public university. PATIENTS. Study participants comprised 194 patients admitted to the ICU with a prospective length of stay greater than 48 hours, randomized into 2 groups: those who received chlorhexidine (n = 98) and those who received a placebo (n = 96). INTERVENTION. Oral rinses with chlorhexidine or a placebo were performed 3 times a day throughout the duration of the patient`s stay in the ICU. Clinical data were collected prospectively. RESULTS. Both groups displayed similar baseline clinical features. The overall incidence of respiratory tract infections (RR, 1.0 [95% confidence interval [CI], 0.63-1.60]) and the rates of ventilator-associated pneumonia per 1,000 ventilator-days were similar in both experimental and control groups (22.6 vs 22.3; P = .95). Respiratory tract infection-free survival time (7.8 vs 6.9 days; P = .61), duration of mechanical ventilation (11.1 vs 11.0 days; P = .61), and length of stay (9.7 vs 10.4 days; P = .67) did not differ between the chlorhexidine and placebo groups. However, patients in the chlorhexidine group exhibited a larger interval between ICU admission and onset of the first respiratory tract infection (11.3 vs 7.6 days; P = .05). The chances of surviving the ICU stay were similar (RR, 1.08 [95% CI, 0.72-1.63]). CONCLUSION. Oral application of a 0.12% solution of chlorhexidine does not prevent respiratory tract infections among ICU patients, although it may retard their onset.
Resumo:
BACKGROUND: Previous publications have documented the damage caused to red blood cells (RBCs) irradiated with X-rays produced by a linear accelerator and with gamma rays derived from a Cs-137 source. The biologic effects on RBCs of gamma rays from a Co-60 source, however, have not been characterized. STUDY DESIGN AND METHODS: This study investigated the effect of 3000 and 4000 cGy on the in vitro properties of RBCs preserved with preservative solution and irradiated with a cobalt teletherapy unit. A thermal device equipped with a data acquisition system was used to maintain and monitor the blood temperature during irradiation. The device was rotated at 2 r.p.m. in the irradiation beam by means of an automated system. The spatial distribution of the absorbed dose over the irradiated volume was obtained with phantom and thermoluminescent dosimeters (TLDs). Levels of Hb, K+, and Cl- were assessed by spectrophotometric techniques over a period of 45 days. The change in the topology of the RBC membrane was investigated by flow cytometry. RESULTS: Irradiation caused significant changes in the extracellular levels of K+ and Hb and in the organizational structure of the phospholipid bilayer of the RBC membrane. Blood temperature ranged from 2 to 4 degrees C during irradiation. Rotation at 2 r.p.m. distributed the dose homogeneously (92%-104%) and did not damage the RBCs. CONCLUSIONS: The method used to store the blood bags during irradiation guaranteed that all damage caused to the cells was exclusively due to the action of radiation at the doses applied. It was demonstrated that prolonged storage of Co-60-irradiated RBCs results in loss of membrane phospholipids asymmetry, exposing phosphatidylserine (PS) on the cells` surface with a time and dose dependence, which can reduce the in vivo recovery of these cells. A time- and dose-dependence effect on the extracellular K+ and plasma-free Hb levels was also observed. The magnitude of all these effects, however, seems not to be clinically important and can support the storage of irradiated RBC units for at last 28 days.
Resumo:
Blood irradiation can be performed using a dedicated blood irradiator or a teletherapy unit. A thermal device providing appropriate storage conditions during blood components irradiation with a teletherapy unit has been recently proposed. However, the most appropriated volume of the thermal device was not indicated. The goal of this study was to indicate the most appropriated blood volume for irradiation using a teletherapy unit in order to minimize both the dose heterogeneity in the volume and the blood irradiation time using these equipments. Theoretical and experimental methods were used to study the dose distribution in the blood volume irradiated using a linear accelerator and a cobalt-60 therapy machine. The calculation of absorbed doses in the middle plane of cylindrical acrylic volumes was accomplished by a treatment planning system. Experimentally, we also used cylindrical acrylic phantoms and thermoluminescent dosimeters to confirm the calculated doses. The data obtained were represented by isodose curves. We observed that an irradiation volume should have a height of 28 cm and a diameter of 28 cm and a height of 35 cm and a diameter of 35 cm, when the irradiation is to be performed by a linear accelerator and a cobalt-60 teletherapy unit, respectively. Calculated values of relative doses varied from 93% to 100% in the smaller volume, and from 66% to 100% in the largest one. A difference of 5.0%, approximately, was observed between calculated and experimental data. The size of these volumes permits the irradiation of blood bags in only one bath without compromising the homogeneity of the absorbed dose over the irradiated volume. Thus, these irradiation volumes can be recommend to minimize the irradiation time when a teletherapy unit is used to irradiate blood. (C) 2010 Elsevier Ltd. All rights reserved.
Resumo:
The Brazilian emergency system is being reorganized as a hierarchy in the region of Ribeirao Preto, state of Sao Paulo. We found increased occupational risk for tuberculosis in this region tertiary reference center-a nurse technician (Incidence rate [IR] 526.3/100000 inhabitants) had a risk of tuberculosis 12.6 (95% confidence interval [CI], 2.57-37.23) greater than the city population (41.8/100000 inhabitants). The system reorganization will have to make the centers adequate to deal with this problem. (C) 2008 Elsevier Inc. All rights reserved.
Resumo:
Background: Nutrition therapy (NT) is essential for the care of critically ill children. Inadequate feeding leads to malnutrition and may increase the patient`s risk of morbidity and mortality. The aim of this study was to describe the NT used in a tertiary pediatric intensive care unit (PICU). Methods: The authors evaluated NT administered to 90 consecutive patients who were hospitalized for 7 days in the PICU of Instituto da Crianca, Hospital das Clinicas, Universidade de Sao Paulo, Brazil. NT was established according to the protocol provided by the institution`s NT team. NT provided a balance of fluids and nutrients and was monitored with a weekly anthropometric nutrition assessment and an evaluation of complications. Results: NT was initiated, on average, within 72 hours of hospitalization. Most children (80%) received enteral nutrition (EN) therapy; of these, 35% were fed orally and the rest via nasogastric or postpyloric tube. There were gastrointestinal complications in patients (5%) who needed a postpyloric tube. Parenteral nutrition (PN) was used in only 10% of the cases, and the remaining 10% received mixed NT (EN + PN). The average calorie and protein intake was 82 kcal/kg and 2.7 g/kg per day. Arm circumference and triceps skinfold thickness decreased. Conclusions: The use of EN was prevalent in the tertiary PICU, and few clinical complications occurred. There was no statistically significant change in most anthropometric indicators evaluated during hospitalization, which suggests that NT probably helped patients maintain their nutrition status. (JPEN J Parenter Enteral Nutr. 2011;35:523-529)
Resumo:
Purpose: Chipping within veneering porcelain has resulted in high clinical failure rates for implant-supported zirconia (yttria-tetragonal zirconia polycrystals [Y-TZP]) bridges. This study evaluated the reliability and failure modes of mouth-motion step-stress fatigued implant-supported Y-TZP versus palladium-silver alloy (PdAg) three-unit bridges. Materials and Methods: Implant-abutment replicas were embedded in polymethylmethacrylate resin. Y-TZP and PdAg frameworks, of similar design (n = 21 each), were fabricated, veneered, cemented (n = 3 each), and Hertzian contact-tested to obtain ultimate failure load. In each framework group, 18 specimens were distributed across three step-stress profiles and mouth-motion cyclically loaded according to the profile on the lingual slope of the buccal cusp of the pontic. Results: PdAg failures included competing flexural cracking at abutment and/or connector area and chipping, whereas Y-TZP presented predominantly cohesive failure within veneering porcelain. Including all failure modes, the reliability (two-sided at 90% confidence intervals) for a ""mission"" of 50,000 and 100,000 cycles at 300 N load was determined (Alta Pro, Reliasoft, Tucson, AZ, USA). No difference in reliability was observed between groups for a mission of 50,000. Reliability remained unchanged for a mission of 100,000 for PdAg, but significantly decreased for Y-TZP. Conclusions: Higher reliability was found for PdAg for a mission of 100,000 cycles at 300 N. Failure modes differed between materials.
Resumo:
The complete sequence of the MCIR locus has been assembled, the coding region of the gene is intronless and placed within a 12 kb region flanked by the NULP1 and TUBB4 genes. The immediate promoter region has an E-box site with homology to the M-box consensus known to bind the microphthalmia transcription factor (MITF), however, promoter deletion analysis and transactivation studies have failed to show activation through this element by MITF. Polymorphism within the coding region, immediate 5' promoter region and a variable number tandem repeat (VNTR) minisatellite within the locus have been examined in a collection of Caucasian families and African individuals. Haplotype analysis shows linkage disequilibrium between the VNTR and MCIR coding region red hair variant alleles which can be used to estimate the age of these missense changes. Assuming a mean VNTR mutation rate of 1% and a star phylogeny, we estimate the Arg151Cys variant arose 7500 years before the present day, suggesting these variants may have arisen in the Caucasian population more recently than previously thought. (C) 2001 Published by Elsevier Science B.V.
Resumo:
A system has been developed for studying the biodegradation of natural and synthetic polymeric material. The system is based on standard methods developed by the European Committee for Standardisation (CEN TC 261) (ISO/DIS 14855) and the American Society of Testing Materials, 'ASTM. Standard Test Method for Determining Aerobic. Biodegradation of Plastic Materials under Controlled Composting Conditions' (ASTM D 5338-92). A new low-cost compost facility has been used which satisfies the requirements of these standards. The system has been automated for data collection and has been run under the conditions specified by the standards. In the system, cellulose, newspaper and two starch-based polymers were treated with compost in a series of 3dm(3) vessels at 52 degreesC and under conditions of optimum moisture and pH. The degradation was followed over time by measuring the amount of carbon released as carbon dioxide. (C) 2001 Society of Chemical Industry.