896 resultados para Clinical Trail Design
Resumo:
BACKGROUND Pretreatment tables for the prediction of pathologic stage have been published and validated for localized prostate cancer (PCa). No such tables are available for locally advanced (cT3a) PCa. OBJECTIVE To construct tables predicting pathologic outcome after radical prostatectomy (RP) for patients with cT3a PCa with the aim to help guide treatment decisions in clinical practice. DESIGN, SETTING, AND PARTICIPANTS This was a multicenter retrospective cohort study including 759 consecutive patients with cT3a PCa treated with RP between 1987 and 2010. INTERVENTION Retropubic RP and pelvic lymphadenectomy. OUTCOME MEASUREMENTS AND STATISTICAL ANALYSIS Patients were divided into pretreatment prostate-specific antigen (PSA) and biopsy Gleason score (GS) subgroups. These parameters were used to construct tables predicting pathologic outcome and the presence of positive lymph nodes (LNs) after RP for cT3a PCa using ordinal logistic regression. RESULTS AND LIMITATIONS In the model predicting pathologic outcome, the main effects of biopsy GS and pretreatment PSA were significant. A higher GS and/or higher PSA level was associated with a more unfavorable pathologic outcome. The validation procedure, using a repeated split-sample method, showed good predictive ability. Regression analysis also showed an increasing probability of positive LNs with increasing PSA levels and/or higher GS. Limitations of the study are the retrospective design and the long study period. CONCLUSIONS These novel tables predict pathologic stage after RP for patients with cT3a PCa based on pretreatment PSA level and biopsy GS. They can be used to guide decision making in men with locally advanced PCa. PATIENT SUMMARY Our study might provide physicians with a useful tool to predict pathologic stage in locally advanced prostate cancer that might help select patients who may need multimodal treatment.
Resumo:
OBJECTIVES Randomized clinical trials that enroll patients in critical or emergency care (acute care) setting are challenging because of narrow time windows for recruitment and the inability of many patients to provide informed consent. To assess the extent that recruitment challenges lead to randomized clinical trial discontinuation, we compared the discontinuation of acute care and nonacute care randomized clinical trials. DESIGN Retrospective cohort of 894 randomized clinical trials approved by six institutional review boards in Switzerland, Germany, and Canada between 2000 and 2003. SETTING Randomized clinical trials involving patients in an acute or nonacute care setting. SUBJECTS AND INTERVENTIONS We recorded trial characteristics, self-reported trial discontinuation, and self-reported reasons for discontinuation from protocols, corresponding publications, institutional review board files, and a survey of investigators. MEASUREMENTS AND MAIN RESULTS Of 894 randomized clinical trials, 64 (7%) were acute care randomized clinical trials (29 critical care and 35 emergency care). Compared with the 830 nonacute care randomized clinical trials, acute care randomized clinical trials were more frequently discontinued (28 of 64, 44% vs 221 of 830, 27%; p = 0.004). Slow recruitment was the most frequent reason for discontinuation, both in acute care (13 of 64, 20%) and in nonacute care randomized clinical trials (7 of 64, 11%). Logistic regression analyses suggested the acute care setting as an independent risk factor for randomized clinical trial discontinuation specifically as a result of slow recruitment (odds ratio, 4.00; 95% CI, 1.72-9.31) after adjusting for other established risk factors, including nonindustry sponsorship and small sample size. CONCLUSIONS Acute care randomized clinical trials are more vulnerable to premature discontinuation than nonacute care randomized clinical trials and have an approximately four-fold higher risk of discontinuation due to slow recruitment. These results highlight the need for strategies to reliably prevent and resolve slow patient recruitment in randomized clinical trials conducted in the critical and emergency care setting.
Resumo:
OBJECTIVES Improvement of skin fibrosis is part of the natural course of diffuse cutaneous systemic sclerosis (dcSSc). Recognising those patients most likely to improve could help tailoring clinical management and cohort enrichment for clinical trials. In this study, we aimed to identify predictors for improvement of skin fibrosis in patients with dcSSc. METHODS We performed a longitudinal analysis of the European Scleroderma Trials And Research (EUSTAR) registry including patients with dcSSc, fulfilling American College of Rheumatology criteria, baseline modified Rodnan skin score (mRSS) ≥7 and follow-up mRSS at 12±2 months. The primary outcome was skin improvement (decrease in mRSS of >5 points and ≥25%) at 1 year follow-up. A respective increase in mRSS was considered progression. Candidate predictors for skin improvement were selected by expert opinion and logistic regression with bootstrap validation was applied. RESULTS From the 919 patients included, 218 (24%) improved and 95 (10%) progressed. Eleven candidate predictors for skin improvement were analysed. The final model identified high baseline mRSS and absence of tendon friction rubs as independent predictors of skin improvement. The baseline mRSS was the strongest predictor of skin improvement, independent of disease duration. An upper threshold between 18 and 25 performed best in enriching for progressors over regressors. CONCLUSIONS Patients with advanced skin fibrosis at baseline and absence of tendon friction rubs are more likely to regress in the next year than patients with milder skin fibrosis. These evidence-based data can be implemented in clinical trial design to minimise the inclusion of patients who would regress under standard of care.
Resumo:
Objective. To evaluate the HEADS UP Virtual Molecular Biology Lab, a computer-based simulated laboratory designed to teach advanced high school biology students how to create a mouse model. ^ Design. A randomized clinical control design of forty-four students from two science magnet high schools in Mercedes, Texas was utilized to assess knowledge and skills of molecular laboratory procedures, attitudes towards science and computers as a learning tool, and usability of the program. ^ Measurements. Data was collected using five paper-and-pencil formatted questionnaires and an internal "lab notebook." ^ Results. The Virtual Lab was found to significantly increase student knowledge over time (p<0.005) and with each use (p<0.001) as well as positively increase attitudes towards computers (p<0.001) and skills (p<0.005). No significant differences were seen in science attitude scores.^ Conclusion. These results provide evidence that the HEADS UP Virtual Molecular Biology Lab is a potentially effective educational tool for high school molecular biology education.^
Resumo:
Purpose: To determine the effect of coloured light filter overlays on reading rates for people with age-related macular degeneration (AMD). Method: Using a prospective clinical trial design, we examined the null hypothesis that coloured light filter overlays do not improve reading rates in AMD when compared to a clear filter. Reading rates for 12 subjects with non-exudative AMD, associated with a relative scotoma and central fixation (mean age 81 years, SD 5.07 years) were determined using the Rate of Reading Test® (printed, nonsense, lower case sans serif, stationary text) with 10 different, coloured light filter overlays (Intuitive Overlays®; figures in brackets are percentage transmission values); rose (78%), pink (78%), purple (67%), aqua (81%), blue (74%), lime-green (86%), mint-green (85%), yellow (93%), orange (83%) and grey (71%). A clear overlay (Roscolene # 00) (360 cdm-2) with 100% transmittance was used as a control. Results: ANOVA indicated that there was no statistically significant difference in reading rates with the coloured light filter overlays compared to the clear filter. Furthermore, chi-squared analysis indicated that the rose, purple and blue filters had a significantly poorer overall ranking in terms of reading rates compared to the other coloured and clear light filters. Conclusion: Coloured light filter overlays are unlikely to provide a clinically significant improvement in reading rates for people with non-exudative AMD associated with a relative scotoma and central fixation. Copyright © Acta Ophthalmol Scand 2004.
Resumo:
Background and Purpose - Stroke has global importance and it causes an increasing amount of human suffering and economic burden, but its management is far from optimal. The unsuccessful outcome of several research programs highlights the need for reliable data on which to plan future clinical trials. The Virtual International Stroke Trials Archive aims to aid the planning of clinical trials by collating and providing access to a rich resource of patient data to perform exploratory analyses. Methods - Data were contributed by the principal investigators of numerous trials from the past 16 years. These data have been centrally collated and are available for anonymized analysis and hypothesis testing. Results - ”Currently, the Virtual International Stroke Trials Archive contains 21 trials. There are data on 15 000 patients with both ischemic and hemorrhagic stroke. Ages range between 18 and 103 years, with a mean age of 6912 years. Outcome measures include the Barthel Index, Scandinavian Stroke Scale, National Institutes of Health Stroke Scale, Orgogozo Scale, and modified Rankin Scale. Medical history and onset-to-treatment time are readily available, and computed tomography lesion data are available for selected trials. Conclusions - This resource has the potential to influence clinical trial design and implementation through data analyses that inform planning. (Stroke. 2007;38:1905-1910.)
Resumo:
OBJECTIVE: To identify whether the use of a notch filter significantly affects the morphology or characteristics of the newborn auditory brainstem response (ABR) waveform and so inform future guidance for clinical practice. DESIGN: Waveforms with and without the application of a notch filter were recorded from babies undergoing routine ABR tests at 4000, 1000 and 500 Hz. Any change in response morphology was judged subjectively. Response latency, amplitude, and measurements of response quality and residual noise were noted. An ABR simulator was also used to assess the effect of notch filtering in conditions of low and high mains interference. RESULTS: The use of a notch filter changed waveform morphology for 500 Hz stimuli only in 15% of tests in newborns. Residual noise was lower when 4000 Hz stimuli were used. Response latency, amplitude, and quality were unaffected regardless of stimulus frequency. Tests with the ABR stimulator suggest that these findings can be extended to conditions of high level mains interference. CONCLUSIONS: A notch filter should be avoided when testing at 500 Hz, but at higher frequencies appears to carry no penalty.
Resumo:
Background: Despite significant advancements in psychopharmacology, treating major depressive disorder (MDD) is still a challenge considering the efficacy, tolerability, safety, and economical costs of most antidepressant drugs. One approach that has been increasingly investigated is modulation of cortical activity with tools of non-invasive brain stimulation - such as transcranial magnetic stimulation and transcranial direct current stimulation (tDCS). Due to its profile, tDCS seems to be a safe and affordable approach. Methods and design: The SELECT TDCS trial aims to compare sertraline vs. tDCS in a double-blinded, randomized, factorial trial enrolling 120 participants to be allocated to four groups to receive sertraline + tDCS, sertraline, tDCS or placebo. Eligibility criteria are moderate-to-severe unipolar depression (Hamilton Depression Rating Scale >17) not currently on sertraline treatment. Treatment will last 6 weeks and the primary outcome is depression change in the Montgomery-Asberg Depression Rating Score (MADRS). Potential biological markers that mediate response, such as BDNF serum levels, Val66Met BDNF polymorphism, and heart rate variability will also be examined. A neuropsychological battery with a focus on executive functioning will be administered. Discussion: With this design we will be able to investigate whether tDCS is more effective than placebo in a sample of patients free of antidepressants and in addition, we will be able to secondarily compare the effect sizes of sertraline vs. tDCS and also the comparison between tDCS and combination of tDCS and sertraline. (C) 2010 Elsevier Inc. All rights reserved.
Resumo:
Background The protease-activated receptor 1 (PAR-1), the main platelet receptor for thrombin, represents a novel target for treatment of arterial thrombosis, and SCH 530348 is an orally active, selective, competitive PAR-1 antagonist. We designed TRA.CER to evaluate the efficacy and safety of SCH 530348 compared with placebo in addition to standard of care in patients with non-ST-segment elevation (NSTE) acute coronary syndromes (ACS) and high-risk features. Trial design TRA.CER is a prospective, randomized, double-blind, multicenter, phase III trial with an original estimated sample size of 10,000 subjects. Our primary objective is to demonstrate that SCH 530348 in addition to standard of care will reduce the incidence of the composite of cardiovascular death, myocardial infarction (MI), stroke, recurrent ischemia with rehospitalization, and urgent coronary revascularization compared with standard of care alone. Our key secondary objective is to determine whether SCH 530348 will reduce the composite of cardiovascular death, MI, or stroke compared with standard of care alone. Secondary objectives related to safety are the composite of moderate and severe GUSTO bleeding and clinically significant TIMI bleeding. The trial will continue until a predetermined minimum number of centrally adjudicated primary and key secondary end point events have occurred and all subjects have participated in the study for at least I year. The TRA.CER trial is part of the large phase III SCH 530348 development program that includes a concomitant evaluation in secondary prevention. Conclusion TRA.CER will define efficacy and safety of the novel platelet PAR-1 inhibitor SCH 530348 in the treatment of high-risk patients with NSTE ACS in the setting of current treatment strategies. (Am Heart J 2009; 158:327-34.)
Resumo:
1. There are a variety of methods that could be used to increase the efficiency of the design of experiments. However, it is only recently that such methods have been considered in the design of clinical pharmacology trials. 2. Two such methods, termed data-dependent (e.g. simulation) and data-independent (e.g. analytical evaluation of the information in a particular design), are becoming increasingly used as efficient methods for designing clinical trials. These two design methods have tended to be viewed as competitive, although a complementary role in design is proposed here. 3. The impetus for the use of these two methods has been the need for a more fully integrated approach to the drug development process that specifically allows for sequential development (i.e. where the results of early phase studies influence later-phase studies). 4. The present article briefly presents the background and theory that underpins both the data-dependent and -independent methods with the use of illustrative examples from the literature. In addition, the potential advantages and disadvantages of each method are discussed.
Resumo:
In this work, a new method of optimization is successfully applied to the theoretical design of compact, actively shielded, clinical MRI magnets. The problem is formulated as a two-step process in which the desired current densities on multiple, cc-axial surface layers are first calculated by solving Fredholm equations of the first kind. Non-linear optimization methods with inequality constraints are then invoked to fit practical magnet coils to the desired current densities. The current density approach allows rapid prototyping of unusual magnet designs. The emphasis of this work is on the optimal design of short, actively-shielded MRI magnets for whole-body imaging. Details of the hybrid numerical model are presented, and the model is used to investigate compact, symmetric, and asymmetric MRI magnets. Magnet designs are presented for actively-shielded, symmetric magnets of coil length 1.0 m, which is considerably shorter than currently available designs of comparable dsv size. Novel, actively-shielded, asymmetric magnet designs are also presented in which the beginning of a 50-cm dsv is positioned just 11 cm from the end of the coil structure, allowing much improved access to the patient and reduced patient claustrophobia. Magn Reson Med 45:331540, 2001. (C) 2001 Wiley-Liss, Inc.
Resumo:
Novel current density mapping (CDM) schemes are developed for the design of new actively shielded, clinical magnetic resonance imaging (MRI) magnets. This is an extended inverse method in which the entire potential solution space for the superconductors has been considered, rather than single current density layers. The solution provides an insight into the required superconducting coil pattern for a desired magnet configuration. This information is then used as an initial set of parameters for the magnet structure, and a previously developed hybrid numerical optimization technique is used to obtain the final geometry of the magnet. The CDM scheme is applied to the design of compact symmetric, asymmetric, and open architecture 1.0-1.5 T MRI magnet systems of novel geometry and utility. A new symmetric 1.0-T system that is just I m in length with a full 50-cm diameter of the active, or sensitive, volume (DSV) is detailed, as well as an asymmetric system in which a 50-cm DSV begins just 14 cm from the end of the coil structure. Finally a 1.0-T open magnet system with a full 50-cm DSV is presented. These new designs provide clinically useful homogeneous regions and have appropriately restricted stray fields but, in some of the designs, the DSV is much closer to the end of the magnet system than in conventional designs. These new designs have the potential to reduce patient claustrophobia and improve physician access to patients undergoing scans. (C) 2002 Wiley Periodicals, Inc.