937 resultados para Ciclismo indoor


Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper presents a preliminary acoustic study concerning the development of the first prototype of a patented removable module for interior partitioning. It is a prefabricated, vertical element for division of interior spaces that does not require the use of gutters or technical support. A set of such modules, linearly disposed, will create a division, allowing the personalization of any indoor area, including open office spaces, rooms, among others. The main characteristic that distinguishes this element from the existing solutions available on the market is that its mobility relies exclusively on a set of integrated bearings at the base of each module. Through an incorporated elevation system, the user can lower the module, move it to the desired position and re-elevate it until pressed against the ledge of the ceiling, making it stable. In this sense, and taking into account its acoustic behavior, several tests were made in the LNEC acoustics lab. Airborne sound insulation tests for different typologies of the prototype were conducted, according to the applicable standards EN ISO 354:2003, EN ISO 717-1:2013 and EN ISO 10140-2:2010. Some important conclusions and analysis of the prototype viability were extracted.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This project proposes an approach for supporting Indoor Navigation Systems using Pedestrian Dead Reckoning-based methods and by analyzing motion sensor data available in most modern smartphones. Processes suggested in this investigation are able to calculate the distance traveled by a user while he or she is walking. WLAN fingerprint- based navigation systems benefit from the processes followed in this research and results achieved to reduce its workload and improve its positioning estimations.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This project attempts to provide an in-depth competitive assessment of the Portuguese indoor location-based analytics market, and to elaborate an entry-pricing strategy for Business Intelligence Positioning System (BIPS) implementation in Portuguese shopping centre stores. The role of industry forces and company’s organizational resources platform to sustain company’s competitive advantage was explored. A customer value-based pricing approach was adopted to assess BIPS value to retailers and maximize Sonae Sierra profitability. The exploratory quantitative research found that there is a market opportunity to explore every store area types with tailored proposals, and to set higher-than-tested membership fees to allow a rapid ROI, concluding there are propitious conditions for Sierra to succeed in BIPS store’s business model in Portugal.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Solar passive strategies that have been developed in vernacular architecture from different regions are a response to specific climate effects. These strategies are usually simple, low-tech and have low potential environmental impact. For this reason, several studies highlight them as having potential to reduce the demands of non-renewable energy for buildings operation. In this paper, the climatic contrast between northern and southern parts of mainland Portugal is presented, namely the regions of Beira Alta and Alentejo. Additionally, it discusses the contribution of different climate-responsive strategies developed in vernacular architecture from both regions to assure thermal comfort conditions. In Beira Alta, the use of glazed balconies as a strategy to capture solar gains is usual, while in Alentejo the focus is on passive cooling strategies. To understand the effectiveness of these strategies, thermal performances and comfort conditions of two case studies were evaluated based on the adaptive comfort model. Field tests included measurement of hygrothermal parameters and surveys on occupants’ thermal sensation. From the results, it has been found that the case studies have shown a good thermal performance by passive means alone and that the occupants feel comfortable, except during winter where there is the need to use simple heating systems.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dissertação de mestrado em Human Engineering

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJETIVO: Determinar os efeitos do estado e especificidade de treinamento aeróbio na relação entre o percentual do consumo máximo de oxigênio (%VO2max) e o percentual da frequência cardíaca máxima (%FCmax) durante o exercício incremental realizado no cicloergômetro. MÉTODOS: Sete corredores, 9 ciclistas, 11 triatletas e 12 sedentários, todos do sexo masculino e aparentemente saudáveis, foram submetidos a um teste incremental até a exaustão no cicloergômetro. Regressões lineares entre %VO2max e %FCmax foram determinadas para cada indivíduo. Com base nessas regressões, foram calculados %FCmax correspondentes a determinados %VO2max (50, 60, 70, 80 e 90%) de cada participante. RESULTADOS: Não foram encontradas diferenças significantes entre todos os grupos nos %FCmax para cada um dos %VO2max avaliados. Analisando-se os voluntários como um único grupo, as médias dos %FCmax correspondentes a 50, 60, 70, 80 e 90% %VO2max foram 67, 73, 80, 87, e 93%, respectivamente. CONCLUSÃO: Nos grupos analisados, a relação entre o %VO2max e %FCmax durante o exercício incremental no ciclismo não é dependente do estado e especificidade do treinamento aeróbio.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Magdeburg, Univ., Fak. für Elektrotechnik und Informationstechnik, Diss., 2010

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Magdeburg, Univ., Fak. für Elektrotechnik und Informationstechnik, Diss., 2015

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Es tracta d'un projecte evolutiu que permetrà crear una aplicació que serveixi de suport gràfic per a les classes de Ciclo Indoor i que a més a més permetrà al professor preparar-les en pocs minuts. També tindrà un apartat dedicat a gestionar als usuaris del sistema mitjançant una connexió a una base de dades que també ha sigut dissenyada i desenvolupada en aquest projecte.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this study it was compared the MAS-100 and the Andersen air samplers' performances and a similar trend in both instruments was observed. It was also evaluated the microbial contamination levels in 3060 samples of offices, hospitals, industries, and shopping centers, in the period of 1998 to 2002, in Rio de Janeiro city. Considering each environment, 94.3 to 99.4% of the samples were the allowed limit in Brazil (750 CFU/m³). The industries' results showed more important similarity among fungi and total heterotrophs distributions, with the majority of the results between zero and 100 CFU/m³. The offices' results showed dispersion around 300 CFU/m³. The hospitals' results presented the same trend, with an average of 200 CFU/m³. Shopping centers' environments showed an average of 300 CFU/m³ for fungi, but presented a larger dispersion pattern for the total heterotrophs, with the highest average (1000 CFU/m³). It was also investigated the correlation of the sampling period with the number of airborne microorganisms and with the environmental parameters (temperature and air humidity) through the principal components analysis. All indoor air samples distributions were very similar. The temperature and air humidity had no significant influence on the samples dispersion patterns.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction: Exposure to environmental tobacco smoke (ETS) is a major environmental risk factor. Indoor contaminants come from a variety of sources, which can include inadequate ventilation, volatile organic compounds (VOCs), biological agents, combustion products, and ETS. Because ETS is one of the most frequent causes of IAQ complaints as well as the high mortality of passive smoking, in June 2004 the University of Geneva made the decision to ban smoking inside the so called "Uni-Mail" building, the biggest Swiss University human science building of recent construction, and the ordinance was applied beginning in October 2004. This report presents the finding related to the IAQ of the "Uni-Mail" building before and after smoking bans using nicotine, suspended dust, condensate and PAHs level in air as tracers to perform an assessment of passive tobacco exposure for non-smokers inside the building. Methods: Respirable particles (RSP) A real time aerosol monitor (model DataRAM)was place at sampling post 1, level ground floor. Condensate It consists in extracting any organic matter taken on the glass fibre filters by MeOH, and then measuring the total absorbent of the MeOH extract to the UV wavelength of 447 nm. Nicotine Nicotine was taken by means of cartridges containing of XAD-4 to the fixed flow of 0.5 L/min. The analytical method used for the determination of nicotine is based on gas chromatography with Nitrogen selective detector GC-NPD. Results: Figure 1 shows the box plot density display of 3 parameters before and after smoking bans for all 7 sampling posts: dust, condensate and nicotine in air in μg/m3. Conclusion: Before the smoking ban, the level of the concentrations of respirable particles (RSP) is raised more, average of the day 320 μg/m3, with peaks of more than 1000 μg/m3, compared with the values of the surrounding air between 22 and 30 μg/m3. The nicotine level is definitely more important (average 5.53 μg/m3, field 1.5 to 17.9 μg/m3). Once the smoking bans inside the building were applied, one notes a clear improvement in terms of concentrations of pollutants. For dust, the concentration fell by 3 times (average: 130 μg/m3, range: 40 to 160 μg/m3) and that of nicotine by 10 times (average: 0.53 μg/m3, range: 0 to 1.69 μg/m3) compared to that found before smoking bans. The outdoor air RSP concentration was 22 μg/m3 or 10 times lower. Nicotine seems to be the best tracer for ETS free of interference, independent of location or season.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: In Switzerland, nationwide large-scale radon surveys have been conducted since the early 1980s to establish the distribution of indoor radon concentrations (IRC). The aim of this work was to study the factors influencing IRC in Switzerland using univariate analyses that take into account biases caused by spatial irregularities of sampling. METHODS: About 212,000 IRC measurements carried out in more than 136,000 dwellings were available for this study. A probability map to assess risk of exceeding an IRC of 300 Bq/m(3) was produced using basic geostatistical techniques. Univariate analyses of IRC for different variables, namely the type of radon detector, various building characteristics such as foundation type, year of construction and building type, as well as the altitude, the average outdoor temperature during measurement and the lithology, were performed comparing 95% confidence intervals among classes of each variable. Furthermore, a map showing the spatial aggregation of the number of measurements was generated for each class of variable in order to assess biases due to spatially irregular sampling. RESULTS: IRC measurements carried out with electret detectors were 35% higher than measurements performed with track detectors. Regarding building characteristics, the IRC of apartments are significantly lower than individual houses. Furthermore, buildings with concrete foundations have the lowest IRC. A significant decrease in IRC was found in buildings constructed after 1900 and again after 1970. Moreover, IRC decreases at higher outdoor temperatures. There is also a tendency to have higher IRC with altitude. Regarding lithology, carbonate rock in the Jura Mountains produces significantly higher IRC, almost by a factor of 2, than carbonate rock in the Alps. Sedimentary rock and sediment produce the lowest IRC while carbonate rock from the Jura Mountains and igneous rock produce the highest IRC. Potential biases due to spatially unbalanced sampling of measurements were identified for several influencing factors. CONCLUSIONS: Significant associations were found between IRC and all variables under study. However, we showed that the spatial distribution of samples strongly affected the relevance of those associations. Therefore, future methods to estimate local radon hazards should take the multidimensionality of the process of IRC into account.