997 resultados para Chord normal force


Relevância:

30.00% 30.00%

Publicador:

Resumo:

Normal coordinate analysis of a molecule of the type XY7 (point group D5h) has been carried out using Wilson's FG, matrix method and the results have been utilized to calculate the force constants of IF7 from the available Raman and infrared data. Some of the assignments made previously by Lord and others have been revised and with the revised assignments the thermodynamic quantities of IF7 have been computed from 300°K to 1000°K under rigid rotator and harmonic oscillator approximation.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Infrared and Raman spectra of N,N-dimethylacetamide (DMA) are recorded and the normal vibrational analysis of the DMA skeleton as well as the entire molecule carried out employing the Urey-Bradley and modified Urey-Bradley force fields. Vibrational frequencies are assigned on the basis of the normal coordinate calculations and are compared with those of related molecules. Infrared spectra of metal complexes are examined to substantiate the band assignments.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Infrared and Raman spectra of N,N-dimethylacetamide (DMA) are recorded and the normal vibrational analysis of the DMA skeleton as well as the entire molecule carried out employing the Urey-Bradley and modified Urey-Bradley force fields. Vibrational frequencies are assigned on the basis of the normal coordinate calculations and are compared with those of related molecules. Infrared spectra of metal complexes are examined to substantiate the band assignments.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The i.r. spectra of selenoacetamide and its N-deuterated species have been recorded The fundamental frequencies of these compounds have been assigned. Force constants derived for thioacetamide and acetamide were transferred to the present compound and a good agreement with the observed frequencies were achieved. The results are discussed in relation to acetamide and thioacetamide.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A single component accelerometer-based force balance is developed, calibrated, and used for high enthalpy applications. Functionality of this force balance, for such applications, is demonstrated for the first time during high enthalpy tests in a newly established free piston-driven shock tunnel, HST3, using a 60 degrees apex angle blunt cone model at 0 degrees angle of incidence. Usefulness of this force balance is also confirmed, for much complicated high enthalpy flow situations, during the drag reduction studies with counterflow supersonic jet from the stagnation point.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The infrared spectra of N-methylthiourea (NMTU) and its N-deuterated and S-methylated species were measured. Assignment of the infrared and Raman spectra of NMTU has been accomplished by correlation with thiourea and by use of infrared band shifts on N-deuteration as well as S-methylation. Normal coordinate analysis was performed for all the fundamentals of NMTU and NMTU-d3, the assignments obtained from the force field calculations being discussed in relation to those in other related thioureas and thioamides. The potential barriers to the internal rotations for the �NH2, �CH3, and �CN groups were estimated from the force constants.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

New composition gradient solid electrolytes have been designed for application in high temperature solid-state galvanic sensors and in thermodynamic measurements. The functionally gradient electrolyte consists of a solid solution between two or more ionic conductors with a common ion and gradual variation in composition of the other ionic species. Unequal rates of migration of the ions, caused by the presence of the concentration gradient, may result in the development of space charge, manifesting as diffusion potential. Presented is a theoretical analysis of the EMF of cells incorporating gradient solid electrolytes. An analytical expression is derived for diffusion potential, using the thermodynamics of irreversible processes, for different types of concentration gradients and boundary conditions at the electrode/electrolyte interfaces. The diffusion potential of an isothermal cell incorporating these gradient electrolytes becomes negligible if there is only one mobile ion and the transport numbers of the relatively immobile polyionic species and electrons approach zero. The analysis of the EMF of a nonisothermal cell incorporating a composition gradient solid electrolyte indicates that the cell EMF can be expressed in terms of the thermodynamic parameters at the electrodes and the Seebeck coefficient of the gradient electrolyte under standard conditions when the transport number of one of the ions approaches unity.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The drag and lift coefficients for a viscous optimized Mach 6 conical waverider has been measured using an accelerometer force balance system in the IISc hypersonic shock tunnel. A rubber bush placed in between the waverider model and the steel sting ensures unrestrained motion to the model during shock tunnel testing (500 mu s). Two accelerometers mounted on the model are used to measure the model accelerations in the axial and normal directions. The measured value of lift to drag ratio at zero angle of incidence for the IISc conical waverider with viscous optimized leading edge is 2.149, which compares well with the value reported in the open literature (Anderson et al 1991) for similar class of waveriders designed for a flight Mach number of 6. The details of the experimental study along with illustrative numerical results are discussed in this paper.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper presents the design and implementation of a reorientable scanning probe that is capable of two-axis force sensing and control in the 2-D scanning (X-Z) plane. The probe is comprised of three major components, namely a compliant manipulator, laser measurement system, and magnetic actuation system. Control of the position and orientation of the probe tip is realized by means of magnetic actuation combined with a novel structural design. The design of the manipulator's compliance and that of the optical path of the laser measurement system together enable achieving sensitivity to lateral (X) forces that is nearly identical to that of normal (Z) forces. The achieved sensitivity ratio, of about 0.6, is significantly higher than that of conventional scanning probe systems. The theoretical bases for the structural design and the sensitivity of the two-axis force sensing system are presented. Subsequently, fabrication of the manipulator is described and the result of experimental evaluation of the scanning probe's features is discussed. The scanning probe is used to access the vertical and re-entrant features on the two sides of a cylindrical micropipette, which are subsequently scanned by regulating the lateral force of tip-sample interaction.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

It has been shown earlier1] that the relaxed force constants (RFCs) could be used as a measure of bond strength only when the bonds form a part of the complete valence internal coordinates (VIC) basis. However, if the bond is not a part of the complete VIC basis, its RFC is not necessarily a measure of bond strength. Sometimes, it is possible to have a complete VIC basis that does not contain the intramolecular hydrogen bond (IMHB) as part of the basis. This means the RFC of IMHB is not necessarily a measure of bond strength. However, we know that IMHB is a weak bond and hence its RFC has to be a measure of bond strength. We resolve this problem of IMHB not being part of the complete basis by postulating `equivalent' basis sets where IMHB is part of the basis at least in one of the equivalent sets of VIC. As long as a given IMHB appears in one of the equivalent complete VIC basis sets, its RFC could be used as a measure of bond strength parameter.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Direct measurement of three-dimensional (3-D) forces between an atomic force microscope (AFM) probe and the sample benefits diverse applications of AFM, including force spectroscopy, nanometrology, and manipulation. This paper presents the design and evaluation of a measurement system, wherein the deflection of the AFM probe is obtained at two points to enable direct measurement of all the three components of 3-D tip-sample forces in real time. The optimal locations for measurement of deflection on the probe are derived for a conventional AFM probe. Further, a new optimal geometry is proposed for the probe that enables measurement of 3-D forces with identical sensitivity and nearly identical resolution along all three axes. Subsequently, the designed measurement system and the optimized AFM probe are both fabricated and evaluated. The evaluation demonstrates accurate measurement of tip-sample forces with minimal cross-sensitivities. Finally, the real-time measurement system is employed as part of a feedback control system to regulate the normal component of the interaction force, and to perform force-controlled scribing of a groove on the surface of polymethyl methacrylate.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A modified tapping mode of the atomic force microscope (AFM) was introduced for manipulation, dissection, and lithography. By sufficiently decreasing the amplitude of AFM tip in the normal tapping mode and adjusting the setpoint, the tip-sample interaction can be efficiently controlled. This modified tapping mode has some characteristics of the AFM contact mode and can be used to manipulate nanoparticles, dissect biomolecules, and make lithographs on various surfaces. This method did not need any additional equipment and it can be applied to any AFM system.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Air Force Office of Scientific Research (F49620-01-1-0397); Office of Naval Research (N00014-01-1-0624)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The processes by which humans and other primates learn to recognize objects have been the subject of many models. Processes such as learning, categorization, attention, memory search, expectation, and novelty detection work together at different stages to realize object recognition. In this article, Gail Carpenter and Stephen Grossberg describe one such model class (Adaptive Resonance Theory, ART) and discuss how its structure and function might relate to known neurological learning and memory processes, such as how inferotemporal cortex can recognize both specialized and abstract information, and how medial temporal amnesia may be caused by lesions in the hippocampal formation. The model also suggests how hippocampal and inferotemporal processing may be linked during recognition learning.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Our long-term goal is the detection and characterization of vulnerable plaque in the coronary arteries of the heart using intravascular ultrasound (IVUS) catheters. Vulnerable plaque, characterized by a thin fibrous cap and a soft, lipid-rich necrotic core is a precursor to heart attack and stroke. Early detection of such plaques may potentially alter the course of treatment of the patient to prevent ischemic events. We have previously described the characterization of carotid plaques using external linear arrays operating at 9 MHz. In addition, we previously modified circular array IVUS catheters by short-circuiting several neighboring elements to produce fixed beamwidths for intravascular hyperthermia applications. In this paper, we modified Volcano Visions 8.2 French, 9 MHz catheters and Volcano Platinum 3.5 French, 20 MHz catheters by short-circuiting portions of the array for acoustic radiation force impulse imaging (ARFI) applications. The catheters had an effective transmit aperture size of 2 mm and 1.5 mm, respectively. The catheters were connected to a Verasonics scanner and driven with pushing pulses of 180 V p-p to acquire ARFI data from a soft gel phantom with a Young's modulus of 2.9 kPa. The dynamic response of the tissue-mimicking material demonstrates a typical ARFI motion of 1 to 2 microns as the gel phantom displaces away and recovers back to its normal position. The hardware modifications applied to our IVUS catheters mimic potential beamforming modifications that could be implemented on IVUS scanners. Our results demonstrate that the generation of radiation force from IVUS catheters and the development of intravascular ARFI may be feasible.