990 resultados para Catheterization, Central venous
Resumo:
BACKGROUND Transcatheter aortic valve-in-valve implantation is an emerging therapeutic alternative for patients with a failed surgical bioprosthesis and may obviate the need for reoperation. We evaluated the clinical results of this technique using a large, worldwide registry. METHODS AND RESULTS The Global Valve-in-Valve Registry included 202 patients with degenerated bioprosthetic valves (aged 77.7±10.4 years; 52.5% men) from 38 cardiac centers. Bioprosthesis mode of failure was stenosis (n=85; 42%), regurgitation (n=68; 34%), or combined stenosis and regurgitation (n=49; 24%). Implanted devices included CoreValve (n=124) and Edwards SAPIEN (n=78). Procedural success was achieved in 93.1% of cases. Adverse procedural outcomes included initial device malposition in 15.3% of cases and ostial coronary obstruction in 3.5%. After the procedure, valve maximum/mean gradients were 28.4±14.1/15.9±8.6 mm Hg, and 95% of patients had ≤+1 degree of aortic regurgitation. At 30-day follow-up, all-cause mortality was 8.4%, and 84.1% of patients were at New York Heart Association functional class I/II. One-year follow-up was obtained in 87 patients, with 85.8% survival of treated patients. CONCLUSIONS The valve-in-valve procedure is clinically effective in the vast majority of patients with degenerated bioprosthetic valves. Safety and efficacy concerns include device malposition, ostial coronary obstruction, and high gradients after the procedure.
Resumo:
The aim of this report is to address the benefits of the minimal invasive venous drainage in a pediatric cardio surgical scenario. Juvenile bovine experiments (67.4+/-11 kg) were performed. The right atrium was cannulated in a trans-jugular way by using the self-expandable (Smart Stat, 12/20F, 430 mm) venous cannula (Smartcannula LLC, Lausanne, Switzerland) vs. a 14F 250 mm (Polystan Lighthouse) standard pediatric venous cannula. Establishing the cardiopulmonary bypass (CPB), the blood flows were assessed for 20 mmHg, 30 mmHg and 40 mmHg of driving pressure. Venous drainage (flow in l/min) at 20 mmHg, 30 mmHg, and 40 mmHg drainage load was 0.26+/-0.1, 0.35+/-0.2 and 0.28+/-0.08 for the 14F standard vs. 1.31+/-0.22, 1.35+/-0.24 and 1.9+/-0.2 for the Smart Stat 12/20F cannula. The 43 cm self-expanding 12/20F Smartcannula outperforms the 14F standard cannula. The results described herein allow us to conclude that usage of the self-expanding Smartcannula also in the pediatric patients improves the flow and the drainage capacity, avoiding the insufficient and excessive drainage. We believe that similar results may be expected in the clinical settings.
Resumo:
PURPOSE: Totally implanted vascular (TIVA) ports are used in children for repeated blood samples or intravenous treatments. We have recently published a prospective evaluation of surgical incidents and early complications associated with these devices. This work is the final part of the same study, assessing late complications over a follow-up of 2 yrs. METHODS: From January 2006 to January 2008, children older than 1 yr of age with a diagnosis of solid or blood cell malignancy were included. Insertion technique and care of the device were standardized. Every manipulation was prospectively recorded by specialized nurses. Obstruction was documented clinically. When bacteremia was suspected, routine central and peripheral blood cultures were drawn. RESULTS: Forty-five consecutive patients were enrolled in the study. Mean age at the time of the procedure was 8.5 yrs. There was no catheter-related infection within the first 4 weeks post-surgery. No device had to be removed because of infection or obstruction during follow-up. Frequent accesses to the port (=3 per day over a 10-day period) were associated with an 8-fold risk of infection. CONCLUSION: Insertion and use of TIVA devices were frequently associated with complications. No device had to be removed because of infection or obstruction over the follow-up period, although no prophylactic antibiotic agent was used. Restrictive use of antibiotics may prevent opportunistic infection. Frequent access to the device was significantly associated with line infection (odds ratio=8.43). No risk factor was identified for obstruction which occurred at a rate of 5.3 per 10,000 accesses.
Resumo:
PURPOSE: A misleading blood tacrolimus concentration (BTC) value caused by the contamination of a central venous catheter previously used for tacrolimus administration is described. SUMMARY: A 59-year-old woman with severe chronic obstructive pulmonary disease successfully underwent double lung transplantation. In the intensive care unit, she received a continuous i.v. infusion of tacrolimus from days 1 to 5 after transplantation through the distal lumen of a polyurethane triple-lumen central venous catheter. The catheter lumen was flushed twice a day with 0.9% sodium chloride injection. The proximal lumen was used for blood sampling after being flushed; the first 10 mL of blood was discarded. BTCs determined in whole blood one, four, and five days after transplantation were within the therapeutic range of 5-15 ng/mL. On day five the patient was transferred to the thoracic surgery ward and was switched to oral tacrolimus 1.5 mg twice daily. The BTC on day 6 was unexpectedly high at 134.5 ng/mL. The patient's clinical status was normal, and no signs of tacrolimus toxicity were observed. On day 7, blood samples were drawn from a peripheral vein and simultaneously through the central venous catheter. Although the central venous catheter had not been exposed to tacrolimus during the preceding two days, it yielded blood with a BTC eight times higher than the BTC in blood from the peripheral vein (41.4 ng/mL versus 5.1 ng/mL). CONCLUSION: The collection of blood from a central venous catheter lumen that had been used for tacrolimus administration resulted in a BTC about eight times higher than what was measured in peripheral blood.
Resumo:
The year 2014 was rich in significant advances in all areas of internal medicine. Many of them have an impact on our daily practice and on the way we manage one problem or another. From the use of the ultrasound for the diagnosis of pneumonia to the choice of the site of venous access and the type of line, and the increasing complexity of choosing an oral anticoagulant agent, this selection offers to the readers a brief overview of the major advances. The chief residents in the Service of internal medicine of the Lausanne University hospital are pleased to share their readings.
Resumo:
OBJECTIVE: To report the hemodynamic and functional responses obtained with clinical optimization guided by hemodynamic parameters in patients with severe and refractory heart failure. METHODS: Invasive hemodynamic monitoring using right heart catheterization aimed to reach low filling pressures and peripheral resistance. Frequent adjustments of intravenous diuretics and vasodilators were performed according to the hemodynamic measurements. RESULTS: We assessed 19 patients (age = 48±12 years and ejection fraction = 21±5%) with severe heart failure. The intravenous use of diuretics and vasodilators reduced by 12 mm Hg (relative reduction of 43%) pulmonary artery occlusion pressure (P<0.001), with a concomitant increment of 6 mL per beat in stroke volume (relative increment of 24%, P<0.001). We observed significant associations between pulmonary artery occlusion pressure and mean pulmonary artery pressure (r=0.76; P<0.001) and central venous pressure (r=0.63; P<0.001). After clinical optimization, improvement in functional class occurred (P< 0.001), with a tendency towards improvement in ejection fraction and no impairment to renal function. CONCLUSION: Optimization guided by hemodynamic parameters in patients with refractory heart failure provides a significant improvement in the hemodynamic profile with concomitant improvement in functional class. This study emphasizes that adjustments in blood volume result in imme-diate benefits for patients with severe heart failure.
Resumo:
A method for hemodialysis catheter placement in patients with central thoracic venous stenosis or occlusion is described and initial results are analyzed. Twelve patients, with a mean age of 63.2 years (42-80 years), with central venous stenosis or occlusion, and who required a hemodialysis catheter were reviewed. All lesions were confirmed by helical CT or phlebography. Five patients had stenosis while seven patients were diagnosed with an occlusion of thoracic central veins. All patients were asymptomatic, without sign of superior vena cava syndrome. After percutaneous transstenotic catheterization or guidewire-based recannalization in occlusions, a balloon dilatation was performed and a stent was placed, when necessary, prior to catheter placement. Technical success was 92%. Three patients had angioplasty alone and nine patients had angioplasty with stent placement. Dialysis catheters were successfully inserted through all recannalized accesses. No immediate complication occurred, nor did any patient develop superior vena cava syndrome after the procedure. The mean follow-up was 21.8 months (range, 8-48 months). Three patients developed a catheter dysfunction with fibrin sheath formation (at 7, 11, and 12 months after catheter placement, respectively). Two were successfully managed by percutaneous endovascular approach and one catheter was removed. In conclusion, for patients with central venous stenosis or occlusion and those who need a hemodialysis catheter, catheter insertion can be reliably achieved immediately after endovascular recannalization with acceptable technical and long-term success rates. This technique should be considered as an alternative procedure for placing a new hemodialysis catheter through a patent vein.
Resumo:
La infección asociada a inserción de catéter vascular, es un problema cotidiano en las UCI a nivel mundial, a pesar del manejo de protocolos que se han implementado de manera independiente en las distintas instituciones para frenar este fenómeno. El estudio, de tipo observacional, analítico y cohorte concurrente, con 151 pacientes, a los cuales se insertó catéter en la UCI de la Clínica San Pedro Claver.Para el análisis se realizó estadística descriptiva, análisis de sobrevida, pruebas de asociación y regresión de Cox.
Resumo:
Introducción: La utilización de catéteres venosos centrales (CVC) en la unidad de cuidado intensivo tiene gran importancia y amplio uso, son fuente de apoyo para la realización de varia actividades, pero con un gran potencial de complicaciones, por lo cual es fundamental conocer todos los aspectos relacionados con su uso, para así poder controlarlas. Métodos: Realizamos un estudio descriptivo de corte transversal con el objetivo de caracterizar los pacientes que requirieron CVC en el Hospital Universitario Fundación Santa Fe de Bogotá durante junio de 2011 y mayo de 2013, describimos sus complicaciones asociadas tanto mecánicas como infecciosas, determinamos la tasa de bacteriemia, gérmenes causales y sus patrones de resistencia. Resultados: Se colocaron 2.286 CVC, el 52,9% en hombres, la media de edad fue 58,9 años. El total de las complicaciones ascienden al 4,5%, infecciosas 4,0% y mecánicas 0,6%. Dentro de las mecánicas solo encontramos inmediatas, no tardías. Con respecto a las infecciosas encontramos infección del sitio de inserción y bacteriemia. Se documentó una tasa de bacteriemia de 3,4 por 1000-días catéter en 2013, en disminución con respecto a 2012 (3,9) y 2011 (4,4). El microorganismo mas frecuentemente aislado fue el Staphylococcus Coagulasa Negativo con patrón usual de resistencia. Conclusión: Las complicaciones asociadas al uso de CVC en el HUFSFB, se presentan en menor frecuencia a las descritas internacionalmente; la tasa de bacteriemia asociada al CVC ha disminuido año tras año, posiblemente asociado al cuidado mas estricto posterior a la implementación de protocolos de manejo.
Resumo:
The risk for venous thromboembolism (VTE) in medical patients is high, but risk assessment is rarely performed because there is not yet a good method to identify candidates for prophylaxis. Purpose: To perform a systematic review about VTE risk factors (RFs) in hospitalized medical patients and generate recommendations (RECs) for prophylaxis that can be implemented into practice. Data sources: A multidisciplinary group of experts from 12 Brazilian Medical Societies searched MEDLINE, Cochrane, and LILACS. Study selection: Two experts independently classified the evidence for each RF by its scientific quality in a standardized manner. A risk-assessment algorithm was created based on the results of the review. Data synthesis: Several VTE RFs have enough evidence to support RECs for prophylaxis in hospitalized medical patients (eg, increasing age, heart failure, and stroke). Other factors are considered adjuncts of risk (eg, varices, obesity, and infections). According to the algorithm, hospitalized medical patients ≥40 years-old with decreased mobility, and ≥1 RFs should receive chemoprophylaxis with heparin, provided they don't have contraindications. High prophylactic doses of unfractionated heparin or low-molecular-weight-heparin must be administered and maintained for 6-14 days. Conclusions: A multidisciplinary group generated evidence-based RECs and an easy-to-use algorithm to facilitate VTE prophylaxis in medical patients. © 2007 Rocha et al, publisher and licensee Dove Medical Press Ltd.
Resumo:
Pós-graduação em Pediatria - FMB
Resumo:
Estudo transversal, realizado com 67 recém-nascidos internados em uma Unidade de Terapia Intensiva Neonatal de um hospital privado de São Paulo, entre julho e dezembro de 2010, submetidos a 84 inserções de Cateteres Centrais de Inserção Periférica (CCIP). Os objetivos foram descrever a prevalência de remoção não eletiva do cateter e seus motivos. Os dados foram coletados de prontuários médicos e do formulário de registro de informações sobre o cateter. A média de idade gestacional corrigida dos neonatos foi 32,8 semanas, peso 1.671,6 g e idade pós-natal 9,4 dias. A remoção não eletiva ocorreu em 33 (39,3%) cateteres, 13,1% por obstrução, 9,5% ruptura, 7,1% edema do membro, 6% suspeita de infecção, 1,2% tração acidental, 1,2% má perfusão e 1,2% extravasamento. A prevalência e os motivos de remoção não eletiva indicaram a necessidade de estratégias para a prevenção de complicações evitáveis relacionadas ao CCIP.
Resumo:
Intermittent low-dose heparinised saline flushes were found to be efficacious for maintaining patency of indwelling peripheral and central intravenous catheters in diabetic dogs. The catheters were flushed with 1 mL of 1 U/mL heparinised saline every two hours immediately following blood sample collection, or every 12 hours when not being used for sampling. Central catheters were flushed with saline solution first to clear the line before instillation of the heparinised saline. Patency of 54/57 (95%) of the peripheral catheters and 30/32 (94%) of the central catheters was achieved for up to 36 hours and five days, respectively. No phlebitis, or local or systemic infections were observed and, in each case, catheter failure was attributable to obstruction or extravasation. It is unlikely that there will be any contraindications to this flushing technique and its introduction may improve intravenous catheter survival and reduce catheter-associated complications in hospitalised dogs.