961 resultados para Cardiac output


Relevância:

70.00% 70.00%

Publicador:

Resumo:

Endurance exercise is widely assumed to improve cardiac function in humans. This project has determined cardiac function following endurance exercise for 6 (n = 30) or 12 ( n = 25) weeks in male Wistar rats (8 weeks old). The exercise protocol was 30 min/day at 0.8 km/h for 5 days/week with an endurance test on the 6th day by running at 1.2 km/h until exhaustion. Exercise endurance increased by 318% after 6 weeks and 609% after 12 weeks. Heart weight/kg body weight increased by 10.2% after 6 weeks and 24.1% after 12 weeks. Echocardiography after 12 weeks showed increases in left ventricular internal diameter in diastole (6.39 +/- 0.32 to 7.90 +/- 0.17 mm), systolic volume (49 +/- 7 to 83 +/- 11 mul) and cardiac output (75 +/- 3 to 107 +/- 8 ml/min) but not left wall thickness in diastole (1.74 +/- 0.07 to 1.80 +/- 0.06 mm). Isolated Langendorff hearts from trained rats displayed decreased left ventricular myocardial stiffness (22 +/- 1.1 to 19.1 +/- 0.3) and reduced purine efflux during pacing-induced workload increases. P-31-NMR spectroscopy in isolated hearts from trained rats showed decreased PCr and PCr/ATP ratios with increased creatine, AMP and ADP concentrations. Thus, this endurance exercise protocol resulted in physiological hypertrophy while maintaining or improving cardiac function.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Objective - The purpose of this study was to assess cardiac function and cell damage in intrauterine growth-restricted (IUGR) fetuses across clinical Doppler stages of deterioration. Study Design - One hundred twenty appropriate-for-gestational-age and 81 IUGR fetuses were classified in stages 1/2/3 according umbilical artery present/absent/reversed end-diastolic blood flow, respectively. Cardiac function was assessed by modified-myocardial performance index, early-to-late diastolic filling ratios, cardiac output, and cord blood B-type natriuretic peptide; myocardial cell damage was assessed by heart fatty acid–binding protein, troponin-I, and high-sensitivity C-reactive protein. Results - Modified-myocardial performance index, blood B-type natriuretic peptide, and early-to-late diastolic filling ratios were increased in a stage-dependent manner in IUGR fetuses, compared with appropriate-for-gestational-age fetuses. Heart fatty acid–binding protein levels were higher in IUGR fetuses at stage 3, compared with control fetuses. Cardiac output, troponin-I, and high-sensitivity C-reactive protein did not increase in IUGR fetuses at any stage. Conclusion - IUGR fetuses showed signs of cardiac dysfunction from early stages. Cardiac dysfunction deteriorates further with the progression of fetal compromise, together with the appearance of biochemical signs of cell damage.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

This laboratory session provides hands-on experience for students to visualize the beating human heart with ultrasound imaging. Simple views are obtained from which students can directly measure important cardiac dimensions in systole and diastole. This allows students to derive, from first principles, important measures of cardiac function, such as stroke volume, ejection fraction, and cardiac output. By repeating the measurements from a subject after a brief exercise period, an increase in stroke volume and ejection fraction are easily demonstrable, potentially with or without an increase in left ventricular end-diastolic volume (which indicates preload). Thus, factors that affect cardiac performance can readily be discussed. This activity may be performed as a practical demonstration and visualized using an overhead projector or networked computers, concentrating on using the ultrasound images to teach basic physiological principles. This has proved to be highly popular with students, who reported a significant improvement in their understanding of Frank-Starling's law of the heart with ultrasound imaging.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Impedance cardiography is an application of bioimpedance analysis primarily used in a research setting to determine cardiac output. It is a non invasive technique that measures the change in the impedance of the thorax which is attributed to the ejection of a volume of blood from the heart. The cardiac output is calculated from the measured impedance using the parallel conductor theory and a constant value for the resistivity of blood. However, the resistivity of blood has been shown to be velocity dependent due to changes in the orientation of red blood cells induced by changing shear forces during flow. The overall goal of this thesis was to study the effect that flow deviations have on the electrical impedance of blood, both experimentally and theoretically, and to apply the results to a clinical setting. The resistivity of stationary blood is isotropic as the red blood cells are randomly orientated due to Brownian motion. In the case of blood flowing through rigid tubes, the resistivity is anisotropic due to the biconcave discoidal shape and orientation of the cells. The generation of shear forces across the width of the tube during flow causes the cells to align with the minimal cross sectional area facing the direction of flow. This is in order to minimise the shear stress experienced by the cells. This in turn results in a larger cross sectional area of plasma and a reduction in the resistivity of the blood as the flow increases. Understanding the contribution of this effect on the thoracic impedance change is a vital step in achieving clinical acceptance of impedance cardiography. Published literature investigates the resistivity variations for constant blood flow. In this case, the shear forces are constant and the impedance remains constant during flow at a magnitude which is less than that for stationary blood. The research presented in this thesis, however, investigates the variations in resistivity of blood during pulsataile flow through rigid tubes and the relationship between impedance, velocity and acceleration. Using rigid tubes isolates the impedance change to variations associated with changes in cell orientation only. The implications of red blood cell orientation changes for clinical impedance cardiography were also explored. This was achieved through measurement and analysis of the experimental impedance of pulsatile blood flowing through rigid tubes in a mock circulatory system. A novel theoretical model including cell orientation dynamics was developed for the impedance of pulsatile blood through rigid tubes. The impedance of flowing blood was theoretically calculated using analytical methods for flow through straight tubes and the numerical Lattice Boltzmann method for flow through complex geometries such as aortic valve stenosis. The result of the analytical theoretical model was compared to the experimental impedance measurements through rigid tubes. The impedance calculated for flow through a stenosis using the Lattice Boltzmann method provides results for comparison with impedance cardiography measurements collected as part of a pilot clinical trial to assess the suitability of using bioimpedance techniques to assess the presence of aortic stenosis. The experimental and theoretical impedance of blood was shown to inversely follow the blood velocity during pulsatile flow with a correlation of -0.72 and -0.74 respectively. The results for both the experimental and theoretical investigations demonstrate that the acceleration of the blood is an important factor in determining the impedance, in addition to the velocity. During acceleration, the relationship between impedance and velocity is linear (r2 = 0.98, experimental and r2 = 0.94, theoretical). The relationship between the impedance and velocity during the deceleration phase is characterised by a time decay constant, ô , ranging from 10 to 50 s. The high level of agreement between the experimental and theoretically modelled impedance demonstrates the accuracy of the model developed here. An increase in the haematocrit of the blood resulted in an increase in the magnitude of the impedance change due to changes in the orientation of red blood cells. The time decay constant was shown to decrease linearly with the haematocrit for both experimental and theoretical results, although the slope of this decrease was larger in the experimental case. The radius of the tube influences the experimental and theoretical impedance given the same velocity of flow. However, when the velocity was divided by the radius of the tube (labelled the reduced average velocity) the impedance response was the same for two experimental tubes with equivalent reduced average velocity but with different radii. The temperature of the blood was also shown to affect the impedance with the impedance decreasing as the temperature increased. These results are the first published for the impedance of pulsatile blood. The experimental impedance change measured orthogonal to the direction of flow is in the opposite direction to that measured in the direction of flow. These results indicate that the impedance of blood flowing through rigid cylindrical tubes is axisymmetric along the radius. This has not previously been verified experimentally. Time frequency analysis of the experimental results demonstrated that the measured impedance contains the same frequency components occuring at the same time point in the cycle as the velocity signal contains. This suggests that the impedance contains many of the fluctuations of the velocity signal. Application of a theoretical steady flow model to pulsatile flow presented here has verified that the steady flow model is not adequate in calculating the impedance of pulsatile blood flow. The success of the new theoretical model over the steady flow model demonstrates that the velocity profile is important in determining the impedance of pulsatile blood. The clinical application of the impedance of blood flow through a stenosis was theoretically modelled using the Lattice Boltzman method (LBM) for fluid flow through complex geometeries. The impedance of blood exiting a narrow orifice was calculated for varying degrees of stenosis. Clincial impedance cardiography measurements were also recorded for both aortic valvular stenosis patients (n = 4) and control subjects (n = 4) with structurally normal hearts. This pilot trial was used to corroborate the results of the LBM. Results from both investigations showed that the decay time constant for impedance has potential in the assessment of aortic valve stenosis. In the theoretically modelled case (LBM results), the decay time constant increased with an increase in the degree of stenosis. The clinical results also showed a statistically significant difference in time decay constant between control and test subjects (P = 0.03). The time decay constant calculated for test subjects (ô = 180 - 250 s) is consistently larger than that determined for control subjects (ô = 50 - 130 s). This difference is thought to be due to difference in the orientation response of the cells as blood flows through the stenosis. Such a non-invasive technique using the time decay constant for screening of aortic stenosis provides additional information to that currently given by impedance cardiography techniques and improves the value of the device to practitioners. However, the results still need to be verified in a larger study. While impedance cardiography has not been widely adopted clinically, it is research such as this that will enable future acceptance of the method.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Introduction Critical care patients frequently receive blood transfusions. Some reports show an association between aged or stored blood and increased morbidity and mortality, including the development of transfusion-related acute lung injury (TRALI). However, the existence of conflicting data endorses the need for research to either reject this association, or to confirm it and elucidate the underlying mechanisms. Methods Twenty-eight sheep were randomised into two groups, receiving saline or lipopolysaccharide (LPS). Sheep were further randomised to also receive transfusion of pooled and heat-inactivated supernatant from fresh (Day 1) or stored (Day 42) non-leucoreduced human packed red blood cells (PRBC) or an infusion of saline. TRALI was defined by hypoxaemia during or within two hours of transfusion and histological evidence of pulmonary oedema. Regression modelling compared physiology between groups, and to a previous study, using stored platelet concentrates (PLT). Samples of the transfused blood products also underwent cytokine array and biochemical analyses, and their neutrophil priming ability was measured in vitro. Results TRALI did not develop in sheep that first received saline-infusion. In contrast, 80% of sheep that first received LPS-infusion developed TRALI following transfusion with "stored PRBC." The decreased mean arterial pressure and cardiac output as well as increased central venous pressure and body temperature were more severe for TRALI induced by "stored PRBC" than by "stored PLT." Storage-related accumulation of several factors was demonstrated in both "stored PRBC" and "stored PLT", and was associated with increased in vitro neutrophil priming. Concentrations of several factors were higher in the "stored PRBC" than in the "stored PLT," however, there was no difference to neutrophil priming in vitro. Conclusions In this in vivo ovine model, both recipient and blood product factors contributed to the development of TRALI. Sick (LPS infused) sheep rather than healthy (saline infused) sheep predominantly developed TRALI when transfused with supernatant from stored but not fresh PRBC. "Stored PRBC" induced a more severe injury than "stored PLT" and had a different storage lesion profile, suggesting that these outcomes may be associated with storage lesion factors unique to each blood product type. Therefore, the transfusion of fresh rather than stored PRBC may minimise the risk of TRALI.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Background Less invasive methods of determining cardiac output are now readily available. Using indicator dilution technique, for example has made it easier to continuously measure cardiac output because it uses the existing intra-arterial line. Therefore gone is the need for a pulmonary artery floatation catheter and with it the ability to measure left atrial and left ventricular work indices as well the ability to monitor and measure a mixed venous saturation (SvO2). Purpose The aim of this paper is to put forward the notion that SvO2 provides valuable information about oxygen consumption and venous reserve; important measures in the critically ill to ensure oxygen supply meets cellular demand. In an attempt to portray this, a simplified example of the septic patient is offered to highlight the changing pathophysiological sequelae of the inflammatory process and its importance for monitoring SvO2. Relevance to clinical practice SvO2 monitoring, it could be argued, provides the gold standard for assessing arterial and venous oxygen indices in the critically ill. For the bedside ICU nurse the plethora of information inherent in SvO2 monitoring could provide them with important data that will assist in averting potential problems with oxygen delivery and consumption. However, it has been suggested that central venous saturation (ScvO2) might be an attractive alternative to SvO2 because of its less invasiveness and ease of obtaining a sample for analysis. There are problems with this approach and these are to do with where the catheter tip is sited and the nature of the venous admixture at this site. Studies have shown that ScvO2 is less accurate than SvO2 and should not be used as a sole guiding variable for decision-making. These studies have demonstrated that there is an unacceptably wide range in variance between ScvO2 and SvO2 and this is dependent on the presenting disease, in some cases SvO2 will be significantly lower than ScvO2. Conclusion Whilst newer technologies have been developed to continuously measure cardiac output, SvO2 monitoring is still an important adjunct to clinical decision-making in the ICU. Given the information that it provides, seeking alternatives such as ScvO2 or blood samples obtained from femorally placed central venous lines, can unnecessarily lead to inappropriate treatment being given or withheld. Instead when using ScvO2, trending of this variable should provide clinical determinates that are useable for the bedside ICU nurse, remembering that in most conditions SvO2 will be approximately 16% lower.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Cold water immersion (CWI) and active recovery (ACT) are frequently used as post-exercise recovery strategies. However, the physiological effects of CWI and ACT after resistance exercise are not well characterized. We examined the effects of CWI and ACT on cardiac output (Q), muscle oxygenation (SmO2) and blood volume (tHb), muscle temperature (Tmuscle ) and isometric strength after resistance exercise. On separate days, 10 men performed resistance exercise, followed by 10 min CWI at 10°C or 10 min ACT (low-intensity cycling). Q (7.9±2.7 l) and Tmuscle (2.2±0.8ºC) increased, whereas SmO2 (-21.5±8.8%) and tHb (-10.1±7.7 μM) decreased after exercise (p<0.05). During CWI, Q ̇(-1.1±0.7 l) and Tmuscle (-6.6±5.3ºC) decreased, while tHb (121±77 μM) increased (p<0.05). In the hour after CWI, Q ̇and Tmuscle remained low, while tHb also decreased (p<0.05). By contrast, during ACT, Q ̇(3.9±2.3 l), Tmuscle (2.2±0.5ºC), SmO2 (17.1±5.7%) and tHb (91±66 μM) all increased (p<0.05). In the hour after ACT, Tmuscle and tHb remained high (p<0.05). Peak isometric strength during 10 s maximum voluntary contractions (MVCs) did not change significantly after CWI, whereas it decreased after ACT (-30 to -45 Nm; p<0.05). Muscle deoxygenation time during MVCs increased after ACT (p<0.05), but not after CWI. Muscle reoxygenation time after MVCs tended to increase after CWI (p=0.052). These findings suggest firstly that hemodynamics and muscle temperature after resistance exercise are dependent on ambient temperature and metabolic demands with skeletal muscle, and secondly, that recovery of strength after resistance exercise is independent of changes in hemodynamics and muscle temperature.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Sydämen krooninen vajaatoiminta on merkittävä maailmanlaajuinen ongelma. Se on erilaisten sydän- ja verisuonisairauksien aiheuttama monimuotoinen oireyhtymä. Sydämen vasemman kammion hypertrofia eli sydämen seinämien paksuuntuminen on yksi keskeinen tekijä, joka voi olla sydämen vajaatoiminnan taustalla. Kohonnut verenpaine on yleisin syy, joka johtaa sydänlihaksen paksuuntumiseen. Tämä johtaa sydämen pumppaustoiminnan häiriintymiseen, erilaisten neurohormonaalisten mekanismien aktivaatioon ja edelleen sydämen vajaatoimintaan. Sydämen vajaatoiminnan neurohormonaalisista mekanismeista tärkeimmät ovat reniini-angiotensiini-aldosteroni-järjestelmän ja sympaattisen hermoston aktivaatio, sydämen rakenteiden uudelleenmuovautuminen, sydänlihassolujen apoptoosi ja systeeminen tulehdustila. Sydämen hypertrofiaa ja sen syntymistä pyritään estämään kohonneen verenpaineen lääkehoidolla. Reniini-angiotensiini-aldosteronijärjestelmällä on keskeinen merkitys sydämen vajaatoiminnassa. Sydämen vajaatoiminnan ennusteeseen vaikuttavista lääkeaineista angiotensiinikonvertasin estäjät (ACEestäjät) ovat säilyttäneet johtoasemansa jo vuosikymmenten ajan. Angiotensiinireseptoreiden salpaajien (AT1-salpaajien) odotettiin syrjäyttävän ACE-estäjät sydämen vajaatoiminnan hoidossa, mutta toistaiseksi niitä pidetään vain vaihtoehtoisina lääkkeinä. Sympaattisen hermoston aktivaatiota vähentävät β-salpaajat ovat vakiinnuttaneet asemansa toiseksi tärkeimpänä lääkeryhmänä. Diureetit ovat paljon käytetty lääkeaineryhmä sydämen vajaatoiminnan hoidossa, mutta niistä ainoastaan aldosteroniantagonisteilla on tutkitusti ennustetta parantavaa vaikutusta. Kroonisen vajaatoiminnan hoidossa käytetään edelleen myös digoksiinia. Tulevaisuudessa sydämen vajaatoiminnan ennusteeseen vaikuttavia lääkeaineita voivat olla reniinin estäjät, neutraaliendopeptidaasin estäjät, vasopressiinin antagonistit tai inflammatroisiin sytokiineihin vaikuttavat molekyylit. Erikoistyön kokeellisessa osiossa tarkoituksena oli tutkia sydämen hypertrofian kehittymistä vatsa-aortta kuristetuilla rotilla ja kalsiumherkistäjä levosimendaanin sekä AT1-salpaaja valsartaanin vaikutuksia hypertrofian kehittymiseen. Kokeellisessa osiossa arvioitiin myös sydämen hypertrofian ja vajaatoiminnan jyrsijämallina käytetyn vatsa-aortan kuristuksen (koarktaation) toimivuutta ja vaikutuksia ultraäänen avulla määritettyihin kardiovaskulaarisiin parametreihin. Vatsa-aortta kuristettiin munuaisvaltimoiden yläpuolelta. Kuristus saa aikaan verenpaineen kohoamisen ja sydämen työtaakan lisääntymisen. Pitkittyessään tila johtaa sydänlihaksen hypertrofiaan ja vajaatoimintaan. 64 eläintä jaettiin ryhmiin, siten että jokaiseen ryhmään tuli kahdeksan eläintä. Ryhmistä kolmelle annettiin lääkeaineena levosimendaania kolmella eri päiväannoksella (0,01 mg/kg; 0,10 mg/kg; 1,00 mg/kg) ja kolmelle valsartaania kolmella eri päiväannoksella (0,10 mg/kg; 1,00 mg/kg; 10,00 mg/kg) juomaveden mukana. Lääkitys aloitettiin leikkauksen jälkeen ja jatkettiin kahdeksan viikon ajan. Kardiovaskulaariset parametrit, kuten isovolumetrinen relaksaatioaika (IVRT), vasemman kammion läpimitta systolessa ja diastolessa sekä seinämäpaksuudet, ejektiofraktio (EF), supistuvuusosuus (FS), minuuttitilavuus (CO) ja iskutilavuus (SV) määritettiin kahdeksan viikon kuluttua leikkauksesta ultraäänitutkimuksen avulla. Lisäksi määritettiin eläinten sydämen paino suhteessa ruumiin painoon. Tuloksia verrattiin ilman lääkehoitoa olleeseen koarktaatioryhmään. Eläinmallin toimivuutta arvioitiin vertaamalla koarktaatioryhmän tuloksia sham-operoidun ryhmän tuloksiin. Levosimendaanilla havaittiin työssä sydämen systolista toimintaa parantava vaikutus. Tämä näkyi tendenssinä parantaa ejektiofraktioita ja vasemman kammion supistuvuusosuuksia. Sydämen diastoliseen toimintaan ei kummallakaan lääkeaineella ollut merkittävää vaikutusta. Diastolista toimintaa arvioitiin isovolumetrisen relaksaatioajan muutoksilla. Sydämen hypertrofian kehittymiseen ei kummallakaan lääkeaineella ollut merkittävää vaikutusta. Eläinmallin todettiin mallintavan hyvin sydämen hypetrofiaa ihmisellä, mutta ei niinkään sydämen vajaatoimintaa.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Intra-aortic balloon pumping is a counter pulsation technique for temporary circulatory assistance in cardiogenic shock and other low cardiac output conditions. Conventional systems use a balloon at the end of a catheter driven by a solenoid valve, controlled by patient's ECG or ventricular pressure signal. This results in time delay introducted by solenoid spool inertia, gas inertia, and hysteresis effects of the solenoid. Fluidics, because of their non-moving part operation and high switching speeds, minimizes the inertial effects while contributing high reliability. This communication describes a fluidic system developed for driving the balloon accepting electric control signals.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Objective: Although dobutamine is widely used in neonatal clinical practice, the evidence for its use in this specific population is not clear. We conducted a systematic review of the use of dobutamine in juvenile animals to determine whether the evidence from juvenile animal experiments with dobutamine supported the design of clinical trials in neonatal/ paediatric population. Methods: Studies were identified by searching MEDLINE (1946-2012) and EMBASE (1974-2012). Articles retrieved were independently reviewed by three authors and only those concerning efficacy and safety of the drug in juvenile animals were included. Only original articles published in English and Spanish were included. Results: Following our literature search, 265 articles were retrieved and 24 studies were included in the review: 17 focused on neonatal models and 7 on young animal models. Although the aims and design of these studies, as well as the doses and ages analysed, were quite heterogeneous, the majority of authors agree that dobutamine infusion improves cardiac output in a dose dependent manner. Moreover, the cardiovascular effects of dobutamine are influenced by postnatal age, as well as by the dose used and the duration of the therapy. There is inadequate information about the effects of dobutamine on cerebral perfusion to draw conclusions. Conclusion: There is enough preclinical evidence to ensure that dobutamine improves cardiac output, however to better understand its effects in peripheral organs, such as the brain, more specific and well designed studies are required to provide additional data to support the design of clinical trials in a paediatric population.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

A hipotensão pós-exercício (HPE) é um fenômeno de relevância clínica, mas dúvidas persistem no tocante ao efeito do modo e da forma de execução (contínua vs. acumulada) do exercício aeróbio para sua manifestação, bem como o papel do controle autonômico cardíaco como mecanismo fisiológico associado à HPE. Assim, a presente tese objetivou: a) investigar a HPE induzida por sessões aeróbias de exercício isocalórico contínuo e acumulado; b) comparar as respostas de pressão arterial sistólica (PAS) e diastólica (PAD) após teste cardiopulmonar de exercício máximo (TCPE) em três modalidades; c) verificar a influência do modo de exercício e do controle autonômico cardíaco em repouso sobre a reativação vagal após TCPE. No primeiro estudo, 10 homens saudáveis (idade: 27,6 3,5 anos) realizaram TCPEs de corrida e ciclismo para medida do consumo de oxigênio de pico (VO2pico) e sessões contínuas (400 kcal) e acumuladas (2 x 200 kcal) de corrida e ciclismo à 75%VO2reserva. A PAS e PAD reduziram similarmente após exercício contínuo e acumulado (4,6 2,3 vs. 5,2 2,3 mmHg, 2,6 2,5 vs. 3,6 2,5 mmHg, respectivamente, P > 0,05). Porém, a corrida provocou maior declínio na PAS do que o ciclismo (P < 0.05). A atividade simpática (componente de baixa frequência, LF) e parassimpática (componente de alta frequência, HF) aumentou (P < 0,001) e diminuiu (P < 0,001) em relação à sessão controle, elevando o balanço simpato-vagal (razão LF:HF) (P < 0,001) que foi inversamente correlacionado ao ΔPAS e ΔPAD (r = -0,41 a -0,70; P < 0.05). No segundo e terceiro estudos, 20 homens saudáveis (idade: 21.2 3.0 anos) realizaram três TCPEs (ciclismo, caminhada e corrida). No segundo estudo, investigou-se a resposta aguda da PA, débito cardíaco (Q), resistência vascular periférica (RVP), sensibilidade do barorreflexo arterial (SBR), variabilidade da frequência cardíaca (VFC) e dispêndio energético durante 60 min após os TCPEs e sessão controle. Comparado ao controle, somente a corrida modalidade envolvendo maior dispêndio energético total (P < 0,001) - foi capaz de reduzir a PAS no pós-exercício (P < 0,001). Mudanças na RVP, SBR, LF, e razão LF:HF foram negativamente correlacionadas às variações na PAS (-0,69 a -0,91; P < 0,001) e PAD (-0,58 a -0,93; P ≤ 0,002). No terceiro estudo, examinou-se a reativação parassimpática após cada TCPE pela raiz quadrada da média do quadrado das diferenças entre intervalos R-R normais adjacentes em janelas de 30 s (rMSSD30s). Apesar da menor FCpico, VO2pico e dispêndio energético no ciclismo vs. caminhada e corrida (P < 0,001), a reativação parassimpática foi significativamente mais rápida após o ciclismo (P < 0,05). Outrossim, o Δ rMSSD30-180s foi positivamente correlacionado ao HF (rs = 0,90 a 0,93; P < 0,001) e negativamente correlacionado ao LF e a razão LF:HF medidos no repouso (rs = -0,73 a -0,79 e -0,86 a -0,90, respectivamente; P < 0,001). Em conclusão, a forma de execução do exercício aeróbio não interfere na magnitude da HPE, mas a HPE é dependente do modo ou o volume total de exercício. Os resultados também indicam que o padrão de recuperação do controle autonômico cardíaco pela análise espectral da VFC pode ter um papel importante na indução da HPE.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Cardiovascular pathophysiological changes, such as hypertension and enlarged ventricles, reflect the altered functions of the heart and its circulation during ill-health. This article examines the normal and altered anatomy of the cardiac valves, the contractile elements and enzymes of the myocardium, the significance of the different factors associated with cardiac output, and the role of the autonomic nervous system in the heart beat. It also explores how certain diseases alter these functions and result in cardiac symptoms. Nurses can benefit from knowledge of these specific changes, for example, by being able to ask relevant questions in order to ascertain the nature of a patients condition, by being able to take an effective patient history and by being able to read diagnostic results, such as electrocardiograms and cardiac enzyme results. All this will help nurses to promote sound cardiac care based on a physiological rationale.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The hypoxia-inducible factors (HIFs; isoforms HIF-1 alpha, HIF-2 alpha, HIF-3 alpha) mediate many responses to hypoxia. Their regulation is principally by oxygen-dependent degradation, which is initiated by hydroxylation of specific proline residues followed by binding of von Hippel-Lindau (VHL) protein. Chuvash polycythemia is a disorder with elevated HIF. It arises through germline homozygosity for hypomorphic VHL alleles and has a phenotype of hematological, cardiopulmonary, and metabolic abnormalities. This study explores the phenotype of two other HIF pathway diseases: classic VHL disease and HIF-2 alpha gain-of-function mutation. No cardiopulmonary abnormalities were detected in classic VHL disease. HIF-2 alpha gain-of-function mutations were associated with pulmonary hypertension, increased cardiac output, increased heart rate, and increased pulmonary ventilation relative to metabolism. Comparison of the HIF-2 alpha gain-of-function responses with data from studies of Chuvash polycythemia suggested that other aspects of the Chuvash phenotype were diminished or absent. In classic VHL disease, patients are germline heterozygous for mutations in VHL, and the present results suggest that a single wild-type allele for VHL is sufficient to maintain normal cardiopulmonary function. The HIF-2 alpha gain-of-function phenotype may be more limited than the Chuvash phenotype either because HIF-1 alpha is not elevated in the former condition, or because other HIF-independent functions of VHL are perturbed in Chuvash polycythemia.-Formenti, F., Beer, P. A., Croft, Q. P. P., Dorrington, K. L., Gale, D. P., Lappin, T. R. J., Lucas, G. S., Maher, E. R., Maxwell, P. H., McMullin, M. F., O'Connor, D. F., Percy, M. J., Pugh, C. W., Ratcliffe, P. J., Smith, T. G., Talbot, N. P., Robbins, P. A. Cardiopulmonary function in two human disorders of the hypoxia-inducible factor (HIF) pathway: von Hippel-Lindau disease and HIF-2 alpha gain-of-function mutation. FASEB J. 25, 2001-2011 (2011). www.fasebj.org

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The central and peripheral cardiovascular effects of synthetic trout urotensin II (UII) were investigated in the conscious rainbow trout. Intracerebroventricular injection of 50 pmol UII produced a slight (3%) but significant (P < 0.05) increase in heart rate but had no effect on mean arterial blood pressure. Injection of 500 pmol UII icy produced a significant (P < 0.05) rise (8%) in blood pressure with no change in heart rate. In contrast to the weak presser effect of centrally administered UII, intra-arterial injection of UII produced a dose-dependent increase in arterial blood pressure and decrease in heart rate with significant (P < 0.05) effects on both parameters observed at a dose of 25 pmol. Higher doses of the peptide produced a sustained decrease in cardiac output that accompanied the bradycardia and rise in arterial blood pressure. The UII-induced bradycardia, but not the increase in pressure, was abolished by pretreatment with phentolamine. Trout UII produced a sustained and dose-dependent contraction of isolated vascular rings prepared from trout efferent branchial [-log 50% of the concentration producing maximal contraction (pD(2)) = 8.30] and celiacomesenteric (pD(2) = 8.22) arteries but was without effects on vascular rings from the anterior cardinal vein. The data indicate that the presser effect of UII in trout is mediated predominantly, if not exclusively, by an increase in systemic vascular resistance. The UII-induced hypertensive response does not seem to involve release of catecholamines, but the bradycardia may arise from adrenergic-mediated activation of cardioinhibitory baroreflexes.