988 resultados para Capacitively coupled contactless conductivity detection
Resumo:
Ibuprofen is one of the most used active pharmaceutical ingredients worldwide. A new method for the analysis of ibuprofen and its metabolites, hydroxyibuprofen and carboxyibuprofen, in soils is presented. The extraction of these compounds from the soil matrices was performed by using a modified quick, easy, cheap, effective, rugged, and safe (QuEChERS) method. The method involves a single extraction of the investigated compounds with purified water (acidified at pH 2.5 with hydrochloric acid), and a slow and continuous addition of the QuEChERS content, followed by the addition of acidified acetonitrile (1% acetic acid), prior to the determination by liquid chromatography coupled with fluorescence detection (LC–FLD). Validation studies were carried out using soil samples with a range of organic carbon contents. Recoveries of the fortified samples ranged from 79.5% to 101%. Relative standard deviations for all matrix–compound combinations did not exceed 3%. The method quantification limits were ≤22.4 μg kg−1 in all cases. The developed method was applied to the analysis of sixteen real samples.
Resumo:
Ochratoxin A (OTA) is a mycotoxin produced by a variety of fungi, such as Penicillium verrucosum and Aspergillium spp., which has been found to have a wide number of potentially deadly toxic effects, and can enter the human organism through a variety of means. It then finds its way into the bloodstream and, after a lengthy process, is eventually excreted through the urine. It can thus be detected in its original form not only in blood samples but also in this biological medium. As such, and in an attempt to evaluate the exposure of the Portuguese population to this mycotoxin, morning urine samples were collected during the Winter of 2007, from each of five geographically distinct Portuguese locations — Bragança, Porto, Coimbra, Alentejo, and Algarve — and subjected to extraction by immunoaffinity columns and to OTA quantification through liquid chromatography coupled with fluorescence detection. Prevalent incidence was higher than 95% with Coimbra being the exception (incidence of 73.3%). In nearly all locations, the OTA content of most samples was found to be above the limit of quantification (LOQ) of 0.008 ng/ml. Indeed, excluding Coimbra, with an OTA content level of 0.014 ng/ml, all regions featured content values over 0.021 ng/ml.
Resumo:
Ibuprofen is amongst the most worldwide consumed pharmaceuticals. The present work presents the first data in the occurrence of ibuprofen in Portuguese surface waters, focusing in the north area of the country, which is one of the most densely populated areas of Portugal. Analysis of ibuprofen is based on pre-concentration of the analyte with solid phase extraction and subsequent determination with liquid chromatography coupled to fluorescence detection. A total of 42 water samples, including surface waters, landfill leachates,Wastewater Treatment Plant (WWTP), and hospital effluents, were analyzed in order to evaluate the occurrence of ibuprofen in the north of Portugal. In general, the highest concentrations were found in the river mouths and in the estuarine zone. The maximum concentrations found were 48,720 ngL−1 in the landfill leachate, 3,868 ngL−1 in hospital effluent, 616 ngL−1 in WWTP effluent, and 723 ngL−1 in surface waters (Lima river). Environmental risk assessment was evaluated and at the measured concentrations only landfill leachates reveal potential ecotoxicological risk for aquatic organisms. Owing to a high consumption rate of ibuprofen among Portuguese population, as prescribed and nonprescribed medicine, the importance of hospitals, WWTPs, and landfills as sources of entrance of pharmaceuticals in the environment was pointed out. Landfill leachates showed the highest contribution for ibuprofen mass loading into surface waters. On the basis of our findings, more studies are needed as an attempt to assess more vulnerable areas.
Resumo:
NanoPT 2014 International Conference, in Portugal, on February 12-14. Poster presentation based on topic Nanobio/Nanomedicine
Resumo:
New products available for food creations include a wide variety of "supposed" food grade aerosol sprays. However, the gas propellants used cannot be considered as safe. The different legislations available did not rule any maximum residue limits, even though these compounds have some limits when used for other food purposes. This study shows a preliminary monitoring of propane, butane and dimethyl ether residues, in cakes and chocolate after spraying, when these gases are used as propellants in food aerosol sprays. Release kinetics of propane, butane and dimethyl ether were measured over one day with sprayed food, left at room temperature or in the fridge after spraying. The alkanes and dimethyl ether analyses were performed by headspace-gas chromatography-mass spectrometry/thermal conductivity detection, using monodeuterated propane and butane generated in situ as internal standards. According to the obtained results and regardingthe extrapolations of the maximum residue limits existing for these substances, different delays should be respected according to the storage conditions and the gas propellant to consume safely the sprayed food.
Resumo:
INTRODUCTION: The analysis of glucosinolates (GS) is traditionally performed by reverse-phase liquid chromatography coupled to ultraviolet detection after a time-consuming desulphation step, which is required for increased retention. Simpler and more efficient alternative methods that can shorten both sample preparation and analysis are much needed. OBJECTIVE: To evaluate the feasibility of using ultrahigh-pressure liquid chromatography coupled to quadrupole time-of-flight mass spectrometry (UHPLC-QTOFMS) for the rapid profiling of intact GS. METHODOLOGY: A simple and short extraction of GS from Arabidopsis thaliana leaves was developed. Four sub-2 µm reverse-phase columns were tested for the rapid separation of these polar compounds using formic acid as the chromatographic additive. High-resolution QTOFMS was used to detect and identify GS. RESULTS: A novel charged surface hybrid (CSH) column was found to provide excellent retention and separation of GS within a total running time of 11 min. Twenty-one GS could be identified based on their accurate mass as well as isotopic and fragmentation patterns. The method was applied to determine the changes in GS content that occur after herbivory in Arabidopsis. In addition, we evaluated its applicability to the profiling of other Brassicaceae species. CONCLUSION: The method developed can profile the full range of GS, including the most polar ones, in a shorter time than previous methods, and is highly compatible with mass spectrometric detection.
Resumo:
We present a study about the influence of substrate temperature on deposition rate of hydrogenated amorphous silicon thin films prepared by rf glow discharge decomposition of pure silane gas in a capacitively coupled plasma reactor. Two different behaviors are observed depending on deposition pressure conditions. At high pressure (30 Pa) the influence of substrate temperature on deposition rate is mainly through a modification of gas density, in such a way that the substrate temperature of deposition rate is similar to pressure dependence at constant temperature. On the contrary, at low pressure (3 Pa), a gas density effect cannot account for the observed increase of deposition rate as substrate temperature rises above 450 K with an activation energy of 1.1 kcal/mole. In accordance with laser‐induced fluorescence measurements reported in the literature, this rise has been ascribed to an increase of secondary electron emission from the growing film surface as a result of molecular hydrogen desorption.
Resumo:
New products available for food creations include a wide variety of "supposed" food grade aerosol sprays. However, the gas propellants used cannot be considered as safe. The different legislations available did not rule any maximum residue limits, even though these compounds have some limits when used for other food purposes. This study shows a preliminary monitoring of propane, butane and dimethyl ether residues, in cakes and chocolate after spraying, when these gases are used as propellants in food aerosol sprays. Release kinetics of propane, butane and dimethyl ether were measured over one day with sprayed food, left at room temperature or in the fridge after spraying. The alkanes and dimethyl ether analyses were performed by headspace-gas chromatography-mass spectrometry/thermal conductivity detection, using monodeuterated propane and butane generated in situ as internal standards. According to the obtained results and regardingthe extrapolations of the maximum residue limits existing for these substances, different delays should be respected according to the storage conditions and the gas propellant to consume safely the sprayed food.
Resumo:
Postmortem imaging consists in the non-invasive examination of bodies using medical imaging techniques. However, gas volume quantification and the interpretation of the gas collection results from cadavers remain difficult. We used whole-body postmortem multi-detector computed tomography (MDCT) followed by a full autopsy or external examination to detect the gaseous volumes in bodies. Gases were sampled from cardiac cavities, and the sample compositions were analyzed by headspace gas chromatography-mass spectrometry/thermal conductivity detection (HS-GC-MS/TCD). Three categories were defined according to the presumed origin of the gas: alteration/putrefaction, high-magnitude vital gas embolism (e.g., from scuba diving accident) and gas embolism of lower magnitude (e.g., following a traumatic injury). Cadaveric alteration gas was diagnosed even if only one gas from among hydrogen, hydrogen sulfide or methane was detected. In alteration cases, the carbon dioxide/nitrogen ratio was often >0.2, except in the case of advanced alteration, when methane presence was the best indicator. In the gas embolism cases (vital or not), hydrogen, hydrogen sulfide and methane were absent. Moreover, with high-magnitude vital gas embolisms, carbon dioxide content was >20%, and the carbon dioxide/nitrogen ratio was >0.2. With gas embolisms of lower magnitude (gas presence consecutive to a traumatic injury), carbon dioxide content was <20% and the carbon dioxide/nitrogen ratio was often <0.2. We found that gas analysis provided useful assistance to the postmortem imaging diagnosis of causes of death. Based on the quantifications of gaseous cardiac samples, reliable indicators were determined to document causes of death. MDCT examination of the body must be performed as quickly as possible, as does gas sampling, to avoid generating any artifactual alteration gases. Because of cardiac gas composition analysis, it is possible to distinguish alteration gases and gas embolisms of different magnitudes.
Resumo:
BACKGROUND: Diagnosis of pheochromocytoma (PC) is based on a combination of clinical suspicion, finding an adrenal mass, increased plasma, and urine concentrations of catecholamine metabolites and is finally confirmed with histopathology. In human medicine, it is controversial whether biochemically testing plasma is superior to testing urine. OBJECTIVES: To measure urinary and plasma catecholamines and metanephrines in healthy dogs, dogs with PC, hypercortisolism (HC), and nonadrenal diseases (NAD) and to determine the test with the best diagnostic performance for dogs with PC. ANIMALS: Seven PC dogs, 10 dogs with HC, 14 dogs with NAD, 10 healthy dogs. METHODS: Prospective diagnostic clinical study. Urine and heparin plasma samples were collected and stored at -80°C before analysis using high-pressure liquid chromatography (HPLC) coupled to electrochemical detection or tandem mass spectrometry were performed. Urinary variables were expressed as ratios to urinary creatinine concentration. RESULTS: Dogs with PC had significantly higher urinary normetanephrine and metanephrine : creatinine ratios and significantly higher plasma-total and free normetanephrine and plasma-free metanephrine concentrations compared to the 3 other groups. There were no overlapping results of urinary normetanephrine concentrations between PC and all other groups, and only one PC dog with a plasma normetanephrine concentration in the range of the dogs with HC and NAD disease. Performances of total and free plasma variables were similar. Overlap of epinephrine and norepinephrine results between the groups was large with both urine and plasma. CONCLUSION AND CLINICAL IMPORTANCE: Measurement of normetanephrine is the preferred biochemical test for PC and urine was superior to plasma.
Resumo:
The chemical composition of rainwater samples collected from March 2002 to February 2003 in downtown São Paulo city (Universidade Presbiteriana Mackenzie) is presented. Potentiometric and conductimetric measurements were used to evaluate the [H+] and the total ionic content. Major anions and cations were determined by ion chromatography with conductivity detection. The rainwater was acidic with a mean pH of 4.99. The volume weighted means, VWM, of the anions nitrate, acetate and sulfate were, respectively, 21.2, 16.9 and 12.4 µmol L-1. Ammonium was the most abundant ion with a VWM of 37.6 µmol L-1. The contribution of each anion to the free acidity potential decreases in the following order: SO4(2-) (28.8%), CH3COO- (24.7%), NO3- (22.8%), Cl- (13.4%), HCOO- (7.7%) and C2O4(2-) (2.5%). The relative contribution of the weak organic acids to the free acidity was significant, 34.9%.
Resumo:
The oxidation of sulphur compounds upon burning emits large quantities of SOx into the atmosphere. Therefore, there is growing interest in fast and accurate methods for analyzing sulphur content in fuels. The objective of this work was to compare four different methods of total sulphur determination in solid fuels. The methods used in this work were Eschka, Infrared, Thermal Conductivity Detection (TCD) and Ultraviolet Fluorescence Detection (UV). The preliminary results showed that TCD and UV methods (nonstandard methods for solid fuels) have similar precision to the infrared method (standard method) for high-sulphur coal samples.
Resumo:
In the present study, we analyzed DNA damage induced by phycocyanin (PHY) in the presence of visible light (VL) using a set of repair endonucleases purified from Escherichia coli. We demonstrated that the profile of DNA damage induced by PHY is clearly different from that induced by molecules that exert deleterious effects on DNA involving solely singlet oxygen as reactive species. Most of PHY-induced lesions are single strand breaks and, to a lesser extent, base oxidized sites, which are recognized by Nth, Nfo and Fpg enzymes. High pressure liquid chromatography coupled to electrochemical detection revealed that PHY photosensitization did not induce 8-oxo-7,8-dihydro-2'-deoxyguanosine (8-oxodGuo) at detectable levels. DNA repair after PHY photosensitization was also investigated. Plasmid DNA damaged by PHY photosensitization was used to transform a series of Saccharomyces cerevisiae DNA repair mutants. The results revealed that plasmid survival was greatly reduced in rad14 mutants, while the ogg1 mutation did not modify the plasmid survival when compared to that in the wild type. Furthermore, plasmid survival in the ogg1 rad14 double mutant was not different from that in the rad14 single mutant. The results reported here indicate that lethal lesions induced by PHY plus VL are repaired differently by prokaryotic and eukaryotic cells. Morever, nucleotide excision repair seems to play a major role in the recognition and repair of these lesions in Saccharomyces cerevisiae.
Resumo:
Dans les milieux contaminés par les métaux, les organismes vivants sont exposés à plusieurs d’entre eux en même temps. Les modèles courants de prédiction des effets biologiques des métaux sur les organismes (p. ex., modèle du ligand biotique, BLM ; modèle de l’ion libre, FIAM), sont des modèles d’équilibre chimique qui prévoient, en présence d'un deuxième métal, une diminution de la bioaccumulation du métal d’intérêt et par la suite une atténuation de ses effets. Les biomarqueurs de toxicité, tels que les phytochélatines (PCs), ont été utilisés comme étant un moyen alternatif pour l’évaluation des effets biologiques. Les phytochélatines sont des polypeptides riches en cystéine dont la structure générale est (γ-glu-cys)n-Gly où n varie de 2 à 11. Leur synthèse semble dépendante de la concentration des ions métalliques ainsi que de la durée de l’ exposition de l’organisme, aux métaux. L'objectif de cette étude était donc de déterminer, dans les mélanges binaires de métaux, la possibilité de prédiction de la synthèse des phytochélatines par les modèles d’équilibres chimiques, tel que le BLM. Pour cela, la quantité de phytochélatines produites en réponse d’une exposition aux mélanges binaires : Cd-Ca, Cd-Cu et Cd-Pb a été mesurée tout en surveillant l’effet direct de la compétition par le biais des concentrations de métaux internalisés. En effet, après six heures d’exposition, la bioaccumulation de Cd diminue en présence du Ca et de très fortes concentrations de Pb et de Cu (de l’ordre de 5×10-6 M). Par contre, avec des concentrations modérées de ces deux métaux, le Cd augmente en présence de Cu et ne semble pas affecté par la présence de Pb. Dans le cas de la compétition Cd-Cu, une bonne corrélation a été observée entre la production de PC2, PC3 et PC4 et la quantité des métaux bioaccumulés. Pour la synthèse des phytochélatines et la bioaccumulation, les effets étaient considérés comme synergiques. Dans le cas du Cd-Ca, les quantités de PC3 et PC4 ont diminué avec le métal internalisé (effet antagoniste), mais ce qui était remarquable était la grande quantité de cystéine (GSH) et PC2 qui ont été produites à de fortes concentrations du Ca. Le Pb seul n’a pas induit les PCs. Par conséquent, il n’y avait pas de variation de la quantité de PCs avec la concentration de Pb à laquelle les algues ont été exposées. La détection et la quantification des PCs ont été faites par chromatographie à haute performance couplée d’un détecteur de fluorescence (HPLC-FL). Tandis que les concentrations métalliques intracellulaires ont été analysées par spectroscopie d’absorption atomique (AAS) ou par spectrométrie de masse à source plasma à couplage inductif (ICP-MS).
Resumo:
Le premier volet de ce travail portera sur l’expérience acquise lors d’un stage d’étude à Tokyo, au Japon, dans le groupe de recherche du Pr. Makoto Fujita, une sommité d’envergure internationale dans le domaine de l’auto-assemblage. En continuité avec les plus récents travaux du Pr. Fujita, des systèmes poreux auto-assemblés présentant des cavités fonctionnalisées ont été développés dans le but d’encapsuler des acides gras afin d’en déterminer la structure cristalline. Ces éponges ont été caractérisées par des techniques courantes telles que la spectroscopie à résonance magnétique nucléaire 1H, 13C{1H} et Cosy, la spectrométrie de masse, l’analyse élémentaire, la microscopie optique infrarouge ainsi que la diffraction des rayons X. Une autre approche employée pour obtenir de meilleures propriétés spectroscopiques fut la synthèse de dendrimères métalliques de génération 0. Un nouveau ligand de type 1,3,5-triazine a été synthétisé par une réaction typique de cyclisation de nitrile en présence catalytique d’hydrure de sodium. Des espèces mono-, bis- et trinucléaire de Ru(II) furent synthétisés ainsi que deux espèces hétérométalliques de Ru(II)/Pt(II) et de Ru(II)/Os(II). Tous les complexes obtenus furent caractérisés par spectroscopie à résonance magnétique nucléaire (1H, 13C{1H} et Cosy) à l’état liquide, par spectroscopie de masse à haute résolution et par analyse élémentaire. La génération de dihydrogène à partir de l’espèce hétérométallique a été étudiée. Les propriétés optiques et électroniques ont été analysées par spectroscopie UV-Vis, par analyse de la luminescence, du temps de vie de luminescence, par des analyses de rendement quantique ainsi que par des analyses de voltampérométrie cyclique à balayage. Finalement, dans le but d’améliorer les propriétés spectroscopiques d’absorption de complexes métalliques, nous avons synthétisé une série de polymères homo- et hétérométalliques, intégrant des ligands de type bis(2,2’:6,2’’-terpyridine). Les complexes générés furent caractérisés par diverses techniques tel que la spectroscopie à résonance magnétique nucléaire (1H, 13C{1H} et Cosy) à l’état liquide, par spectroscopie de masse à haute résolution ainsi que par analyse élémentaire. Les propriétés optiques et électroniques ont été analysées par spectroscopie UV-Vis, par analyse de la luminescence, du temps de vie de luminescence, par des analyses de rendement quantique ainsi que par des analyses de voltampérométrie cyclique à balayage.