983 resultados para Calibration plot
Resumo:
This paper describes the trigger and offline reconstruction, identification and energy calibration algorithms for hadronic decays of tau leptons employed for the data collected from pp collisions in 2012 with the ATLAS detector at the LHC center-of-mass energy s√ = 8 TeV. The performance of these algorithms is measured in most cases with Z decays to tau leptons using the full 2012 dataset, corresponding to an integrated luminosity of 20.3 fb−1. An uncertainty on the offline reconstructed tau energy scale of 2% to 4%, depending on transverse energy and pseudorapidity, is achieved using two independent methods. The offline tau identification efficiency is measured with a precision of 2.5% for hadronically decaying tau leptons with one associated track, and of 4% for the case of three associated tracks, inclusive in pseudorapidity and for a visible transverse energy greater than 20 GeV. For hadronic tau lepton decays selected by offline algorithms, the tau trigger identification efficiency is measured with a precision of 2% to 8%, depending on the transverse energy. The performance of the tau algorithms, both offline and at the trigger level, is found to be stable with respect to the number of concurrent proton--proton interactions and has supported a variety of physics results using hadronically decaying tau leptons at ATLAS.
Resumo:
FUNDAMENTO: O tabagismo altera a função autonômica. OBJETIVO: Investigar os efeitos agudos do tabagismo sobre a modulação autonômica e a recuperação dos índices de variabilidade de frequência cardíaca (VFC) pós-fumo, por meio do plot de Poincaré e índices lineares. MÉTODOS: Foram avaliados 25 fumantes jovens, os quais tiveram a frequência cardíaca analisada, batimento a batimento, na posição sentada, após 8 horas de abstinência, por 30 minutos em repouso, 20 minutos durante o fumo e 30 minutos pós-fumo. Análise de variância para medidas repetidas, seguido do teste de Tukey, ou teste de Friedman seguido do teste de Dunn foram aplicados dependendo da normalidade dos dados, com p < 0,05. RESULTADOS: Durante o fumo, houve redução dos índices SD1 (23,4 ± 9,2 vs 13,8 ± 4,8), razão SD1/SD2 (0,31 ± 0,08 vs 0,2 ± 0,04), RMSSD (32,7 ± 13 vs 19,1 ± 6,8), SDNN (47,6 ± 14,8 vs 35,5 ± 8,4), HFnu (32,5 ± 11,6 vs 19 ± 8,1) e do intervalo RR (816,8 ± 89 vs 696,5 ± 76,3) em relação ao repouso, enquanto que aumentos do índice LFnu (67,5 ± 11,6 vs 81 ± 8,1) e da razão LF/HF (2,6 ± 1,7 vs 5,4 ± 3,1) foram observados. A análise visual do plot mostrou menor dispersão dos intervalos RR durante o fumo. Com exceção da razão SD1/SD2, os demais índices apresentaram recuperação dos valores, 30 minutos após o tabagismo. CONCLUSÃO: O tabagismo produziu agudamente modificações no controle autonômico, caracterizadas por ativação simpática e retirada vagal, com recuperação 30 minutos após o fumo.
Resumo:
We show how to calibrate CES production and utility functions when indirect taxation affecting inputs and consumption is present. These calibrated functions can then be used in computable general equilibrium models. Taxation modifies the standard calibration procedures since any taxed good has two associated prices and a choice of reference value units has to be made. We also provide an example of computer code to solve the calibration of CES utilities under two alternate normalizations. To our knowledge, this paper fills a methodological gap in the CGE literature.
Resumo:
Una Plot Suite és una aplicació web que permet localitzar plots d’una Base de Dades a partir de formularis. S’obtindran taules on apareixeran els plots amb les seves característiques i es podrà obtenir còpies dels plots sol·licitats. Gràcies al seu disseny es podran afegir nous plots a la Base de Dades i fins i tot modificar l’estructura d’una manera molt intuïtiva.
Resumo:
An accurate sense of time contributes to functions ranging from the perception and anticipation of sensory events to the production of coordinated movements. However, accumulating evidence demonstrates that time perception is subject to strong illusory distortion. In two experiments, we investigated whether the subjective speed of temporal perception is dependent on our visual environment. By presenting human observers with speed-altered movies of a crowded street scene, we modulated performance on subsequent production of "20s" elapsed intervals. Our results indicate that one's visual environment significantly contributes to calibrating our sense of time, independently of any modulation of arousal. This plasticity generates an assay for the integrity of our sense of time and its rehabilitation in clinical pathologies.
Resumo:
The sensitivity of altitudinal and latitudinal tree-line ecotones to climate change, particularly that of temperature, has received much attention. To improve our understanding of the factors affecting tree-line position, we used the spatially explicit dynamic forest model TreeMig. Although well-suited because of its landscape dynamics functions, TreeMig features a parabolic temperature growth response curve, which has recently been questioned. and the species parameters are not specifically calibrated for cold temperatures. Our main goals were to improve the theoretical basis of the temperature growth response curve in the model and develop a method for deriving that curve's parameters from tree-ring data. We replaced the parabola with an asymptotic curve, calibrated for the main species at the subalpine (Swiss Alps: Pinus cembra, Larix decidua, Picea abies) and boreal (Fennoscandia: Pinus sylvestris, Betula pubescens, P. abies) tree-lines. After fitting new parameters, the growth curve matched observed tree-ring widths better. For the subalpine species, the minimum degree-day sum allowing, growth (kDDMin) was lowered by around 100 degree-days; in the case of Larix, the maximum potential ring-width was increased to 5.19 mm. At the boreal tree-line, the kDDMin for P. sylvestris was lowered by 210 degree-days and its maximum ring-width increased to 2.943 mm; for Betula (new in the model) kDDMin was set to 325 degree-days and the maximum ring-width to 2.51 mm; the values from the only boreal sample site for Picea were similar to the subalpine ones, so the same parameters were used. However, adjusting the growth response alone did not improve the model's output concerning species' distributions and their relative importance at tree-line. Minimum winter temperature (MinWiT, mean of the coldest winter month), which controls seedling establishment in TreeMig, proved more important for determining distribution. Picea, P. sylvestris and Betula did not previously have minimum winter temperature limits, so these values were set to the 95th percentile of each species' coldest MinWiT site (respectively -7, -11, -13). In a case study for the Alps, the original and newly calibrated versions of TreeMig were compared with biomass data from the National Forest Inventor), (NFI). Both models gave similar, reasonably realistic results. In conclusion, this method of deriving temperature responses from tree-rings works well. However, regeneration and its underlying factors seem more important for controlling species' distributions than previously thought. More research on regeneration ecology, especially at the upper limit of forests. is needed to improve predictions of tree-line responses to climate change further.
Resumo:
In Switzerland, individuals exposed to the risk of activity intake are required to perform regular monitoring. Monitoring consists in a screening measurement and is meant to be performed using commonly available laboratory instruments. More particularly, iodine intake is measured using a surface contamination monitor. The goal of the present paper is to report the calibration method developed for thyroid screening instruments. It consists of measuring the instrument response to a known activity located in the thyroid gland of a standard neck phantom. One issue of this procedure remains that the iodine radioisotopes have a short half-life. Therefore, the adequacy and limitations to simulate the short-lived radionuclides with so-called mock radionuclides of longer half-life were also evaluated. In light of the results, it has been decided to use only the appropriate iodine sources to perform the calibration.
Resumo:
The subtribe Gentianinae comprises ca. 425 species, most of them within the well-studied genus Gentiana and mainly distributed over the Eurasian continent. Phylogenetic relationships between Gentiana and its closest relatives, the climbing gentians (Crawfurdia, Tripterospermum) and the new genus Metagentiana, remain unclear. All three genera were recently found to be polyphyletic, possibly because of poor sampling of Tripterospermum and Crawfurdia. Highest diversity of Gentianinae occurs in the western Himalaya, but the absence of uncontroversial fossil evidence limits our understanding of its biogeography. In the present study, we generated ITS and atpB-rbcL sequences for 19 species of Tripterospermum, 9 of Crawfurdia and 11 of Metagentiana, together representing about 60 percent of the species diversity of these genera. Our results show that only Metagentiana is polyphyletic and divided into three monophyletic entities. No unambiguous synapomorphies were associated with the three Metagentiana entities. Different combinations of three approximate calibration points were used to generate three divergence time estimation scenarios. Although dating hypotheses were mostly inconsistent, they concurred in associating radiation of Gentiana to an orogenic phase of the Himalaya between 15 and 10 million years ago. Our study illustrates the conceptual difficulties in addressing the time frame of diversification in a group lacking sufficient fossil number and quality.
Resumo:
The Hardy-Weinberg law, formulated about 100 years ago, states that under certainassumptions, the three genotypes AA, AB and BB at a bi-allelic locus are expected to occur inthe proportions p2, 2pq, and q2 respectively, where p is the allele frequency of A, and q = 1-p.There are many statistical tests being used to check whether empirical marker data obeys theHardy-Weinberg principle. Among these are the classical xi-square test (with or withoutcontinuity correction), the likelihood ratio test, Fisher's Exact test, and exact tests in combinationwith Monte Carlo and Markov Chain algorithms. Tests for Hardy-Weinberg equilibrium (HWE)are numerical in nature, requiring the computation of a test statistic and a p-value.There is however, ample space for the use of graphics in HWE tests, in particular for the ternaryplot. Nowadays, many genetical studies are using genetical markers known as SingleNucleotide Polymorphisms (SNPs). SNP data comes in the form of counts, but from the countsone typically computes genotype frequencies and allele frequencies. These frequencies satisfythe unit-sum constraint, and their analysis therefore falls within the realm of compositional dataanalysis (Aitchison, 1986). SNPs are usually bi-allelic, which implies that the genotypefrequencies can be adequately represented in a ternary plot. Compositions that are in exactHWE describe a parabola in the ternary plot. Compositions for which HWE cannot be rejected ina statistical test are typically “close" to the parabola, whereas compositions that differsignificantly from HWE are “far". By rewriting the statistics used to test for HWE in terms ofheterozygote frequencies, acceptance regions for HWE can be obtained that can be depicted inthe ternary plot. This way, compositions can be tested for HWE purely on the basis of theirposition in the ternary plot (Graffelman & Morales, 2008). This leads to nice graphicalrepresentations where large numbers of SNPs can be tested for HWE in a single graph. Severalexamples of graphical tests for HWE (implemented in R software), will be shown, using SNPdata from different human populations
Resumo:
Catadioptric sensors are combinations of mirrors and lenses made in order to obtain a wide field of view. In this paper we propose a new sensor that has omnidirectional viewing ability and it also provides depth information about the nearby surrounding. The sensor is based on a conventional camera coupled with a laser emitter and two hyperbolic mirrors. Mathematical formulation and precise specifications of the intrinsic and extrinsic parameters of the sensor are discussed. Our approach overcomes limitations of the existing omni-directional sensors and eventually leads to reduced costs of production
Resumo:
In epidemiologic studies, measurement error in dietary variables often attenuates association between dietary intake and disease occurrence. To adjust for the attenuation caused by error in dietary intake, regression calibration is commonly used. To apply regression calibration, unbiased reference measurements are required. Short-term reference measurements for foods that are not consumed daily contain excess zeroes that pose challenges in the calibration model. We adapted two-part regression calibration model, initially developed for multiple replicates of reference measurements per individual to a single-replicate setting. We showed how to handle excess zero reference measurements by two-step modeling approach, how to explore heteroscedasticity in the consumed amount with variance-mean graph, how to explore nonlinearity with the generalized additive modeling (GAM) and the empirical logit approaches, and how to select covariates in the calibration model. The performance of two-part calibration model was compared with the one-part counterpart. We used vegetable intake and mortality data from European Prospective Investigation on Cancer and Nutrition (EPIC) study. In the EPIC, reference measurements were taken with 24-hour recalls. For each of the three vegetable subgroups assessed separately, correcting for error with an appropriately specified two-part calibration model resulted in about three fold increase in the strength of association with all-cause mortality, as measured by the log hazard ratio. Further found is that the standard way of including covariates in the calibration model can lead to over fitting the two-part calibration model. Moreover, the extent of adjusting for error is influenced by the number and forms of covariates in the calibration model. For episodically consumed foods, we advise researchers to pay special attention to response distribution, nonlinearity, and covariate inclusion in specifying the calibration model.
Resumo:
BACKGROUND: Prevention of cardiovascular disease (CVD) at the individual level should rely on the assessment of absolute risk using population-specific risk tables. OBJECTIVE: To compare the predictive accuracy of the original and the calibrated SCORE functions regarding 10-year cardiovascular risk in Switzerland. DESIGN: Cross-sectional, population-based study (5773 participants aged 35-74 years). METHODS: The SCORE equation for low-risk countries was calibrated based on the Swiss CVD mortality rates and on the CVD risk factor levels from the study sample. The predicted number of CVD deaths after a 10-year period was computed from the original and the calibrated equations and from the observed cardiovascular mortality for 2003. RESULTS: According to the original and calibrated functions, 16.3 and 15.8% of men and 8.2 and 8.9% of women, respectively, had a 10-year CVD risk > or =5%. Concordance correlation coefficient between the two functions was 0.951 for men and 0.948 for women, both P<0.001. Both risk functions adequately predicted the 10-year cumulative number of CVD deaths: in men, 71 (original) and 74 (calibrated) deaths for 73 deaths when using the CVD mortality rates; in women, 44 (original), 45 (calibrated) and 45 (CVD mortality rates), respectively. Compared to the original function, the calibrated function classified more women and fewer men at high-risk. Moreover, the calibrated function gave better risk estimates among participants aged over 65 years. CONCLUSION: The original SCORE function adequately predicts CVD death in Switzerland, particularly for individuals aged less than 65 years. The calibrated function provides more reliable estimates for older individuals.
Resumo:
El projecte tracta de la fabricació d’un robot mòbil que sigui capaç de realitzar el mapeig d’una superfície, evitant els obstacles que es pugui trobar en el transcurs del seu recorregut. És un projecte complex, per aquest motiu la part de procés de dades s'ha fet en un projecte posterior. Aquesta memòria tracta del muntatge i calibració dels components, a més de la realització dels algorismes de control dels mateixos, per tal de realitzar el mapeig de la superfície, aconseguint així l’objectiu plantejat.
Resumo:
New zircon U-Pb ages are proposed for late Early and Middle Triassic volcanic ash layers from the Luolou and Baifeng formations (northwestern Guangxi, South China). These ages are based on analyses of single, thermally annealed and chemically abraded zircons. Calibration with ammonoid ages indicate a 250.6 +/- 0.5 Ma age for the early Spathian Tirolites/Columbites beds, a 248.1 +/- 0.4 Ma age for the late Spathian Neopopanoceras haugi Zone, a 246.9 +/- 0.4 Ma age for the early middle Anisian Acrochordiceras hyatti Zone, and a 244.6 +/- 0.5 Ma age for the late middle Anisian Balatonites shoshonensis Zone. The new dates and previously published U-Pb ages indicate a duration of ca. 3 my for the Spathian, and minimal durations of 4.5 +/- 0.6 my for the Early Triassic and of 6.6+0.7/-0.9 my for the Anisian. The new Spathian dates are in a better agreement with a 252.6 +/- 0.2 Ma age than with a 251.4 +/- 0.3 Ma age for the Permian-Triassic boundary. These dates also highlight the extremely uneven duration of the four Early Triassic substages (Griesbachian, Dienerian, Smithian, and Spathian), of which the Spathian exceeds half of the duration of the entire Early Triassic. The simplistic assumption of equal duration of the four Early Triassic subdivisions is no longer tenable for the reconstruction of recovery patterns following the end Permian mass extinction. (c) 2006 Elsevier B.V. All rights reserved.
Resumo:
Measurement of three-dimensional (3D) knee joint angle outside a laboratory is of benefit in clinical examination and therapeutic treatment comparison. Although several motion capture devices exist, there is a need for an ambulatory system that could be used in routine practice. Up-to-date, inertial measurement units (IMUs) have proven to be suitable for unconstrained measurement of knee joint differential orientation. Nevertheless, this differential orientation should be converted into three reliable and clinically interpretable angles. Thus, the aim of this study was to propose a new calibration procedure adapted for the joint coordinate system (JCS), which required only IMUs data. The repeatability of the calibration procedure, as well as the errors in the measurement of 3D knee angle during gait in comparison to a reference system were assessed on eight healthy subjects. The new procedure relying on active and passive movements reported a high repeatability of the mean values (offset<1 degrees) and angular patterns (SD<0.3 degrees and CMC>0.9). In comparison to the reference system, this functional procedure showed high precision (SD<2 degrees and CC>0.75) and moderate accuracy (between 4.0 degrees and 8.1 degrees) for the three knee angle. The combination of the inertial-based system with the functional calibration procedure proposed here resulted in a promising tool for the measurement of 3D knee joint angle. Moreover, this method could be adapted to measure other complex joint, such as ankle or elbow.