953 resultados para Ca-Si Ceramics, Bioactivity, Bone Tissue Engineering


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Bone defects in revision knee arthroplasty are often located in load-bearing regions. The goal of this study was to determine whether a physiologic load could be used as an in situ osteogenic signal to the scaffolds filling the bone defects. In order to answer this question, we proposed a novel translation procedure having four steps: (1) determining the mechanical stimulus using finite element method, (2) designing an animal study to measure bone formation spatially and temporally using micro-CT imaging in the scaffold subjected to the estimated mechanical stimulus, (3) identifying bone formation parameters for the loaded and non-loaded cases appearing in a recently developed mathematical model for bone formation in the scaffold and (4) estimating the stiffness and the bone formation in the bone-scaffold construct. With this procedure, we estimated that after 3 years mechanical stimulation increases the bone volume fraction and the stiffness of scaffold by 1.5- and 2.7-fold, respectively, compared to a non-loaded situation.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Different cell sources for bone tissue engineering are reviewed. In particular, adult cell source strategies have been based on the implantation of unfractionated fresh bone marrow; purified, culture expanded mesenchymal stem cells, differentiated osteoblasts, or cells that have been modified genetically to express rhBMP. Several limiting factors are mentioned for these strategies such as low number of available cells or possible immunological reaction of the host. Foetal bone cells are presented as an alternative solution and review of actual treatments using these cells is presented. Finally, foetal cells used specifically for bone tissue engineering are characterised and potentially interesting therapeutic options are proposed.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The release of growth factors from tissue engineering scaffolds provides signals that influence the migration, differentiation, and proliferation of cells. The incorporation of a drug delivery platform that is capable of tunable release will give tissue engineers greater versatility in the direction of tissue regeneration. We have prepared a novel composite of two biomaterials with proven track records - apatite and poly(lactic-co-glycolic acid) (PLGA) – as a drug delivery platform with promising controlled release properties. These composites have been tested in the delivery of a model protein, bovine serum albumin (BSA), as well as therapeutic proteins, recombinant human bone morphogenetic protein-2 (rhBMP-2) and rhBMP-6. The controlled release strategy is based on the use of a polymer with acidic degradation products to control the dissolution of the basic apatitic component, resulting in protein release. Therefore, any parameter that affects either polymer degradation or apatite dissolution can be used to control protein release. We have modified the protein release profile systematically by varying the polymer molecular weight, polymer hydrophobicity, apatite loading, apatite particle size, and other material and processing parameters. Biologically active rhBMP-2 was released from these composite microparticles over 100 days, in contrast to conventional collagen sponge carriers, which were depleted in approximately 2 weeks. The released rhBMP-2 was able to induce elevated alkaline phosphatase and osteocalcin expression in pluripotent murine embryonic fibroblasts. To augment tissue engineering scaffolds with tunable and sustained protein release capabilities, these composite microparticles can be dispersed in the scaffolds in different combinations to obtain a superposition of the release profiles. We have loaded rhBMP-2 into composite microparticles with a fast release profile, and rhBMP-6 into slow-releasing composite microparticles. An equi-mixture of these two sets of composite particles was then injected into a collagen sponge, allowing for dual release of the proteins from the collagenous scaffold. The ability of these BMP-loaded scaffolds to induce osteoblastic differentiation in vitro and ectopic bone formation in a rat model is being investigated. We anticipate that these apatite-polymer composite microparticles can be extended to the delivery of other signalling molecules, and can be incorporated into other types of tissue engineering scaffolds.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Titanium alloy scaffolds for bone tissue engineering are receiving increasing attention because their porous structure and mechanical properties can be adjusted to match those of bone. In particular, there is an enormous potential to increase the life of such implant material if the porous structure can be imparted with shape memory properties. In the present study, TiNi scaffolds with a porous structure and high porosities up to 75% were fabricated by powder metallurgy. The porous structure was characterized by scanning electron microscope. The mechanical properties, the shape memory and superelastic effects were investigated by differential scanning calorimetry, nanoindentation and compressive tests. Results indicate that the porous TiNi scaffolds display an open-cell porous structure which provides new bone tissue ingrowth ability. The mechanical properties of the TiNi scaffolds can be tailored to match those of natural bone. Furthermore, the TiNi scaffolds show good shape memory and superelastic effects.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Titanium–nickel (TiNi) shape memory alloy (SMA) foams with an open-cell porous structure were fabricated by space-holder sintering process and characterized by scanning electron microscopy (SEM) and X-ray diffraction (XRD) analysis. The mechanical properties and shape memory properties of the TiNi foam samples were investigated using compressive test. Results indicate that the plateau stresses and elastic moduli of the foams under compression decrease with the increase of their porosities. The plateau stresses and elastic moduli are measured to be from 1.9 to 38.3 MPa and from 30 to 860 MPa for the TiNi foam samples with porosities ranged from 71% to 87%, respectively. The mechanical properties of the TiNi alloy foams can be tailored to match those of bone. The TiNi alloy foams exhibit shape memory effect (SME), and it is found that the recoverable strain due to SME decreases with the increase of foam porosity.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Porous titanium (Ti) and titanium alloys are promising scaffold biomaterials for bone tissue engineering, because they have the potential to provide new bone tissue ingrowth abilities and low elastic modulus to match that of
natural bone. In the present study, a new highly porous Ti6Ta4Sn alloy scaffold with the addition of biocompatible alloying elements (tantalum (Ta) and tin (Sn)) was prepared using a space-holder sintering method. The
strength of the Ti6Ta4Sn scaffold with a porosity of 75% was found to be significantly higher than that of a pure Ti scaffold with the same porosity. The elastic modulus of the porous alloy can be customized to match that of
human bone by adjusting its porosity. In addition, the porous Ti6Ta4Sn alloy exhibited an interconnected porous structure, which enabled the ingrowth of new bone tissues. Cell culture results revealed that human SaOS2
osteoblast-like cells grew and spread well on the surfaces of the solid alloy, and throughout the porous scaffold. The surface roughness of the alloy showed a significant effect on the cell behavior, and the optimum surface
roughness range for the adhesion of the SaOS2 cell on the alloy was 0.15 to 0.35 mm. The present study illustrated the feasibility of using the porous Ti6Ta4Sn alloy scaffold as an orthopedic implant material with a special
emphasis on its excellent biomechanical properties and in vitro biocompatibility with a high preference by osteoblast-like cells.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In this paper, porous Ti14Nb4Sn alloys were fabricated using a space holder sintering method, resulting in a porosity of ~70%. Scanning electron microscopy (SEM) analyses revealed a combination of both macropore and micropore structures. The fabricated titanium alloy scaffolds exhibited a similar structure to that of natural bone, which is expected to improve bone implant longevity. Bacterial cells of Pseudomonas aeruginosa ATCC 9027 were employed for the in vitro test.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)