996 resultados para Bubb, Daniel K
Resumo:
Cryocoolers have been progressively replacing the use of the stored cryogens in cryogenic chains used for detector cooling, thanks to their higher and higher reliability. However, the mechanical vibrations, the electromagnetic interferences and the temperature fluctuations inherent to their functioning could reduce the sensor’s sensitivity. In order to minimize this problem, compact thermal energy storage units (ESU) are studied, devices able to store thermal energy without significant temperature increase. These devices can be used as a temporary cold source making it possible to turn the cryocooler OFF providing a proper environment for the sensor. A heat switch is responsible for the thermal decoupling of the ESU from the cryocooler’s temperature that increases when turned OFF. In this work, several prototypes working around 40 K were designed, built and characterized. They consist in a low temperature cell that contains the liquid neon connected to an expansion volume at room temperature for gas storage during the liquid evaporation phase. To turn this system insensitive to the gravity direction, the liquid is retained in the low temperature cell by capillary effect in a porous material. Thanks to pressure regulation of the liquid neon bath, 900 J were stored at 40K. The higher latent heat of the liquid and the inexistence of triple point transitions at 40 K turn the pressure control during the evaporation a versatile and compact alternative to an ESU working at the triple point transitions. A quite compact second prototype ESU directly connected to the cryocooler cold finger was tested as a temperature stabilizer. This device was able to stabilize the cryocooler temperature ((≈ 40K ±1 K) despite sudden heat bursts corresponding to twice the cooling power of the cryocooler. This thesis describes the construction of these devices as well as the tests performed. It is also shown that the thermal model developed to predict the thermal behaviour of these devices, implemented as a software,describes quite well the experimental results. Solutions to improve these devices are also proposed.
Resumo:
Cryocoolers have been progressively replacing the use of the stored cryogens in cryogenic chains used for detector cooling, thanks to their higher and higher reliability. However, the mechanical vibrations, the electromagnetic interferences and the temperature fluctuations inherent to their functioning could reduce the sensor’s sensitivity. In order to minimize this problem, compact thermal energy storage units (ESU) are studied, devices able to store thermal energy without significant temperature increase. These devices can be used as a temporary cold source making it possible to turn the cryocooler OFF providing a proper environment for the sensor. A heat switch is responsible for the thermal decoupling of the ESU from the cryocooler’s temperature that increases when turned OFF. In this work, several prototypes working around 40 K were designed, built and characterized. They consist in a low temperature cell that contains the liquid neon connected to an expansion volume at room temperature for gas storage during the liquid evaporation phase. To turn this system insensitive to the gravity direction, the liquid is retained in the low temperature cell by capillary effect in a porous material. Thanks to pressure regulation of the liquid neon bath, 900 J were stored at 40K. The higher latent heat of the liquid and the inexistence of triple point transitions at 40 K turn the pressure control during the evaporation a versatile and compact alternative to an ESU working at the triple point transitions. A quite compact second prototype ESU directly connected to the cryocooler cold finger was tested as a temperature stabilizer. This device was able to stabilize the cryocooler temperature ((≈ 40K ±1 K) despite sudden heat bursts corresponding to twice the cooling power of the cryocooler. This thesis describes the construction of these devices as well as the tests performed. It is also shown that the thermal model developed to predict the thermal behaviour of these devices,implemented as a software, describes quite well the experimental results. Solutions to improve these devices are also proposed.
Resumo:
v.1:no.10(1898)
Resumo:
SPME-GC-MS, PCA and HCA multivariate techniques were used in order to evaluate their applicability to discriminate the three chemotypes (thymol, carvacrol and mixed) described for L. graveolens of Guatemala. The leaves of L. graveolens are used for treatment of colds, bronchitis, and as seasoning for food preparations, yielding essential oil up to 4.34 %. Leaves of 35 individuals from eight populations, and eight composite samples were analyzed using a DVB/Carboxen/PDMS fiber and GC-MS. PCA and HCA were carried out using eight markers (p-cymene, cis-sabinene hydrate, linalool, terpinen-4-ol, thymol, carvacrol, (E)-caryophyllene and caryophyllene oxide). The three chemotypes of L. graveolens were satisfactorily discriminated.
Resumo:
O presente estudo teve como objetivo avaliar a preparação das subamostras (sementes inteiras e cortadas), temperaturas (80 e 105ºC) e períodos de secagem (12, 24, 36, 48, 60, 72 e 96 horas) na determinação do grau de umidade de sementes de camu-camu. Paralelamente, foi avaliado o número de sementes por quilograma, visando a utilização da tabela de tolerâncias máximas permitidas para as diferenças entre duas subamostras, e analisada a variação dos resultados de grau de umidade entre subamostras de lotes de sementes. Desse modo, foi verificado que o número de sementes por quilograma é inferior a 5000 unidades e que 33% dos lotes ultrapassaram as tolerâncias de grau de umidade admitidas pelas Regras de Análise de Sementes brasileiras. Por outro lado, não foi possível estabelecer o método mais apropriado à determinação do grau de umidade das sementes dessa espécie, mas foram considerados como inadequados a combinação sementes cortadas/temperatura de 105ºC, em qualquer período de exposição, e as combinações de sementes inteiras e de sementes cortadas na temperatura de 80ºC/12 horas de exposição.
Resumo:
Les naines brunes sont des objets de masse intermédiaire entre celle nécessaire pour former une étoile et celle d'une planète. Les naines brunes sont classées, des plus chaudes aux plus froides, en types spectraux L, T et Y, caractérisés par une couleur J-K moyenne qui varie de 1.2 à 1.8 pour les étoiles de type L0 à L8, et de 1.8 à -0.5 pour les étoiles de type L8 à T8. Par ailleurs, la couleur J-K de certains types spectraux présente une dispersion de l'ordre d'une magnitude. Ce travail tente de faire la lumière sur la nature de cette grande dispersion, présente dans la couleur J-K des naines brunes de type L2. Les observations ont été réalisées avec la caméra infrarouge CPAPIR à l'Observatoire du Mont Mégantic. Nous avons ciblé un total de 22 naines brunes qui ont été observées en K, et 12 parmi celles-ci ont aussi été observées en J. Chacune des naines brunes a été calibrée à l'aide d'une étoile standard, ce qui rend nos résultats indépendants des données 2MASS. Nous observons une corrélation entre les couleurs J-K de nos données et de celles de 2MASS. Cela montre que la grande dispersion en J-K de nos données et des données 2MASS est due aux propriétés physiques des naines brunes et non à des erreurs observationnelles. L'examen des facteurs qui pourraient être responsables de cette grande dispersion, soit la classification spectrale, la métallicité, la gravité de surface, une binarité non résolue, la présence de nuages de condensats et la rotation, montre que la gravité de surface serait le facteur le plus susceptible d'être responsable de la grande dispersion des valeurs de J-K.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
A wealth of genetic associations for cardiovascular and metabolic phenotypes in humans has been accumulating over the last decade, in particular a large number of loci derived from recent genome wide association studies (GWAS). True complex disease-associated loci often exert modest effects, so their delineation currently requires integration of diverse phenotypic data from large studies to ensure robust meta-analyses. We have designed a gene-centric 50 K single nucleotide polymorphism (SNP) array to assess potentially relevant loci across a range of cardiovascular, metabolic and inflammatory syndromes. The array utilizes a "cosmopolitan" tagging approach to capture the genetic diversity across approximately 2,000 loci in populations represented in the HapMap and SeattleSNPs projects. The array content is informed by GWAS of vascular and inflammatory disease, expression quantitative trait loci implicated in atherosclerosis, pathway based approaches and comprehensive literature searching. The custom flexibility of the array platform facilitated interrogation of loci at differing stringencies, according to a gene prioritization strategy that allows saturation of high priority loci with a greater density of markers than the existing GWAS tools, particularly in African HapMap samples. We also demonstrate that the IBC array can be used to complement GWAS, increasing coverage in high priority CVD-related loci across all major HapMap populations. DNA from over 200,000 extensively phenotyped individuals will be genotyped with this array with a significant portion of the generated data being released into the academic domain facilitating in silico replication attempts, analyses of rare variants and cross-cohort meta-analyses in diverse populations. These datasets will also facilitate more robust secondary analyses, such as explorations with alternative genetic models, epistasis and gene-environment interactions.
Resumo:
The cellular mechanisms of calcification in sea urchin larvae are still not well understood. Primary mesenchyme cells within the larval body cavity form a syncytium to secrete CaCO3 spicules from intracellular amorphous CaCO3 (ACC) stores. We studied the role of Na+K+2Cl- cotransporter (NKCC) in intracellular ACC accumulation and larval spicule formation of Strongylocentrotus droebachiensis. First, we incubated growing larvae with three different loop diuretics (azosemide, bumetanide, and furosemide) and established concentration-response curves. All loop diuretics were able to inhibit calcification already at concentrations that specifically inhibit NKCC. Calcification was most effectively inhibited by azosemide (IC50 = 6.5 µM), while larval mortality and swimming ability were not negatively impacted by the treatment. The inhibition by bumetanide (IC50 = 26.4 µM) and furosemide (IC50 = 315.4 µM) resembled the pharmacological fingerprint of the mammalian NKCC1 isoform. We further examined the effect of azosemide on the maintenance of cytoplasmic cords and on the occurrence of calcification vesicles using fluorescent dyes (calcein, FM1-43). Fifty micromolars of azosemide inhibited the maintenance of cytoplasmic cords and resulted in increased calcein fluorescence within calcification vesicles. The expression of NKCC in S. droebachiensis was verified by PCR and Western blot with a specific NKCC antibody. In summary, the pharmacological profile of loop diuretics and their specific effects on calcification in sea urchin larvae suggest that they act by inhibition of NKCC via repression of cytoplasmic cord formation and maintenance.