941 resultados para Breathing-maneuvers


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: The Finometer (FMS, Finapres Measurement Systems, Amsterdam) records the beat-to-beat finger pulse contour and has been recommended for research studies assessing shortterm changes of blood pressure and its variability. Variability measured in the frequency domain using spectral analysis requires that the impact of breathing be restricted to high frequency spectra (> 0.15 Hz) so data from participants needs to be excluded when the breathing impact occurs in the low frequency spectra (0.04 - 0.15 Hz). This study tested whether breathing frequency can be estimated from standard Finometer recordings using either stroke volume oscillation frequency or spectral stroke volume variability maximum scores. Methods: 22 healthy volunteers were tested for 270s in the supine and upright positions. Finometer recorded the finger pulse contour and a respiratory transducer recorded breathing. Stoke volume oscillation frequency was calculated manually while the stroke volume spectral maximums were obtained using the software Cardiovascular Parameter Analysis (Nevrokard Kiauta, Izola, Slovenia). These estimates were compared to the breathing frequency using the Bland-Altman procedures. Results: Stroke volume oscillation frequency estimated breathing frequency to <±10% 95% levels of agreement in both supine (-7.7 to 7.0%) and upright (-6.7 to 5.4%) postures. Stroke volume variability maximum scores did not accurately estimate breathing frequency. Conclusions: Breathing frequency can be accurately derived from standard Finometer recordings using stroke volume oscillations for healthy individuals in both supine and upright postures. The Finometer can function as a standalone instrument in blood pressure variability studies and does not require support equipment to determine breathing frequency.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper reports on the analysis of tidal breathing patterns measured during noninvasive forced oscillation lung function tests in six individual groups. The three adult groups were healthy, with prediagnosed chronic obstructive pulmonary disease, and with prediagnosed kyphoscoliosis, respectively. The three children groups were healthy, with prediagnosed asthma, and with prediagnosed cystic fibrosis, respectively. The analysis is applied to the pressure–volume curves and the pseudophaseplane loop by means of the box-counting method, which gives a measure of the area within each loop. The objective was to verify if there exists a link between the area of the loops, power-law patterns, and alterations in the respiratory structure with disease. We obtained statistically significant variations between the data sets corresponding to the six groups of patients, showing also the existence of power-law patterns. Our findings support the idea that the respiratory system changes with disease in terms of airway geometry and tissue parameters, leading, in turn, to variations in the fractal dimension of the respiratory tree and its dynamics.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper reports on the analysis of tidal breathing patterns measured during noninvasive forced oscillation lung function tests in six individual groups. The three adult groups were healthy, with prediagnosed chronic obstructive pulmonary disease, and with prediagnosed kyphoscoliosis, respectively. The three children groups were healthy, with prediagnosed asthma, and with prediagnosed cystic fibrosis, respectively. The analysis is applied to the pressure-volume curves and the pseudophase-plane loop by means of the box-counting method, which gives a measure of the area within each loop. The objective was to verify if there exists a link between the area of the loops, power-law patterns, and alterations in the respiratory structure with disease. We obtained statistically significant variations between the data sets corresponding to the six groups of patients, showing also the existence of power-law patterns. Our findings support the idea that the respiratory system changes with disease in terms of airway geometry and tissue parameters, leading, in turn, to variations in the fractal dimension of the respiratory tree and its dynamics.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: Contemporary free-breathing non contrast enhanced cardiovascular magnetic resonance angiography (CMRA) was qualitatively and quantitatively evaluated to ascertain the reproducibility of the method for coronary artery luminal dimension measurements. SUBJECTS AND METHODS: Twenty-two healthy volunteers (mean age 32 +/- 7 years, 12 males) without coronary artery disease were imaged at 2 centers (1 each in Europe and North America) using navigator-gated and corrected SSFP CMRA on a commercial whole body 1.5T System. Repeat images of right (RCA, n = 21), left anterior descending (LAD, n = 14) and left circumflex (LCX, n = 14) coronary arteries were obtained in separate sessions using identical scan protocol and imaging parameters. True visible vessel length, signal-to-noise (SNR), contrast-to-noise ratios (CNR) and the average luminal diameter over the first 4 cm of the vessel were measured. Intra-observer, inter-observer and inter-scan reproducibility of coronary artery luminal diameter were determined using Pearson's correlation, Bland-Altman analysis and intraclass correlation coefficients (ICC). RESULTS: CNR, SNR and the mean length of the RCA, LAD and LCX imaged for original and repeat scans were not significantly different (all p > 0.30). There was a high degree of intra-observer, inter-observer and inter-scan agreements for RCA, LAD and LCX luminal diameter respectively on Bland-Altman and ICC analysis (ICC's for RCA: 0.98. 0.98 and 0.86; LAD: 0.89, 0.89 and 0.63; LCX: 0.95, 0.94 and 0.79). CONCLUSION: In a 2-center study, we demonstrate that free-breathing 3D SSFP CMRA can visualize long continuous segments of coronary vessels with highly reproducible measurements of luminal diameter.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Black-blood fast spin-echo imaging is a powerful technique for the evaluation of cardiac anatomy. To avoid fold-over artifacts, using a sufficiently large field of view in phase-encoding direction is mandatory. The related oversampling affects scanning time and respiratory chest motion artifacts are commonly observed. The excitation of a volume that exclusively includes the heart without its surrounding structures may help to improve scan efficiency and minimize motion artifacts. Therefore, and by building on previously reported inner-volume approach, the combination of a black-blood fast spin-echo sequence with a two-dimensionally selective radiofrequency pulse is proposed for selective "local excitation" small field of view imaging of the heart. This local excitation technique has been developed, implemented, and tested in phantoms and in vivo. With this method, small field of view imaging of a user-specified region in the human thorax is feasible, scanning becomes more time efficient, motion artifacts can be minimized, and additional flexibility in the choice of imaging parameters can be exploited.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Measurements and simulations were performed to assess workers' exposure to solvent vapors and aerosols during the waterproofing of a tiled surface. This investigation followed two recent incidents in the same company where workers experienced acute respiratory illness after spraying a stain-repellent resin containing fluorinated polymers on stone-tiled walls and floors. Because the waterproofing activity had been done for years at the tile company without encountering any exposure problems prior to these cases, it was strongly suspected that the incidents were linked to a recent change in the composition of the coating mixture. Experimental measurements and simulations indicated that the emission rate of particles smaller than 10 microm may be estimated at 0.66 mg/sec (SD 0.10) for the old resin and at 0.37 mg/sec (SD 0.04) for the new one. The measurement of the solvent emission rate from surfaces coated with the two resins indicated that shortly after spraying, the emission was in the range of 18 to 20 mg/sec x m2 and was similar for both products. Solvent and overspray emission rates were introduced in a two-zone compartment model. The results obtained in the near-field indicate significant exposure to overspray mist (7 and 34 mg/m3 for new resin) and solvent vapors (80 to 350 ppm for the new resin). It was also shown that the introduction of the new resin tended to significantly decrease the levels of solvents and particulates in the workers' breathing zone. These results strongly suggest that cases of acute respiratory illness are related to the specific toxicity of the fluorinated polymer itself. The fact that the same polymer is used in various commercial products raises concern regarding other possible occupational and domestic exposures.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction: Les troubles respiratoires du sommeil (TRS), qui représentent une préoccupation croissante pour la santé, ont des effets significatifs sur la santé, le comportement et la performance académique chez l’enfant. Les malformations craniofaciales, l’hypertrophie adéno-amygdalienne et l'obésité, représentent des facteurs de risque importants dans le développement de cette condition. Les symptômes des TRS ont été étudiés dans une étude prospective chez les enfants et adolescents durant leur traitement orthodontique dans un milieu universitaire. Cette étude a cherché à décrire la prévalence et les facteurs de risque principaux des TRS, ainsi que l'impact des différentes interventions orthodontiques sur les symptômes TRS. Matériel et méthodes: dans une étude cohorte prospective, un groupe de 168 sujets âgés de 12 à 21 ans ont été soumis, quatre ans après la prise de données initiale, à un examen craniofacial en plus d'être administré des questionnaires qui ont recueilli des données sur la situation socio-démographique, le bruxisme et les troubles d’ATM, le sommeil et le comportement diurne, et les facteurs neuropsychologiques. Résultats: l'indice de masse corporelle a été augmenté mais est demeurée dans la même catégorie aux deux moments de l'enquête. Il ya eu une augmentation du serrement des dents et des symptômes de l'ATM, une diminution de la taille des amygdales, et une augmentation de la somnolence diurne. La prévalence des TRS n'a pas changé entre l’étude initiale et l’étude de suivi. Aucune intervention orthodontique s'est avérée avoir un effet cliniquement significatif sur les voies aériennes supérieures. Conclusions: la prévalence des symptômes TRS était constante par rapport aux valeurs de base pour la population étudiée, mais a augmenté si rapportée à la population générale. Les traitements orthodontiques ne montrent aucun effet sur les TRS. Mots-clés : apnée du sommeil, craniofacial, prévalence, ronflement, traitement orthodontique, voies aériennes supérieures

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Mémoire numérisé par la Division de la gestion de documents et des archives de l'Université de Montréal

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction: L’expansion palatine du maxillaire a beaucoup d’effets positifs sur la respiration et la qualité du sommeil, mais peu d'études ont examiné ces données sur des adultes ayant dépassé l’âge permettant de bénéficier d'une expansion palatine conventionnelle. Le but de cette recherche est d’évaluer la stabilité de l’EPRAC (expansion palatine rapide assistée chirurgicalement) et son effet sur les troubles respiratoires après l’ablation des appareils orthodontiques. Méthodes: Neuf patients (Âge moyen 21, entre 16-39 ans) nécessitant une EPRAC ont passé des nuits dans un laboratoire de sommeil, et ce avant l’EPRAC, après l’EPRAC, et après l’ablation des appareils fixes. Les radiographies céphalométriques postéroantérieures ainsi que les modèles d’étude ont été pris pendant ces trois périodes de temps. Résultats: L’analyse des modèles d’étude a démontré une récidive significative au niveau des distances inter-molaires et inter-canines au niveau du maxillaire seulement. Les analyses céphalométriques ont démontré une récidive au niveau de la largeur maxillaire. Aucun changement important n'a été observé dans les stades de sommeil, mais une réduction importante dans l’index de ronflement a été notée. De plus, il y avait moins de changements entre les stades de sommeil. Conclusions: La récidive squelettique est minime et cliniquement non significative. Par contre, les changements dans les distances intermolaires et intercanines sont cliniquement importants. Il semble également qu'une EPRAC ait un effet positif sur la qualité de sommeil par la réduction de l’indice de ronflement ainsi que sur la diminution des changements entre les stades de sommeil.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The control of aerial gymnastic maneuvers is challenging because these maneuvers frequently involve complex rotational motion and because the performer has limited control of the maneuver during flight. A performer can influence a maneuver using a sequence of limb movements during flight. However, the same sequence may not produce reliable performances in the presence of off-nominal conditions. How do people compensate for variations in performance to reliably produce aerial maneuvers? In this report I explore the role that passive dynamic stability may play in making the performance of aerial maneuvers simple and reliable. I present a control strategy comprised of active and passive components for performing robot front somersaults in the laboratory. I show that passive dynamics can neutrally stabilize the layout somersault which involves an "inherently unstable" rotation about the intermediate principal axis. And I show that a strategy that uses open loop joint torques plus passive dynamics leads to more reliable 1 1/2 twisting front somersaults in simulation than a strategy that uses prescribed limb motion. Results are presented from laboratory experiments on gymnastic robots, from dynamic simulation of humans and robots, and from linear stability analyses of these systems.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction: During the past years, alveolar recruitment maneuvers (RM) have produced growing interest due to their beneficial potential in pulmonary protection, and have been introduced in clinical practice. Objective: To describe and analyze the knowledge of MR and its application at seven intensive care units in the city of Cali, Colombia. Methods and materials: Descriptive Cross-Sectional Study with an intentional sample of 64 professionals working in seven intensive care units and who apply MR. The self-completed survey was made up of thirteen questions, and the application period was two months. Results: Out of 64 professionals surveyed, 77.8% of them follow a protocol guide; 54.7% employes during RM the ideal Positive end-expiratory pressure (PEEP), which maintains a saturation > 90% and a PaO2 > 60 mmHg; 42.1% tolerates airway pressures between 35 and 50 cmH2O; 48.4% perform RM with a progressive increase of the PEEP and a low tidal volume. Conclusions: Regarding the knowledge related to RM, heterogeneity was found in the answers. There is currently no consensus about which is the most effective and secure way to implement an MR. This study can be the starting point to create awareness towards the revision of knowledge, capacities and abilities that are required to perform RM.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

El sistema respiratorio, es uno de los principales sistemas de soporte vital del cuerpo. Aquí se explican los pulmones, cómo funcionan, y problemas respiratorios. Se ha mantenido el detalle anatómico, pero también incluye un primer plano desde el punto de vista médico con fotografías en color. Se hace énfasis en la educación para la salud y la importancia de cuidar nuestro cuerpo.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Los pequeños pueden aprender las complejidades del sistema respiratorio no sólo de una manera informativa, sino también con experimentos sencillos, que muestran cómo es y cómo funciona realmente. Para averiguar la razón del estornudo, la tos y el hipo, las alergias y el cáncer de pulmón.