891 resultados para Blood sugar self monitoring
Resumo:
AIM: In type 1 diabetic patients (T1DM), nocturnal hypoglycaemias (NH) are a serious complication of T1DM treatment; self-monitoring of blood glucose (SMBG) is recommended to detect them. However, the majority of NH remains undetected on an occasional SMBG done during the night. An alternative strategy is the Continuous glucose monitoring (CGMS), which retrospectively shows the glycaemic profile. The aims of this retrospective study were to evaluate the true incidence of NH in T1DM, the best SMBG time to predict NH, the relationship between morning hyperglycaemia and NH (Somogyi phenomenon) and the utility of CGMS to reduce NH. METHODS: Eighty-eight T1DM who underwent a CGMS exam were included. Indications for CGMS evaluation, hypoglycaemias and correlation with morning hyperglycaemias were recorded. The efficiency of CGMS to reduce the suspected NH was evaluated after 6-9 months. RESULTS: The prevalence of NH was 67% (32% of them unsuspected). A measured hypoglycaemia at bedtime (22-24 h) had a sensitivity of 37% to detect NH (OR=2.37, P=0.001), while a single measure < or =4 mmol/l at 3-hour had a sensitivity of 43% (OR=4.60, P<0.001). NH were not associated with morning hyperglycaemias but with morning hypoglycaemias (OR=3.95, P<0.001). After 6-9 months, suspicions of NH decreased from 60 to 14% (P<0.001). CONCLUSION: NH were highly prevalent and often undetected. SMBG at bedtime, which detected hypoglycaemia had sensitivity almost equal to that of 3-hour and should be preferred because it is easier to perform. Somogyi phenomenon was not observed. CGMS is useful to reduce the risk of NH in 75% of patients.
Resumo:
Rapport de synthèse : Hypoglycémies nocturnes chez les patients diabétiques de type 1 : que pouvons-nous apprendre de la mesure de la glycémie en continu ? But : les hypoglycémies nocturnes sont une complication majeure du traitement des patients diabétiques de type 1; des autocontrôles de la glycémie capillaire sont donc recommandés pour les détecter. Cependant, la majorité des hypoglycémies nocturnes ne sont pas décelées par un autocontrôle glycémique durant la nuit. La mesure de la glycémie en continu (CGMS) est une alternative intéressante. Les buts de cette étude rétrospective étaient d'évaluer la véritable incidence des hypoglycémies nocturnes chez des patients diabétiques de type 1, la meilleure période pour effectuer un autocontrôle permettant de prédire une hypoglycémie nocturne, la relation entre les hyperglycémies matinales et les hypoglycémies nocturnes (phénomène de Somogyi) ainsi que l'utilité du CGMS pour réduire les hypoglycémies nocturnes. Méthode : quatre-vingt-huit patients diabétiques de type 1 qui avaient bénéficié d'un CGMS ont été inclus. Les indications au CGMS, les hypoglycémies nocturnes et diurnes ainsi que la corrélation entre les hypoglycémies nocturnes et les hyperglycémies matinales durant le CGMS ont été enregistrées. L'efficacité du CGMS pour réduire les hypoglycémies nocturnes a été évaluée six à neuf mois après. Résultats : la prévalence des hypoglycémies nocturnes était de 67% (32% non suspectées). La sensibilité d'une hypoglycémie à prédire une hypoglycémie nocturne était de 37% (OR = 2,37, P = 0,001) lorsqu'elle survient au coucher (22-24 h) et de 43% lorsqu'elle survient à 3 h (OR = 4,60, P < 0,001). Les hypoglycémies nocturnes n'étaient pas associées à des hyperglycémies matinales, mais à des hypoglycémies matinales (OR = 3.95, P < 0.001). Six à neuf mois après le CGMS, les suspicions cliniques d'hypoglycémies nocturnes ont diminué de 60% à 14% (P < 0.001). Abstract : Aim. - In type 1 diabetic patients (TIDM), nocturnal hypoglycaemias (Nlï) are a serious complication of T1DM treatment; self-monitoring of blood glucose (SMBG) is recommended to detect them. However, the majority of NH remains undetected on an occasional SMBG done during the night. An alternative strategy is the Continuous glucose monitoring (CGMS), which retrospectively shows the glycaemic profile. The aims of this retrospective study were to evaluate the true incidence of NH in TiDM, the bèst SMBG time to predict NH, the relationship between morning hyperglycaemia and N$ (Somogyi phenomenon) and the utility of CGMS to reduce NH. Methods. -Eighty-eight T1DM who underwent a CGMS exam were included. Indications for CGMS evaluarion, hypoglycaemias and correlation with morning hyperglycaemias were recorded. The efficiency of CGMS to reduce the suspected NH was evaluated after 6-9 months. Results. -The prevalence of NH was 67% (32% of them unsuspected). A measured hypoglycaemia at bedtime (22-24 h) had a sensitivity of 37% to detect NH (OR = 2.37, P = 0.001), while a single measure <_ 4 mmol/l at 3-hour had a sensitivity of 43% (OR = 4.60, P < 0.001). NH were not associated with morning hyperglycaemias but with morning hypoglycaemias (OR = 3.95, P < 0.001). After 6-9 months, suspicions of NH decreased from 60 to 14% (P < 0.001). Conclusion. - NH were highly prevalent and often undetected. SMBG at bedtime, which detected hypoglycaemia had sensitivity almost equal to that of 3-hour and should be preferred because it is easier to perform. Somogyi phenomenon was not observed. CGMS is useful to reduce the risk of NH in 75% of patients.
Resumo:
The purpose of this study was to examine the influence of family support on diabetes education behavioural outcomes, specifically in relation to diet, exercise, and blood glucose monitoring in adult individuals with Type 2 diabetes. Fifty-three individuals attending diabetes education for the first time were followed approximately 1 month. The findings for the influence of family support were mixed. Family attending diabetes class with participants had a positive influence with respect to diet. This is consistent with Carl Rogers (1969) who espouses setting a positive climate for learning and that learning new attitudes or information comes when external barriers are at a minimum. However family attending class with participants had no influence with respect to exercise or blood glucose monitoring. The family support action of encouraging with respect to diet overall did not influence healthy eating behaviours except for decreased skipped meals and scheduled snacks. In fact, in the areas of family willing to make healthy choices along with participant, the less the family was involved in encouraging, the better the participant did. Exercise on the other hand was influenced positively by family encouragement. This is consistent with Bandura's theory that enhancement of self-confidence and self-efficacy can lead to desired behaviour changes. Family encouragement however did not appear to influence blood glucose monitoring behaviours. This study has implications for practice in that diabetes education programs can encourage family to attend classes or get involved in encouraging the person with diabetes, so that it may help to increase healthy eating behaviours and exercise. As time is necessary to implement changes in behaviour, future research can look at the influence of family support over a 6-month, I-year, or greater period.
Resumo:
Bakgrund: Diabetes typ 2 är en endokrin sjukdom och är en av de största folksjukdomarna i världen. Förhöjda blodsockervärden gör att både små och stora blodkärl tar skada och detta leder till olika komplikationer såsom hjärtinfarkt, stroke och njurskador. Med hjälp av viktnedgång, kostreglering, regelbundet fysisk aktivitet och övervakning av blodglukosnivåerna kan risken för komplikationer förebyggas. Genom att förebygga komplikationer kan livskvaliteten främja patientens dagliga liv. En del av diabetesvården består av egenvårdsprogram där patienten får stöd och rådgivning att hantera sin diabetes. Syfte: Denna litteraturstudie syftar till att studera vilka faktorer i egenvårdsprogram som främjar livskvaliteten hos patienter med diabetes typ 2. Metod: Litteraturstudie, artiklarna söktes i databaserna CINAHL, PubMed och Web of Science. 14 kvantitativa artiklar inkluderades. Resultat: Resultatet visade att information, individuell målsättning och uppföljning var viktiga faktorer i egenvårdsprogrammen för att främja livskvaliteten hos patienter med diabetes typ 2. Slutsats: Att leva med diabetes typ 2 kräver noggrannhet och planering i det dagliga livet. Egenvårdsprogram kan minska risken för komplikationer där följsamhet till egenvården främjas och livskvaliteten gynnas.
Resumo:
Background: The cerebral network that is active during rest and is deactivated during goal-oriented activity is called the default mode network (DMN). It appears to be involved in self-referential mental activity. Atypical functional connectivity in the DMN has been observed in schizophrenia. One hypothesis suggests that pathologically increased DMN connectivity in schizophrenia is linked with a main symptom of psychosis, namely, misattribution of thoughts. Methods: A resting-state pseudocontinuous arterial spin labeling (ASL) study was conducted to measure absolute cerebral blood flow (CBF) in 34 schizophrenia patients and 27 healthy controls. Using independent component analysis (ICA), the DMN was extracted from ASL data. Mean CBF and DMN connectivity were compared between groups using a 2-sample t test. Results: Schizophrenia patients showed decreased mean CBF in the frontal and temporal regions (P < .001). ICA demonstrated significantly increased DMN connectivity in the precuneus (x/y/z = -16/-64/38) in patients than in controls (P < .001). CBF was not elevated in the respective regions. DMN connectivity in the precuneus was significantly correlated with the Positive and Negative Syndrome Scale scores (P < .01). Conclusions: In schizophrenia patients, the posterior hub-which is considered the strongest part of the DMN-showed increased DMN connectivity. We hypothesize that this increase hinders the deactivation of the DMN and, thus, the translation of cognitive processes from an internal to an external focus. This might explain symptoms related to defective self-monitoring, such as auditory verbal hallucinations or ego disturbances.
Resumo:
ntroduction: The ProAct study has shown that a pump switch to the Accu-Chek® Combo system (Roche Diagnostics Deutschland GmbH, Mannheim, Germany) in type 1 diabetes patients results in stable glycemic control with significant improvements in glycated hemoglobin (HbA1c) in patients with unsatisfactory baseline HbA1c and shorter pump usage time. Patients and Methods: In this post hoc analysis of the ProAct database, we investigated the glycemic control and glycemic variability at baseline by determination of several established parameters and scores (HbA1c, hypoglycemia frequency, J-score, Hypoglycemia and Hyperglycemia Indexes, and Index of Glycemic Control) in participants with different daily bolus and blood glucose measurement frequencies (less than four day, four or five per day, and more than five per day, in both cases). The data were derived from up to 299 patients (172 females, 127 males; age [mean±SD], 39.4±15.2 years; pump treatment duration, 7.0±5.2 years). Results: Participants with frequent glucose readings had better glycemic control than those with few readings (more than five readings per day vs. less than four readings per day: HbA1c, 7.2±1.1% vs. 8.0±0.9%; mean daily blood glucose, 151±22 mg/dL vs. 176±30 mg/dL; percentage of readings per month >300 mg/dL, 10±4% vs. 14±5%; percentage of readings in target range [80-180 mg/dL], 59% vs. 48% [P<0.05 in all cases]) and had a lower glycemic variability (J-score, 49±13 vs. 71±25 [P<0.05]; Hyperglycemia Index, 0.9±0.5 vs. 1.9±1.2 [P<0.05]; Index of Glycemic Control, 1.9±0.8 vs. 3.1±1.6 [P<0.05]; Hypoglycemia Index, 0.9±0.8 vs. 1.2±1.3 [not significant]). Frequent self-monitoring of blood glucose was associated with a higher number of bolus applications (6.1±2.2 boluses/day vs. 4.5±2.0 boluses/day [P<0.05]). Therefore, a similar but less pronounced effect on glycemic variability in favor of more daily bolus applications was observed (more than five vs. less than four bolues per day: J-score, 57±17 vs. 63±25 [not significant]; Hypoglycemia Index, 1.0±1.0 vs. 1.5±1.4 [P<0.05]; Hyperglycemia Index, 1.3±0.6 vs. 1.6±1.1 [not significant]; Index of Glycemic Control, 2.3±1.1 vs. 3.1±1.7 [P<0.05]). Conclusions: Pump users who perform frequent daily glucose readings have a better glycemic control with lower glycemic variability.
Resumo:
This study (1) established comedogenicity dose response curves for the pure compounds of 3,3$\sp\prime$,4,4$\sp\prime$-tetrachloroazobenzene (TCAB) and 3,3$\sp\prime$,4,4$\sp\prime$-tetrachloroazoxybenzene (TCAOB) individually and as a couple-compound using a rabbit ear model; (2) used a rabbit ear model to establish comedogenicity potential for TCAB and TCAOB as they existed in a given industrial herbicide manufacture process; (3) evaluated actual environmental contamination in a herbicide industrial setting by air monitoring and wipe sampling; (4) biologically monitored potentially exposed workers for alterations in follicular orifice size as an index of actual exposure to chloracnegenic compounds; and (5) biologically monitored potentially exposed workers for changes in weight, cholesterol, triglycerides and blood sugar.^ A silastic monomer mold (an objective measure) was used to measure change in follicular orifice size over time. This required taking impressions of (1) skin of the forehead and right and left malar crescents of workers and (2) the skin of the external ear of the rabbit. Molds were stained using a solution of hematoxylin and digitized using a Nikon UFX microscope (magnification 300 X), a drawing tube and a digitizing tablet attached to an IBM Personal Computer. Comedogenicity assays were used to establish dose-response curves for TCAB, TCAOB and the couple-compound TCAB + TCAOB.^ No evidence of chloracne or toxicity was observed in any of the workers. Nor, was there a statistically significant increase in size of follicular orifice means measured over time. This was attributed to extensive personal and environmental hygiene programs along with teaching the workers about chloracne, its cause and its prevention. These programs may have been the greatest factor in preventing the development of chloracne in this group of workers. Monitoring of the plant environment showed relatively high concentrations of the couple-compound (TCAB + TCAOB). Comedogenicity assays showed a linear dose-response relationship over time for TCAB, TCAOB and the couple-compound. An antagonistic action was found for the TCAB/TCAOB of the couple-compound; such action may provide some protection to workers in this type of setting. It is speculated that the observed antagonistic action may be due to the difference in binding affinities of TCAB/TCAOB for receptor sites. ^
Resumo:
— In 2000, according to the World Health Organization, at least 171 million people, 2.8% of the population worldwide, suffered from diabetes. The Centres for Disease Control has defined it as an epidemic disease. Its incidence is increasing rapidly, and it is estimated that by 2030 this number will almost double. Diabetes mellitus occurs throughout the world, but is more common (especially type 2) in the more developed countries. Diabetes is a chronic condition that occurs when pancreas does not assure enough insulin secretion or when the body does not consume the insulin produced. Insulin is a hormone that regulates blood sugar. The effect of uncontrolled diabetes is the hyperglycaemia (blood sugar), which eventually seriously damage many organs and systems, especially the nerves and blood vessels. Diabetes type 2 (most common type of diabetes) is highly correlated with elderly people, obesity or overweight. Promoting a healthy lifestyle helps patients to improve their quality of life and in many cases to avoid complications related to the disease. This paper is intended to describe an iPhone-based application for self-management of type 2 diabetic patients, which allow them improving their lifestyle through healthy diet, physical activity and education
Resumo:
In recent years a set of production paradigms were proposed in order to capacitate manufacturers to meet the new market requirements, such as the shift in demand for highly customized products resulting in a shorter product life cycle, rather than the traditional mass production standardized consumables. These new paradigms advocate solutions capable of facing these requirements, empowering manufacturing systems with a high capacity to adapt along with elevated flexibility and robustness in order to deal with disturbances, like unexpected orders or malfunctions. Evolvable Production Systems propose a solution based on the usage of modularity and self-organization with a fine granularity level, supporting pluggability and in this way allowing companies to add and/or remove components during execution without any extra re-programming effort. However, current monitoring software was not designed to fully support these characteristics, being commonly based on centralized SCADA systems, incapable of re-adapting during execution to the unexpected plugging/unplugging of devices nor changes in the entire system’s topology. Considering these aspects, the work developed for this thesis encompasses a fully distributed agent-based architecture, capable of performing knowledge extraction at different levels of abstraction without sacrificing the capacity to add and/or remove monitoring entities, responsible for data extraction and analysis, during runtime.
Resumo:
Introduction of technologies in the workplace have led to a dramatic change. These changes have come with an increased capacity to gather data about one’s working performance (i.e. productivity), as well as the capacity to track one’s personal responses (i.e. emotional, physiological, etc.) to this changing workplace environment. This movement of self-monitoring or self-sensing using diverse types of wearable sensors combined with the use of computing has been identified as the Quantified-Self. Miniaturization of sensors, reduction in cost and a non-stop increase in the computer power capacity has led to a panacea of wearables and sensors to track and analyze all types of information. Utilized in the personal sphere to track information, a looming question remains, should employers use the information from the Quantified-Self to track their employees’ performance or well-being in the workplace and will this benefit employees? The aim of the present work is to layout the implications and challenges associated with the use of Quantified-Self information in the workplace. The Quantified-Self movement has enabled people to understand their personal life better by tracking multiple information and signals; such an approach could allow companies to gather knowledge on what drives productivity for their business and/or well-being of their employees. A discussion about the implications of this approach will cover 1) Monitoring health and well-being, 2) Oversight and safety, and 3) Mentoring and training. Challenges will address the question of 1) Privacy and Acceptability, 2) Scalability and 3) Creativity. Even though many questions remain regarding their use in the workplace, wearable technologies and Quantified-Self data in the workplace represent an exciting opportunity for the industry and health and safety practitioners who will be using them.
Resumo:
Ambulatory blood pressure (BP) monitoring has become useful in the diagnosis and management of hypertensive individuals. In addition to 24-hour values, the circadian variation of BP adds prognostic significance in predicting cardiovascular outcome. However, the magnitude of circadian BP patterns in large studies has hardly been noticed. Our aims were to determine the prevalence of circadian BP patterns and to assess clinical conditions associated with the nondipping status in groups of both treated and untreated hypertensive subjects, studied separately. Clinical data and 24-hour ambulatory BP monitoring were obtained from 42,947 hypertensive patients included in the Spanish Society of Hypertension Ambulatory Blood Pressure Monitoring Registry. They were 8384 previously untreated and 34,563 treated hypertensives. Twenty-four-hour ambulatory BP monitoring was performed with an oscillometric device (SpaceLabs 90207). A nondipping pattern was defined when nocturnal systolic BP dip was <10% of daytime systolic BP. The prevalence of nondipping was 41% in the untreated group and 53% in treated patients. In both groups, advanced age, obesity, diabetes mellitus, and overt cardiovascular or renal disease were associated with a blunted nocturnal BP decline (P<0.001). In treated patients, nondipping was associated with the use of a higher number of antihypertensive drugs but not with the time of the day at which antihypertensive drugs were administered. In conclusion, a blunted nocturnal BP dip (the nondipping pattern) is common in hypertensive patients. A clinical pattern of high cardiovascular risk is associated with nondipping, suggesting that the blunted nocturnal BP dip may be merely a marker of high cardiovascular risk.
Resumo:
The aim of this report is to address the benefits of the minimal invasive venous drainage in a pediatric cardio surgical scenario. Juvenile bovine experiments (67.4+/-11 kg) were performed. The right atrium was cannulated in a trans-jugular way by using the self-expandable (Smart Stat, 12/20F, 430 mm) venous cannula (Smartcannula LLC, Lausanne, Switzerland) vs. a 14F 250 mm (Polystan Lighthouse) standard pediatric venous cannula. Establishing the cardiopulmonary bypass (CPB), the blood flows were assessed for 20 mmHg, 30 mmHg and 40 mmHg of driving pressure. Venous drainage (flow in l/min) at 20 mmHg, 30 mmHg, and 40 mmHg drainage load was 0.26+/-0.1, 0.35+/-0.2 and 0.28+/-0.08 for the 14F standard vs. 1.31+/-0.22, 1.35+/-0.24 and 1.9+/-0.2 for the Smart Stat 12/20F cannula. The 43 cm self-expanding 12/20F Smartcannula outperforms the 14F standard cannula. The results described herein allow us to conclude that usage of the self-expanding Smartcannula also in the pediatric patients improves the flow and the drainage capacity, avoiding the insufficient and excessive drainage. We believe that similar results may be expected in the clinical settings.
Resumo:
We present a cross-sectional study that aims to describe the sociodemographic and clinical conditions of individuals with diabetes mellitus and to analyze their knowledge of treatment five years after the end of an educational program in which they took part. In 2010, 40 individuals who had participated in a diabetes educational program for 12 months in 2005 at a primary care service were interviewed. A form was used for data collection that included their knowledge of the notion, physiopathology, and treatment of the disease; exercise; nutrition; foot care; self-monitoring of capillary blood glucose at home; hypoglycemia; chronic complications; special situations; and family support. The results showed that the volunteers incorporated the information about the notion, physiopathology, and treatment of the disease; exercise; foot care; self-monitoring; care associated with hypoglycemia; chronic complications; and special situations. In contrast, nutrition and family support require further reinforcement. It is concluded that five years after the end of the educational program, the participants kept most of the information provided.
Resumo:
Ambulatory blood pressure (BP) monitoring is increasingly used in the evaluation of hypertensive patients. The ability to monitor BP throughout the day and night allows the detection of abnormal nocturnal BP patterns, the most common being a "nondipping" pattern, which is associated with increased cardiovascular risk; its correction appears to have a positive impact on cardiovascular outcome. Antihypertensive treatment should be individually adjusted to control BP during both daytime and nighttime. However, drug-induced lowering of nocturnal BP, if excessive, could amplify the morning BP surge in patients with daytime BP elevation, increasing the risk of developing a cardiovascular event. Ambulatory BP monitoring therefore represents a unique tool to establish the most appropriate antihypertensive drug regimen for the individual patient.
Resumo:
This paper presents a control strategy for blood glucose(BG) level regulation in type 1 diabetic patients. To design the controller, model-based predictive control scheme has been applied to a newly developed diabetic patient model. The controller is provided with a feedforward loop to improve meal compensation, a gain-scheduling scheme to account for different BG levels, and an asymmetric cost function to reduce hypoglycemic risk. A simulation environment that has been approved for testing of artificial pancreas control algorithms has been used to test thecontroller. The simulation results show a good controller performance in fasting conditions and meal disturbance rejection, and robustness against model–patient mismatch and errors in mealestimation