938 resultados para Below-Knee Amputee


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Semiquantitative assessment of the knee by expert magnetic resonance imaging readers is a powerful research tool for understanding the natural history of osteoarthritis (OA). Several reliable semiquantitative scoring systems have been applied to large observational cross-sectional and longitudinal epidemiologic studies and interventional clinical trials. Such evaluations have enabled understanding of the relevance of disease in structures within the knee joint to explain pain and progression of OA. Compositional imaging of cartilage has added to our ability to detect early degeneration before morphologic changes are present, which may help to prevent the permanent morphologic changes commonly seen in knee OA.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objectives To introduce a comprehensive and reliable scoring system for the assessment of whole-knee joint synovitis based on contrast-enhanced (CE) MRI. Methods Multicenter Osteoarthritis Study (MOST) is a cohort study of people with, or at high risk of, knee osteoarthritis (OA). Subjects are an unselected subset of MOST who volunteered for CE-MRI. Synovitis was assessed at 11 sites of the joint. Synovial thickness was scored semiquantitatively: grade 0 (< 2 mm), grade 1 (2-4 mm) and grade 2 (> 4 mm) at each site. Two musculoskeletal radiologists performed the readings and inter-and intrareader reliability was evaluated. Whole-knee synovitis was assessed by summing the scores from all sites. The association of Western Ontario and McMaster Osteoarthritis Index pain score with this summed score and with the maximum synovitis grade for each site was assessed. Results 400 subjects were included (mean age 58.8 +/- 7.0 years, body mass index 29.5 +/- 4.9 kg/m(2), 46% women). For individual sites, intrareader reliability (weighted kappa) was 0.67-1.00 for reader 1 and 0.60-1.00 for reader 2. Inter-reader agreement (kappa) was 0.67-0.92. For the summed synovitis scores, intrareader reliability (intraclass correlation coefficient (ICC)) was 0.98 and 0.96 for each reader and inter-reader agreement (ICC) was 0.94. Moderate to severe synovitis in the parapatellar subregion was associated with the higher maximum pain score (adjusted OR (95% CI), 2.8 (1.4 to 5.4) and 3.1 (1.2 to 7.9), respectively). Conclusions A comprehensive semiquantitative scoring system for the assessment of whole-knee synovitis is proposed. It is reliable and identifies knees with pain, and thus is a potentially powerful tool for synovitis assessment in epidemiological OA studies.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Magnetic resonance (MR) imaging is the most important imaging modality for the evaluation of traumatic or degenerative cartilaginous lesions in the knee. It is a powerful noninvasive tool for detecting such lesions and monitoring the effects of pharmacologic and surgical therapy. The specific MR imaging techniques used for these purposes can be divided into two broad categories according to their usefulness for morphologic or compositional evaluation. To assess the structure of knee cartilage, standard spin-echo (SE) and gradient-recalled echo (GRE) sequences, fast SE sequences, and three-dimensional SE and GRE sequences are available. These techniques allow the detection of morphologic defects in the articular cartilage of the knee and are commonly used in research for semiquantitative and quantitative assessments of cartilage. To evaluate the collagen network and proteoglycan content in the knee cartilage matrix, compositional assessment techniques such as T2 mapping, delayed gadolinium-enhanced MR imaging of cartilage (or dGEMRIC), T1 rho imaging, sodium imaging, and diffusion-weighted imaging are available. These techniques may be used in various combinations and at various magnetic field strengths in clinical and research settings to improve the characterization of changes in cartilage. (C)RSNA, 2011 , radiographics.rsna.org

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: To assess the association of prevalent bone marrow edema-like lesions (BMLs) and full-thickness cartilage loss with incident subchondral cyst-like lesions (SCs) in the knee to evaluate the bone contusion versus synovial fluid intrusion theories of SC formation. Materials and Methods: The Multicenter Osteoarthritis study is a longitudinal study of individuals who have or are at risk for knee osteoarthritis. The HIPAA-compliant protocol was approved by the institutional review boards of all participating centers, and written informed consent was obtained from all participants. Magnetic resonance images were acquired at baseline and 30-month follow-up and read semiquantitatively by using the Whole-Organ Magnetic Resonance Imaging Score system. The tibiofemoral and patellofemoral joints were subdivided into 14 subregions. BMLs and SCs were scored from 0 to 3. Cartilage morphology was scored from 0 to 6. The association of prevalent BMLs and full-thickness cartilage loss with incident SCs in the same subregion was assessed by using logistic regression with mutual adjustment for both predictors. Results: A total of 1283 knees were included. After adjustment for full-thickness cartilage loss, prevalent BMLs showed a strong and significant association with incident SCs in the same subregion, with an odds ratio of 12.9 (95% confidence interval [CI]: 8.9, 18.6). After adjustment for BMLs, prevalent full-thickness cartilage loss showed a significant but much less important association with incident SCs in the same subregion (odds ratio, 1.4; 95% CI: 1.0, 2.0). There was no apparent relationship between severity of full-thickness cartilage loss at baseline and incident SCs. Conclusion: Prevalent BMLs strongly predict incident SCs in the same subregion, even after adjustment for full-thickness cartilage loss, which supports the bone contusion theory of SC formation. (C) RSNA, 2010

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: To determine the relationships between eccentric hip and knee torques, symptom severity and functional capacity in females with patellofemoral pain syndrome (PFPS). Design: Within-subject correlational study. Setting: University biomechanics laboratory. Participants: 10 females diagnosed with PFPS. Main outcome measures: Eccentric strength of the hip abductors and lateral rotators, and knee extensors were assessed using an isokinetic dynamometer. A 10-cm visual analog scale was used to determine usual knee pain in the last week. The Anterior Knee Pain Scale (AKPS) was used to determine the functional capacity of the patients. Results: The study found that the greater the eccentric knee extensor and hip lateral rotator torques, the higher the functional capacity of the patients (p = 0.02, r = 0.72; p = 0.02, r = 0.72). It was also shown that the greater hip lateral rotator torque, the less the usual pain reported in the last week (p = 0.004, r = -0.84). Despite the lack of statistical significance (p = 0.11), it was also found a modest negative relationship between the eccentric knee extensor torque and the usual pain reported in the last week (r = -0.56) that was considered clinically meaningful (d = 1.4). Conclusions: This study showed that eccentric knee extensor and hip lateral rotator torques were associated with functional capacity and pain level in females with PFPS. Further investigations should be carried out to verify the effects of an intervention program focused on the eccentric action of these muscles with respect to the symptoms in patients with PFPS. (C) 2011 Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Knee joint-position sensitivity has been shown to decline with increasing age, with much of the research reported in the literature investigating this age effect in non-weight-bearing (NWB) conditions. However, little data is available in the more functional position of weight-bearing conditions. The objective of this study was to identify the influence of age on the accuracy and nature of knee joint-position sense (JPS) in both full weight-bearing (FWB) and partial weight-bearing (PWB) conditions and to determine the effect of lower-extremity dominance on knee JPS. Sixty healthy subjects from three age groups (young: 20-35 years old, middle-aged: 40-55 years, and older: 60-75 years) were assessed. Tests were conducted on both the right and left legs to examine the ability of subjects to correctly reproduce knee angles in an active criterion-active repositioning paradigm. Knee angles were measured in degrees using an electromagnetic tracking device, Polhemus 3Space Fastrak, that detected positions of sensors placed on the test limb. Errors in FWB knee joint repositioning did not increase with age, but significant age-related increases in knee joint-repositioning error were found in PWB. It was found that elderly subjects tended to overshoot the criterion angle more often than subjects from the young and middle-aged groups. Subjects in all three age groups performed better in FWB than in PWB. Differences between the stance-dominant (STD) and skill-dominant (SKD) legs did not reach significance. Results demonstrated that for, normal pain-free individuals, there is no age-related decline in knee JPS in FWB, although an age effect does exist in PWB. This outcome challenges the current view that a generalised decline in knee joint proprioception occurs with age. In addition, lower-limb dominance is not a factor in acuity of knee JPS.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: First, to assess the clinical effectiveness of hylan G-F 20 in an appropriate care treatment regimen (as defined by the American College of Rheumatology (ACR) 1995 guidelines) as measured by validated disease-specific outcomes and health-related quality of life endpoints for patients with osteoarthritis (OA) of the knee. Second, to utilize the measures of effectiveness and costs in an economic evaluation (see accompanying manuscript). Design: A total of 255 patients with OA of the knee were enrolled by rheumatologists or orthopedic surgeons into a prospective, randomized, open-label, 1-year, multi-centred trial, conducted in Canada. Patients were randomized to 'Appropriate care with hylan G-F 20' (AC+H) or 'Appropriate care without hylan G-F 20' (AC). Data were collected at clinic visits (baseline, 12 months) and by telephone (1, 2, 4, 6, 8, 10, and 12 months). Results: The AC+H group was superior to the AC group for all primary (% reduction in mean Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC) pain scale: 38% vs 13%, P=0.0001) and secondary effectiveness outcome measures. These differences were all statistically significant and exceeded the 20% difference between groups seta priori by the investigators as the minimum clinically important difference. Health-related quality of life improvements in the AC+H group were statistically superior for the WOMAC pain, stiffness and physical function (all P

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Telemedicine promises to revolutionize medical care delivery in rural and remote areas. The ability to accurately evaluate physical impairment via the Internet is important to the possible future provision of Internet-based physiotherapy. This study evaluated the reliability and validity of assessing knee range of motion via the Internet. Two therapists evaluated knee angle on a single subject via two methods of assessment: the Internet and the traditional method (face-to-face). Nine random positions of the knee were chosen with the principal examiner performing 20 face-to-face and two sets of 20 Internet measures in each position (n=540). The secondary therapist performed Internet assessments only. The Internet connection was established at a readily available speed of 17 kbit/s. The Internet-based goniometer was found to be a valid tool for measuring both knee flexion and extension angles. It was shown to possess both high intra and inter-rater reliability. Difference average plots of the scores verified the consistency of measurement between both modes of assessment. The successful evaluation of the physical outcome measure of knee range of motion via the Internet assists the further development of Internet-based physiotherapy applications. (C) 2003 Elsevier Science Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: to investigate the relationship between knee muscle strength, balance and functional independence within the first month after stroke. Relevance: cerebral vascular disease is one of the main causes of morbidity, disability and mortality in developed countries. Problems with movement control are frequent after stroke. Lower limb weakness and impaired balance are common problems that are related with the risk of falls and are likely to interfere with the ability to perform daily life activities. Physiotherapy intervention usually starts early after stroke and addresses impairments related to movement and posture in order to improve motor recovery and restore function.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introdução – Os componentes protésicos têm um papel fundamental na eficiência energética da marcha dos indivíduos amputados. Esta é uma área de conhecimento ainda em desenvolvimento, onde a investigação desempenha um papel central. Objectivos – Comparar e analisar o efeito de dois joelhos protésicos, 3R34, monocêntrico modular, de fricção constante, com auxiliar de extensão incorporado (A) e 3R92, monocêntrico modular, com travão de fricção e controlo pneumático da fase de balanço (B) no consumo energético e eficiência da marcha. Metodologia – Um indivíduo do sexo masculino de 27 anos, com amputação transfemural longa, foi sujeito a um protocolo submáximo de avaliação da resposta ao exercício em passadeira rolante (H/P/Cosmos(R) Mercury), através de um sistema de análise de gases breath‑by‑breath (Cosmed Quark PFT Ergo). Foi efetuado o mesmo protocolo com intervalo de dois dias, primeiro utilizando o joelho A e depois o B. As variáveis analisadas foram o consumo de O2 (VO2), o equivalente metabólico (MET) e a eficiência energética da marcha (Quociente de VO2 esperado de um individuo saudável e o VO2 do individuo em estudo). O esforço percecionado foi medido com a escala RPE de Borg. Resultados – O consumo energético com o joelho A (24,2 ml O2/kg/min; 6,9 MET) foi inferior ao obtido com o joelho B (28,68 ml O2/kg/min; 8,2 MET). A eficiência energética da marcha foi mais elevada para o joelho A (43%) do que para o joelho B (39%). Conclusão – A utilização do joelho A na prótese do indivíduo em estudo resulta numa marcha de menor consumo energético e maior eficiência. No entanto, este valor poderá estar influenciado pelo curto período de adaptação ao joelho B, sendo necessários mais estudos para confirmar os resultados do estudo e a influência deste fator. ABSTRACT - Background – Prosthetic components have a crucial role in the energy efficiency of amputee’s gait. This is an area of knowledge still in development, where research plays a central role. Objective – The purpose of this case study is to compare the impact in energy consumption of two prosthetic knees, titanium single‑axis constant friction knee joint with internal extension assist, 3R34 (A) and a single‑axis pneumatic swing phase control, 3R92 (B). Methodology – The participant was a transtibial amputee, male, with 27 years old, with no other clinical or functional impairments. To measure the energy expenditure a submaximal treadmill (H/P/Cosmos(R) Mercury) exercise stress test combined with a breath‑by‑breath analysis system (Cosmed Quark PFT Ergo) was used. The same test was applied to both knees, separated by two days. The analyzed variables were O2 consumption (VO2), metabolic equivalent (MET) and gait efficiency (VO2 ratio expected from a healthy individual and the studied individual). A rate of perceived exertion (Borg’s Scale) was used. Results – The results were favorable to knee A (24.2 ml O2/kg/min; 6.9 MET, 43% efficiency) compared with knee B (28.68 ml O2/kg/min; 8.2 MET, 39% efficiency). Conclusion – In this case, a less energy consumption gait corresponds to the prosthesis with knee A. These values may be influenced by the short adaptation period with knee B, so it’s necessary to perform more studies to confirm the previous results and to understand the truly impact of correct adaptation factor to the best prosthetics components for different patients.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Ballet gestures are highly non-anatomical and physiological, leading to compensatory behaviors. The knee joint is most affected by this behavior, leading to an increase risk of injury. Our purpose is to describe the knee angular displacement in amateur dancers, during a demi-plié exercise, with emphasis on valgus mechanisms frequency. Methods: 192 demi-pliés collected in six amateur female dancers (mean age = 15.33 ± 1.37 years), were analyzed regarding sagittal and frontal plane angular displacement, with an electrogoniometer connected to a signal acquisition unit at 1000 Hz. Results: all subjects presented valgus peaks along the trials, despite the global varus tendency of the knee frontal plane behavior. A significant positive correlation between the frequency of valgus and practice time was noted. Discussion: A variable angular frontal displacement was observed, with some trials comprehending a high incidence of valgus peaks along the ascending or descending phase of the demi-plié exercise. Conclusion: the frontal knee angle behavior is variable. It may present fast peaks of valgus or an initial trend of varus/valgus that is different from the global varus trend. The analysis of the activity should be considered in the training. The practice time may be related to the observed behavior.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introdução – O efeito de êmbolo é um dos principais problemas relacionados com a eficácia de uma prótese. Uma diminuição do mesmo pode levar a uma marcha mais natural através do aumento da propriocetividade. Objetivos – Verificar se existe diferença de valores do efeito de êmbolo entre vários sistemas de suspensão para próteses transtibiais com a utilização de Liners e testar a aplicação de testes de imagiologia na análise da melhor solução protésica para um determinado indivíduo. Metodologia – Foi obtida uma radiografia da prótese em carga na posição ortostática, mantendo o peso do indivíduo igualmente distribuído pelos dois pés. Seguidamente foi realizada outra radiografia no plano sagital com o joelho com 30° de flexão, com a prótese suspensa e um peso de 5kg aplicado na extremidade distal da mesma durante 30 seg. Através destes dois exames efetuaram-se as medições do êmbolo para cada tipo de sistema de suspensão. Resultados – Dos quatro sistemas estudados apenas três apresentam valores de êmbolo, visto que um dos sistemas não criou suspensão suficiente para suportar o peso colocado na extremidade distal da prótese. Através das medições realizadas nos exames imagiológicos dos três sistemas pudemos encontrar variações de efeito de êmbolo que vão dos 47,91mm aos 72,55mm. Conclusão – Através da realização do estudo imagiológico verificaram-se diferenças a nível do efeito de êmbolo nos vários sistemas de suspensão, provando que esta é uma ferramenta viável na avaliação do mesmo. Também através da análise dos resultados ficou notório que o sistema de suspensão Vacuum Assisted Suspention System (VASS) é o que apresenta menos êmbolo.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The harmony between the stump and the prosthesis is critical to allow it to fulfill its function enabling an efficient gait. A well fitted socket, with an efficient and comfortable suspension, allows the amputee to continue their daily living activities, maintaining the stump functional, making this correlation between socket and suspension very important in the functionality of the prosthesis, mobility and overall satisfaction with the device. Of our knowledge, the quantitative correlation between all of these factors as not yet been assessed. Aim of study: Verify and confirm the process of decision-making for four different trans-tibial prostheses with suspension systems: Hypobaric(A), PIN(B), Classic Suction(C) and Vacuum Active –VASS(D) according data provided by gait efficiency (mlO2/kg/m) imagiology (pistonning) and amputee perception.