993 resultados para BIOPROSTHETIC HEART-VALVES


Relevância:

80.00% 80.00%

Publicador:

Resumo:

The mechanisms of blood vessel maturation into distinct parts of the blood vasculature such as arteries, veins, and capillaries have been the subject of intense investigation over recent years. In contrast, our knowledge of lymphatic vessel maturation is still fragmentary. In this study, we provide a molecular and morphological characterization of the major steps in the maturation of the primary lymphatic capillary plexus into collecting lymphatic vessels during development and show that forkhead transcription factor Foxc2 controls this process. We further identify transcription factor NFATc1 as a novel regulator of lymphatic development and describe a previously unsuspected link between NFATc1 and Foxc2 in the regulation of lymphatic maturation. We also provide a genome-wide map of FOXC2-binding sites in lymphatic endothelial cells, identify a novel consensus FOXC2 sequence, and show that NFATc1 physically interacts with FOXC2-binding enhancers. As damage to collecting vessels is a major cause of lymphatic dysfunction in humans, our results suggest that FOXC2 and NFATc1 are potential targets for therapeutic intervention.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

BACKGROUND: The objective of the present study was to compare current results of prosthetic valve replacement following acute infective native valve endocarditis (NVE) with that of prosthetic valve endocarditis (PVE). Prosthetic valve replacement is often necessary for acute infective endocarditis. Although valve repair and homografts have been associated with excellent outcome, homograft availability and the importance of valvular destruction often dictate prosthetic valve replacement in patients with acute bacterial endocarditis. METHODS: A retrospective analysis of the experience with prosthetic valve replacement following acute NVE and PVE between 1988 and 1998 was performed at the Montreal Heart Institute. RESULTS: Seventy-seven patients (57 men and 20 women, mean age 48 +/- 16 years) with acute infective endocarditis underwent valve replacement. Fifty patients had NVE and 27 had PVE. Four patients (8%) with NVE died within 30 days of operation and there were no hospital deaths in patients with PVE. Survival at 1, 5, and 7 years averaged 80% +/- 6%, 76% +/- 6%, and 76% +/- 6% for NVE and 70% +/- 9%, 59% +/- 10%, and 55% +/- 10% for PVE, respectively (p = 0.15). Reoperation-free survival at 1, 5, and 7 years averaged 80% +/- 6%, 76% +/- 6%, and 76% +/- 6% for NVE and 45% +/- 10%, 40% +/- 10%, and 36% +/- 9% for PVE (p = 0.003). Five-year survival for NVE averaged 75% +/- 9% following aortic valve replacement and 79% +/- 9% following mitral valve replacement. Five-year survival for PVE averaged 66% +/- 12% following aortic valve replacement and 43% +/- 19% following mitral valve replacement (p = 0.75). Nine patients underwent reoperation during follow-up: indications were prosthesis infection in 4 patients (3 mitral, 1 aortic), dehiscence of mitral prosthesis in 3, and dehiscence of aortic prosthesis in 2. CONCLUSIONS: Prosthetic valve replacement for NVE resulted in good long-term patient survival with a minimal risk of reoperation compared with patients who underwent valve replacement for PVE. In patients with PVE, those who needed reoperation had recurrent endocarditis or noninfectious periprosthetic dehiscence.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

We present the case studies of two adult patients with tetralogy of Fallot who were scheduled for surgery. After addressing the right ventricular outflow tract obstruction, the aorta was opened and the ventricular septal defect was approached in a straightforward manner as it was located just under the overriding aortic valve. The second patient presented with was a situs inversus, dextroapex Fallot. In this setting, the aortic approach simplified the repair expeditiously. After 2 years, both patients are in New York Heart Association class I, with no residual ventricular septal defect, no aortic regurgitation, and complete relief of right ventricular outflow tract obstruction.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

BACKGROUND Very few data exist on the clinical impact of permanent pacemaker implantation (PPI) after transcatheter aortic valve implantation. The objective of this study was to assess the impact of PPI after transcatheter aortic valve implantation on late outcomes in a large cohort of patients. METHODS AND RESULTS A total of 1556 consecutive patients without prior PPI undergoing transcatheter aortic valve implantation were included. Of them, 239 patients (15.4%) required a PPI within the first 30 days after transcatheter aortic valve implantation. At a mean follow-up of 22±17 months, no association was observed between the need for 30-day PPI and all-cause mortality (hazard ratio, 0.98; 95% confidence interval, 0.74-1.30; P=0.871), cardiovascular mortality (hazard ratio, 0.81; 95% confidence interval, 0.56-1.17; P=0.270), and all-cause mortality or rehospitalization for heart failure (hazard ratio, 1.00; 95% confidence interval, 0.77-1.30; P=0.980). A lower rate of unexpected (sudden or unknown) death was observed in patients with PPI (hazard ratio, 0.31; 95% confidence interval, 0.11-0.85; P=0.023). Patients with new PPI showed a poorer evolution of left ventricular ejection fraction over time (P=0.017), and new PPI was an independent predictor of left ventricular ejection fraction decrease at the 6- to 12-month follow-up (estimated coefficient, -2.26; 95% confidence interval, -4.07 to -0.44; P=0.013; R(2)=0.121). CONCLUSIONS The need for PPI was a frequent complication of transcatheter aortic valve implantation, but it was not associated with any increase in overall or cardiovascular death or rehospitalization for heart failure after a mean follow-up of ≈2 years. Indeed, 30-day PPI was a protective factor for the occurrence of unexpected (sudden or unknown) death. However, new PPI did have a negative effect on left ventricular function over time.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Dilatation of the ascending aorta (AAD) is a prevalent aortopathy that occurs frequently associated with bicuspid aortic valve (BAV), the most common human congenital cardiac malformation. The molecular mechanisms leading to AAD associated with BAV are still poorly understood. The search for differentially expressed genes in diseased tissue by quantitative real-time PCR (qPCR) is an invaluable tool to fill this gap. However, studies dedicated to identify reference genes necessary for normalization of mRNA expression in aortic tissue are scarce. In this report, we evaluate the qPCR expression of six candidate reference genes in tissue from the ascending aorta of 52 patients with a variety of clinical and demographic characteristics, normal and dilated aortas, and different morphologies of the aortic valve (normal aorta and normal valve n = 30; dilated aorta and normal valve n = 10; normal aorta and BAV n = 4; dilated aorta and BAV n = 8). The expression stability of the candidate reference genes was determined with three statistical algorithms, GeNorm, NormFinder and Bestkeeper. The expression analyses showed that the most stable genes for the three algorithms employed were CDKN1β, POLR2A and CASC3, independently of the structure of the aorta and the valve morphology. In conclusion, we propose the use of these three genes as reference genes for mRNA expression analysis in human ascending aorta. However, we suggest searching for specific reference genes when conducting qPCR experiments with new cohort of samples.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

A 49-year-old woman, without known cardiovascular risk factors. Hoarseness of voice caused by a paralysis of left vocal cord. She was admitted to hospital because of acute coronary syndrome, associated to resuscitated cardiac arrest (asystolia documented) without later neurology sequels. Physical examination was anodyne. Echocardiographic study demonstrated a compatible image with a large left sinus of Valsalva aneurysm (SVA) (Panel A) and mild aortic regurgitation. Cardiac catheterization confirmed the presence of left SVA (Panel B) that produced extrinsic compression of the left main coronary artery (Panels C and D). Repair surgery was made by means of closing the aneurysmal orifice with a patch of dacron. Intra-operatory echocardiographic control study found severe aortic regurgitation, so valvular replacement with 19 mm mechanical prosthesis and extension of the valve annulus with patch of dacron was performed, associated with bypass with safena vein graft to left coronary artery. SVA is a very infrequent cardiac anomaly, generally with silent clinical course until it ruptures. Myocardial ischaemia caused by coronary artery compression is unusual. We described the case of a patient diagnosed of left SVA, whose initial clinical manifestation was the appearance of resuscitated sudden cardiac death in the context of an acute coronary syndrome.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

OBJECTIVE To study the factors associated with choice of therapy and prognosis in octogenarians with severe symptomatic aortic stenosis (AS). STUDY DESIGN Prospective, observational, multicenter registry. Centralized follow-up included survival status and, if possible, mode of death and Katz index. SETTING Transnational registry in Spain. SUBJECTS We included 928 patients aged ≥80 years with severe symptomatic AS. INTERVENTIONS Aortic-valve replacement (AVR), transcatheter aortic-valve implantation (TAVI) or conservative therapy. MAIN OUTCOME MEASURES All-cause death. RESULTS Mean age was 84.2 ± 3.5 years, and only 49.0% were independent (Katz index A). The most frequent planned management was conservative therapy in 423 (46%) patients, followed by TAVI in 261 (28%) and AVR in 244 (26%). The main reason against recommending AVR in 684 patients was high surgical risk [322 (47.1%)], other medical motives [193 (28.2%)], patient refusal [134 (19.6%)] and family refusal in the case of incompetent patients [35 (5.1%)]. The mean time from treatment decision to AVR was 4.8 ± 4.6 months and to TAVI 2.1 ± 3.2 months, P < 0.001. During follow-up (11.2-38.9 months), 357 patients (38.5%) died. Survival rates at 6, 12, 18 and 24 months were 81.8%, 72.6%, 64.1% and 57.3%, respectively. Planned intervention, adjusted for multiple propensity score, was associated with lower mortality when compared with planned conservative treatment: TAVI Hazard ratio (HR) 0.68 (95% confidence interval [CI] 0.49-0.93; P = 0.016) and AVR HR 0.56 (95% CI 0.39-0.8; P = 0.002). CONCLUSION Octogenarians with symptomatic severe AS are frequently managed conservatively. Planned conservative management is associated with a poor prognosis.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The expression of Staphylococcus aureus adhesins in Lactococcus lactis identified clumping factor A (ClfA) and fibronectin-binding protein A (FnBPA) as critical for valve colonization in rats with experimental endocarditis. This study further analyzed their role in disease evolution. Infected animals were followed for 3 d. ClfA-positive lactococci successfully colonized damaged valves, but were spontaneously eradicated over 48 h. In contrast, FnBPA-positive lactococci progressively increased bacterial titers in vegetations and spleens. At imaging, ClfA-positive lactococci were restricted to the vegetations, whereas FnBPA-positive lactococci also invaded the adjacent endothelium. This reflected the capacity of FnBPA to trigger cell internalization in vitro. Because FnBPA carries both fibrinogen- and fibronectin-binding domains, we tested the role of these functionalities by deleting the fibrinogen-binding domain of FnBPA and supplementing it with the fibrinogen-binding domain of ClfA in cis or in trans. Deletion of the fibrinogen-binding domain of FnBPA did not alter fibronectin binding and cell internalization in vitro. However, it totally abrogated valve infectivity in vivo. This ability was restored in cis by inserting the fibrinogen-binding domain of ClfA into truncated FnBPA, and in trans by coexpressing full-length ClfA and truncated FnBPA on two separate plasmids. Thus, fibrinogen and fibronectin binding could cooperate for S. aureus valve colonization and endothelial invasion in vivo.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Although streptococcal and S. aureus IE share the same primary site of infection, their pathogenesis and clinical evolution present several major differences. Streptococci adhere to cardiac valves with pre-existing endothelial lesions. In contrast, S. aureus can colonize either damaged endothelium or invade physically intact endothelial cells. These interactions are mediated by multiple surface adhesins, some of which have been only partially characterized. Streptococci produce surface glucans (gtf and ftf), ECM adhesins (e.g., fibronectin-binding proteins, FimA), and platelet aggregating factors (phase I and phase II antigens, pblA, pblB, and pblT), all of which have been.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Introducción y objetivos: La endocarditis infecciosa (EI) es una enfermedad grave producida por diversos gérmenes que afectan las válvulas cardiacas y el tejido endomiocárdico. El objetivo fue describir las características epidemiológicas, clínicas, ecocardiográficas y microbiológicas de la endocarditis infecciosa por Staphylococcus aureus (S. aureus) meticilino sensible y resistente de la Fundación Cardioinfantil – Instituto de Cardiología (FCI-IC) en el periodo de tiempo 2010- 2015. Métodos: Cohorte retrospectiva de casos de EI por S. aureus en la FCIIC para el período 2010-2015. Se realizó descripción de las variables generales de la población a estudio utilizando medidas de tendencia central y dispersión. Análisis de desenlaces teniendo cuenta la concentración inhibitoria mínima de vancomicina. Resultados: En el estudio se presentaron 27 casos de EI, con una mayor proporción de pacientes de sexo masculino, con hipertensión, diabetes y hemodiálisis. La fiebre fue la manifestación más frecuente seguida de fenómenos vasculares. La válvula más comprometida fue la mitral, principalmente nativa. Discusión: La presentación clínica de los pacientes con EI por S. aureus es aguda por lo que la fiebre es la principal manifestación clínica presentada, lo anterior favorece un rápido diagnóstico clínico. De las cepas de S. aureus causante de EI no se encontró gérmenes con sensibilidad intermedia ni resistente a la vancomicina según criterios establecidos por CLSI. Se encontró mayor proporción de pacientes con un valor de CMI para vancomicina mayor a 0,5μg/ml lo cual es importante dado que podemos estar enfrentándonos a cepas hetero VISA (hVISA).

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Despite the many existing crosslinking procedures, glutaraldehyde (GA) is still the method of choice used in the manufacture of bioprosthesis. The major problems with GA are: (a) uncontrolled reactivity due to the chemical complexity or GA solutions; (b) toxicity due to the release of GA from polymeric crosslinks; and (c) tissue impermeabilization due to polymeric and heterogeneous crosslinks formation, partially responsible for the undesirable calcification of the bioprosthesis. A new method of crosslinking glutaraldehyde acetals has been developed with GA in acid ethanolic solution, and after the distribution inside de matrix, GA is released to crosslinking. Concentrations of hydrochloride acid in ethanolic solutions between 0.1 and 0.001 mol/L with GA concentration between 0.1 and 1.0% were measured in an ultraviolet spectrophotometer to verify the presence of free aldehyde groups and polymeric compounds of GA. After these measurements, the solutions were used to crosslink bovine pericardium. The spectrophotometric results showed that GA was better protected in acetal forms for acid ethanolic solution with HCl at 0.003 mol/L and GA 1.0%(v/v). The shrinkage temperature results of bovine pericardium crosslinked with acetal solutions showed values near 85 C after the exposure to triethylamine vapors.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Descrevem-se os achados clínicos e patológicos da paratuberculose em uma criação intensiva de bovinos de leite no municí pio de Capela de Santana, RS. Os sinais clínicos foram observados em oito de um total de 345 bovinos, consistindo em diarréia crônica refratária aos tratamentos, emagrecimento progressivo e queda na produção de leite. As principais lesões macroscópicas, observadas nos oito animais necropsiados, incluíam intestino delgado com acentuado espessamento da parede e superfície mucosa de aspecto reticulado, semelhante às circunvoluções cerebrais, lesão essa perceptível, através da serosa. A luz intestinal estava preenchida com conteúdo fluido e de aspecto leitoso. Os vasos linfáticos do mesentério mostravam-se mais evidentes sendo que alguns tinham aspecto varicoso. Os linfonodos mesentéricos estavam aumentados de volume e, ao corte, fluía grande quantidade de líquido leitoso. Focos de mineralização foram observados na íntima das artérias, nas válvulas cardíacas e na serosa do rúmen. As principais lesões macroscópicas incluíam enterite, linfadenite e linfangite granulomatosa caracterizada por infiltrado inflamatório com macrófagos, células gigantes de Langhans que continham grande quantidade de bacilos álcool-ácido-resistentes. As lesões vasculares consistiam em degeneração e mineralização das túnicas í ntimas e média das artérias de grande calibre associada a proliferação de colágeno. Havia calcificação da serosa do rúmen atrofia hepatocelular difusa e hepatite granulomatosa multifocal. O M. avium subsp. paratuberculosis (Map) foi isolado em amostras de intestino e linfonodos de 8 vacas Holandesas (3,5%) com doença de Johne, dentre 229 amostras cultivadas provenientes de um rebanho leiteiro. Amostras inoculadas em HEYM com micobactina produziram colônias identificadas como Map, segundo as caracterí sticas fenotí picas próprias como: crescimento lento, coloração álcool-ácido-resistente (A.A.R.) e dependência a micobactina. O laboratório de Referência da OIE confirmou a amostra isolada. O M. avium subsp. paratuberculosis (Map) foi isolado em amostras de intestino e linfonodos de 8 vacas Holandesas (3,5%) com doença de Johne, dentre 229 amostras cultivadas provenientes de um rebanho leiteiro Amostras inoculadas em HEYM com micobactina produziram colônias identificadas como Map, segundo as caracterí sticas fenotí picas próprias como: crescimento lento, coloração álcool-ácido-resistente (A.A.R.) e dependência a micobactina. O laboratório de Referência da OIE confirmou a amostra isolada. Não houve isolamento do agente em 221 amostras intestinais quando processadas, após 2 anos de sua colheita. O teste de IDGA aplicado como “screening”, detectou 26 vacas (11,4%) positivas, dentre 228 animais testados e sacrificados em matadouro. O teste de ELISA adsorvido, utilizando o antí geno PPA-3 detectou 125 (39,8%) amostras positivas. O ELISA não adsorvido detectou mais 32 (10,1%) reagentes positivos, dentre os 314 bovinos testados. A prevalência da infecção causada pelo Map em 36 rebanhos leiteiros procedentes de 25 municí pios do Rio Grande do Sul foi estimada em 44,6% das 1316 amostras testadas. A infecção foi identificada em 35 (97,2%) dos 36 rebanhos testados e presentes em todos os municí pios incluí dos. A ocorrência da doença de Johne foi enfatizada, tanto a forma clí nica quanto a infecção subclí nica no Rio Grande do Sul, sugerindo a adoção de medidas de controle sejam aplicadas na proteção dos rebanhos leiteiros nacionais.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Os materiais cerâmicos são atualmente cada vez utilizados como opção na engenharia mundial. Por se tratar de materiais com alta resistência mecânica, possuem muitas aplicações em diversas áreas, como por exemplo a de mancais, a automotiva (sensores, isoladores, catalisadores, pistões, válvulas, revestimentos), a de implantes biocompatíveis (dentário, substituição óssea, válvulas cardíacas), a de produtos sujeitos ao desgaste (guias), a de refratários (revestimento de equipamento bélico, componentes de fornos), a eletrônica, e outras. Nos processos de fabricação da cerâmica há uma gama de fatores que contribuem para as características do produto final. Devido a isso, muitos pesquisadores têm trabalhado no estudo da influência de determinados defeitos e técnicas de produção de cerâmicas nas características do produto final. Este trabalho tem como objetivo fazer uma revisão bibliográfica de recentes artigos que analisam a influência de fatores como velocidade de queima, surgimento de trincas, porosidade, fases cristalinas, e tamanho de partículas, nas propriedades mecânicas finais das cerâmicas. Pode-se concluir que é possível aperfeiçoar o processo de fabricação da cerâmica a fim de promover as melhores propriedades mecânicas possíveis, conhecendo-se fatores prejudiciais e métodos adequados para se obter o melhor produto final.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Phenolic resins when heat treated in inert atmosphere up to 1000 degreesC become glassy polymeric carbon (GPC), a chemically inert and biocompatible material useful for medical applications, such as in the manufacture of heart valves and prosthetic devices. In earlier work we have shown that ion bombardment can modify the surface of GPC, increasing its roughness. The enhanced roughness, which depends on the species, energy and fluence of the ion beam, can improve the biocompatibility of GPC prosthetic artifacts. In this work, ion bombardment was used to make a layer of implanted ions under the surface to avoid the propagation of microcracks in regions where cardiac valves should have pins for fixation of the leaflets. GPC samples prepared at 700 and 1500 degreesC were bombarded with ions of silicon. carbon, oxygen and gold at energies of 5, 6, 8 and 10 MeV, respectively, and fluences between 1.0 x 10(13) and 1.0 x 10(16) ions/cm(2). Nanoindentation hardness characterization was used to compare bombarded with non-bombarded samples prepared at temperatures up to 2500 degreesC. The results with samples not bombarded showed that the hardness of GPC increases strongly with the heat treatment temperature. Comparison with ion bombarded samples shows that the hardness changes according to the ion used, the energy and fluence. (C) 2002 Elsevier B.V. B.V. All rights reserved.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The poly(furfuryl alcohol) is highly indicated to obtain advanced carbonaceous materials due mainly to its good carbon yield (around 50%) and a controllable cure reaction. In the processing of some carbonaceous materials, such as monolithic vitreous carbon, it is necessary to make sure that the material has the smallest porosity to be used in nobler applications such as heart valves and aerospace integrated systems. In this manuscript, a design of experiments was used to study the influence of viscosity, pH, and moisture in the porosity of the cured material. This study shows that the moisture exerts a significant influence on the porosity and the trend of the results lead to conclude that lower viscosity and moisture, and the use of non-neutralized poly(furfuryl alcohol) resins lead to obtain materials with better quality. © 2012 Wiley Periodicals, Inc.