746 resultados para BARE


Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVES: This study was designed to compare the long-term clinical outcome of coronary artery bypass grafting (CABG) with intracoronary stenting of patients with isolated proximal left anterior descending coronary artery. BACKGROUND: Although numerous trials have compared coronary angioplasty with bypass surgery, none assessed the clinical evaluation in the long term. METHODS: We evaluated the 10-year clinical outcome in the SIMA (Stent versus Internal Mammary Artery grafting) trial. Patients were randomly assigned to stent implantation versus CABG. RESULTS: Of 123 randomized patients, 59 underwent CABG and 62 received a stent (2 patients were excluded). Follow-up after 10 years was obtained for 98% of the randomized patients. Twenty-six patients (42%) in the percutaneous coronary intervention group and 10 patients (17%) in the CABG group reached an end point (p < 0.001). This difference was due to a higher need for additional revascularization. The incidences of death and myocardial infarction were identical at 10%. Progression of the disease requiring additional revascularization was rare (5%) and was similar for the 2 groups. Stent thrombosis occurred in 2 patients (3%). Angina functional class showed no significant differences between the 2 groups. CONCLUSIONS: Both stent implantation and CABG are safe and highly effective in relieving symptoms in patients with isolated, proximal left anterior descending coronary artery stenosis. Stenting with bare-metal stents is associated with a higher need for repeat interventions. The long-term prognosis for these patients is excellent with either mode of revascularization.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Based on a subgroup analysis of 18-month BAsel Stent Kosten Effektivitäts Trial (BASKET) outcome data, we hypothesized that very late (> 12 months) stent thrombosis occurs predominantly after drug-eluting stent implantation in large native coronary vessel stenting. METHODS: To prove or refute this hypothesis, we set up an 11-center 4-country prospective trial of 2260 consecutive patients treated with > or = 3.0-mm stents only, randomized to receive Cypher (Johnson ; Johnson, Miami Lakes, FL), Vision (Abbott Vascular, Abbott Laboratories, IL), or Xience stents (Abbott Vascular). Only patients with left main or bypass graft disease, in-stent restenosis or stent thrombosis, in need of nonheart surgery, at increased bleeding risk, without compliance/consent are excluded. All patients are treated with dual antiplatelet therapy for 12 months. The primary end point will be cardiac death/nonfatal myocardial infarction after 24 months with further follow-up up to 5 years. RESULTS: By June 12, 229 patients (10% of the planned total) were included with a baseline risk similar to that of the same subgroup of BASKET (n = 588). CONCLUSIONS: This study will answer several important questions of contemporary stent use in patients with large native vessel stenting. The 2-year death/myocardial infarction-as well as target vessel revascularization-and bleeding rates in these patients with a first- versus second-generation drug-eluting stent should demonstrate the benefit or harm of these stents compared to cobalt-chromium bare-metal stents in this relevant, low-risk group of everyday patients. In addition, a comparison with similar BASKET patients will allow to estimate the impact of 12- versus 6-month dual antiplatelet therapy on these outcomes.

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective To compare the effectiveness and safety of three types of stents (sirolimus eluting, paclitaxel eluting, and bare metal) in people with and without diabetes mellitus. Design Collaborative network meta-analysis. Data sources Electronic databases (Medline, Embase, the Cochrane Central Register of Controlled Trials), relevant websites, reference lists, conference abstracts, reviews, book chapters, and proceedings of advisory panels for the US Food and Drug Administration. Manufacturers and trialists provided additional data. Review methods Network meta-analysis with a mixed treatment comparison method to combine direct within trial comparisons between stents with indirect evidence from other trials while maintaining randomisation. Overall mortality was the primary safety end point, target lesion revascularisation the effectiveness end point. Results 35 trials in 3852 people with diabetes and 10 947 people without diabetes contributed to the analyses. Inconsistency of the network was substantial for overall mortality in people with diabetes and seemed to be related to the duration of dual antiplatelet therapy (P value for interaction 0.02). Restricting the analysis to trials with a duration of dual antiplatelet therapy of six months or more, inconsistency was reduced considerably and hazard ratios for overall mortality were near one for all comparisons in people with diabetes: sirolimus eluting stents compared with bare metal stents 0.88 (95% credibility interval 0.55 to 1.30), paclitaxel eluting stents compared with bare metal stents 0.91 (0.60 to 1.38), and sirolimus eluting stents compared with paclitaxel eluting stents 0.95 (0.63 to 1.43). In people without diabetes, hazard ratios were unaffected by the restriction. Both drug eluting stents were associated with a decrease in revascularisation rates compared with bare metal stents in people both with and without diabetes. Conclusion In trials that specified a duration of dual antiplatelet therapy of six months or more after stent implantation, drug eluting stents seemed safe and effective in people both with and without diabetes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Recently, stable markerless 6 DOF video based handtracking devices became available. These devices simultaneously track the positions and orientations of both user hands in different postures with at least 25 frames per second. Such hand-tracking allows for using the human hands as natural input devices. However, the absence of physical buttons for performing click actions and state changes poses severe challenges in designing an efficient and easy to use 3D interface on top of such a device. In particular, for coupling and decoupling a virtual object’s movements to the user’s hand (i.e. grabbing and releasing) a solution has to be found. In this paper, we introduce a novel technique for efficient two-handed grabbing and releasing objects and intuitively manipulating them in the virtual space. This technique is integrated in a novel 3D interface for virtual manipulations. A user experiment shows the superior applicability of this new technique. Last but not least, we describe how this technique can be exploited in practice to improve interaction by integrating it with RTT DeltaGen, a professional CAD/CAS visualization and editing tool.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVES This study sought to study the efficacy and safety of newer-generation drug-eluting stents (DES) compared with bare-metal stents (BMS) in an appropriately powered population of patients with ST-segment elevation myocardial infarction (STEMI). BACKGROUND Among patients with STEMI, early generation DES improved efficacy but not safety compared with BMS. Newer-generation DES, everolimus-eluting stents, and biolimus A9-eluting stents, have been shown to improve clinical outcomes compared with early generation DES. METHODS Individual patient data for 2,665 STEMI patients enrolled in 2 large-scale randomized clinical trials comparing newer-generation DES with BMS were pooled: 1,326 patients received a newer-generation DES (everolimus-eluting stent or biolimus A9-eluting stent), whereas the remaining 1,329 patients received a BMS. Random-effects models were used to assess differences between the 2 groups for the device-oriented composite endpoint of cardiac death, target-vessel reinfarction, and target-lesion revascularization and the patient-oriented composite endpoint of all-cause death, any infarction, and any revascularization at 1 year. RESULTS Newer-generation DES substantially reduce the risk of the device-oriented composite endpoint compared with BMS at 1 year (relative risk [RR]: 0.58; 95% confidence interval [CI]: 0.43 to 0.79; p = 0.0004). Similarly, the risk of the patient-oriented composite endpoint was lower with newer-generation DES than BMS (RR: 0.78; 95% CI: 0.63 to 0.96; p = 0.02). Differences in favor of newer-generation DES were driven by both a lower risk of repeat revascularization of the target lesion (RR: 0.33; 95% CI: 0.20 to 0.52; p < 0.0001) and a lower risk of target-vessel infarction (RR: 0.36; 95% CI: 0.14 to 0.92; p = 0.03). Newer-generation DES also reduced the risk of definite stent thrombosis (RR: 0.35; 95% CI: 0.16 to 0.75; p = 0.006) compared with BMS. CONCLUSIONS Among patients with STEMI, newer-generation DES improve safety and efficacy compared with BMS throughout 1 year. It remains to be determined whether the differences in favor of newer-generation DES are sustained during long-term follow-up.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND This study sought to determine whether the 1-year differences in major adverse cardiac event between a stent eluting biolimus from a biodegradable polymer and bare-metal stents (BMSs) in the COMFORTABLE trial (Comparison of Biolimus Eluted From an Erodible Stent Coating With Bare Metal Stents in Acute ST-Elevation Myocardial Infarction) were sustained during long-term follow-up. METHODS AND RESULTS A total of 1061 patients were randomly assigned to biolimus-eluting stent (BES) and BMS at 11 centers, and follow-up rates at 2 years were 96.3%. A subgroup of 103 patients underwent angiography at 13 months. At 2 years, differences in the primary end point of cardiac death, target-vessel myocardial infarction, and target lesion revascularization continued to diverge in favor of BES-treated patients (5.8%) compared with BMS-treated patients (11.9%; hazard ratio=0.48; 95% confidence interval, 0.31-0.72; P<0.001) with a significant risk reduction during the second year of follow-up (hazard ratio 1-2 years=0.45; 95% confidence interval, 0.20-1.00; P=0.049). Differences in the primary end point were driven by a reduction in target lesion revascularization (3.1% versus 8.2%; P<0.001) and target-vessel reinfarction (1.3% versus 3.4%; P=0.023). The composite of death, any reinfarction and revascularization (14.5% versus 19.3%; P=0.03), and cardiac death or target-vessel myocardial infarction (4.2% versus 7.2%; P=0.036) were less frequent among BES-treated patients compared with BMS-treated patients. The 13-month angiographic in-stent percent diameter stenosis amounted to 12.0±7.2 in BES- and 39.6±25.2 in BMS-treated lesions (P<0.001). CONCLUSIONS Among patients with ST-segment-elevation myocardial infarction undergoing primary percutaneous coronary intervention, BES continued to improve cardiovascular events compared with BMS beyond 1 year.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND In patients with cardiogenic shock, data on the comparative safety and efficacy of drug-eluting stents (DESs) vs. bare metal stents (BMSs) are lacking. We sought to assess the performance of DESs compared with BMSs among patients with cardiogenic shock undergoing percutaneous coronary intervention (PCI). METHODS Out of 236 patients with acute coronary syndromes complicated by cardiogenic shock, 203 were included in the final analysis. The primary endpoint included death, and the secondary endpoint of major adverse cardiac and cerebrovascular events (MACCEs) included the composite of death, myocardial infarction, any repeat revascularization and stroke. Patients were followed for a minimum of 30 days and up to 4 years. As stent assignment was not random, we performed a propensity score analysis to minimize potential bias. RESULTS Among patients treated with DESs, there was a lower risk of the primary and secondary endpoints compared with BMSs at 30 days (29 vs. 56%, P < 0.001; 34 vs. 58%, P = 0.001, respectively) and during long-term follow-up [hazard ratio 0.43, 95% confidence interval (CI) 0.29-0.65, P < 0.001; hazard ratio 0.49, 95% CI 0.34-0.71, P < 0.001, respectively]. After propensity score adjustment, all-cause mortality was reduced among patients treated with DESs compared with BMSs both at 30 days [adjusted odds ratio (OR) 0.26, 95% CI 0.11-0.62; P = 0.002] and during long-term follow-up (adjusted hazard ratio 0.40, 95% CI 0.22-0.72; P = 0.002). The rate of MACCE was lower among patients treated with DESs compared with those treated with BMSs at 30 days (adjusted OR 0.42, 95% CI 0.19-0.95; P = 0.036). The difference in MACCEs between devices approached significance during long-term follow-up (adjusted hazard ratio 0.60, 95% CI 0.34-1.01; P = 0.052). CONCLUSION DESs appear to be associated with improved clinical outcomes, including a reduction in all-cause mortality compared with BMSs among patients undergoing PCI for cardiogenic shock, possibly because of a pacification of the infarct-related artery by anti-inflammatory drug. The results of this observational study require confirmation in an appropriately powered randomized trial.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND Recently, it has been suggested that the type of stent used in primary percutaneous coronary interventions (pPCI) might impact upon the outcomes of patients with acute myocardial infarction (AMI). Indeed, drug-eluting stents (DES) reduce neointimal hyperplasia compared to bare-metal stents (BMS). Moreover, the later generation DES, due to its biocompatible polymer coatings and stent design, allows for greater deliverability, improved endothelial healing and therefore less restenosis and thrombus generation. However, data on the safety and performance of DES in large cohorts of AMI is still limited. AIM To compare the early outcome of DES vs. BMS in AMI patients. METHODS This was a prospective, multicentre analysis containing patients from 64 hospitals in Switzerland with AMI undergoing pPCI between 2005 and 2013. The primary endpoint was in-hospital all-cause death, whereas the secondary endpoint included a composite measure of major adverse cardiac and cerebrovascular events (MACCE) of death, reinfarction, and cerebrovascular event. RESULTS Of 20,464 patients with a primary diagnosis of AMI and enrolled to the AMIS Plus registry, 15,026 were referred for pPCI and 13,442 received stent implantation. 10,094 patients were implanted with DES and 2,260 with BMS. The overall in-hospital mortality was significantly lower in patients with DES compared to those with BMS implantation (2.6% vs. 7.1%,p < 0.001). The overall in-hospital MACCE after DES was similarly lower compared to BMS (3.5% vs. 7.6%, p < 0.001). After adjusting for all confounding covariables, DES remained an independent predictor for lower in-hospital mortality (OR 0.51,95% CI 0.40-0.67, p < 0.001). Since groups differed as regards to baseline characteristics and pharmacological treatment, we performed a propensity score matching (PSM) to limit potential biases. Even after the PSM, DES implantation remained independently associated with a reduced risk of in-hospital mortality (adjusted OR 0.54, 95% CI 0.39-0.76, p < 0.001). CONCLUSIONS In unselected patients from a nationwide, real-world cohort, we found DES, compared to BMS, was associated with lower in-hospital mortality and MACCE. The identification of optimal treatment strategies of patients with AMI needs further randomised evaluation; however, our findings suggest a potential benefit with DES.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVES This study sought to compare rates of stent thrombosis and major adverse cardiac and cerebrovascular events (MACCE) (composite of death, myocardial infarction, or stroke) after coronary stenting with drug-eluting stents (DES) versus bare-metal stents (BMS) in patients who participated in the DAPT (Dual Antiplatelet Therapy) study, an international multicenter randomized trial comparing 30 versus 12 months of dual antiplatelet therapy in subjects undergoing coronary stenting with either DES or BMS. BACKGROUND Despite antirestenotic efficacy of coronary DES compared with BMS, the relative risk of stent thrombosis and adverse cardiovascular events is unclear. Many clinicians perceive BMS to be associated with fewer adverse ischemic events and to require shorter-duration dual antiplatelet therapy than DES. METHODS Prospective propensity-matched analysis of subjects enrolled into a randomized trial of dual antiplatelet therapy duration was performed. DES- and BMS-treated subjects were propensity-score matched in a many-to-one fashion. The study design was observational for all subjects 0 to 12 months following stenting. A subset of eligible subjects without major ischemic or bleeding events were randomized at 12 months to continued thienopyridine versus placebo; all subjects were followed through 33 months. RESULTS Among 10,026 propensity-matched subjects, DES-treated subjects (n = 8,308) had a lower rate of stent thrombosis through 33 months compared with BMS-treated subjects (n = 1,718, 1.7% vs. 2.6%; weighted risk difference -1.1%, p = 0.01) and a noninferior rate of MACCE (11.4% vs. 13.2%, respectively, weighted risk difference -1.8%, p = 0.053, noninferiority p < 0.001). CONCLUSIONS DES-treated subjects have long-term rates of stent thrombosis that are lower than BMS-treated subjects. (The Dual Antiplatelet Therapy Study [DAPT study]; NCT00977938).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

IMPORTANCE Despite antirestenotic efficacy of coronary drug-eluting stents (DES) compared with bare metal stents (BMS), the relative risk of stent thrombosis and adverse cardiovascular events is unclear. Although dual antiplatelet therapy (DAPT) beyond 1 year provides ischemic event protection after DES, ischemic event risk is perceived to be less after BMS, and the appropriate duration of DAPT after BMS is unknown. OBJECTIVE To compare (1) rates of stent thrombosis and major adverse cardiac and cerebrovascular events (MACCE; composite of death, myocardial infarction, or stroke) after 30 vs 12 months of thienopyridine in patients treated with BMS taking aspirin and (2) treatment duration effect within the combined cohorts of randomized patients treated with DES or BMS as prespecified secondary analyses. DESIGN, SETTING, AND PARTICIPANTS International, multicenter, randomized, double-blinded, placebo-controlled trial comparing extended (30-months) thienopyridine vs placebo in patients taking aspirin who completed 12 months of DAPT without bleeding or ischemic events after receiving stents. The study was initiated in August 2009 with the last follow-up visit in May 2014. INTERVENTIONS Continued thienopyridine or placebo at months 12 through 30 after stent placement, in 11,648 randomized patients treated with aspirin, of whom 1687 received BMS and 9961 DES. MAIN OUTCOMES AND MEASURES Stent thrombosis, MACCE, and moderate or severe bleeding. RESULTS Among 1687 patients treated with BMS who were randomized to continued thienopyridine vs placebo, rates of stent thrombosis were 0.5% vs 1.11% (n = 4 vs 9; hazard ratio [HR], 0.49; 95% CI, 0.15-1.64; P = .24), rates of MACCE were 4.04% vs 4.69% (n = 33 vs 38; HR, 0.92; 95% CI, 0.57-1.47; P = .72), and rates of moderate/severe bleeding were 2.03% vs 0.90% (n = 16 vs 7; P = .07), respectively. Among all 11,648 randomized patients (both BMS and DES), stent thrombosis rates were 0.41% vs 1.32% (n = 23 vs 74; HR, 0.31; 95% CI, 0.19-0.50; P < .001), rates of MACCE were 4.29% vs 5.74% (n = 244 vs 323; HR, 0.73; 95% CI, 0.62-0.87; P < .001), and rates of moderate/severe bleeding were 2.45% vs 1.47% (n = 135 vs 80; P < .001). CONCLUSIONS AND RELEVANCE Among patients undergoing coronary stent placement with BMS and who tolerated 12 months of thienopyridine, continuing thienopyridine for an additional 18 months compared with placebo did not result in statistically significant differences in rates of stent thrombosis, MACCE, or moderate or severe bleeding. However, the BMS subset may have been underpowered to identify such differences, and further trials are suggested. TRIAL REGISTRATION clinicaltrials.gov Identifier: NCT00977938.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We are confident of many of the judgements we make as to what sorts of alterations the members of nature’s kinds can survive, and what sorts of events mark the ends of their existences. But is our confidence based on empirical observation of nature’s kinds and their members? Conventionalists deny that we can learn empirically which properties are essential to the members of nature’s kinds. Judgements of sameness in kind between members, and of numerical sameness of a member across time, merely project our conventions of individuation. Our confidence is warranted because apart from those conventions there are no phenomena of kind-sameness or of numerical sameness across time. There is just “stuff” displaying properties. This paper argues that conventionalists can assign no properties to the “stuff” beyond immediate phenomenal properties. Consequently they cannot explain how each of us comes to be able to wield “our conventions”.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In irrigated areas where cover crop establishment can be assured, consequent soil or nutrient conservation could increase sustainability of cropping systems. Replacing bare fallow with cover crops may increase sustainability by enhancing soil aggregate stability, water retention capacity or controlling nitrate leaching. Nevertheless, adoption of cover crops increase evapotranspiration and reduce water percolation beyond the root systems; therefore, it could lead to salt accumulation in the upper soil layers. This study was conducted during four years to determine the effect of replacing bare fallow by a cover crop on soil salt accumulation and salt leaching in an irrigated maize production system.