999 resultados para Aorte, mesure


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The goal of this paper is to provide clinicians and researchers, who may not be experts in psychometrics, with a guide for the selection and adaptation of an instrument for clinical research. Issues related to the concept to be measured, the targeted clientele, the selection criteria for the instrument (algorithm), the strategies for translation and adaptation, as well as potential bias related to the administration of an instrument are reviewed and discussed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Ce travail s'intéresse à l'accompagnement offert par des bénévoles à des personnes en fin de vie. En analysant le rôle des bénévoles dans les institutions hospitalières et para-hospitalières ainsi que leurs trajectoires, motivations ou aspirations, il s'agit de mettre en lumière les constructions symboliques et pratiques autour de la mort et des personnes mourantes. De la démarche des bénévoles, et de cet attrait pour la mort d'autrui ressort comme une position dissymétrique (entre une personne souffrante et une autre personne bienportante) qu'avant de condamner, ce travail propose d'analyser.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Comprend : [ Page de titre avec figures. Clerc enseignant (Bartholomeo Paxi?) les poids et mesures. XVIè siècle.] [ Cote : BNF B 40404. ]

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Measurement of the blood pressure by the physician remains an essential step in the evaluation of cardiovascular risk. Ambulatory measurement and self-measurement of blood pressure are ways of counteracting the "white coat" effect which is the rise in blood pressure many patients experience in the presence of doctors. Thus, it is possible to define the cardiovascular risk of hypertension and identify the patients with the greatest chance of benefiting from antihypertensive therapy. However, it must be realised that normotensive subjects during their everyday activities and becoming hypertensive in the doctor's surgery, may become hypertensive with time, irrespective of the means used to measure blood pressure. These patients should be followed up regularly even if the decision to treat has been postponed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Suite à des essais cliniques randomisés démontrant l'efficacité du dépistage de l'anévrisme de l'aorte abdominale (AAA) par échographie, plusieurs recommandations ont été publiées dans de nombreux pays en faveur du dépistage dans une partie de la population générale. De plus, au-delà de la rupture aortique, le dépistage d'un petit AAA semble être une bonne occasion d'appliquer les stratégies de prévention secondaire, permettant une amélioration globale du pronostic cardiovasculaire du patient. Ces recommandations sont cependant peu suivies; les campagnes de dépistage systématique sont rares, laissant la responsabilité du dépistage au médecin généraliste. Cet article se propose de discuter les raisons de la non-implantation du dépistage de l'AAA. [Abstract] Following the evidence of benefits of ultrasound screening for abdominal aorta aneurysms (AAA), several guidelines support this screening in population. Beyond the prompt diagnosis of AAA prior to its rupture of grim vital prognosis, small AAA can beconsidered as a prognostic marker for cardiovascular diseases (CVD). Yet, its detection is an opportunity for secondary prevention to reduce CVD mortality. Despite, these guidelines are poorly applied: systematic screening campaigns are infrequent, making the screening of family physicians responsibility. While the major benefit from this screening strategy is to reduce AAA-related death (but only trivial effect on long-term total mortality), this explains only partially the lack of guidelines implementation. The reasons of the poor implementation of these guidelines are discussed herein.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Messages à retenir: Connaître le principe des principales chirurgies du segment I de l'aorte (Tirone David, Ross, Bentall..). Le scanner MD est l'imagerie clé pour visualiser la réimplantation des coronaires natives ou un pontage associé. Le protocole scanographique le plus courant est une acquisition synchronisée en mode prospectif. Le mode rétrospectif peut être utilisé en cas de suspicion de dysfonction d'une valve mécanique. Après une TAVI, le scanner est un examen clé pour juger de la hauteur, de la circularité, de l'adossement de la prothèse et de son rapport avec les coronaires. Résumé: Les aspects post opératoires de l'aorte ascendante sont au mieux étudiés par un scanner multidétecteur injecté avec synchronisation ECG. Le mode prospectif avec bas kilovoltage est privilégié pour réduire la dose dans cette population majoritairement jeune. La communication avec l'équipe chirurgicale est importante pour l'analyse des images (le radiologue doit connaître le type de montage effectué). Parmi les gestes de cardiologie interventionnelle, la TAVI est devenue courante et les éléments de contrôle de la procédure par le scanner doivent être connus.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

By definition, obesity corresponds to the presence of a mass of fatty tissue that is excessive with respect to the body mass. Body fat can be calculated in terms of age and sex by measuring the skinfold thickness in several different places. During the MONICA project, the survey of cardiovascular risk factor prevalence enabled us to measure the thickness of four skinfolds (biceps, triceps, subscapular, suprailiac) in 263 inhabitants of Lausanne (125 men, 138 women). In men aged 25-34, 21 +/- 5% of the body mass was composed of fat, in women 29 +/- 4%. The proportion of fat increases to 31 +/- 7% in men and 41 +/- 6% in women aged 55-64. A robust regression allows body fat to be simply expressed in terms of the body mass index. This allows us to confirm the validity of this index for evaluating the degree of obesity during an epidemiological study.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fondements : La recherche sur l'oedème postopératoire consécutif à la chirurgie prothétique du genou est peu développée, notamment en raison de l'absence d'une méthode de mesure adaptée. Une collaboration entre physiothérapeutes et ingénieurs a permis de développer et valider une méthode de mesure innovante et facilement applicable. Les physiothérapeutes ont identifié un besoin clinique, les ingénieurs ont apporté leur savoir technologique, et l'équipe a conjointement élaboré le protocole de mesure et effectué l'étude de validation. Introduction : La bioimpédance est fréquemment utilisée pour évaluer l'oedème par l'analyse d'un signal électrique passant au travers du corps, en extrapolant la résistance théorique à une fréquence égale à zéro (R0). La mesure s'avère fiable et rapide, mais n'a jamais été appliquée et validée pour l'évaluation de l'oedème en chirurgie orthopédique. Objectif : L'objectif de l'étude est de valider la mesure de l'oedème du membre inférieur par bioimpédance, chez des patients ayant bénéficié d'une prothèse totale de genou (PTG). Questionnement : Après nous être assurés de l'absence d'influence de l'implant métallique de la PTG sur la mesure, nous nous questionnions sur la validité et la fiabilité des mesures de bioimpédance dans ce contexte. Méthodes : Deux évaluateurs ont mesuré à tour de rôle et à deux reprises successives l'oedème chez 24 patients opérés d'une PTG, à trois temps différents (préopératoire, J+2, J+8). L'oedème a été évalué par bioimpédance (R0) et par conversion en volume de mesures centimétriques du membre inférieur (MI). Nous avons calculé le ratio moyen des MI pour chaque méthode. Nous avons évalué la reproductibilité intra- et inter-observateurs de la bioimpédance (coefficient de corrélation intraclasse, CCI) et la corrélation entre méthodes (Spearman). Résultats : Le ratio moyen opéré/sain du volume des MI est de 1.04 (SD ± 0.06) en préopératoire, 1.18 (SD ± 0.09) à J+2 et 1.17 (SD ± 0.10) à J+8. Le ratio sain/opéré des MI de R0 est de 1.04 (SD ± 0.07) en préopératoire, 1.51 (SD ± 0.22) à J+2 et 1.65 (SD ± 0.21) à J+8. En préopératoire, à J+2 et J+8, les CCI tous supérieurs à 0.95 pour la reproductibilité intra- et inter-observateurs de la bioimpédance. La corrélation entre méthodes est de 0.71 en préopératoire, 0.61 à J2 et 0.33 à J8. Analyse et conclusion : La variation du ratio des MI entre les temps préopératoire, J+2 et J+8 est plus marquée pour R0. La mesure de bioimpédance bénéficie d'une excellente reproductibilité intra- et inter-observateurs. L'évolution dans le temps de la corrélation entre méthodes peut être expliquée par l'influence potentielle de facteurs confondants sur R0 (modification de la composition liquidienne) et par l'influence de l'atrophie musculaire postopératoire sur la mesure de volume. La collaboration physiothérapeutes-ingénieurs a permis le développement et l'évaluation d'une nouvelle méthode de mesure.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Ami, ou ennemi, le soleil ? Qui n'a jamais maudit un petit excès de bain de soleil sanctionné par une peau brûlée ? Mais en hiver, quand il se fait rare, l'huile de foie de morue est la panacée que prescrit la sagesse de nos grands-mères pour remplacer la vitamine D qu'en temps normal il nous aide à synthétiser. Pour pouvoir faire le point sur les dangers et les bénéfices du rayonnement solaire, il faut connaître son intensité et en particulier celle du rayonnement ultraviolet (UV) qui a une forte influence sur la santé.Durant ces dernières décades, une forte augmentation des cancers de la peau a été constatée dans les pays développés. La communauté médicale suppose que cette augmentation est liée à une plus forte exposition aux UV, qui serait elle-même due à des changements d'habitudes de la population (engouement pour les loisirs en plein air, pour les vacances sous les tropiques, popularité du bronzage, etc.) et éventuellement à un accroissement du rayonnement UV. [Auteurs]