901 resultados para Aorta abdominal


Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background—Abdominal aortic aneurysm (AAA) is a common cardiovascular disease among older people and demonstrates significant heritability. In contrast to similar complex diseases, relatively few genetic associations with AAA have been confirmed. We reanalysed our genome-wide study and carried through to replication suggestive discovery associations at a lower level of significance.

Methods and Results—A genome-wide association study was conducted using 1,830 cases from the UK, New Zealand and Australia with infra-renal aorta diameter =30mm or ruptured AAA and 5,435 unscreened controls from the 1958 Birth Cohort and National Blood Service cohort from the Wellcome Trust Case Control Consortium. Eight suggestive associations with P<1x10-4 were carried through to in silico replication in 1,292 AAA cases and 30,503 controls. One SNP associated with P<0.05 after Bonferroni correction in the in silico study underwent further replication (706 AAA cases and 1,063 controls from the UK, 507 AAA cases and 199 controls from Denmark and 885 AAA cases and 1,000 controls from New Zealand). Low density lipoprotein receptor (LDLR) rs6511720 A, was significantly associated overall and in three of five individual replication studies. The full study showed an association that reached genome-wide significance (odds ratio 0.76; 95% confidence interval 0.70 to 0.83; P=2.08x10-10).

Conclusions—LDLR rs6511720 is associated with abdominal aortic aneurysm. This finding is consistent with established effects of this variant on coronary artery disease. Shared aetiological pathways with other cardiovascular diseases may present novel opportunities for preventative and therapeutic strategies for AAA.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This thesis was created in Word and converted to PDF using Mac OS X 10.7.5 Quartz PDFContext.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Atherosclerosis is a chronic inflammatory process that begins in early life. Improved identification of markers of early atherosclerosis via neonatal aortic intima-media thickness (aIMT) measurement may allow the development of interventions to prevent or reduce later cardiovascular disease.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The aim of this study was to describe the morphology, morphometry and ultrastructure of segments of thoracic and abdominal aorta portions in four male and female paca (Cuniculus paca). Parts of the segments were examined by light microscopy and part by scanning electron microscopy. Thickness measurements of the tunica intima and media complex and tunica adventitia of the aorta were taken. In all animals the thickness values for the tunica intima and media complex of the cranial thoracic aorta were significantly higher (mean: 702.19 mu m) when compared to the values of other aortic segments analyzed (means: 354.18 mu m; 243.55 mu m). The layers of the vessel walls show variations in structure and thickness, presumably due to an adaptation to functionaldemand.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The intimal layer of the thoracic and abdominal aortic segments of Cebus apella monkey presented an evident inner elastic lamina. The medial layer of the thoracic aorta segment showed a basic lamellar elastic pattern having a medium average of 23.12 lamellae per analyzed cut sections, which appeared disposed circular and oblique relatively to the aortic lumen. The aortic adventitial layer, at this level, was formed mainly by collagen fibers, irregularly disposed between elastic fibers and smooth muscle cells. The aortic abdominal portion, in this monkey, at the suprarenal level presented a medium number of 19.12 elastic lamellae which showed a relatively disorganized and broken up pattern. At the infrarenal level the aortic medium layer showed a medium average of 11.75 elastic lamellae and next to the emission of the internal iliac arteries it was found only a middle average of 8.37 elastic lamellae intermingled with smooth muscle cells and collagen fibers whose concentration seemed to be increased next to the adventitial layer. The external elastic lamina was only present in the more distal aortic segment near to the emission of the internal iliac arteries.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Open surgical repair of complex abdominal aortic aneurysms requires more extensive dissection and aortic clamping above the renal or mesenteric arteries. Although results of open surgical series have shown variation, morbidity and mortality is higher compared with infrarenal aortic aneurysm repair. Potential complications include renal insufficiency, mesenteric ischemia, multisystem organ failure, and death. Although endovascular treatment with fenestrated and branched endografts might potentially decrease the risk of complications and mortality, its role is not yet defined and the technology is not widely available. Issues related to durability of the procedure and secondary interventions might limit its application to patients with higher risk or those with hostile anatomy. This article summarizes the clinical results of open surgical repair of pararenal abdominal aortic aneurysms to provide a benchmark for comparison with results of endovascular treatment, using fenestrated and branched techniques. © Annals of Vascular Surgery Inc.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Giant aortic aneurysms (transverse diameter greater than 10.0 cm) are rare and open surgery is often the treatment of choice. We report an infrarenal saccular giant aortic aneurysm (measuring 25 cm in transverse diameter), which was treated with endovascular repair, with immediate technical success. No similar report of a giant infrarenal aortic aneurysm treated with an endovascular technique was found in the literature. High-risk patients could possibly benefit from the endovascular technique. Nevertheless, patient survival remains strongly influenced by comorbidities.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVE: Autopsy determination of fatal hemorrhage as the cause of death is often a difficult diagnosis in forensic medicine. No quantitative system for accurately measuring the blood volume in a corpse has been developed. MATERIALS AND METHODS: This article describes the measurement and evaluation of the cross-sectional areas of major blood vessels, of the diameter of the right pulmonary artery, of the volumes of thoracic aorta and spleen on MDCT, and of the volumes of heart chambers on MRI in 65 autopsy-verified cases of fatal hemorrhage or no fatal hemorrhage. RESULTS: Most cases with a cause of death of "fatal hemorrhage" had collapsed vessels. The finding of a collapsed superior vena cava, main pulmonary artery, or right pulmonary artery was 100% specific for fatal hemorrhage. The mean volumes of the thoracic aorta and of each of the heart chambers and the mean cross-sectional areas of all vessels except the inferior vena cava and abdominal aorta were significantly smaller in fatal hemorrhage than in no fatal hemorrhage. CONCLUSION: For the quantitative differentiation of fatal hemorrhage from other causes of death, we propose a three-step algorithm with measurements of the diameter of the right pulmonary artery, the cross-sectional area of the main pulmonary artery, and the volume of the right atrium (specificity, 100%; sensitivity, 95%). However, this algorithm must be corroborated in a prospective study, which would eliminate the limitations of this study. Quantitative postmortem cross-sectional imaging might become a reliable objective method to assess the question of fatal hemorrhage in forensic medicine.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Arterial waves are seen as possible independent mediators of cardiovascular risks, and the wave intensity analysis (WIA) has therefore been proposed as a method for patient selection for ventricular assist device (VAD) implantation. Interpreting measured wave intensity (WI) is challenging and complexity is increased by the implantation of a VAD. The waves generated by the VAD interact with the waves generated by the native heart, and this interaction varies with changing VAD settings. Eight sheep were implanted with a pulsatile VAD (PVAD) through ventriculo-aortic cannulation. The start of PVAD ejection was synchronized to the native R-wave and delayed between 0 % - 90 % of the cardiac cycle in 10 % steps or phase shifts (PS). Pressure and velocity signals were registered, using a combined Doppler and pressure wire positioned in the abdominal aorta, and used to calculate the WI. Depending on the PS, different wave interference phenomena occurred. Maximum unloading of the left ventricle (LV) coincided with constructive interference and maximum blood flow pulsatility, and maximum loading of the LV coincided with destructive interference and minimum blood flow pulsatility. We believe, that non-invasive WIA could potentially be used clinically to assess the mechanical load of the LV, and to monitor the peripheral hemodynamics such as blood flow pulsatility and risk of intestinal bleeding.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Coral reef aorta is a rare form of calcifying atherosclerosis typically involving the supra and juxtarenal aorta. P atients classically present with refractory hypertension, intermittent claudication and abdominal angina. The treatment is either surgical via transaortic endarterectomy or through transferal endovascular stentgraft placement. Here we describe the case of a 45yearold female patient infected with human immuno deficiency virus, with resistant hypertension, lower limb and abdominal claudication, who was successfully treated with endovascular stent placement. We f urther provide a brief overview of the disease characteristics and treatment options.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

AIMS In this work, we provide novel insight into the morphology of dissecting abdominal aortic aneurysms in angiotensin II-infused mice. We demonstrate why they exhibit a large variation in shape and, unlike their human counterparts, are located suprarenally rather than infrarenally. METHODS AND RESULTS We combined synchrotron-based, ultra-high resolution ex vivo imaging (phase contrast X-Ray tomographic microscopy) with in vivo imaging (high-frequency ultrasound and contrast-enhanced micro-CT) and image-guided histology. In all mice, we observed a tear in the tunica media of the abdominal aorta near the ostium of the celiac artery. Independently we found that, unlike the gradual luminal expansion typical for human aneurysms, the outer diameter increase of angiotensin II-induced dissecting aneurysms in mice was related to one or several intramural haematomas. These were caused by ruptures of the tunica media near the ostium of small suprarenal side branches, which had never been detected by the established small animal imaging techniques. The tear near the celiac artery led to apparent luminal dilatation, while the intramural haematoma led to a dissection of the tunica adventitia on the left suprarenal side of the aorta. The number of ruptured branches was higher in those aneurysms that extended into the thoracic aorta, which explained the observed variability in aneurysm shape. CONCLUSION Our results are the first to describe apparent luminal dilatation, suprarenal branch ruptures, and intramural haematoma formation in dissecting abdominal aortic aneurysms in mice. Moreover, we validate and demonstrate the vast potential of phase contrast X-ray tomographic microscopy in cardiovascular small animal applications.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

INTRODUCTION Since the initial publication in 2000, Angiotensin II-infused mice have become one of the most popular models to study abdominal aortic aneurysm in a pre-clinical setting. We recently used phase contrast X-ray based computed tomography to demonstrate that these animals develop an apparent luminal dilatation and an intramural hematoma, both related to mural ruptures in the tunica media in the vicinity of suprarenal side branches. AIMS The aim of this narrative review was to provide an extensive overview of small animal applicable techniques that have provided relevant insight into the pathogenesis and morphology of dissecting AAA in mice, and to relate findings from these techniques to each other and to our recent PCXTM-based results. Combining insights from recent and consolidated publications we aimed to enhance our understanding of dissecting AAA morphology and anatomy. RESULTS AND CONCLUSION We analyzed in vivo and ex vivo images of aortas obtained from macroscopic anatomy, histology, high-frequency ultrasound, contrast-enhanced micro-CT, micro-MRI and PCXTM. We demonstrate how in almost all publications the aorta has been subdivided into a part in which an intact lumen lies adjacent to a remodeled wall/hematoma, and a part in which elastic lamellae are ruptured and the lumen appears to be dilated. We show how the novel paradigm fits within the existing one, and how 3D images can explain and connect previously published 2D structures. We conclude that PCXTM-based findings are in line with previous results, and all evidence points towards the fact that dissecting AAAs in Angiotensin II-infused mice are actually caused by ruptures of the tunica media in the immediate vicinity of small side branches.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVE This study aims to report the management of patients with spontaneous isolated dissection of the abdominal aorta (sIAAD). METHODS A cohort of 18 consecutive patients (12 male, mean age 58 years) with sIAAD was treated between 1990 and 2009. Dissection was asymptomatic in ten and symptomatic in eight patients. Retrospective data analysis from patient charts was performed. Follow-up included clinical examination, ultrasound, and/or CT-angiography. Mean follow-up was 54 months (range 1-211). RESULTS In total, eight out of 18 received invasive treatment. All asymptomatic patients initially underwent conservative treatment and surveillance. Spontaneous false lumen thrombosis occurred in four (40 %), and three patients showed relevant aneurysmatic progression and underwent elective invasive treatment (open n = 2, endovascular n = 1), representing a crossover rate of 30 %. Late mortality was 20 % (n = 2) in this group. In symptomatic patients, five underwent urgent treatment due to persistent abdominal or back pain (n = 4) or contained rupture (n = 1); one was treated for claudication. The remaining two patients presented with irreversible spinal cord ischemia and were treated conservatively. Three patients were treated by open surgery and three by endovascular interventions (two stentgrafts, one Palmaz XXL stent). Early and late morbidity and mortality was 0 % in this group. There were no reinterventions CONCLUSION: The majority of patients with sIADD require invasive treatment, with EVAR being the preferable treatment option today. In asymptomatic IADD, primary surveillance is justifiable, but close surveillance due to expansion is necessary.